Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Resolutions Optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Chandra Discovery of a Candidate Hyperluminous X-Ray Source in MCG+11-11-032

We present a multiwavelength analysis of MCG+11-11-032, a nearby active galactic nucleus (AGN), with a unique classification as being both a binary and a dual AGN candidate. With new Chandra observations, we aim to resolve any dual AGN system via imaging data and search for signs of a binary AGN via analysis of the X-ray spectrum. Analyzing the Chandra spectrum, we find no evidence of the previously suggested double-peaked Fe Kα lines; the spectrum is instead best fit by an absorbed power law with a single Fe Kα line, as well as an additional line centered at ≈7.5 keV. The Chandra observation reveals faint, soft, and extended X-ray emission, possibly linked to low-level nuclear outflows. Further analysis shows evidence for a compact hard source—MCG+11-11-032 X2—located 3.″3 from the primary AGN. Modeling MCG+11-11-032 X2 as a compact source, we find that it is relatively luminous (L2–10 keV=1.5−0.5+0.9×1041erg s$^{−1}$), and the location is coincident with a compact and off-nuclear source resolved in Hubble Space Telescope infrared (F105W) and optical (F621M, F547M) bands. Pairing our X-ray results with a 144 MHz radio detection at the host galaxy location, we observe X-ray and radio properties similar to those of ESO 243-49 HLX-1, suggesting that MCG+11-11-032 X2 may be a hyperluminous X-ray source. This detection with Chandra highlights the importance of a high-resolution X-ray imager as well as how previous binary AGN candidates detected with large-aperture instruments can benefit from high-resolution follow-up. Future spatially resolved optical spectra, and deeper X-ray observations, can better constrain the origin of MCG+11-11-032 X2.

79 ASTRONOMY AND ASTROPHYSICS↗

New X-ray and optical observations of the X-ray discovered QSO-galaxy pair 1E 0104.2 + 3153

New X-ray and optical observations are presented of the QSO-galaxy pair 1E 0104.2 + 3153, originally discovered as a serendipitous source in the Einstein Observatory Medium Sensitivity Survey (Gioia et al., 1984). Results from an extremely deep Exosat observation are used to suggest that the QSO rather than the compact group of galaxies is the optical counterpart of the IPC source. High-resolution (1-A) spectroscopy of the broad-absorption-line QSO, which fails to confirm the Ca II H and K absorption features reported by Stocke et al., (1984), is presented and discussed. The presence of broad absorption lines in the QSO spectrum may indicate that intrinsic absorption is the cause of the nondetection of this source in the soft Exosat energy band. Optical monitoring of the QSO over a 2-yr period indicates variability. Possible interpretations of this phenomenon are intrinsic luminosity variation or a cessation of a gravitational lensing effect acting at the time of the Einstein observation.

Gioia, I. M.↗

High Resolution UV Spectroscopy of H2 and N2 Applied to Observations of the Planets by Spacecraft

The next generation of high resolution UV imaging spacecraft are being prepared for studying the airglow and aurora of the Earth, the other terrestrial planets and the Jovian planets. To keep pace with these technological improvements we have developed a laboratory program to provide electron impact collision cross sections of the major molecular planetary gases (H2, N2, CO2, O2, and CO). Spectra under optically thin conditions have been measured with a high resolution (lambda/delta(lambda) = 50000) UV spectrometer in tandem with electron impact collision chamber. High resolution spectra of the Lyman and Wemer band systems of H2 have been obtained and modeled. Synthetic spectral intensities based on the J-dependent transition probabilities that include ro-vibronic perturbations are in very good agreement with experimental intensities. The kinetic energy distribution of H(2p,3p) atoms resulting from electron impact dissociation of H2 has been measured. The distribution is based on the first measurement of the H Lyman-alpha (H L(alpha)) and H Lyman-beta (H L(beta)) emission line Doppler profiles. Electron impact dissociation of H2 is believed to be one of the major mechanisms leading to the observed wide profile of H L-alpha from Jupiter aurora by the Hubble Space Telescope (HST). Analysis of the deconvolved line profile of H L-alpha reveals the existence of a narrow line peak (40 mA FWHM) and a broad pedestal base (240 mA FWHM). The band strengths of the electron excited N2 (C(sup 3) Pi(sub(upsilon) - B(sup 3)Pi(sub g)) second positive system have been measured in the middle ultraviolet. We report a quantitative measurement of the predissociation fraction 0.15 +/- 01(sup .045, sub .01) at 300 K in the N2 c'(sub )4 (1)sigma(sup +, sub g) - x(1)sigma(sup +, sub g)(00) band, with an experimental determination of rotational line strengths to be used to understand N2 EUV emission from Titan, Triton and the Earth.

