Gas sensor based on three dimensional Bi2S3 nanowires network for ammonia detection at room temperature

Highlights: • Three dimensional Bi{sub 2}S{sub 3} nanowires networks. • High response to NH{sub 3} gas. • Good selectivity. • Wide linear range. • Work at room temperature. - Abstract: A film containing three dimensional Bi{sub 2}S{sub 3} nanowires network was obtained using Bi(NO{sub 3}){sub 3} and thioacetamide as starting materials through three steps, namely the chemical synthesis of Bi{sub 2}S{sub 3}, preparation of its sol under ultrasonic condition and crystal self-assembly at 25 °C. The nanowires had diameters of 20–100 nm. The formation mechanism of the 3D nanowires network is the anisotropic growth of Bi{sub 2}S{sub 3}. The sensor based on 3D Bi{sub 2}S{sub 3} nanowires network with an excellent response to ammonia at 30 °C. The response mechanism of the sensor for ammonia is a weak coordination adsorption of ammonia molecule on the Bi{sub 2}S{sub 3} nanowires and the electron is partially transferred from ammonia molecule to bismuth (III) ion. The maximum response of the sensor to ammonia was up to 82.3 and had a good linear range from 30 to 350 ppm concentration, indicating its potential applications in the determination and leak alarm of ammonia.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Leak Detection and H2 Sensor Development for Hydrogen Applications

The objectives of this report are: (1) Develop a low cost, low power, durable, and reliable hydrogen safety sensor for a wide range of vehicle and infrastructure applications; (2) Continually advance test prototypes guided by materials selection, sensor design, electrochemical R&D investigation, fabrication, and rigorous life testing; (3) Disseminate packaged sensor prototypes and control systems to DOE Laboratories and commercial parties interested in testing and fielding advanced prototypes for cross-validation; (4) Evaluate manufacturing approaches for commercialization; and (5) Engage an industrial partner and execute technology transfer. Recent developments in the search for sustainable and renewable energy coupled with the advancements in fuel cell powered vehicles (FCVs) have augmented the demand for hydrogen safety sensors. There are several sensor technologies that have been developed to detect hydrogen, including deployed systems to detect leaks in manned space systems and hydrogen safety sensors for laboratory and industrial usage. Among the several sensing methods electrochemical devices that utilize high temperature-based ceramic electrolytes are largely unaffected by changes in humidity and are more resilient to electrode or electrolyte poisoning. The desired sensing technique should meet a detection threshold of 1% (10,000 ppm) H 2 and response time of {approx_equal}1 min, which is a target for infrastructure and vehicular uses. Further, a review of electrochemical hydrogen sensors by Korotcenkov et.al and the report by Glass et.al suggest the need for inexpensive, low power, and compact sensors with long-term stability, minimal cross-sensitivity, and fast response. This view has been largely validated and supported by the fuel cell and hydrogen infrastructure industries by the NREL/DOE Hydrogen Sensor Workshop held on June 8, 2011. Many of the issues preventing widespread adoption of best-available hydrogen sensing technologies available today outside of cost, derive from excessive false positives and false negatives arising from signal drift and unstable sensor baseline; both of these problems necessitate the need for unacceptable frequent calibration.

08 HYDROGEN↗

Flux Sensor Measurement and Calibration Requirements for High-Intensity Heat Flux Applications: A Trade Study

Stakeholders of CSP and non-CSP high-intensity broadband flux measurements were surveyed and interviewed to obtain flux sensor design and calibration requirements. Existing sensor technologies and existing calibration facilities were then compared against this standard. Stakeholders require a flux sensor designed for >5,000 kW/m2 flux measurements, >1,000 life cycles, <500 ms response time, >60-minute exposure at maximum flux, and <5% measurement uncertainty. Stakeholders also require a sensor with minimal cost, short procurement lead time, and a high-intensity broadband flux calibration. Commercial CSP stakeholders primarily rely on infrared (IR) temperature measurements of receiver equipment to control CSP plant process operation, whereas CSP research and development (R&D) and non-CSP stakeholders rely on accurate flux gauge measurements for a variety of applications. It was determined that existing flux sensor technologies and calibration facilities do not comprehensively meet stakeholder needs. This study suggests a more robust circular foil gauge with a high-intensity solar flux calibration comprehensively meets stakeholder flux measurement needs. Improved circular foil gauge designs and an improved flux sensor calibration facility are discussed.

