Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Association Between Tangential Beam Treatment Parameters and Cardiac Abnormalities After Definitive Radiation Treatment for Left-Sided Breast Cancer

Purpose: To examine the association between radiation treatment (RT) parameters, cardiac diagnostic test abnormalities, and clinical cardiovascular diagnoses among patients with left-sided breast cancer after breast conservation treatment with tangential beam RT. Methods and Materials: The medical records of 416 patients treated between 1977 and 1995 with RT for primary left-sided breast cancer were reviewed for myocardial perfusion imaging and echocardiograms. Sixty-two patients (62/416, 15%) underwent these cardiac diagnostic tests for cardiovascular symptoms and were selected for further study. Central lung distance and maximum heart width and length in the treatment field were determined for each patient. Medical records were reviewed for cardiovascular diagnoses and evaluation of cardiac risk factors. Results: At a median of 12 years post-RT the incidence of cardiac diagnostic test abnormalities among symptomatic left-sided irradiated women was significantly higher than the predicted incidence of cardiovascular disease in the patient population, 6/62 (9%) predicted vs. 24/62 (39%) observed, p 0.001. As compared with patients with normal tests, patients with cardiac diagnostic test abnormalities had a larger median central lung distance (2.6 cm vs. 2.2 cm, p = 0.01). Similarly, patients with vs. without congestive heart failure had a larger median central lung distance (2.8 cm vs. 2.3 cm, p = 0.008). Conclusions: Contemporary RT for early breast cancer may be associated with a small, but potentially avoidable, risk of cardiovascular morbidity that is associated with treatment technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diesel exhaust exposure enhances venoconstriction via uncoupling of eNOS

Environmental air pollution is associated with adverse cardiovascular events, including increased hospital admissions due to heart failure and myocardial infarction. The exact mechanism(s) by which air pollution affects the heart and vasculature is currently unknown. Recent studies have found that exposure to air pollution enhances arterial vasoconstriction in humans and animal models. Work in our laboratory has shown that diesel emissions (DE) enhance vasoconstriction of mouse coronary arteries. Thus, we hypothesized that DE could enhance vasoconstriction in arteries and veins through uncoupling of endothelial nitric oxide synthase (eNOS). To test this hypothesis, we first bubbled DE through a physiological saline solution and exposed isolated mesenteric veins. Second, we exposed animals, whole body, to DE at 350 {mu}g/m{sup 3} for 4 h, after which mesenteric arteries and veins were isolated. Results from these experiments show that saline bubbled with DE as well as inhaled DE enhances vasoconstriction in veins but not arteries. Exposure to several representative volatile organic compounds found in the DE-exposed saline did not enhance arterial constriction. L-nitro-arginine-methyl-ester (L-NAME), an eNOS inhibitor, normalized the control vessels to the DE-exposed vessels implicating an uncoupling of eNOS as a mechanism for enhanced vasoconstriction. The principal conclusions of this research are 1) veins exhibit endothelial dysfunction following in vivo and ex vivo exposures to DE, 2) veins appear to be more sensitive to DE effects than arteries, and 3) DE components most likely induce endothelial dysfunction through the uncoupling of eNOS.

60 APPLIED LIFE SCIENCES↗

The H{sub 1}–H{sub 2} domain of the α{sub 1} isoform of Na{sup +}–K{sup +}–ATPase is involved in ouabain toxicity in rat ventricular myocytes

