Search NASA⌕ Search

SEARCH · Search NASA

Results for “High spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Marine Boundary Layer Cloud Property Retrievals from High-Resolution ASTER Observations: Case Studies and Comparison with Terra MODIS

A research-level retrieval algorithm for cloud optical and microphysical properties is developed for the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) aboard the Terra satellite. It is based on the operational MODIS algorithm. This paper documents the technical details of this algorithm and evaluates the retrievals for selected marine boundary layer cloud scenes through comparisons with the operational MODIS Data Collection 6 (C6) cloud product. The newly developed, ASTERspecific cloud masking algorithm is evaluated through comparison with an independent algorithm reported in Zhao and Di Girolamo (2006). To validate and evaluate the cloud optical thickness (tau) and cloud effective radius (r(sub eff)) from ASTER, the high-spatial-resolution ASTER observations are first aggregated to the same 1000m resolution as MODIS. Subsequently, tau(sub aA) and r(sub eff, aA) retrieved from the aggregated ASTER radiances are compared with the collocated MODIS retrievals. For overcast pixels, the two data sets agree very well with Pearson's product-moment correlation coefficients of R greater than 0.970. However, for partially cloudy pixels there are significant differences between r(sub eff, aA) and the MODIS results which can exceed 10 micrometers. Moreover, it is shown that the numerous delicate cloud structures in the example marine boundary layer scenes, resolved by the high-resolution ASTER retrievals, are smoothed by the MODIS observations. The overall good agreement between the research-level ASTER results and the operational MODIS C6 products proves the feasibility of MODIS-like retrievals from ASTER reflectance measurements and provides the basis for future studies concerning the scale dependency of satellite observations and three-dimensional radiative effects.

marine boundary layer↗

The high energy X-ray probe (HEX-P): Galactic PeVatrons, star clusters, superbubbles, microquasar jets, and gamma-ray binaries

HEX-P is a probe-class mission concept that will combine high spatial resolution X-ray imaging (<10" FWHM) and broad spectral coverage (0.2–80 keV) with an effective area far superior to current facilities (including XMM-Newton and NuSTAR) to enable revolutionary new insights into a variety of important astrophysical problems. With the recent discoveries of over 40 ultra-high-energy gamma-ray sources (detected above 100 TeV) and neutrino emission in the Galactic Plane, we have entered a new era of multi-messenger astrophysics facing the exciting reality of Galactic PeVatrons. In the next decade, as more Galactic PeVatrons and TeV gamma-ray sources are expected to be discovered, the identification of their acceleration and emission mechanisms will be the most pressing issue in both particle and high-energy astrophysics. In this paper, along with its companion papers, we will present that HEX-P is uniquely suited to address important problems in various cosmic-ray accelerators, including Galactic PeVatrons, through investigating synchrotron X-ray emission of TeV–PeV electrons produced by both leptonic and hadronic processes. For Galactic PeVatron candidates and other TeV gamma-ray sources, HEX-P can fill in a large gap in the spectral-energy distributions (SEDs) of many objects observed in radio, soft X-rays, and gamma rays, constraining the maximum energies to which electrons can be accelerated, with implications for the nature of the Galactic PeVatrons and their contributions to the spectrum of Galactic cosmic rays beyond the knee at ~3 PeV. In particular, X-ray observation with HEX-P and TeV observation with CTAO will provide the most powerful multi-messenger diagnostics to identify Galactic PeVatrons and explore a variety of astrophysical shock mechanisms. We present simulations of each class of Galactic TeV–PeV sources, demonstrating the power of both the imaging and spectral capabilities of HEX-P to advance our knowledge of Galactic cosmic-ray accelerators. In addition, we discuss HEX-P’s unique and complementary roles to upcoming gamma-ray and neutrino observatories in the 2030s.