McLaughlin, Luke (ORCID:0000000303711310)↗

NGEE Arctic Tram: Continuous Soil Moisture and Temperature Measurements across Low- and High-Centered Polygonal Ground, Utqiagvik (Barrow), Alaska, 2014-2016

This data set reports the continuous soil moisture and temperature measurements collected from August of 2014 to September of 2016 along the footprint of the NGEE Arctic Tram. Soil moisture and temperature sensors are installed adjacent to the Tram at 8 locations of varying land surface types across the low-centered and high-centered polygonal ground. While the Tram operates seasonally these soil measurements are recorded year around. Two data files (*.csv) are provided: (1) the original output data file from Campbell Scientific CR1000 data logger, and (2) a reorganized and consistently named version of the same data. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Full-scale Demonstration of Multi-process Sensor at a Cycling PC-fired Boiler

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Predicted and measured temperature compensated surface acoustic wave devices for high-temperature applications

Industrial monitoring and process control, power plants, aerospace industry, military equipment manufacturing, oil and gas industries are examples of businesses in need for high-temperature and harsh environment electronic components and systems. In particular, resonators and filters that operate beyond the 125°C military range upper limit, normally dictated by silicon-based semiconductor devices, are required in applications which demand frequency control, clocking and sensors. In this Letter, temperature compensated surface acoustic wave orientations appropriate for the fabrication of resonators and filters >125°C have been identified through numerical calculations and experimentally confirmed on a commercially available langasite wafer, a piezoelectric crystal which operates at high temperatures. Resonator filters have been designed, fabricated and tested along two orientations, confirming the zero temperature sensitivities at 150 and 300°C. These devices are of great interest for modern harsh environment frequency control, timing and sensor applications.

36 MATERIALS SCIENCE↗

Towards Quantifying and Correlating RTV Intumescence to Entry-Relevant Conditions

Room Temperature Vulcanizing silicone (RTV) is a high-temperature adhesive used as a gap-filler between Thermal Protection System (TPS) tiles for heatshields on numerous missions. It is also adopted to bond instrumentation plugs of temperature and pressure sensors into heatshield’s tiles. While RTV has been traditionally assumed to be a non-porous and non-ablating material, numerous experiments have shown that RTV pyrolyzes and becomes highly porous as it is heated. Experimental data has also shown heating rate-dependent swelling (or intumescence) and shrinking of RTV, these volume changes may cause roughness-induced boundary layer transition. Outgassing and surface oxide formation of RTV upon decomposition also occur, which can be sources of contamination of heat shield sensors. This combination of detrimental effects motivates a critical need to develop a high-fidelity model for RTV ablation. As a first critical step in RTV modeling, a comprehensive material properties database for RTV was collected that account for the lack of data in properties such as pyrolysis char yield, shape change, virgin and char porosity. The next step is to quantify the volume change of RTV as a function of temperature. While this was done in previous campaigns, limited data was collected which showed a possible heating rate dependent intumescent behavior. To further understand the intumescence phenomenon of RTV, numerous dedicated experiments were performed at Beamline 8.3.2 of the Advanced Light Source, where RTV samples were heated while X-ray scans were taken in situ. Micro-Computed Tomography scans were taken in situ for low heating rates (≤ 60 °C/min), whereas continuous radiography scans were taken for higher heating rates (≤ 1500 ºC/min). Unconstrained samples and samples constrained in different holders (quartz, graphite, FiberForm and PICA) were tested to determine the change in intumescence due to confinement. Using deep learning techniques, the tomographies and radiographies are segmented to obtain volume change, porosity, pore size distributions and connectivity. From the results obtained, modifications to the previous RTV intumescence model are proposed, along with preliminary comparisons to testing RTV at high-enthalpy facilities.

