Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtering techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

High-speed, room-temperature quantum cascade detectors at 4.3 μm

We present high-speed, room-temperature operated 4.3 μm quantum cascade detectors. The devices are processed as square mesas with 50 Ω coplanar access line and air-bridge connector. The high frequency features are explored using microwave rectification technique and a RLC circuit model. The -3 dB cutoff frequency is experimentally 9 GHz and 4 GHz for 20×20 μm{sup 2} and 50×50 μm{sup 2} detectors, respectively. The equivalent circuit analysis shows that a second order filter feature governs the devices. Higher cutoff frequency can be achieved by eliminate the parasitics further.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multicarrier Spread Spectrum Communications With Noncontiguous Subcarrier Bands for HF Skywave Links

Existing high-frequency (HF) radio platforms offer robust performance against the volatile HF propagation channel. However, the growing traffic across the band contests the reliability of these systems. While techniques to mitigate the effects of narrowband interference have been thoroughly explored, they are insufficient against wideband interference or when the transmission band is occupied by numerous scattered users. To improve reliability in these congested channel conditions, we propose a filter-bank based multicarrier spread-spectrum waveform with noncontiguous subcarrier bands. Using noncontiguous subcarrier bands enables the system to at once leverage the robustness of a wideband system while retaining the frequency agility of a narrowband system. In this study, we modify a filter-bank transmitter structure to accommodate noncontiguous subcarrier bands and consider several immediate impacts of this change, such as elevated peak-to-average-power ratios (PAPRs). A receiver architecture to process the noncontiguous spread-spectrum signal is also introduced, along with details regarding wideband channel estimation. Finally, we develop efficient transmitter and receiver structures to support practical system implementations. We conclude by comparing the performance of contiguous and noncontiguous systems through both simulation and over-the-air testing. The results show that the noncontiguous system remains robust in typical HF channels while significantly outperforming the contiguous system in congested spectral conditions.

(PAPR↗

Transfer Learning-Based Independent Component Analysis

Understanding the underlying component structure is crucial for multivariate signal analysis. Among all the techniques that try to learn the latent structure, independent component analysis (ICA) is one of the most important and popular methods, which aims to extract independent components from multivariate signals and enables further analysis. For example, in electroencephalogram (EEG) analysis, artifacts filtering and disease detection are conducted based on the independent components of the signals. One critical challenge in existing ICA approaches is that the component extraction accuracy may degrade when the available data of a unit are limited. To address this issue, this paper proposes a transfer learning-based ICA method by innovatively transferring component distribution from a source domain, so that accurate component extraction results can be achieved even when only limited data are available in the target domain. To the best of our knowledge, this is the first work that leverages transfer learning to improve ICA accuracy with limited available data. In particular, we first extract all the independent components from the source domain by maximizing the log-likelihood function with a Newton-like method on a smooth manifold. Then for the target domain, the component with the largest negentropy is extracted in each round. To effectively leverage the knowledge from the source domain and to prevent the negative transfer, we try to find a component in the source domain that matches the component we are extracting. The probability density function of the matched component will then be used to improve the component extraction accuracy if such matched component can be found; otherwise, no knowledge will be transferred. Finally, numerical simulations and a case study with electrocardiogram (ECG) data are conducted, showing the effectiveness of the proposed method in transferring knowledge and reducing negative transfer.

42 ENGINEERING↗

Evaluation of digital breast tomosynthesis reconstruction algorithms using synchrotron radiation in standard geometry