The composition of different isoforms of Na{sup +}-K{sup +}-ATPase (NKA, Na/K pump) in ventricular myocytes is an important factor in determining the therapeutic effect and toxicity of cardiac glycosides (CGs) on heart failure. The mechanism whereby CGs cause these effects is still not completely clear. In the present study, we prepared two site-specific antibodies (SSA78 and WJS) against the H{sub 1}–H{sub 2} domain of α{sub 1} and α{sub 2} isoforms of NKA in rat heart, respectively, and compared their influences on the effect of ouabain (OUA) in isolated rat ventricular myocytes. SSA78 or WJS, which can specifically bind with the α{sub 1} or α{sub 2} isoform, were assessed with enzyme linked immunosorbent assay (ELISA), Western blot and immunofluorescent staining methods. Preincubation of myocytes with SSA78 inhibited low OUA affinity pump current but not high OUA affinity pump current, reduced the rise in cytosolic calcium concentration ([Ca{sup 2+}]{sub i}), attenuated mitochondrial Ca{sup 2+} overload, restored mitochondrial membrane potential reduction, and delayed the decrease of the myocardial contractile force as well as the occurrence of arrhythmic contraction induced by high concentrations (1 mM) but not low concentrations (1 μM) of OUA. Similarly, preincubation of myocytes with WJS inhibited high OUA affinity pump current, reduced the increase of [Ca{sup 2+}]{sub i} and the contractility induced by 1 μM but not that induced by 1 mM OUA. These results indicate that the H{sub 1}–H{sub 2} domain of the NKA α{sub 1} isoform mediates OUA-induced cardiac toxicity in rat ventricular myocytes, and inhibitors for this binding site may be used as an adjunct to CGs treatment for cardiovascular disease. -- Highlights: ► We prepared two antibodies against the H{sub 1}-H{sub 2} domain of α{sub 1} and α{sub 2} isoforms of NKA. ► The H{sub 1}-H{sub 2} domain of the NKA α{sub 1} isoform mediates OUA-induced cardiac toxicity. ► The H{sub 1}-H{sub 2} domain of the NKA α{sub 2} isoform mediates OUA-induced positive inotropic.

60 APPLIED LIFE SCIENCES↗

HAND transcription factors cooperatively specify the aorta and pulmonary trunk

Congenital heart defects (CHDs) affecting the cardiac outflow tract (OFT) constitute a significant cause of morbidity and mortality. The OFT develops from migratory cell populations which include the cardiac neural crest cells (cNCCs) and secondary heart field (SHF) derived myocardium and endocardium. The related transcription factors HAND1 and HAND2 have been implicated in human CHDs involving the OFT. Although Hand1 is expressed within the OFT, Hand1 NCC-specific conditional knockout mice (H1CKOs) are viable. Here we show that these H1CKOs present a low penetrance of OFT phenotypes, whereas SHF-specific Hand1 ablation does not reveal any cardiac phenotypes. Further, HAND1 and HAND2 appear functionally redundant within the cNCCs, as a reduction/ablation of Hand2 on an NCC-specific H1CKO background causes pronounced OFT defects. Double conditional Hand1 and Hand2 NCC knockouts exhibit persistent truncus arteriosus (PTA) with 100% penetrance. NCC lineage-tracing and Sema3c in situ mRNA expression reveal that Sema3c-expressing cells are mis-localized, resulting in a malformed septal bridge within the OFTs of H1CKO;H2CKO embryos. Interestingly, Hand1 and Hand2 also genetically interact within the SHF, as SHF H1CKOs on a heterozygous Hand2 background exhibit Ventricular Septal Defects (VSDs) with incomplete penetrance. Previously, we identified a BMP, HAND2, and GATA-dependent Hand1 OFT enhancer sufficient to drive reporter gene expression within the nascent OFT and aorta. Using these transcription inputs as a probe, we identify a novel Hand2 OFT enhancer, suggesting that a conserved BMP-GATA dependent mechanism transcriptionally regulates both HAND factors. These findings support the hypothesis that HAND factors interpret BMP signaling within the cNCCs to cooperatively coordinate OFT morphogenesis.

59 BASIC BIOLOGICAL SCIENCES↗

De-ubiquitination of p300 by USP12 Critically Enhances METTL3 Expression and Ang II-induced cardiac hypertrophy