RTV↗

In-situ packaging ultra-uniform 3D hematite nanotubes by polyaniline and their improved gas sensing properties

Highlights: • Ultra-uniform 3D α-Fe{sub 2}O{sub 3} nanotubes were packaged by PANI through the two-stage solution processes. • PANI/α-Fe{sub 2}O{sub 3}-based sensor could detect low concentration of acetone (1 ppm) at lower temperature of 180 °C. • The unique structure of α-Fe{sub 2}O{sub 3} support and its synergetic effect with PANI layers improved the sensor performances. - Abstract: This paper reports the PANI (polyaniline)-packaged three-dimensional (3D) α-Fe{sub 2}O{sub 3} nanotubes P/N heterojunction, which was constructed successfully though a facile hydrothermal reaction without adding any surfactant followed by in-situ chemical polymerization in the liquid phase. The structure and morphology of the products were characterized by means of FESEM, XRD, TEM & HRTEM, TGA and FT-IR. Gas sensing test results found that, the PANI/α-Fe{sub 2}O{sub 3} nanocomposite sensor exhibited obviously higher response, lower working temperature (180 °C), fast response and recovery speeds, good selectivity and excellent stability to acetone gas, indicating its promising application for high-performance acetone sensors. The enhanced gas sensing performances can be attributed to the factors like ultra-uniform 3D nanotube-like structure for α-Fe{sub 2}O{sub 3}, the noticeable advantages of PANI, as well as the construction of heterojunction barrier at their interface. The as-prepared PANI/α-Fe{sub 2}O{sub 3} nanocomposite may be also applied in other areas like photocatalysis, water purification, ion batteries, optical devices, and so on.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Program to design, fabricate, test, and deliver a thermal control-mixing control device, phase 1

The development of a sensor capable of detecting temperature changes as a function of viscosity changes, was completed. This type of sensor, consisting of an orifice bridge circuit, resulted in a device with a threshold above internally generated noise of 0.8C (1.5F). Data were obtained using a noise free Freon source provided by an air pressurized bladder. Tests conducted to operate the sensor from a typical Freon centrifugal pump system employing an air bubble accumulator for noise attentuation disclosed the sensor could be used only to sense temperature changes greater than 3.3C (6F) because of the excessively noisy output. This is attributed to the high frequency-pressure fluctuations in the Freon supply to the sensor.

Thurston, T. S.↗

Out-of-pile performance of High Temperature Irradiation Resistant and Cladding Thermocouples

The High Temperature Irradiation Resistant thermocouple (HTIR-TCs) has proven to be the nuclear temperature sensor. It outlast and outperforms all other commercially available thermocouples above 1100 °C inside reactor pressure vessels; also, recent calibration methods have pushed the HTIR-TC to accurately read temperatures through thermal transients during reactor shutdowns and restarts. The new temperature range of HTIR-TCs is from 0 °C to 1650 °C. The main objective of this study is to address manufacturing a more robust TC for handling and inserting into reactor experiments; to also apply the TC to a wider application. The TC has shown to be mainly susceptible to oxygen levels inside the heat treatment and calibration process and it is recommended that O2 levels be brought to as low as possible. However, through modeling efforts the O2 has been found to intercalate only within the first few layers of niobium on the outer sheath. Lastly, multiple materials were used for the sheath and insulators; all with similar outcomes when testing occurred over a long period of time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress Towards Developing Neutron Tolerant Magnetostrictive and Piezoelectric Transducers

Current generation light water reactors (LWRs), sodium cooled fast reactors (SFRs), small modular reactors (SMRs), and next generation nuclear plants (NGNPs) produce harsh environments in and near the reactor core that can severely tax material performance and limit component operational life. To address this issue, several Department of Energy Office of Nuclear Energy (DOE-NE) research programs are evaluating the long duration irradiation performance of fuel and structural materials used in existing and new reactors. In order to maximize the amount of information obtained from Material Testing Reactor (MTR) irradiations, DOE is also funding development of enhanced instrumentation that will be able to obtain in-situ, real-time data on key material characteristics and properties, with unprecedented accuracy and resolution. Such data are required to validate new multi-scale, multi-physics modeling tools under development as part of a science-based, engineering driven approach to reactor development. It is not feasible to obtain high resolution/microscale data with the current state of instrumentation technology. However, ultrasound-based sensors offer the ability to obtain such data if it is demonstrated that these sensors and their associated transducers are resistant to high neutron flux, high gamma radiation, and high temperature. To address this need, the Advanced Test Reactor National Scientific User Facility (ATR-NSUF) is funding an irradiation, led by PSU, at the Massachusetts Institute of Technology Research Reactor to test the survivability of ultrasound transducers. As part of this effort, PSU and collaborators have designed, fabricated, and provided piezoelectric and magnetostrictive transducers that are optimized to perform in harsh, high flux, environments. Four piezoelectric transducers were fabricated with either aluminum nitride, zinc oxide, or bismuth titanate as the active element that were coupled to either Kovar or aluminum waveguides and two magnetostrictive transducers were fabricated with Remendur or Galfenol as the active elements. Pulse-echo ultrasonic measurements of these transducers are made in-situ. This paper will present an overview of the test design including selection criteria for candidate materials and optimization of test assembly parameters, data obtained from both out-of-pile and in-pile testing at elevated temperatures, and an assessment based on initial data of the expected performance of ultrasonic devices in irradiation conditions