Purpose: In this article, the image quality of reconstructed volumes by four algorithms for digital tomosynthesis, applied in the case of breast, is investigated using synchrotron radiation. Methods: An angular data set of 21 images of a complex phantom with heterogeneous tissue-mimicking background was obtained using the SYRMEP beamline at ELETTRA Synchrotron Light Laboratory, Trieste, Italy. The irradiated part was reconstructed using the multiple projection algorithm (MPA) and the filtered backprojection with ramp followed by hamming windows (FBR-RH) and filtered backprojection with ramp (FBP-R). Additionally, an algorithm for reducing the noise in reconstructed planes based on noise mask subtraction from the planes of the originally reconstructed volume using MPA (MPA-NM) has been further developed. The reconstruction techniques were evaluated in terms of calculations and comparison of the contrast-to-noise ratio (CNR) and artifact spread function. Results: It was found that the MPA-NM resulted in higher CNR, comparable with the CNR of FBP-RH for high contrast details. Low contrast objects are well visualized and characterized by high CNR using the simple MPA and the MPA-NM. In addition, the image quality of the reconstructed features in terms of CNR and visual appearance as a function of the initial number of projection images and the reconstruction arc was carried out. Slices reconstructed with more input projection images result in less reconstruction artifacts and higher detail CNR, while those reconstructed from projection images acquired in reduced angular range causes pronounced streak artifacts. Conclusions: Of the reconstruction algorithms implemented, the MPA-NM and MPA are a good choice for detecting low contrast objects, while the FBP-RH, FBP-R, and MPA-NM provide high CNR and well outlined edges in case of microcalcifications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Kick Detection at the Bit: Early Detection via Low Cost Monitoring

Formation fluid influxes (i.e. kicks) pose persistent challenges and operational costs during drilling operations. Implications of kicks range in scale but cumulatively result in substantial costs that affect drilling safety, environment, schedule, and infrastructure. Early kick detection presents a low-cost, easily adopted solution for avoiding well control challenges associated with kicks near the bit. Borehole geophysical tools used during the drilling process as part of the logging-while-drilling (LWD) and measurement-while-drilling (MWD) provide the advantage of offering real-time downhole data. LWD/MWD collect data on both the annulus and borehole wall. The annular data are normally treated as background, and are filtered out to isolate the formation measurements. Because kicks will change the local physical properties of annular fluids, bottom-hole measurements are among the first indicators that a formation fluid has invaded the wellbore. This report describes and validates a technique for using the annular portion of LWD/MWD data to facilitate early kick detection using first order principles. The detection technique leverages data from standard and cost-effective technologies that are typically implemented during well drilling, such as MWD/LWD data in combination with mud-pulse telemetry for data transmission.

42 ENGINEERING↗

Extraction of Mercury Utilizing 3D Printed Media - Mercury Extraction Coalescer (MEC) (Revision 1)

The presence of mercury in environmental or industrial settings presents a number of issues from bio-accumulation to production of toxic by-products. The primary objective of this project was the development of a 3D printed component designed to act as a coalescing filter for the removal or segregation of elemental mercury from aqueous streams. The use of 3D printing allows for the design and integration of surface microstructures and internal geometries that could be difficult if not impossible to achieve through traditional manufacturing techniques. The initial phase of testing focused on the integration of 3D printed components into both environmental remediation testing (university subcontracted testing) and simulations of high-level nuclear waste processing (SRNL). Structures ranged from simple torturous paths that provided regions where the elemental mercury could settle out of the recirculation process to micro-structured frits that have increased surface area for aid in droplet coalescence and surface adsorption.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solving large-scale sparse eigenvalue problems and linear systems of equations for accelerator modeling

The solutions of sparse eigenvalue problems and linear systems constitute one of the key computational kernels in the discretization of partial differential equations for the modeling of linear accelerators. The computational challenges faced by existing techniques for solving those sparse eigenvalue problems and linear systems call for continuing research to improve on the algorithms so that ever increasing problem size as required by the physics application can be tackled. Under the support of this award, the filter algorithm for solving large sparse eigenvalue problems was developed at Stanford to address the computational difficulties in the previous methods with the goal to enable accelerator simulations on then the world largest unclassified supercomputer at NERSC for this class of problems. Specifically, a new method, the Hemitian skew-Hemitian splitting method, was proposed and researched as an improved method for solving linear systems with non-Hermitian positive definite and semidefinite matrices.

43 PARTICLE ACCELERATORS↗

Bayesian classification of partially observed outbreaks using time-series data.