Highlights: • The expression of USP12 is increased in Ang II-induced cardiac hypertrophy in vitro and in vivo. • USP12 aggravates Ang II-induced cardiomyocyte hypertrophy via upregulating METTL3. • USP12 promoted METTL3 expression via modulating p300. • USP12 suppresses the ubiquitination of p300 to block its degradation. Stresses, such as neurohumoral activation, induced pathological cardiac hypertrophy is the main risk factor for heart failure. The ubiquitin-proteasome system (UPS) plays a key role in maintaining protein homeostasis and cardiac function. However, research on the role and mechanism of deubiquitinating enzymes (DUBs) in cardiac hypertrophy is limited. Here, we observe that the deubiquitinating enzyme ubiquitin-specific protease 12(USP12) is upregulated in Ang II-induced hypertrophic hearts and primary neonatal rat cardiomyocytes (NRCMs). Inhibition of USP12 ameliorate Ang II-induced myocardial hypertrophy, while overexpression of USP12 have the opposite effect. USP12 deficiency also significantly attenuate the phenotype of Ang II-induced cardiac hypertrophy in vivo. Moreover, we demonstrate that USP12 aggravate Ang II-induced cardiac hypertrophy by enhancing METTL3, a methyltransferase which catalyze N{sup 6}-methyladenosine (m{sup 6}A) modification on messenger RNA and acts as a harmful factor in pathological cardiac hypertrophy. Upregulation of METTL3 reverse the reduction of myocardial hypertrophy induced by USP12 silencing in NRCMs. In contrast, knockdown of METTL3 attenuate the aggravation of myocardial hypertrophy in USP12-overexpressing NRCMs. Furthermore, we discover that USP12 promote the expression of METTL3 via upregulating p300. Mechanistically, USP12 binds and stabilizes p300, thereby activating the transcription of its downstream gene METTL3. Finally, our data show that USP12 is partially dependent on the stabilization of p300 to activate METTL3 expression and promote myocardial hypertrophy. Taken together, our results demonstrate that USP12 acts as a pro-hypertrophic deubiquitinating enzyme via enhancing p300/METTL3 axis, indicating that targeting USP12 could be a potential treatment strategy for pathological cardiac hypertrophy.

60 APPLIED LIFE SCIENCES↗

Modality comparison for small animal radiotherapy: A simulation study

Purpose: Small animal radiation therapy has advanced significantly in recent years. Whereas in the past dose was delivered using a single beam and a lead shield for sparing of healthy tissue, conformal doses can be now delivered using more complex dedicated small animal radiotherapy systems with image guidance. The goal of this paper is to investigate dose distributions for three small animal radiation treatment modalities. Methods: This paper presents a comparison of dose distributions generated by the three approaches—a single-field irradiator with a 200 kV beam and no image guidance, a small animal image-guided conformal system based on a modified microCT scanner with a 120 kV beam developed at Stanford University, and a dedicated conformal system, SARRP, using a 220 kV beam developed at Johns Hopkins University. The authors present a comparison of treatment plans for the three modalities using two cases: a mouse with a subcutaneous tumor and a mouse with a spontaneous lung tumor. A 5 Gy target dose was calculated using the EGSnrc Monte Carlo codes. Results: All treatment modalities generated similar dose distributions for the subcutaneous tumor case, with the highest mean dose to the ipsilateral lung and bones in the single-field plan (0.4 and 0.4 Gy) compared to the microCT (0.1 and 0.2 Gy) and SARRP (0.1 and 0.3 Gy) plans. The lung case demonstrated that due to the nine-beam arrangements in the conformal plans, the mean doses to the ipsilateral lung, spinal cord, and bones were significantly lower in the microCT plan (2.0, 0.4, and 1.9 Gy) and the SARRP plan (1.5, 0.5, and 1.8 Gy) than in single-field irradiator plan (4.5, 3.8, and 3.3 Gy). Similarly, the mean doses to the contralateral lung and the heart were lowest in the microCT plan (1.5 and 2.0 Gy), followed by the SARRP plan (1.7 and 2.2 Gy), and they were highest in the single-field plan (2.5 and 2.4 Gy). For both cases, dose uniformity was greatest in the single-field irradiator plan followed by the SARRP plan due to the sensitivity of the lower energy microCT beam to target heterogeneities and image noise. Conclusions: The two treatment planning examples demonstrate that modern small animal radiotherapy techniques employing image guidance, variable collimation, and multiple beam angles deliver superior dose distributions to small animal tumors as compared to conventional treatments using a single-field irradiator. For deep-seated mouse tumors, however, higher-energy conformal radiotherapy could result in higher doses to critical organs compared to lower-energy conformal radiotherapy. Treatment planning optimization for small animal radiotherapy should therefore be developed to take full advantage of the novel conformal systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the interplay effects with proton scanning beams in stage III lung cancer

