At least 991 records · Page 55

Measurement of the Specific Heat Using a Gravity Cancellation Approach

The specific heat at constant volume C(sob V) of a simple fluid diverges near its liquid-vapor critical point. However, gravity-induced density stratification due to the divergence of isothermal susceptibility hinders the direct comparison of the experimental data with the predictions of renormalization group theory. In the past, a microgravity environment has been considered essential to eliminate the density stratification. We propose to perform specific heat measurements of He-3 on the ground using a method to cancel the density stratification. A He-3 fluid layer will be heated from below, using the thermal expansion of the fluid to cancel the hydrostatic compression. A 6% density stratification at a reduced temperature of 10(exp -5) can be cancelled to better than 0.1% with a steady 1.7 micro K temperature difference across a 0.05 cm thick fluid layer. A conventional AC calorimetry technique will be used to determine the heat capacity. The minimized bulk density stratification with a relaxation time 6500 sec at a reduced temperature of 10(exp -5) will stay unchanged during 1 Hz AC heating. The smear of the specific heat divergence due to the temperature difference across the cell is about 0.1% at a reduced temperature of 10(exp -6). The combination of using High Resolution Thermometry with a 0.5 n K temperature resolution in the AC technique and the cancellation of the density stratification will enable C(sub V) to be measured down to a reduced temperature of 10(exp -6) with less than a 1% systematic error.

Zhong, Fang↗

Film thickness measurement for spiral groove and Rayleigh step lift pad self-acting face seals

One Rayleigh step lift pad and three spiral groove self-acting face seal configurations were tested to measure film thickness and frictional torque as a function of shaft speed. The seals were tested at a constant face load of 73 N (16.4 lb) with ambient air at room temperature and atmospheric pressure as the fluid medium. The test speed range was from 7000 to 17,000 rpm. The measured film thickness was compared with theoretical data from mathematical models. The mathematical models overpredicted the measured film thickness at the lower speeds of the test speed range and underpredicted the measured film thickness at the higher speeds of the test speed range.

Dirusso, E.↗

Fluids and Materials Science Studies Utilizing the Microgravity-vibration Isolation Mount (MIM)

Canada's Microgravity Sciences Program (MSP) is the smallest program of the ISS partners and so can participate in only a few, highly focused projects in order to make a scientific and technological impact. One focused project involves determining the effect of accelerations (g-jitter) on scientific measurements in a microgravity environment utilizing the Microgravity-vibration Isolation Mount (MIM). Many experiments share the common characteristic of having a fluid stage in their process. The quality of the experimental measurements have been expected to be affected by g-jitters which has lead the ISS program to include specifications to limit the level of acceleration allowed on a subset of experimental racks. From finite element analysis (FEM), the ISS structure will not be able to meet the acceleration specifications. Therefore, isolation systems are necessary. Fluid science results and materials science results show significant sensitivity to g-jitter. The work done to date should be viewed only as a first look at the issue of g-jitter sensitivity. The work should continue with high priority such that the international science community and the ISS program can address the requirement and settle on an agreed to overall approach as soon as possible.

Herring, Rodney↗

Changes in leg volume during microgravity simulation

Little published information exists regarding the magnitude and time course of cephalad fluid shift resulting from microgravity simulations. Six subjects were exposed to 150 min each at horizontal bed rest, 6-deg head-down tilt, and horizontal water immersion. Fluid shift was estimated by calculating leg volumes from eight serial girth measurements from groin to ankle before, during, and after exposure. Results were compared with data from the first 3 h of spacecraft. By the end of exposure, total leg volume for the six subjects decreased by 2.6 +/- 0.8 percent, 1.7 +/- 1.2 percent, and 4.0 +/- 1.6 percent for horizontal, head-down, and immersion, respectively. Changes had plateaued for horizontal and head-down and had slowed for immersion. Relatively more fluid was lost from the lower leg than the thigh for all three conditions, particularly head-down. During the first 3 h of spaceflight, total leg volume decreased by 8.6 percent, and relatively more fluid was lost from the thigh than the lower leg. The difference in volume changes in microgravity and simulated microgravity may be caused by the small transverse pressures still present in ground-based simulations and the extremely nonlinear compliance of tissue.