79 ASTRONOMY AND ASTROPHYSICS↗

The high energy X-ray probe (HEX-P): Galactic PeVatrons, star clusters, superbubbles, microquasar jets, and gamma-ray binaries

HEX-P is a probe-class mission concept that will combine high spatial resolution X-ray imaging (<10" FWHM) and broad spectral coverage (0.2–80 keV) with an effective area far superior to current facilities (including XMM-Newton and NuSTAR) to enable revolutionary new insights into a variety of important astrophysical problems. With the recent discoveries of over 40 ultra-high-energy gamma-ray sources (detected above 100 TeV) and neutrino emission in the Galactic Plane, we have entered a new era of multi-messenger astrophysics facing the exciting reality of Galactic PeVatrons. In the next decade, as more Galactic PeVatrons and TeV gamma-ray sources are expected to be discovered, the identification of their acceleration and emission mechanisms will be the most pressing issue in both particle and high-energy astrophysics. In this paper, along with its companion papers, we will present that HEX-P is uniquely suited to address important problems in various cosmic-ray accelerators, including Galactic PeVatrons, through investigating synchrotron X-ray emission of TeV–PeV electrons produced by both leptonic and hadronic processes. For Galactic PeVatron candidates and other TeV gamma-ray sources, HEX-P can fill in a large gap in the spectral-energy distributions (SEDs) of many objects observed in radio, soft X-rays, and gamma rays, constraining the maximum energies to which electrons can be accelerated, with implications for the nature of the Galactic PeVatrons and their contributions to the spectrum of Galactic cosmic rays beyond the knee at ~3 PeV. In particular, X-ray observation with HEX-P and TeV observation with CTAO will provide the most powerful multi-messenger diagnostics to identify Galactic PeVatrons and explore a variety of astrophysical shock mechanisms. We present simulations of each class of Galactic TeV–PeV sources, demonstrating the power of both the imaging and spectral capabilities of HEX-P to advance our knowledge of Galactic cosmic-ray accelerators. In addition, we discuss HEX-P’s unique and complementary roles to upcoming gamma-ray and neutrino observatories in the 2030s.

79 ASTRONOMY AND ASTROPHYSICS↗

Feasibility Study For A Spaceborne Ozone/Aerosol Lidar System

Because ozone provides a shield against harmful ultraviolet radiation, determines the temperature profile in the stratosphere, plays important roles in tropospheric chemistry and climate, and is a health risk near the surface, changes in natural ozone layers at different altitudes and their global impact are being intensively researched. Global ozone coverage is currently provided by passive optical and microwave satellite sensors that cannot deliver high spatial resolution measurements and have particular limitations in the troposphere. Vertical profiling DIfferential Absorption Lidars (DIAL) have shown excellent range-resolved capabilities, but these systems have been large, inefficient, and have required continuous technical attention for long term operations. Recently, successful, autonomous DIAL measurements have been performed from a high-altitude aircraft (LASE - Lidar Atmospheric Sensing Experiment), and a space-qualified aerosol lidar system (LITE - Laser In-space Technology Experiment) has performed well on Shuttle. Based on the above successes, NASA and the Canadian Space Agency are jointly studying the feasibility of developing ORACLE (Ozone Research with Advanced Cooperative Lidar Experiments), an autonomously operated, compact DIAL instrument to be placed in orbit using a Pegasus class launch vehicle.

Campbell, Richard E.↗

The High Energy X-Ray Probe (HEX-P): Galactic PeVatrons, Star Clusters, Superbubbles, Microquasar Jets, and Gamma-Ray Binaries