Purpose: To assess the dosimetric impact of interplay between spot-scanning proton beam and respiratory motion in intensity-modulated proton therapy (IMPT) for stage III lung cancer. Methods: Eleven patients were sampled from 112 patients with stage III nonsmall cell lung cancer to well represent the distribution of 112 patients in terms of target size and motion. Clinical target volumes (CTVs) and planning target volumes (PTVs) were defined according to the authors' clinical protocol. Uniform and realistic breathing patterns were considered along with regular- and hypofractionation scenarios. The dose contributed by a spot was fully calculated on the computed tomography (CT) images corresponding to the respiratory phase that the spot is delivered, and then accumulated to the reference phase of the 4DCT to generate the dynamic dose that provides an estimation of what might be delivered under the influence of interplay effect. The dynamic dose distributions at different numbers of fractions were compared with the corresponding 4D composite dose which is the equally weighted average of the doses, respectively, computed on respiratory phases of a 4DCT image set. Results: Under regular fractionation, the average and maximum differences in CTV coverage between the 4D composite and dynamic doses after delivery of all 35 fractions were no more than 0.2% and 0.9%, respectively. The maximum differences between the two dose distributions for the maximum dose to the spinal cord, heart V40, esophagus V55, and lung V20 were 1.2 Gy, 0.1%, 0.8%, and 0.4%, respectively. Although relatively large differences in single fraction, correlated with small CTVs relative to motions, were observed, the authors' biological response calculations suggested that this interfractional dose variation may have limited biological impact. Assuming a hypofractionation scenario, the differences between the 4D composite and dynamic doses were well confined even for single fraction. Conclusions: Despite the presence of interplay effect, the delivered dose may be reliably estimated using the 4D composite dose. In general the interplay effect may not be a primary concern with IMPT for lung cancers for the authors' institution. The described interplay analysis tool may be used to provide additional confidence in treatment delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of ray profile modeling on resolution recovery in clinical CT

Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. However, among vendors and researchers, there is no consensus of how to best achieve these goals. The authors are focusing on the aspect of geometric ray profile modeling, which is realized by some algorithms, while others model the ray as a straight line. The authors incorporate ray-modeling (RM) in nonregularized iterative reconstruction. That means, instead of using one simple single needle beam to represent the x-ray, the authors evaluate the double integral of attenuation path length over the finite source distribution and the finite detector element size in the numerical forward projection. Our investigations aim at analyzing the resolution recovery (RR) effects of RM. Resolution recovery means that frequencies can be recovered beyond the resolution limit of the imaging system. In order to evaluate, whether clinical CT images can benefit from modeling the geometrical properties of each x-ray, the authors performed a 2D simulation study of a clinical CT fan-beam geometry that includes the precise modeling of these geometrical properties. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and a Forbild thorax phantom with circular resolution patterns representing calcifications in the heart region are simulated. An FBP reconstruction with a Ram–Lak kernel is used as a reference reconstruction. The FBP is compared to iterative reconstruction techniques with and without RM: An ordered subsets convex (OSC) algorithm without any RM (OSC), an OSC where the forward projection is modeled concerning the finite focal spot and detector size (OSC-RM) and an OSC with RM and with a matched forward and backprojection pair (OSC-T-RM, T for transpose). In all cases, noise was matched to be able to focus on comparing spatial resolution. The authors use two different simulation settings. Both are based on the geometry of a typical clinical CT system (0.7 mm detector element size at isocenter, 1024 projections per rotation). Setting one has an exaggerated source width of 5.0 mm. Setting two has a realistically small source width of 0.5 mm. The authors also investigate the transition from setting one to two. To quantify image quality, the authors analyze line profiles through the resolution patterns to define a contrast factor (CF) for contrast-resolution plots, and the authors compare the normalized cross-correlation (NCC) with respect to the ground truth of the circular resolution patterns. To independently analyze whether RM is of advantage, the authors implemented several iterative reconstruction algorithms: The statistical iterative reconstruction algorithm OSC, the ordered subsets simultaneous algebraic reconstruction technique (OSSART) and another statistical iterative reconstruction algorithm, denoted with ordered subsets maximum likelihood (OSML) algorithm. All algorithms were implemented both without RM (denoted as OSC, OSSART, and OSML) and with RM (denoted as OSC-RM, OSSART-RM, and OSML-RM). Results: For the unrealistic case of a 5.0 mm focal spot the CF can be improved by a factor of two due to RM: the 4.2 LP/cm bar pattern, which is the first bar pattern that cannot be resolved without RM, can be easily resolved with RM. For the realistic case of a 0.5 mm focus, all results show approximately the same CF. The NCC shows no significant dependency on RM when the source width is smaller than 2.0 mm (as in clinical CT). From 2.0 mm to 5.0 mm focal spot size increasing improvements can be observed with RM. Conclusions: Geometric RM in iterative reconstruction helps improving spatial resolution, if the ray cross-section is significantly larger than the ray sampling distance. In clinical CT, however, the ray is not much thicker than the distance between neighboring ray centers, as the focal spot size is small and detector crosstalk is negligible, due to reflective coatings between detector elements. Therefore,RM appears not to be necessary in clinical CT to achieve resolution recovery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relationship between early diastolic intraventricular pressure gradients, an index of elastic recoil, and improvements in systolic and diastolic function