Ajello, J.↗

A polarimeter for the high resolution ultraviolet spectrometer/polarimeter

The design requirements of the polarimeter were established by the scientific optical objectives of the experiment to be launched aboard the Solar Max Mission which will study active solar regions. The polarization of the light is accomplished by a rotating magnesium fluoride quarter wave plate. The quarter wave plates are rotated in 22 1/2 degree steps about an axis coincidental with the light beam. As the light beam passes through the wave plate, the transformation that occurs can be expressed by mathematical equations. By having the wave plates calibrated, the data obtained from solar flares can be analyzed and meaningful information provided to the investigators. The polarimeter has two wave plates with different optical characteristics to provide both redundancy and versatility. A four mirror polarizer was added behind one wave plate to provide additional polarization. The mechanical design, testing, and operation of the polarimeter for the high resolution ultraviolet spectrometer/polarimeter are described.

Calvert, J. A.↗

PtychoShelves , a versatile high-level framework for high-performance analysis of ptychographic data

Over the past decade, ptychography has been proven to be a robust tool for non-destructive high-resolution quantitative electron, X-ray and optical microscopy. It allows for quantitative reconstruction of the specimen's transmissivity, as well as recovery of the illuminating wavefront. Additionally, various algorithms have been developed to account for systematic errors and improved convergence. With fast ptychographic microscopes and more advanced algorithms, both the complexity of the reconstruction task and the data volume increase significantly. PtychoShelves is a software package which combines high-level modularity for easy and fast changes to the data-processing pipeline, and high-performance computing on CPUs and GPUs.

97 MATHEMATICS AND COMPUTING↗

Report of the facility definition team spacelab UV-Optical Telescope Facility

Scientific requirements for the Spacelab Ultraviolet-Optical Telescope (SUOT) facility are presented. Specific programs involving high angular resolution imagery over wide fields, far ultraviolet spectroscopy, precisely calibrated spectrophotometry and spectropolarimetry over a wide wavelength range, and planetary studies, including high resolution synoptic imagery, are recommended. Specifications for the mounting configuration, instruments for the mounting configuration, instrument mounting system, optical parameters, and the pointing and stabilization system are presented. Concepts for the focal plane instruments are defined. The functional requirements of the direct imaging camera, far ultraviolet spectrograph, and the precisely calibrated spectrophotometer are detailed, and the planetary camera concept is outlined. Operational concepts described in detail are: the makeup and functions of shuttle payload crew, extravehicular activity requirements, telescope control and data management, payload operations control room, orbital constraints, and orbital interfaces (stabilization, maneuvering requirements and attitude control, contamination, utilities, and payload weight considerations).

Source record↗

WE-AB-BRB-02: Development of a Micro-Sized Dosimeter for Real-Time Dose Monitoring and Small Field Dosimetry

Purpose: To investigate a miniature optical dosimeter for real-time, high-resolution dosimetry, and explore its potential applications for in vivo measurements and small field dosimetry. Methods: A micro-sized hemispherical (400 µm radius) scintillating detector was constructed from lanthanide activated phosphors doped with Europium (GOS:Eu) and encapsulated in a 17 gauge plastic catheter. A photon counting PMT and CCD-chip spectrometer were used to detect signals emitted from the detector. A single band-passing spectral approach (630nm) was implemented to discriminate the micro-phosphor optical signal from background signals (Cerenkov radiation) in the optical fiber. To test real-time monitoring capabilities, a 3D-printed phantom was used to detect an 192Ir HDR brachytherapy source at locations ranging from 1 to 4 cm radially and 12 cm along the travel axis of the HDR wire. To test the application of the micro-sized detector for small field dosimetry, the linearity of detector was characterized through irradiation of 6MV photon beam at dose-rates ranging from 100 to 600 MU, and the effect of field size was characterized through detections of beams ranging from 30×30 to 1×1 cm2 size. Results: With a 1 second integration time for the spectrometer, the recorded measurements indicated that the micro-sized detector allowed accurate detection of source position at distances of up to 6 cm along the axis of travel in water. EB measurements showed that the detected signal was linearly correlated with dose rate (R{sup 2} = 0.99). The crossbeam profile was determined with a step size of ∼500 µm. Conclusion: Miniaturization of optical dosimeters is shown to be possible through the construction of lanthanide activated doped phosphors detectors. The small size of the detector makes it amenable to a variety of applications, including real-time dose delivery verification during HDR brachytherapy and EB beam calibrations in small fields.