HEX-P is a probe-class mission concept that will combine high spatial resolution X-ray imaging (<10"FWHM) and broad spectral coverage (0.2--80 keV) with an effective area far superior to current facilities (including XMM-Newton and NuSTAR) to enable revolutionary new insights into a variety of important astrophysical problems. With the recent discoveries of over 40 ultra-high-energy gamma-ray sources (detected above 100 TeV) and neutrino emission in the Galactic Plane, we have entered a new era of multi-messenger astrophysics facing the exciting reality of Galactic PeVatrons. In the next decade, as more Galactic PeVatrons and TeV gamma-ray sources are expected to be discovered, the identification of their acceleration and emission mechanisms will be the most pressing issue in both particle and high-energy astrophysics. In this paper, along with its companion papers (Reynolds et al. 2023, Mori et al. 2023), we will present that HEX-P is uniquely suited to address important problems in various cosmic-ray accelerators, including Galactic PeVatrons, through investigating synchrotron X-ray emission of TeV--PeV electrons produced by both leptonic and hadronic processes. For Galactic PeVatron candidates and other TeV gamma-ray sources, HEX-P can fill in a large gap in the spectral-energy distributions (SEDs) of many objects observed in radio, soft X-rays, and gamma rays, constraining the maximum energies to which electrons can be accelerated, with implications for the nature of the Galactic PeVatrons and their contributions to the spectrum of Galactic cosmic rays beyond the knee at $\sim3$ PeV. In particular, X-ray observation with HEX-P and TeV observation with CTA will provide the most powerful multi-messenger diagnostics to identify Galactic PeVatrons and explore a variety of astrophysical shock mechanisms. We present simulations of each class of Galactic TeV--PeV sources, demonstrating the power of both the imaging and spectral capabilities of HEX-P to advance our knowledge of Galactic cosmic-ray accelerators. In addition, we discuss HEX-P’s unique and complementary roles to upcoming gamma-ray and neutrino observatories in the 2030s.

particle accelerators↗

Characteristics of a RF-Driven Ion Source for a Neutron Generator Used For Associated Particle Imaging

We present recent work on a prototype compact neutron generator for associated particle imaging (API). API uses alpha particles that are produced simultaneously with neutrons in the deuterium-tritium (2D(3T,n)4 alpha) fusion reaction to determine the direction of the neutrons upon exiting the reaction. This method determines the spatial position of each neutron interaction and requires the neutrons to be generated from a small spot in order to achieve high spatial resolution. The ion source for API is designed to produce a focused ion beam with a beam spot diameter of 1-mm or less on the target. We use an axial type neutron generator with a predicted neutron yield of 108 n/s for a 50 muA D/T ion beam current accelerated to 80 kV. The generator utilizes a RF planar spiral antenna at 13.56 MHz to create a highly efficient inductively-coupled plasma at the ion source. Experimental results show that beams with an atomic ion fraction of over 80percent can be obtained while utilizing only 100 watts of RF power in the ion source. A single acceleration gap with a secondary electron suppression electrode is used in the tube. Experimental results, such as the current density, atomic ion fraction, electron temperature, and electron density, from ion source testing will be discussed.

43 PARTICLE ACCELERATORS↗

Magnetic x-ray microscopy at low temperatures – Visualization of flux distributions in superconductors

X-ray Magnetic Circular Dichroism (XMCD) microscopy at liquid nitrogen temperature has been performed on bilayers of high-T{sub c} superconducting YBCO (YBa{sub 2}Cu{sub 3}O{sub 7-δ}) and soft-magnetic Co{sub 40}Fe{sub 40}B{sub 20}. This should allow us to map the magnetic flux density distribution in the current-carrying state of the superconductor with high spatial resolution. For that purpose the UHV scanning X-ray microscope MAXYMUS has been upgraded by a MMR Micro Miniature Joule-Thompson cryostat capable of temperatures between 75 K and 580 K. Resulting XMCD images of the magnetic flux density in the superconductor with a field of view ranging from millimeters to micrometers are presented. The microscope’s unique combination of total electron yield (TEY) measurements together with low temperatures offers novel possibilities concerning the current transport in superconductors on small length scales.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hybrid chemical characterization of latent images in EUV resist with 12 nm half-pitch features