Reinhardt1, Brian↗

Flight testing of a fiber optic temperature sensor

A fiber optic temperature sensor (FOTS) system consisting of an optical probe, a flexible fiber optic cable, and an electro-optic signal processor was fabricated to measure the gas temperature in a turbine engine. The optical probe contained an emissive source embedded in a sapphire lightguide coupled to a fiber-optic jumper cable and was retrofitted into an existing thermocouple probe housing. The flexible fiber optic cable was constructed with 200 micron core, polyimide-coated fiber and was ruggedized for an aircraft environment. The electro-optic signal processing unit was used to ratio the intensities of two wavelength intervals and provided an analog output value of the indicated temperature. Subsequently, this optical sensor system was installed on a NASA Dryden F-15 Highly Integrated Digital Electronic Control (HIDEC) Aircraft Engine and several flight tests were conducted. Over the course of flight testing, the FOTS system's response was proportional to the average of the existing thermocouples sensing the changes in turbine engine thermal conditions.

Finney, M. J.↗

Waveguides in Thin Film Polymeric Materials

Results on the fabrication of integrated optical components in polymeric materials using photo printing methods will be presented. Optical waveguides were fabricated by spin coating preoxidized silicon wafers with organic dye/polymer solution followed by soft baking. The waveguide modes were studied using prism coupling technique. Propagation losses were measured by collecting light scattered from the trace of a propagation mode by either scanning photodetector or CCD camera. We observed the formation of graded index waveguides in photosensitive polyimides after exposure of UV light from a mercury arc lamp. By using a theoretical model, an index profile was reconstructed which is in agreement with the profile reconstructed by the Wentzel-Kramers-Brillouin calculation technique using a modal spectrum of the waveguides. Proposed mechanism for the formation of the graded index includes photocrosslinking followed by UV curing accompanied with optical absorption increase. We also developed the prototype of a novel single-arm double-mode interferometric sensor based on our waveguides. It demonstrates high sensitivity to the chance of ambient temperature. The device can find possible applications in aeropropulsion control systems.

Sakisov, Sergey↗

Prediction of STS-107 Hypervelocity Flow Fields about the Shuttle Orbiter with Various Wing Leading Edge Damage

Computations were performed for damaged configurations of the Shuttle Orbiter in support of the STS-107 Columbia accident investigation. Two configurations with missing wing leading-edge reinforced carbon-carbon (RCC) panels were evaluated at conditions just prior to the peak heating trajectory point. The initial configuration modeled the Orbiter with an approximate missing RCC panel 6 to determine whether this damage could result in anomalous temperatures measured during the STS-107 reentry. This missing RCC panel 6 computation was found to produce heating augmentation factors of 5 times the nominal heating rates on the side fuselage with lesser heat increases on the front of the OMS pod. This is consistent with the thermocouple and resistance temperature detector sensors from the STS-107 re-entry which observed off nominal high early in the re-entry trajectory. A second damaged configuration modeled the Orbiter with missing RCC panel 9 and included ingestion of the flow into the outboard RCC channel. This computation lowered the level (only 2 times nominal) and moved the location of the heating augmentation on the leeside fuselage relative to the missing RCC panel 6 configuration. The lesser heating augmentation for missing RCC panel 9 was confined near the wing fuselage juncture. Near nominal heating was predicted on the remainder of the side fuselage with some lower than nominal heating on the front surface of the OMS pod. These results for missing RCC panel 9 are consistent with data from the STS-107 re-entry where the heating augmentation was observed to move off the side fuselage and OMS pod sensors at later times in the trajectory. As this solution requires supersonic mass ingestion into the RCC channel, it is probably not an appropriate model prior to penetration of the flow through the spar into the wing structure. It may, however, be representative of the conditions at later times and could account for the movement of the heating signature on the side fuselage.