60 APPLIED LIFE SCIENCES↗

Instrument Development for X-Ray Astronomy

Current x-ray observatories such as Chandra and XMM-Newton have delivered spectacular results at soft-x-ray energies thanks to their grazing incidence mirrors. To continue these advances necessitates the development of mirrors with even larger collecting areas, yet within manageable weights and budgets, and focal detectors with improved energy resolution. At higher energies where x-ray critical-grazing angles become very small, x-ray optics have typically not been employed and thus this region remains relatively unexplored at high sensitivity levels and fine angular resolutions. This situation is changing with the development of hard-x-ray optics carried aloft by high-altitude balloons, which promise to bring about dramatic advances. This presentation will review developments in all these areas.

Ramsey, Brian↗

The Development of a Deflectometer for Accurate Surface Figure Metrology

Marshall Space Flight Center is developing the method of direct fabrication for high resolution full-shell x-ray optics. In this technique the x-ray optics axial profiles are figured and polished using a computer-controlled ZeekoIRP600X polishing machine. Based on the Chandra optics fabrication history about one third of the manufacturing time is spent on moving a mirror between fabrication and metrology sites, reinstallation and alignment with either the metrology or fabrication instruments. Also, the accuracy of the alignment significantly affects the ultimate accuracy of the resulting mirrors. In order to achieve higher convergence rate it is highly desirable to have a metrology technique capable of in situ surface figure measurements of the optics under fabrication, so the overall fabrication costs would be greatly reduced while removing the surface errors due to the re-alignment necessary after each metrology cycle during the fabrication. The goal of this feasibility study is to demonstrate if the Phase Measuring Deflectometry can be applied for in situ metrology of full shell x-ray optics. Examples of the full-shell mirror substrates suitable for the direct fabrication

X-ray optics metrology↗

Cross strip microchannel plate imaging photon counters with high time resolution

We have implemented cross strip readout microchannel plate detectors in 18 mm active area format including open face (UV/particle) and sealed tube (optical) configurations. These have been tested with a field programmable gate array based parallel channel electronics for event encoding which can process high input event rates (> 5 MHz) with high spatial resolution. Using small pore MCPs (6 {micro}m) operated in a pair, we achieve gains of >5 x 10{sup 5} which is sufficient to provide spatial resolution of <35 {micro}m FHWM, with self triggered event timing accuracy of {approx}2 ns for sealed tube optical sensors. A peak quantum efficiency of {approx}19% at 500 nm has been achieved with SuperGenII photocathodes that have response over the 400 nm to 900 nm range. Local area counting rates of up to >200 events/mcp pore sec{sup -1} have been attained, along with image linearity and stability to better than 50 {micro}m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating fusion techniques for multi-sensor satellite image data

Satellite image data fusion is a topic of interest in many areas including environmental monitoring, emergency response, and defense. Typically any single satellite sensor cannot provide all of the benefits offered by a combination of different sensors (e.g., high-spatial but low spectral resolution vs. low-spatial but high spectral, optical vs. SAR). Given the respective strengths and weaknesses of the different types of image data, it is beneficial to fuse many types of image data to extract as much information as possible from the data. Our work focuses on the fusion of multi-sensor image data into a unified representation that incorporates the potential strengths of a sensor in order to minimize classification error. Of particular interest is the fusion of optical and synthetic aperture radar (SAR) images into a single, multispectral image of the best possible spatial resolution. We explore various methods to optimally fuse these images and evaluate the quality of the image fusion by using K-means clustering to categorize regions in the fused images and comparing the accuracies of the resulting categorization maps.