Results show that a time-series based classification may be possible. For the test cases considered, the correct model can be selected and the number of index case can be captured within {+-} {sigma} with 5-10 days of data. The low signal-to-noise ratio makes the classification difficult for small epidemics. The problem statement is: (1) Create Bayesian techniques to classify and characterize epidemics from a time-series of ICD-9 codes (will call this time-series a 'morbidity stream'); and (2) It is assumed the morbidity stream has already set off an alarm (through a Kalman filter anomaly detector) Starting with a set of putative diseases: Identify which disease or set of diseases 'fit the data best' and, Infer associated information about it, i.e. number of index cases, start time of the epidemic, spread rate, etc.

99 GENERAL AND MISCELLANEOUS↗

DIRECT LASER DEPOSITION OF POROUS STRUCTURES AND GRADIENT METAL-CERAMIC COMPOSITE COATINGS

Direct laser deposition is an additive manufacturing technique capable of producing complex geometries, bond different materials, repair broken parts, and add protective coating. In the present study it is used to make micro-porous scaffolds and apply protective vanadium and niobium carbide coatings. Micro-porous metal filters are a difficult thing to make but are required for many applications. In this study it was hypothesized that laser engineering net shaping (LENS) could be used to make porous Ti6Al4V scaffolds with an interconnected micro-porous structure. This proved to be true with cylinders made to have 15.9% porosity, and a pore size less than 100μm. These structures were made by only altering processing parameters, which yielded a scaffold with obstructed random pore interconnectivity. The scaffolds had a compressive strength of 645-556MPa and martensitic like α' grains. Another study was done to apply hard niobium and vanadium carbide surface coatings to stainless steel. The objective was to used LENS to deposit stainless steel coatings with added carbides to eventually make a gradient coating with increased protective qualities. Parts that have suffered material loss from abrasive wear or cavitation could have material added back as well as add a protective coating at the same time. Compositions ranging from 5% to 100% of the carbides were mixed with stainless steel. The coatings were then deposited on a stainless steel 304 substrate individually, as well as in a series to make a gradient structure. These coatings all increased hardness, wear resistance, and 100%VC significantly increased the materials resistance to damage from abrasive water. The carbides integrated into the SS304 matrix on the grain boundaries making a metal ceramic composite. These precipitates left residual stress in the structure which increased the hardness and wear resistance. The study proved that the addition of these carbides did increase the protective qualities and could make a gradient coating with properties tailored to the user’s preference.

13 HYDRO ENERGY↗

Modeling laser wakefield accelerators in a Lorentz boosted frame

Modeling of laser-plasma wakefield accelerators in an optimal frame of reference is shown to produce orders of magnitude speed-up of calculations from first principles. Obtaining these speedups requires mitigation of a high-frequency instability that otherwise limits effectiveness in addition to solutions for handling data input and output in a relativistically boosted frame of reference. The observed high-frequency instability is mitigated using methods including an electromagnetic solver with tunable coefficients, its extension to accomodate Perfectly Matched Layers and Friedman's damping algorithms, as well as an efficient large bandwidth digital filter. It is shown that choosing the frame of the wake as the frame of reference allows for higher levels of filtering and damping than is possible in other frames for the same accuracy. Detailed testing also revealed serendipitously the existence of a singular time step at which the instability level is minimized, independently of numerical dispersion, thus indicating that the observed instability may not be due primarily to Numerical Cerenkov as has been conjectured. The techniques developed for Cerenkov mitigation prove nonetheless to be very efficient at controlling the instability. Using these techniques, agreement at the percentage level is demonstrated between simulations using different frames of reference, with speedups reaching two orders of magnitude for a 0.1 GeV class stages. The method then allows direct and efficient full-scale modeling of deeply depleted laser-plasma stages of 10 GeV-1 TeV for the first time, verifying the scaling of plasma accelerators to very high energies. Over 4, 5 and 6 orders of magnitude speedup is achieved for the modeling of 10 GeV, 100 GeV and 1 TeV class stages, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling laser wakefield accelerators in a Lorentz boosted frame