Thornton, William E.↗

Internal Mixing Studied for GE/ARL Ejector Nozzle

To achieve jet noise reduction goals for the High Speed Civil Transport aircraft, researchers have been investigating the mixer-ejector nozzle concept. For this concept, a primary nozzle with multiple chutes is surrounded by an ejector. The ejector mixes low-momentum ambient air with the hot engine exhaust to reduce the jet velocity and, hence, the jet noise. It is desirable to mix the two streams as fast as possible in order to minimize the length and weight of the ejector. An earlier model of the mixer-ejector nozzle was tested extensively in the Aerodynamic Research Laboratory (ARL) of GE Aircraft Engines at Cincinnati, Ohio. While testing was continuing with later generations of the nozzle, the earlier model was brought to the NASA Lewis Research Center for relatively fundamental measurements. Goals of the Lewis study were to obtain details of the flow field to aid computational fluid dynamics (CFD) efforts and obtain a better understanding of the flow mechanisms, as well as to experiment with mixing enhancement devices, such as tabs. The measurements were made in an open jet facility for cold (unheated) flow without a surrounding coflowing stream.

Zaman, Khairul↗

Europa Clipper Passive Thermal Control Valve Test and Analysis

Europa Clipper spacecraft utilizes passive thermal control valves (TCV) in an active thermal control system to maintain spacecraft component temperatures within their allowable limits. The single-phase mechanically pumped fluid loop recovers heat from the electronics and uses it to maintain propulsion system warm. When excess heat is dissipated the mixing valves direct the fluid to the radiator to reject this additional heat. The loop uses two mixing TCVs placed in series to modulate fluid flow and heat rejection rate from the radiator. This paper describes the thermal and hydraulic test results for Europa Clipper engineering model (EM) mixing valves. For the first time two heritage mixing valves previously developed for the Mars Science Laboratory (MSL) were placed in series to modulate flow to the radiator from 0.1% to 95% of full flow between temperature range of 4 oC to 24 oC. Individually, each mixing valve was able to modulate the flow from 2% to 96% of full flow between the temperatures of 4 oC and 24 oC. Pressure drop was measured between 1.5 to 3 psid depending on the temperature of the mixed fluid and the opening fraction of the valves. A methodology was developed, tested, and validated to adjust the setpoints with an accuracy of 0.1 oC. The measured flow splits were corrected for the effects of impedance due to the flow meters used to measure the flow rates. Finally, flow rate to the radiator increased linearly as a function of mixed temperature for individual valves, while it increased parabolically with temperature when two mixing valves were placed in series.

Mastropietro, AJ↗

Comparison of Experimental Data and Computations Fluid Dynamics Analysis for a Three Dimensional Linear Plug Nozzle

A three dimensional linear plug nozzle of area ratio 12.79 was designed by Astrium. The nozzle was tested within the German National Technology Program LION in a cold air wind tunnel by TU Dresden. The experimental hardware and test conditions are described. Experimental data was obtained for the nozzle without plug side wall fences and then with plug side wall fences. Experimental data for two nozzle pressure ratios (NPR), 116 and 45, are presented for the without fence and with fence configurations. Schlieren images of both NPR were recorded. Axial profiles of plug wall static pressures were measured at several spanwise locations and on the plug base. Detailed computational fluid dynamics (CFD) analysis was performed for these nozzle configurations by NASA MSFC. The CFD exhibits good agreement with the experimental data. A detailed comparison of the CFD results and the experimental plug wall pressure data is given for four test conditions; at both NPRs, without and with plug side wall fences. Numerical schlieren images are compared to experimental schlieren images. Nozzle thrust efficiencies are calculated from the CFD results. The CFD results are used to illustrate the plug nozzle fluid dynamics for all four test conditions. The effect of the plug side wall fences at both NPRs is emphasized.

Ruf, J. H.↗

Phosphate Stability in Diagenetic Fluids Constrains the Acidic Alteration Model for Lower Mt. Sharp Sedimentary Rocks in Gale Crater, Mars

The Mars rover Curiosity has encountered silica-enriched bedrock (as strata and as veins and associated halos of alteration) in the largely basaltic Murray Fm. of Mt. Sharp in Gale Crater. Alpha Particle X-ray Spectrometer (APXS) investigations of the Murray Fm. revealed decreasing Mg, Ca, Mn, Fe, and Al, and higher S, as silica increased (Fig. 1). A positive correlation between SiO2 and TiO2 (up to 74.4 and 1.7 wt %, respectively) suggests that these two insoluble elements were retained while acidic fluids leached more soluble elements. Other evidence also supports a silica-retaining, acidic alteration model for the Murray Fm., including low trace element abundances consistent with leaching, and the presence of opaline silica and jarosite determined by CheMin. Phosphate stability is a key component of this model because PO4 3- is typically soluble in acidic water and is likely a mobile ion in diagenetic fluids (pH less than 5). However, the Murray rocks are not leached of P; they have variable P2O5 (Fig. 1) ranging from average Mars (0.9 wt%) up to the highest values in Gale Crater (2.5 wt%). Here we evaluate APXS measurements of Murray Fm. bedrock and veins with respect to phosphate stability in acidic fluids as a test of the acidic alteration model for the Lower Mt. Sharp rocks.