Martin, Benjamin W↗

Tuning a microcavity-coupled terahertz laser

Tunable oscillators are a key component of almost all electronic and photonic systems. Yet, a technology capable of operating in the terahertz (THz)-frequency range and fully suitable for widescale implementation is still lacking. This issue is significantly limiting potential THz applications in gas sensing, high-resolution spectroscopy, hyper-spectral imaging, and optical communications. The THz quantum cascade laser is arguably the most promising solution in terms of output power and spectral purity. In order to achieve reliable, repeatable, and broad tunability, here we exploit the strong coupling between two different cavity mode concepts: a distributed feedback one-dimensional photonic resonator (providing gain) and a mechanically actuated wavelength-size microcavity (providing tuning). The result is a continuously tunable, single-mode emitter covering a 162 GHz spectral range, centered on 3.2 THz. Our source has a few tens of MHz resolution, extremely high differential efficiency, and unprecedented compact and simple design architecture. By unveiling the large potential that lies in this technique, our results provide a robust platform for radically different THz systems exploiting broadly tunable semiconductor lasers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

VII Zw 403: H I STRUCTURE IN A BLUE COMPACT DWARF GALAXY

We present optical (UBVJ), ultraviolet (FUV, NUV), and high-resolution atomic hydrogen (H I) observations of the nearby blue compact dwarf (BCD), VII Zw 403. We find that VII Zw 403 has a relatively high H I mass-to-light ratio for a BCD. The rotation velocity is nominally 10-15 km s{sup -1}, but rises to {approx}20 km s{sup -1} after correction for the {approx}8-10 km s{sup -1} random motions present in the gas. The velocity field is complex, including a variation in the position angle of the major axis going from the northeast to the southwest parts of the galaxy. Our high-resolution H I maps reveal structure in the central gas, including a large, low-density H I depression or hole between the southern and northern halves of the galaxy, coincident with an unresolved X-ray source. Although interactions have been proposed as the triggering mechanism for the vigorous star formation occurring in BCDs, VII Zw 403 does not seem to have been tidally triggered by an external interaction, as we have found no nearby possible perturbers. It also does not appear to fall in the set of galaxies that exhibit a strong central mass density concentration, as its optical scale length is large in comparison to similar systems. However, there are some features that are compatible with an accretion event: optical/H I axis misalignment, a change in position angle of the kinematic axis, and a complex velocity field.

79 ASTRONOMY AND ASTROPHYSICS↗

MO-A-BRD-01: An Investigation of the Dynamic Response of a Novel Acousto-Optic Liquid Crystal Detector for Full-Field Transmission Ultrasound Breast Imaging

Purpose: To characterize the dynamic response of a novel acousto-optic (AO) liquid crystal detector for high-resolution transmission ultrasound breast imaging. Transient and steady-state lesion contrast were investigated to identify optimal transducer settings for our prototype imaging system consistent with the FDA limits of 1 W/cm{sup 2} and 50 J/cm{sup 2} on the incident acoustic intensity and the transmitted acoustic energy flux density. Methods: We have developed a full-field transmission ultrasound breast imaging system that uses monochromatic plane-wave illumination to acquire projection images of the compressed breast. The acoustic intensity transmitted through the breast is converted into a visual image by a proprietary liquid crystal detector operating on the basis of the AO effect. The dynamic response of the AO detector in the absence of an imaged breast was recorded by a CCD camera as a function of the acoustic field intensity and the detector exposure time. Additionally, a stereotactic needle biopsy breast phantom was used to investigate the change in opaque lesion contrast with increasing exposure time for a range of incident acoustic field intensities. Results: Using transducer voltages between 0.3 V and 0.8 V and exposure times of 3 minutes, a unique one-to-one mapping of incident acoustic intensity to steady-state optical brightness in the AO detector was observed. A transfer curve mapping acoustic intensity to steady-state optical brightness shows a high-contrast region analogous to the linear portion of the Hurter-Driffield curves of radiography. Using transducer voltages between 1 V and 1.75 V and exposure times of 90 s, the lesion contrast study demonstrated increasing lesion contrast with increasing breast exposure time and acoustic field intensity. Lesion-to-background contrast on the order of 0.80 was observed. Conclusion: Maximal lesion contrast in our prototype system can be obtained using the highest acoustic field intensity and the longest breast exposure time allowable under FDA standards. Department of Defense (DOD) Breast Cancer Research Program IDEA Award W81XWH-11-1-0332; National Institutes of Health (NIH) Grant T32 EB002103-21 from the National Institute of Biomedical Imaging and Bioengineering (NIBIB)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MOTIS: A Focused Ion Beam Source Based On Laser-Cooled Atoms