Modeling of laser-plasma wakefield accelerators in an optimal frame of reference [1] is shown to produce orders of magnitude speed-up of calculations from first principles. Obtaining these speedups requires mitigation of a high frequency instability that otherwise limits effectiveness in addition to solutions for handling data input and output in a relativistically boosted frame of reference. The observed high-frequency instability is mitigated using methods including an electromagnetic solver with tunable coefficients, its extension to accomodate Perfectly Matched Layers and Friedman's damping algorithms, as well as an efficient large bandwidth digital filter. It is shown that choosing theframe of the wake as the frame of reference allows for higher levels of filtering and damping than is possible in other frames for the same accuracy. Detailed testing also revealed serendipitously the existence of a singular time step at which the instability level is minimized, independently of numerical dispersion, thus indicating that the observed instability may not be due primarily to Numerical Cerenkov as has been conjectured. The techniques developed for Cerenkov mitigation prove nonetheless to be very efficient at controlling the instability. Using these techniques, agreement at the percentage level is demonstrated between simulations using different frames of reference, with speedups reaching two orders of magnitude for a 0.1 GeV class stages. The method then allows direct and efficient full-scale modeling of deeply depleted laser-plasma stages of 10 GeV-1 TeV for the first time, verifying the scaling of plasma accelerators to very high energies. Over 4, 5 and 6 orders of magnitude speedup is achieved for the modeling of 10 GeV, 100 GeV and 1 TeV class stages, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning

Purpose: To evaluate the metal artifacts in kilovoltage computed tomography (kVCT) images that are corrected using a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images.Methods: Tissue characterization phantoms containing bilateral steel inserts are used in all experiments. Two MVCT images, one without any metal artifact corrections and the other corrected using a modified iterative maximum likelihood polychromatic algorithm for CT (IMPACT) are translated to pseudo-kVCT images. These are then used as prior images without tissue classification in an NMAR technique for correcting the experimental kVCT image. The IMPACT method in MVCT included an additional model for the pair/triplet production process and the energy dependent response of the MVCT detectors. An experimental kVCT image, without the metal inserts and reconstructed using the filtered back projection (FBP) method, is artificially patched with the known steel inserts to get a reference image. The regular NMAR image containing the steel inserts that uses tissue classified kVCT prior and the NMAR images reconstructed using MVCT priors are compared with the reference image for metal artifact reduction. The Eclipse treatment planning system is used to calculate radiotherapy dose distributions on the corrected images and on the reference image using the Anisotropic Analytical Algorithm with 6 MV parallel opposed 5 × 10 cm{sup 2} fields passing through the bilateral steel inserts, and the results are compared. Gafchromic film is used to measure the actual dose delivered in a plane perpendicular to the beams at the isocenter.Results: The streaking and shading in the NMAR image using tissue classifications are significantly reduced. However, the structures, including metal, are deformed. Some uniform regions appear to have eroded from one side. There is a large variation of attenuation values inside the metal inserts. Similar results are seen in commercially corrected image. Use of MVCT prior images without tissue classification in NMAR significantly reduces these problems. The radiation dose calculated on the reference image is close to the dose measured using the film. Compared to the reference image, the calculated dose difference in the conventional NMAR image, the corrected images using uncorrected MVCT image, and IMPACT corrected MVCT image as priors is ∼15.5%, ∼5%, and ∼2.7%, respectively, at the isocenter.Conclusions: The deformation and erosion of the structures present in regular NMAR corrected images can be largely reduced by using MVCT priors without tissue segmentation. The attenuation value of metal being incorrect, large dose differences relative to the true value can result when using the conventional NMAR image. This difference can be significantly reduced if MVCT images are used as priors. Reduced tissue deformation, better tissue visualization, and correct information about the electron density of the tissues and metals in the artifact corrected images could help delineate the structures better, as well as calculate radiation dose more correctly, thus enhancing the quality of the radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On Aerosol Liquid Water and Sulfate Associations: The Potential for Fine Particulate Matter Biases