With the advancement of high numerical aperture extreme ultraviolet (EUV) lithography, the new platform will enable chipmakers to achieve critical dimensions of 8 nm. However, resist materials face significant challenges in delivering increased sensitivity while managing rising stochastic variations. We aim to develop comprehensive techniques to characterize the chemical profile of latent images, stored in EUV resists after exposure and postexposure baking, which is essential for understanding the origin of stochastic effects. Infrared photo-induced force microscopy (IR PiFM) is a bimodal atomic force microscopy technique combined with an infrared light source, allowing for simultaneous sub-5 nm topographic and chemical characterization within a localized environment. Critical-dimension resonant soft X-ray scatterometry (CD-RSoXS) provides statistical data that reveal structural and chemical information for comparative analysis. For the first time, IR PiFM has been used to chemically map the latent images of EUV resists (after exposure and postexposure baking) at a record high resolution of 12 nm half-pitch, enabling nondestructive analysis of patterns prior to development. Furthermore, CD-RSoXS offers direct experimental observation and comparison of exposed, postexposure baked, and developed patterns, which align with the IR PiFM results. We demonstrate that the IR PiFM technique offers valuable insights into both high spatial resolution and local chemical information simultaneously. In addition, CD-RSoXS provides statistical results that support our main findings. This hybrid metrology approach leverages a multifaceted dataset by combining the most reliable information from each source, which is essential for a comprehensive understanding of the stochastic effects in EUV lithography processes.

O’Reilly, Padraic↗

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thinking Outside of the Blue Marble: Novel Ocean Applications Using the VIIRS Sensor

While planning for future space-borne sensors will increase the quality, quantity, and duration of ocean observations in the years to come, efforts to extend the limits of sensors currently in orbit can help shed light on future scientific gains as well as associated uncertainties. Here, we present several applications that are unique to the polar orbiting Visual Infrared Imaging Radiometer Suite (VIIRS), each of which challenge the threshold capabilities of the sensor and provide lessons for future missions. For instance, while moderate resolution polar orbiters typically have a one day revisit time, we are able to obtain multiple looks of the same area by focusing on the extreme zenith angles where orbital views overlap, and pair these observations with those from other sensors to create pseudo-geostationary data sets. Or, by exploiting high spatial resolution (imaging) channels and analyzing patterns of synoptic covariance across the visible spectrum, we can obtain higher spatial resolution bio-optical products. Alternatively, non-traditional products can illuminate important biological interactions in the ocean, such as the use of the Day-Night-Band to provide some quantification of phototactic behavior of marine life along light polluted beaches, as well as track the location of marine fishing vessel fleets along ocean fronts. In this talk, we explore ways to take full advantage of the capabilities of existing sensors in order to maximize insights for future missions.

ocean color↗

SURFACE WAVES IN SOLAR GRANULATION OBSERVED WITH SUNRISE

Solar oscillations are expected to be excited by turbulent flows in the intergranular lanes near the solar surface. Time series recorded by the IMaX instrument on board the SUNRISE observatory reveal solar oscillations at high spatial resolution, which allow the study of the properties of oscillations with short wavelengths. We analyze two time series with synchronous recordings of Doppler velocity and continuum intensity images with durations of 32 minutes and 23 minutes, respectively, recorded close to the disk center of the Sun to study the propagation and excitation of solar acoustic oscillations. In the Doppler velocity data, both the standing acoustic waves and the short-lived, high-degree running waves are visible. The standing waves are visible as temporary enhancements of the amplitudes of the large-scale velocity field due to the stochastic superposition of the acoustic waves. We focus on the high-degree small-scale waves by suitable filtering in the Fourier domain. Investigating the propagation and excitation of f- and p {sub 1}-modes with wavenumbers k>1.4 Mm{sup -1}, we also find that exploding granules contribute to the excitation of solar p-modes in addition to the contribution of intergranular lanes.