Berger, J. A.↗

Calorimetric thermal-vacuum performance characterization of the BAe 80 K space cryocooler

A comprehensive characterization program is underway at JPL to generate test data on long-life, miniature Stirling-cycle cryocoolers for space application. The key focus of this paper is on the thermal performance of the British Aerospace (BAe) 80 K split-Stirling-cycle cryocooler as measured in a unique calorimetric thermal-vacuum test chamber that accurately simulates the heat-transfer interfaces of space. Two separate cooling fluid loops provide precise individual control of the compressor and displacer heatsink temperatures. In addition, heatflow transducers enable calorimetric measurements of the heat rejected separately by the compressor and displacer. Cooler thermal performance has been mapped for coldtip temperatures ranging from below 45 K to above 150 K, for heatsink temperatures ranging from 280 K to 320 K, and for a wide variety of operational variables including compressor-displacer phase, compressor-displacer stroke, drive frequency, and piston-displacer dc offset.

Kotsubo, V. Y.↗

Alterations in glomerular and tubular dynamics at 1 and 14 days simulated microgravity and after acute return to orthostasis

Head-down tilt (HDT) is utilized to simulate microgravity and produces a cephalad fluid shift, which results in alterations in fluid and electrolyte balance. These changes in volume homeostasis are due, in part, to alterations in multiple volume control mechanisms in which renal function is a major participant. We have previously demonstrated that glomerular filtration rate increases early in HDT and eventually returns to values not different from non-tilt measurements. This early increase in glomerular filtration rate was also demonstrated during days 2 and 8 of the SLS-1 mission. However, urine flow and electrolyte excretion does not parallel the alternations in glomerular filtration rate and the site of this change in nephron fluid reabsorption pattern has not been previously examined. Through determination of the location of alterations in tubular fluid reabsorption within the nephron, a more detailed hypothesis can be forwarded as to which specific neuro-humoral agents participating in control or renal function in microgravity conditions. the importance of this type of examination is that measurements in circulating neuro-humoral agents and urinary excretion patterns alone are not accurate predictors of how renal functional response may alter to head-down tilt or other models of simulated weightlessness. To examine this issue, renal micropuncture techniques were utilized in Munich-Wistar rats submitted 24 hour and 14 day head-down tilt, measuring all the determinants of glomerular ultrafiltration and obtaining data regarding segmental tubular fluid reabsorption. Following these measurements, the rats were returned to an orthostatic position and after 60 minutes, the measurements were repeated.

Tucker, Bryan J.↗

A potential nuclear magnetic resonance imaging approach for noncontact temperature measurement

It is proposed that in a nuclear magnetic resonance (NMR) imaging experiment that it should be possible to measure temperature through an extended volume. The basis for such a measurement would depend upon sensing a temperature dependent on NMR parameter in an inert, volatile molecule (or fluid) filling the volume of interest. Exploratory work suggest that one suitable candidate for such a purpose might be CH3Cl. Possible parameters, other inert gases and feasible measurement schemes that might provide such temperature measurement are discussed.

Manatt, Stanley L.↗

Cardiovascular dynamics during the initial period of head-down tilt

The cardiovascular response to 1 h of 60-deg head-down tilt was studied in 12 male subjects, ages 30-39 years, to simulate the early effects of weightlessness. Fluid shifts, hemodynamic variables, and indices of myocardial contractility were evaluated by utilizing electrocardiography, systolic time intervals, impedance cardiography, sphygmomanometry, and measurement of calf circumference. Most cardiovascular variables remained stable throughout the initial 30 min of the protocol, even though translocation of fluid from the legs to the thorax commenced immediately with the onset of head-down tilt. In contrast, minutes 30-60 were characterized by reduced stroke volume, cardiac output, mean stroke ejection rate, and Heather index concomitant with an elevation in mean arterial pressure. Intrathoracic fluid volume continued to increase, while leg volume continued to decrease. This latter physiological response suggests intrathoracic sequestration of fluid volume; blood was apparently redistributed to the pulmonary circulation rather than being retained in the great veins.