In humid locations of the Eastern U.S., sulfate is a surrogate for aerosol liquid water (ALW), a poorly measured particle constituent. Regional and seasonal variation in ALW–sulfate relationships offers a potential explanation to reconcile epidemiology and toxicology studies regarding particulate sulfur and health endpoints. ALW facilitates transfer of polar species from the gas phase to the particle phase and affects particle pH and metal oxidation state. Though abundant and a potential indicator of adverse health endpoints, ALW is largely removed in most particulate matter measurement techniques, including in routine particulate matter (PM 2.5 ) networks that use federal reference method (FRM) monitors, which are used in epidemiology studies. We find that in 2004, a typical year in the available record, ambient ALW mass is removed during sampling and filter equilibration to standard laboratory conditions at most (94%) sites, up to 85% of the ambient water mass. The removal of ALW can induce the evaporation of other semi-volatile compounds present in PM 2.5 , such as ammonium nitrate and numerous organics. This produces an artifact in the PM mass measurements that is, importantly, not uniform in space or time. This suggests that PM 2.5 epidemiology studies that exclude ALW are biased. This work provides a plausible explanation to resolve multi-decade discrepancies regarding ambient sulfate and health impacts in some epidemiological and toxicological studies

54 ENVIRONMENTAL SCIENCES↗

Regenerable particulate filter

A method of making a three-dimensional lattice structure, such as a filter used to remove particulates from a gas stream, where the physical lattice structure is designed utilizing software simulation from pre-defined mass transfer and flow characteristics and the designed lattice structure is fabricated using a free-form fabrication manufacturing technique, where the periodic lattice structure is comprised of individual geometric elements.

47 OTHER INSTRUMENTATION↗

Dispersion of magnetic fields in molecular clouds. IV. Analysis of interferometry data

We expand on the dispersion analysis of polarimetry maps toward applications to interferometry data. We show how the filtering of low spatial frequencies can be accounted for within the idealized Gaussian turbulence model, initially introduced for single-dish data analysis, to recover reliable estimates for correlation lengths of magnetized turbulence, as well as magnetic field strengths (plane-of-the-sky component) using the Davis–Chandrasekhar–Fermi method. We apply our updated technique to TADPOL/CARMA data obtained on W3(OH), W3 Main, and DR21(OH). For W3(OH), our analysis yields a turbulence correlation length δ≃19 mpc, a ratio of turbulent-to-total magnetic energy 〈B{sub t}{sup 2}〉/〈B{sup 2}〉≃0.58, and a magnetic field strength B{sub 0}∼1.1 mG; for W3 Main δ≃22 mpc, 〈B{sub t}{sup 2}〉/〈B{sup 2}〉≃0.74, and B{sub 0}∼0.7 mG; while for DR21(OH) δ≃12 mpc, 〈B{sub t}{sup 2}〉/〈B{sup 2}〉≃0.70, and B{sub 0}∼1.2 mG.