BACKGROUND: Early diastolic intraventricular pressure gradients (IVPGs) have been proposed to relate to left ventricular (LV) elastic recoil and early ventricular "suction." Animal studies have demonstrated relationships between IVPGs and systolic and diastolic indices during acute ischemia. However, data on the effects of improvements in LV function in humans and the relationship to IVPGs are lacking. METHODS AND RESULTS: Eight patients undergoing CABG and/or infarct exclusion surgery had a triple-sensor high-fidelity catheter placed across the mitral valve intraoperatively for simultaneous recording of left atrial (LA), basal LV, and apical LV pressures. Hemodynamic data obtained before bypass were compared with those with similar LA pressures and heart rates obtained after bypass. From each LV waveform, the time constant of LV relaxation (tau), +dP/dt(max), and -dP/dt(max) were determined. Transesophageal echocardiography was used to determined end-diastolic (EDV) and end-systolic (ESV) volumes and ejection fractions (EF). At similar LA pressures and heart rates, IVPG increased after bypass (before bypass 1.64+/-0.79 mm Hg; after bypass 2.67+/-1.25 mm Hg; P<0.01). Significant improvements were observed in ESV, as well as in apical and basal +dP/dt(max), -dP/dt(max), and tau (each P<0.05). Overall, IVPGs correlated inversely with both ESV (IVPG=-0.027[ESV]+3.46, r=-0.64) and EDV (IVPG=-0.027[EDV]+4.30, r=-0.70). Improvements in IVPGs correlated with improvements in apical tau (Deltatau =5.93[DeltaIVPG]+4.76, r=0.91) and basal tau (Deltatau =2.41[DeltaIVPG]+5.13, r=-0.67). Relative changes in IVPGs correlated with changes in ESV (DeltaESV=-0.97[%DeltaIVPG]+23.34, r=-0.79), EDV (DeltaEDV=-1.16[%DeltaIVPG]+34.92, r=-0.84), and EF (DeltaEF=0.38[%DeltaIVPG]-8.39, r=0.85). CONCLUSIONS: Improvements in LV function also increase IVPGs. These changes in IVPGs, suggestive of increases in LV suction and elastic recoil, correlate directly with improvements in LV relaxation and ESV.

Non-NASA Center↗

Higher sympathetic nerve activity during ventricular (VVI) than during dual-chamber (DDD) pacing