Tomaselli, Clare Marie↗

Shadowgraphy of transcritical cryogenic fluids

The future of liquid-rocket propulsion depends heavily on continued development of high pressure liquid oxygen/hydrogen systems that operate near or above the propellant critical states; however, current understanding of transcritical/supercritical injection and combustion is yet lacking. The Phillips Laboratory and the United Technologies Research Center are involved in a collaborative effort to develop diagnostics for and make detailed measurements of transcritical droplet vaporization and combustion. The present shadowgraph study of transcritical cryogenic fluids is aimed at providing insight into the behavior of liquid oxygen or cryogenic stimulants as they are injected into a supercritical environment of the same or other fluids. A detailed history of transcritical injection of liquid nitrogen into gaseous nitrogen at reduced pressures of 0.63 (subcritical) to 1.05 (supercritical) is provided. Also, critical point enhancement due to gas phase solubility and mixture effects is investigated by adding helium to the nitrogen system, which causes a distinct liquid phase to re-appear at supercritical nitrogen pressures. Liquid oxygen injection into supercritical argon or nitrogen, however, does not indicate an increase in the effective critical pressure of the system.

Woodward, R. D.↗

Some limitations in applying classical EHD film thickness formulas to a high-speed bearing

Elastohydrodynamic film thickness was measured for a 20-mm ball bearing using the capacitance technique. The bearing was thrust loaded to 90, 448, and 778 N. The corresponding maximum stresses on the inner race were 1.28, 2.09, and 2.45 GPa. Test speeds ranged from 400 to 14,000 rpm. Film thickness measurements were taken with four different lubricants: (a) synthetic paraffinic, (b) synthetic paraffinic with additives, (c) neopentylpolyol (tetra) ester meeting MIL-L-23699A specifications, and (d) synthetic cycloaliphatic hydrocarbon traction fluid. The test bearing was mist lubricated. Test temperatures were 300, 338, and 393 K. The measured results were compared to theoretical predictions using the formulas of Grubin, Archard and Cowking, Dowson and Higginson, and Hamrock and Dowson. There was good agreement with theory at low dimensionless speed, but the film was much smaller than theory predicts at higher speeds. This was due to kinematic starvation and inlet shear heating effects.

Coy, J. J.↗

Measuring ground movement in geothermal areas of Imperial Valley, California

Significant ground movement may accompany the extraction of large quantities of fluids from the subsurface. In Imperial Valley, California, one of the potential hazards of geothermal development is the threat of both subsidence and horizontal movement of the land surface. Regional and local survey nets are being monitored to detect and measure possible ground movement caused by future geothermal developments. Precise measurement of surface and subsurface changes will be required to differentiate man-induced changes from natural processes in this tectonically active region.

Lofgren, B. E.↗

Calibration Probe Uncertainty and Validation for the Hypersonic Material Environmental Test System

This paper presents an uncertainty analysis of the stagnation-point calibration probe surface predictions for conditions that span the performance envelope of the Hypersonic Materials Environmental Test System facility located at NASA Langley Research Center. A second-order stochastic expansion was constructed over 47 uncertain parameters to evaluate the sensitivities, identify the most significant uncertain variables, and quantify the uncertainty in the stagnation-point heat flux and pressure predictions of the calibration probe for a low- and high-enthalpy test condition. A sensitivity analysis showed that measurement bias uncertainty is the most significant contributor to the stagnation-point pressure and heat flux variance for the low-enthalpy condition. For the high-enthalpy condition, a paradigm shift in sensitivities revealed the computational fluid dynamics model input uncertainty as the main contributor. A comparison between the prediction and measurement of the stagnation-point conditions under uncertainty showed that there was evidence of statistical disagreement. A validation metric was proposed and applied to the prediction uncertainty to account for the statistical disagreement when compared to the possible stagnation-point heat flux and pressure measurements.

Brune, Andrew J.↗

Measurement of Acute Changes in Choroid Thickness in Healthy Eyes During Posture Change Using Optical Coherence Tomography

The Visual Impairment and Intracranial Pressure (VIIP) syndrome affects 60% of astronauts returning from long-duration missions and is characterized by structural and functional changes of the eye (3). Upon entry into weightlessness, approximately two liters of fluid translocates from the lower body to the thorax and cephalad regions, potentially contributing to elevated intracranial and intraocular pressures. The choroid is the vasculature that supplies blood flow to the posterior part of the retina and has limited autoregulation. As a consequence these vessels may engorge during a cephalad fluid shift, contributing to structural changes in the retina. The purpose of this experiment was to quantify changes in choroid thickness during a fluid shift. In order to fulfill this objective, it was also necessary to improve the measurement technique for assessing choroid thickness.

Ferguson, Connor R.↗