79 ASTRONOMY AND ASTROPHYSICS↗

Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging

Purpose: This work applies a cascaded systems model for cone-beam CT imaging performance to the design and optimization of a system for musculoskeletal extremity imaging. The model provides a quantitative guide to the selection of system geometry, source and detector components, acquisition techniques, and reconstruction parameters. Methods: The model is based on cascaded systems analysis of the 3D noise-power spectrum (NPS) and noise-equivalent quanta (NEQ) combined with factors of system geometry (magnification, focal spot size, and scatter-to-primary ratio) and anatomical background clutter. The model was extended to task-based analysis of detectability index (d') for tasks ranging in contrast and frequency content, and d' was computed as a function of system magnification, detector pixel size, focal spot size, kVp, dose, electronic noise, voxel size, and reconstruction filter to examine trade-offs and optima among such factors in multivariate analysis. The model was tested quantitatively versus the measured NPS and qualitatively in cadaver images as a function of kVp, dose, pixel size, and reconstruction filter under conditions corresponding to the proposed scanner. Results: The analysis quantified trade-offs among factors of spatial resolution, noise, and dose. System magnification (M) was a critical design parameter with strong effect on spatial resolution, dose, and x-ray scatter, and a fairly robust optimum was identified at M {approx} 1.3 for the imaging tasks considered. The results suggested kVp selection in the range of {approx}65-90 kVp, the lower end (65 kVp) maximizing subject contrast and the upper end maximizing NEQ (90 kVp). The analysis quantified fairly intuitive results--e.g., {approx}0.1-0.2 mm pixel size (and a sharp reconstruction filter) optimal for high-frequency tasks (bone detail) compared to {approx}0.4 mm pixel size (and a smooth reconstruction filter) for low-frequency (soft-tissue) tasks. This result suggests a specific protocol for 1 x 1 (full-resolution) projection data acquisition followed by full-resolution reconstruction with a sharp filter for high-frequency tasks along with 2 x 2 binning reconstruction with a smooth filter for low-frequency tasks. The analysis guided selection of specific source and detector components implemented on the proposed scanner. The analysis also quantified the potential benefits and points of diminishing return in focal spot size, reduced electronic noise, finer detector pixels, and low-dose limits of detectability. Theoretical results agreed quantitatively with the measured NPS and qualitatively with evaluation of cadaver images by a musculoskeletal radiologist. Conclusions: A fairly comprehensive model for 3D imaging performance in cone-beam CT combines factors of quantum noise, system geometry, anatomical background, and imaging task. The analysis provided a valuable, quantitative guide to design, optimization, and technique selection for a musculoskeletal extremities imaging system under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Selective Detection of Intermediate-Amplitude Motion by Solid-State NMR

The coexistence of rigid and mobile molecules or molecular segments abounds in biomolecular assemblies. Examples include the carbohydrate-rich cell walls of plants and intrinsically disordered proteins that contain rigid β-sheet cores. In solid-state nuclear magnetic resonance (NMR) spectroscopy, dipolar polarization transfer experiments are well suited for detecting rigid components, whereas scalar-coupling experiments are well suited for detecting highly mobile components. However, few NMR methods are available to detect the segments that undergo intermediate-amplitude fast motion. Here, we introduce two NMR experiments, a two-dimensional T 2H -filtered CP-hCH correlation and a three-dimensional J-INADEQUATE CCH correlation, to observe this intermediate-amplitude motion. Both experiments involve 1 H detection under fast magic-angle spinning (MAS). By combining 1 H transverse relaxation (T 2H ) filters with dipolar polarization transfer, we suppress the signals of both highly rigid and highly mobile species, thus revealing the signals of intermediate mobile species. 1 H detection under fast MAS is crucial for distinguishing the different motional amplitudes. Here, we demonstrate these techniques on several plant cell wall samples and show that they allow the selective detection and resolution of certain hemicellulose and pectin signals, which are usually masked by the signals of the rigid cellulose and the highly dynamic pectins in purely dipolar and scalar NMR spectra.

59 BASIC BIOLOGICAL SCIENCES↗

Broadband Infrared Carbon Nanotube Linear Photodetector Arrays

Carbon nanotubes (CNTs) possess exceptional optoelectronic properties, including broadband absorption and high absorption coefficients, making them promising candidates for photodetector applications. However, conventional designs often rely on single or aligned nanotubes, which restrict device scalability and require complex fabrication techniques. Here, in this work, we address these limitations by utilizing CNT-suspended solutions to fabricate large-area photodetectors based on CNT networks via vacuum filtration and direct laser scribing. CNT networks are uniformly formed onto low-thermal-conductance polymeric filter papers that serve as substrates and mitigate the need for suspended structures, reducing the fabrication complexity and cost. The CNT films are patterned into single devices and 49-pixel linear arrays by using a laser-cutting process, enabling scalable and cost-effective production. The resulting devices operate as bolometers and exhibit broad spectral sensitivity extending from visible to midwave infrared, showing stable operation at room temperature. We further demonstrate proof-of-concept IR imaging using linear arrays.

IR imaging↗