We have demonstrated high resolution focused ion beams based on a magneto-optical trap ion source (MOTIS), which takes advantage of the ultra cold temperatures of laser cooled atoms to produce high brightness, low emittance ion beams. We have created focused beams of both Cr{sup +} and Li{sup +} and present secondary electron micrographs obtained with these beams, demonstrating a focal spot size as low as 27 nm at a beam energy of 2 keV. This work shows that the MOTIS can be a useful source for focused ion beams that will open new opportunities for applications in materials characterization and metrology.

43 PARTICLE ACCELERATORS↗

Directed Self-Assembly of the Organic Semiconductor C8-BTBT-C8 in Anodic Aluminum Oxide Nanopores

Controlling the self-assembly of organic semiconductors at the nanoscale is critical for advancing high-performance electronic and photonic devices, yet it remains challenging due to their intrinsic anisotropic crystallization and sensitivity to processing conditions. Here, in this study, we demonstrate that cylindrical nanoconfinement within anodic aluminum oxide membranes provides a versatile platform to precisely tune the molecular orientation and phase behavior of the prototypical organic semiconductor 2,7-dioctyl[1]benzothieno[3,2-b][1]benzothiophene (C8-BTBT-C8). Combining temperature-dependent high-resolution synchrotron X-ray scattering with optical birefringence measurements, we uncover that confinement geometries (pore diameters 25–180 nm) and surface chemistry govern the emergence of distinct smectic A textures, featuring molecular layers either parallel or perpendicular to the pore axis. The competition between axial and radial smectic layering is modulated by pore size, surface hydrophilicity, and thermal history, enabling reversible control over domain orientations and transitions between liquid crystalline and crystalline states. Notably, nanoconfinement stabilizes the smectic phase over an expanded temperature range compared to bulk, while inducing complex multidomain configurations owing to geometric constraints and anchoring conditions. Our results elucidate fundamental mechanisms by which anisotropic nanoscale confinement directs the self-organization of highly conjugated organic molecules, with implications for optimizing directional charge transport and anisotropic optical responses in organic–inorganic hybrid nanoarchitectures. This study establishes nanoconfinement as a powerful strategy to engineer morphology and functional properties in organic semiconducting materials with nanoscale precision.

36 MATERIALS SCIENCE↗

A solar-pumped fluorescence model for line-by-line emission intensities in the B–X, A–X, AND X–X band systems of {sup 12}C{sup 14}N

We present a new quantitative model for detailed solar-pumped fluorescent emission of the main isotopologue of CN. The derived fluorescence efficiencies permit estimation and interpretation of ro-vibrational infrared line intensities of CN in exospheres exposed to solar (or stellar) radiation. Our g-factors are applicable to astronomical observations of CN extending from infrared to optical wavelengths, and we compare them with previous calculations in the literature. The new model enables extraction of rotational temperature, column abundance, and production rate from astronomical observations of CN in the inner coma of comets. Our model accounts for excitation and de-excitation of rotational levels in the ground vibrational state by collisions, solar excitation to the A{sup 2}Π{sub i} and B{sup 2}Σ{sup +} electronically excited states followed by cascade to ro-vibrational levels of X{sup 2}Σ{sup +}, and direct solar infrared pumping of ro-vibrational levels in the X{sup 2}Σ{sup +} state. The model uses advanced solar spectra acquired at high spectral resolution at the relevant infrared and optical wavelengths and considers the heliocentric radial velocity of the comet (the Swings effect) when assessing the exciting solar flux for a given transition. We present model predictions for the variation of fluorescence rates with rotational temperature and heliocentric radial velocity. Furthermore, we test our fluorescence model by comparing predicted and measured line-by-line intensities for X{sup 2}Σ{sup +} (1–0) in comet C/2014 Q2 (Lovejoy), thereby identifying multiple emission lines observed at IR wavelengths.

79 ASTRONOMY AND ASTROPHYSICS↗