Pulsonetti, Maria V.↗

Development of a semigraphitic sulfur-doped ordered mesoporous carbon material for electroanalytical applications

The modification of traditional electrodes with mesoporous carbons is a promising strategy to produce high performance electrodes for electrochemical sensing. The high surface area of mesoporous carbons provides a large number of electroactive sites for binding analytes. Controlling the pore size and structure of mesoporous carbons and modifying their electronic properties via doping offers additional benefits like maximizing transport and tuning the electrochemical processes associated with analyte detection. This work reports a facile method to produce sulfur-doped ordered mesoporous carbon materials (S-OMC) with uniform pore structure, large pore volume, high surface area and semigraphitic structure. The synthesis used thiophenol as a single source of carbon and sulfur, and iron as a catalyst for low temperature carbonization. The S-OMC material was deposited on a glassy carbon electrode and used as a sensor with high sensitivity (11.7 A L mol-1) and selectivity for chloramphenicol detection in presence of other antibiotics. As a proof-of-concept, the sensor was applied to the direct analysis of the drug in reconstituted powdered milk and in commercial eye drops.

36 MATERIALS SCIENCE↗

Research sensors

The work described is part of a program (Englund and Seasholtz, 1988) to develop sensors and sensing techniques for research applications on aircraft turbine engines. In general, the sensors are used to measure the environment at a given location within a turbine engine or to measure the response of an engine component to the imposed environment. Locations of concern are generally in the gas path and, for the most part, are within the hot section. Specific parameters of concern are dynamic gas temperature, heat flux, airfoil surface temperature, and strain on airfoils and combustor liners. To minimize the intrusiveness of surface-mounted sensors, a considerable effort was expended to develop thin-film sensors for surface temperature, strain, and heat flux measurements. In addition, an optical system for viewing the interior of an operating combustor was developed. Most of the work described is sufficiently advanced that the sensors were used and useful data were obtained. The notable exception is the work to develop a high-temperature static strain measuring capability; the work is still in progress.

Englund, David R.↗

Analysis of Upper Air, Ground and Remote Sensing Data For the ATLAS Field Campaign in San Juan, Puerto Rico

The Atlas San Juan Mission was conducted in February 2004 with the main objectives of observing the Urban Heat Island of San Juan, providing high resolution data of the land use for El Yunque Rain Forest and for calibrating remote sensors. The mission was coordinated with NASA staff members at Marshall, Stennis, Goddard, and Glenn. The Airborne Thermal and Land Applications Sensor (ATLAS) from NASA/Stennis, that operates in the visual and IR bands, was used as the main sensor and was flown over Puerto Rico in a Lear 23 jet plane. To support the data gathering effort by the ATLAS sensor, remote sensing observations and upper air soundings were conducted along with the deployment of a number of ground based weather stations and temperature sensors. This presentation focuses in the analysis of this complementary data for the Atlas San Juan Mission. Upper air data show that during the days of the mission the Caribbean mid and high atmospheres were relatively dry and highly stable reflecting positive surface lifted index, a necessary condition to conduct this suborbital campaign. Surface wind patterns at levels below 850mb were dominated by the easterly trades, while the jet stream at the edge of the troposphere dominated the westerly wind at levels above 500mb. The jet stream remained at high latitudes reducing the possibility of fronts. In consequence, only 8.4 mm of precipitation were reported during the entire mission. Observation of soundings located about 150 km apart reflected minimum variations of the boundary layer across the island for levels below 850 meters and a uniform atmosphere for higher levels. The weather stations and the temperature sensors were placed at strategic locations to observe variations across the urban and rural landscapes. Time series plot of the stations' data show that heavily urbanized commercial areas have higher air temperatures than urban and suburban residential areas, and much higher temperatures than rural areas. Temperature differences [dT(U-R)] were obtained by subtracting the values of several stations from a reference urban station, located in the commercial area of San Juan. These time series show that the UHI peaks during the morning between 10:00am and noon to an average of 4.5 C, a temporal pattern not previously observed in similar studies for continental cities. It is also observed a high variability of the UHI with the precipitation patterns even for short events. These results may be a reflection of a large land use density by low level buildings with an apparent absence of significant heat storage effects in the urban areas, and the importance of the surrounding soil and vegetation moisture in controlling the urban tropical climate. The ATLAS data was used to determine albedo and surface temperature patterns on a 10m scale for the study area. These data were used to calibrate the spatial distribution of the surface temperature when using remote sensing images from MODIS (Moderate Resolution Imaging Spectroradiometer). Surface temperatures were estimated using the land surface temperature product MOD11_L2 distributed by the Land Process Distributed Active Archive Center (LP DAAC). These results show the maximum, minimum and average temperatures in San Juan and in the entire Island at a resolution of 1 km. The information retrieved from MODIS for land surface temperatures reflected similar temporal and spatial variations as the weather stations and ATLAS measurements with a highest absolute offset of about 5 C due to the differences between surface and air temperatures.