OBJECTIVES: We determined the short-term effects of single-chamber ventricular pacing and dual-chamber atrioventricular (AV) pacing on directly measured sympathetic nerve activity. BACKGROUND: Dual-chamber AV cardiac pacing results in greater cardiac output and lower systemic vascular resistance than does single-chamber ventricular pacing. However, it is unclear whether these hemodynamic advantages result in less sympathetic nervous system outflow. METHODS: In 13 patients with a dual-chamber pacemaker, we recorded the electrocardiogram, noninvasive arterial pressure (Finapres), respiration and muscle sympathetic nerve activity (microneurography) during 3 min of underlying basal heart rate and 3 min of ventricular and AV pacing at rates of 60 and 100 beats/min. RESULTS: Arterial pressure was lowest and muscle sympathetic nerve activity was highest at the underlying basal heart rate. Arterial pressure increased with cardiac pacing and was greater with AV than with ventricular pacing (change in mean blood pressure +/- SE: 10 +/- 3 vs. 2 +/- 2 mm Hg at 60 beats/min; 21 +/- 5 vs. 14 +/- 2 mm Hg at 100 beats/min; p < 0.05). Sympathetic nerve activity decreased with cardiac pacing and the decline was greater with AV than with ventricular pacing (60 beats/min -40 +/- 11% vs. -17 +/- 7%; 100 beats/min -60 +/- 9% vs. -48 +/- 10%; p < 0.05). Although most patients showed a strong inverse relation between arterial pressure and muscle sympathetic nerve activity, three patients with severe left ventricular dysfunction (ejection fraction < or = 30%) showed no relation between arterial pressure and sympathetic activity. CONCLUSIONS: Short-term AV pacing results in lower sympathetic nerve activity and higher arterial pressure than does ventricular pacing, indicating that cardiac pacing mode may influence sympathetic outflow simply through arterial baroreflex mechanisms. We speculate that the greater incidence of adverse outcomes in patients treated with single-chamber ventricular rather than dual-chamber pacing may be due in part to increased sympathetic nervous outflow.

NASA Discipline Cardiopulmonary↗

A new technique for simultaneous monitoring of electrocardiogram and walking cadence

A new technique for simultaneously recording continuous electrocardiographic (ECG) data and walking step rate (cadence) is described. The ECG and gait signals are recorded on 2 channels of an ambulatory Holter monitor. Footfall is detected using ultrathin, force-sensitive foot switches and is frequency modulated. The footfall signal provides an indication of the subject's activity (walking or standing), as well as the instantaneous walking rate. Twenty-three young and elderly subjects were studied to demonstrate the use of this ECG and gait recorder. High-quality gait signals were obtained in all subjects, and the effects of walking on the electrocardiogram were assessed. Initial investigation revealed the following findings: (1) Although walking rates were similar in young and elderly subjects, the elderly had both decreased heart rate (HR) variability (p < 0.005) and increased cadence variability (p < 0.0001). (2) Overall, there was an inverse relation between HR and cadence variability (r = -0.73). Three elderly subjects with no known cardiac disease had HR and cadence variability similar to those of the young, whereas elderly subjects with history of congestive heart failure were among those with the lowest HR variability and the highest cadence variability. (3) Low-frequency (approximately equal to 0.1 Hz) HR oscillations (frequently observed during standing) persisted during walking in all young subjects. (4) In some subjects, both step rate and HR oscillated at the same low frequency (approximately equal to 0.1 Hz) previously identified with autonomic control of the baroreflex.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Cardiopulmonary↗

Whole breast and excision cavity radiotherapy plan comparison: Conformal radiotherapy with sequential boost versus intensity-modulated radiation therapy with a simultaneously integrated boost

A comparative study was conducted comparing the difference between (1) conformal radiotherapy (CRT) to the whole breast with sequential boost excision cavity plans and (2) intensity-modulated radiation therapy (IMRT) to the whole breast with simultaneously integrated boost to the excision cavity. The computed tomography (CT) data sets of 25 breast cancer patients were used and the results analysed to determine if either planning method produced superior plans. CT data sets from 25 past breast cancer patients were planned using (1) CRT prescribed to 50 Gy in 25 fractions (Fx) to the whole-breast planning target volume (PTV) and 10 Gy in 5Fx to the excision cavity and (2) IMRT prescribed to 60 Gy in 25Fx, with 60 Gy delivered to the excision cavity PTV and 50 Gy delivered to the whole-breast PTV, treated simultaneously. In total, 50 plans were created, with each plan evaluated by PTV coverage using conformity indices, plan maximum dose, lung dose, and heart maximum dose for patients with left-side lesions. CRT plans delivered the lowest plan maximum doses in 56% of cases (average CRT = 6314.34 cGy, IMRT = 6371.52 cGy). They also delivered the lowest mean lung dose in 68% of cases (average CRT = 1206.64 cGy, IMRT = 1288.37 cGy) and V20 in 88% of cases (average CRT = 20.03%, IMRT = 21.73%) and V30 doses in 92% of cases (average CRT = 16.82%, IMRT = 17.97%). IMRT created more conformal plans, using both conformity index and conformation number, in every instance, and lower heart maximum doses in 78.6% of cases (average CRT = 5295.26 cGy, IMRT = 5209.87 cGy). IMRT plans produced superior dose conformity and shorter treatment duration, but a slightly higher planning maximum and increased lung doses. IMRT plans are also faster to treat on a daily basis, with shorter fractionation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Review of deep inspiration breath-hold techniques for the treatment of breast cancer