Gonzalez, J. E.↗

Analysis of Upper Air, Ground and Remote Sensing Data for the ATLAS Field Campaign in San Juan, Puerto Rico

The Atlas San Juan Mission was conducted in February 2004 with the main objectives of observing the Urban Heat Island of San Juan, providing high resolution data of the land use for El Yunque Rain Forest and for calibrating remote sensors. The mission was coordinated with NASA staff members at Marsha& Stennis, Goddard, and Glenn. The Airborne Thermal and Land Applications Sensor (ATLAS) from NASA/Stennis, that operates in the visual and IR bands, was used as the main sensor and was flown over Puerto Rico in a Lear 23 jet plane. To support the data gathering effort by the ATLAS sensor, remote sensing observations and upper air soundings were conducted along with the deployment of a number of ground based weather stations and temperature sensors. This presentation focuses in the analysis of this complementary data for the Atlas San Juan Mission. Upper air data show that during the days of the mission the Caribbean mid and high atmospheres were relatively dry and highly stable reflecting positive surface lifted index, a necessary condition to conduct this suborbital campaign. Surface wind patterns at levels below 850mb were dominated by the easterly trades, while the jet stream at the edge of the troposphere dominated the westerly wind at levels above 500mb. The jet stream remained at high latitudes reducing the possibility of fronts. In consequence, only 8.4 mm of precipitation were reported during the entire mission. Observation of soundings located about 150 km apart reflected minimum variations of the boundary layer across the Island for levels below 850 meters and a uniform atmosphere for higher levels. The weather stations and the temperature sensors were placed at strategic locations to observe variations across the urban and rural landscapes. Time series plot of the stations' data show that heavily urbanized commercial areas have higher air temperatures than urban and suburban residential areas, and much higher temperatures than rural areas. Temperature differences [dT(U-R)] were obtained by subtracting the values of several stations h m a reference urban station, located m the commercial area of San Juan. These time series show that the UHI peaks during the morning between 10:00am and noon to an average of 4.5 C, a temporal pattern not previously observed in similar studies for continental cities. It is also observed a high variability of the UHI with the precipitation patterns even for short events. These results may be a reflection of a large land use density by low level buildings with an apparent absence of significant heat storage effects in the urban areas, and the importance of the surrounding soil and vegetation moisture in controlling the urban tropical climate. The ATLAS data was used to determine albedo and surface temperature patterns on a 10m scale for the study area. These data were used to calibrate the spatial distribution of the surface temperature when using remote sensing images from MODIS (Moderate Resolution Imaging Spectradiometer). Surface temperatures were estimated using the land surface temperature product MODII-L2 distributed by the Land Process Distributed Active Archive Center(LP DAAC). These results show the maximum, minimum and average temperatures in San Juan and in the entire Island at a resolution of 1 km. The information retrieved from MODIS for land surface temperatures reflected similar temporal and spatial variations as the weather stations and ATLAS measurements with a highest absolute offset of about 5 C due to the differences between surface and air temperatures.