Radiation treatment to the left breast is associated with increased cardiac morbidity and mortality. The deep inspiration breath-hold technique (DIBH) can decrease radiation dose delivered to the heart and this may facilitate the treatment of the internal mammary chain nodes. The aim of this review is to critically analyse the literature available in relation to breath-hold methods, implementation, utilisation, patient compliance, planning methods and treatment verification of the DIBH technique. Despite variation in the literature regarding the DIBH delivery method, patient coaching, visual feedback mechanisms and treatment verification, all methods of DIBH delivery reduce radiation dose to the heart. Further research is required to determine optimum protocols for patient training and treatment verification to ensure the technique is delivered successfully.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward Transpulmonary Chemoembolization with Degradable Starch Microspheres: Systematic Analysis of Local and Systemic Effects in a Porcine Model

Purpose: To investigate local and systemic effects of transpulmonary chemoembolization (TPCE) with degradable starch microspheres (DSM) and doxorubicin. The long-term goal is to establish DSM-TPCE as a treatment option for pulmonary malignancies. Materials and Methods: Nine pigs underwent TPCE of either the right or left lower lobe pulmonary artery (LLPA) and bland embolization (TPE) of the contralateral LLPA. Before the procedures, macroaggregated albumin (MAA) particles were injected into both LLPAs, to exclude systemic shunting. Pulmonary arterial pressure, heart rate and oxygenation were recorded immediately before and at 1, 3, 5 and 10 min after treatment. To investigate possible nontarget embolization, animals underwent cerebral MRI (cMRI). We killed the animals after a contrast-enhanced chest computed tomography (CT) and performed a pathologic examination at 12 h (3), 24 h (3) and 72 h (3) after treatment. Results: All experiments were technically successful. Mean injected DSM dose until stasis was similar in TPCE and TPE (4.3 ± 1.4 vs. 4.0 ± 1.4 mL). Pulmonary arterial pressure increased significantly 3 min after treatment (TPE: 17 ± 5 vs. 27 ± 7 mmHg; TPCE: 22 ± 6 vs. 36 ± 8 mmHg). No significant changes in heart rate or peripheral oxygenation levels occurred. We observed no evidence of structural lung damage or permanent perfusion disruption on CT. MAA test injection and cMRI revealed no shunting or nontarget embolization. The pathologic assessment revealed nonspecific local inflammation of the lung parenchyma. Conclusion: In this large-animal model, TPCE and TPE appear feasible and safe. We observed a mild increase in pulmonary arterial pressure. Nontarget embolization did not occur. TPCE, as well as TPE, did not cause structural damage to the normal lung parenchyma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Myocardial PET/CT Receptor Imaging and Potential Therapeutic Targets

Purpose of the Review: Activation of myocardial cannabinoid type 1 receptors (CB1-R) and/or angiotensin II type 1 receptors (AT1-R) likely plays an important mechanistic role in determining the left-ventricular remodeling process in systolic heart failure. We provide an overview on novel radiotracer probes and positron emission tomography (PET)/computed tomography (CT) imaging to noninvasively probe the expression of myocardial CB1-R and/or AT1-R. Recent Findings: Recent translational investigations have demonstrated the feasibility of {sup 11}C-OMAR or {sup 11}C-KR31173 and PET/CT to image and quantify myocardial CB1-R and/or AT1-R expression, respectively. There is an increasing understanding of the mechanisms of activated myocardial CB1-R and/or AT1-R to influence the left-ventricular remodeling process in systolic heart failure in different disease entities. Summary: The review summarizes contributions of PET to image myocardial CB1-R and AT1-R expression that may have the potential to serve as a target to tailor preventive medical care in the individual patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the Road to Regeneration: “Tools” and “Routes” Towards Efficient Cardiac Cell Therapy for Ischemic Cardiomyopathy

Purpose of Review: Cardiac regenerative medicine is a field bridging together biotechnology and surgical science. In this review, we present the explored surgical roads to cell delivery and the known effects of each delivery method on cell therapy efficiency. We also list the more recent clinical trials, exploring the safety and efficacy of delivery routes used for cardiac cell therapy approaches. Recent Findings: There is no consensus in defining which way is the most suitable for the delivery of the different therapeutic cell types to the damaged heart tissue. In addition, it emerged that the “delivery issue” has not been systematically addressed in each clinical trial and for each and every cell type capable of cardiac repair. Summary: Cardiac damage occurring after an ischemic insult triggers a cascade of cellular events, eventually leading to heart failure through fibrosis and maladaptive remodelling. None of the pharmacological or medical interventions approved so far can rescue or reverse this phenomenon, and cardiovascular diseases are still the leading cause of death in the western world. Therefore, for nearly 20 years, regenerative medicine approaches have focused on cell therapy as a promising road to pursue, with numerous preclinical and clinical testing of cell-based therapies being studied and developed. Nonetheless, consistent clinical results are still missing to reach consensus on the most effective strategy for ischemic cardiomyopathy, based on patient selection, diagnosis and stage of the disease, therapeutic cell type, and delivery route.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of cardiac reverse remodeling after cardiac resynchronization therapy assessed by myocardial perfusion imaging on ventricular arrhythmia

Background: Although cardiac resynchronization therapy (CRT) has been a useful treatment of heart failure, patients with CRT are still in risk of sudden cardiac death due to ventricular arrhythmia. The aim of this study was to investigate the impact of cardiac reverse remodeling after CRT on the prevalence of ventricular tachycardia or fibrillation (VT/VF). Methods and Results: Forty-one heart failure patients (26 men, age 66 ± 10 years), who were implanted with CRT for at least 12 months, were enrolled. All patients received myocardial perfusion imaging (MPI) under CRT pacing to evaluate left ventricle (LV) function, dyssynchrony, and scar. VT/VF episodes during the follow-up period after MPI were recorded by the CRT devices. Sixteen patients (N = 16/41, 39%) were found to have VT/VF. Multivariate Cox regression analysis and receiver operating characteristic curve analysis showed that five risk factors were significant predictors of VT/VF, including increased left ventricle ejection fraction (LVEF) by ≤7% after CRT, low LVEF after CRT (≤30%), change of intrinsic QRS duration (iQRSd) by ≤7 ms, wide iQRSd after CRT (≥121 ms), and high systolic dyssynchrony after CRT (phase standard deviation ≥45.6°). For those patients with all of the 5 risk factors, 85.7% or more developed VT/VF. Conclusions: The characteristics of cardiac reverse remodeling after CRT as assessed by MPI are associated with the prevalence of ventricular arrhythmia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The high matrix acquisition technique for imaging of atherosclerotic plaque inflammation in fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography with time-of-flight: Phantom study

Background: Motion artifact and partial volume effect caused underestimation of coronary plaque inflammation. This study evaluated the high matrix acquisition technique using time-of-flight (TOF) positron emission tomography/computed tomography for imaging of atherosclerotic plaque inflammation with fluorine-18 fluorodeoxyglucose in small and moving phantoms. Methods and Results: All images were reconstructed using a conventional algorithm without TOF (4 × 4 × 4 mm{sup 3} voxel size) and a high matrix algorithm with TOF (2 × 2 × 2 mm{sup 3} voxel size). Microsphere phantoms of 10, 7.9, 6.2, 5.0, and 4.0 mm diameters were acquired in 3-dimensional list-mode for 30 minutes. A heart phantom mimicking cardiac motion consisted of a hot spot simulating a plaque (φ 4 mm, φ 2 mm) on the outside of the left ventricle. In the microsphere and heart phantom study, visual discrimination, maximum activity, and target-to-background ratio using the high matrix algorithm with TOF were better than those using the conventional algorithm without TOF. Conclusion: The high matrix algorithm with TOF improves detection of small targets in phantoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