79 ASTRONOMY AND ASTROPHYSICS↗

Radial scanning diagnostics of bremsstrahlung and line emission in T-10 plasma

The paper describes the scanning spectroscopic diagnostics designed for measurement of line integrated plasma radiation in two visible spectral ranges. This diagnostic system is aimed at measuring the bremsstrahlung absolute values and profile with high spatial resolution. The bremsstrahlung absolute values are used to determine the value and radial distribution of effective plasma ion charge Z{sub eff}(r) in T-10 discharges. The importance of Z{sub eff} measurement is due to its strong influence on plasma heating, confinement, and stability. The spatial distribution of emission for one of the chosen spectral lines is measured simultaneously with bremsstrahlung. The spatial resolution of measurements is ~1 cm, and the temporal resolution is up to 10 ms. The spectral equipment and methods for its calibration are described. Examples of line integrated brightness distribution in a “continuum window” of 5236 ± 6 Å and brightness of the lines C{sup 5+} (5291 Å), He{sup 1+} (4686 Å), and D{sub β} (4861 Å) are given. Flattening of the bremsstrahlung brightness profile in the central region of the plasma column in some discharges with sawtooth oscillations in the T-10 is observed. The measured effective ion charge profiles in ohmic discharges with high plasma density and low discharge currents demonstrate accumulation of light impurities at the column axis; as a consequence, quenching of sawtooth oscillations in some discharges is observed. The developed diagnostics provides necessary data for investigation of heat, particle, and current transport in the plasma of the T-10. Successful application of the obtained data on Z{sub eff}(r) for investigation of geodesic acoustic modes of plasma oscillations in the T-10 should be specially noted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct nanoscale mapping of open circuit voltages at local back surface fields for PERC solar cells

The open circuit voltage (V OC) is a critical and common indicator of solar cell performance as well as degradation, for panel down to lab-scale photovoltaics. Detecting V OC at the nanoscale is much more challenging, however, due to experimental limitations on spatial resolution, voltage resolution, and/or measurement times. Accordingly, in this work an approach based on Conductive Atomic Force Microscopy is implemented to directly detect the local V OC , notably for monocrystalline Passivated Emitter Rear Contact (PERC) cells which are the most common industrial-scale solar panel technology in production worldwide. This is demonstrated with cross-sectioned monocrystalline PERC cells around the entire circumference of a poly-Aluminum-Silicide via through the rear emitter. The V OC maps reveal a local Back Surface Field extending ~2 μm into the underlying p-type Si absorber due to Al in-diffusion as designed. Such high spatial resolution methods for photovoltaic performance mapping are especially promising for directly visualizing the effects of processing parameters, as well as identifying signatures of degradation for silicon and other solar cell technologies.

14 SOLAR ENERGY↗

Characteristics of a RF-Driven Ion Source for a Neutron Generator Used for Associated Particle Imaging

We present recent work on a prototype compact neutron generator for associated particle imaging (API). API uses alpha particles that are produced simultaneously with neutrons in the deuterium-tritium ({sup 2}D({sup 3}T,n){sup 4}{alpha}) fusion reaction to determine the direction of the neutrons upon exiting the reaction. This method determines the spatial position of each neutron interaction and requires the neutrons to be generated from a small spot in order to achieve high spatial resolution. The ion source for API is designed to produce a focused ion beam with a beam spot diameter of 1-mm or less on the target. We use an axial type neutron generator with a predicted neutron yield of 10{sup 8} n/s for a 50 {mu}A D/T ion beam current accelerated to 80 kV. The generator utilizes an RF planar spiral antenna at 13.56 MHz to create a highly efficient inductively coupled plasma at the ion source. Experimental results show that beams with an atomic ion fraction of over 80% can be obtained while utilizing only 100 watts of RF power in the ion source. A single acceleration gap with a secondary electron suppression electrode is used in the tube. Experimental results from ion source testing, such as the current density, atomic ion fraction, electron temperature, and electron density will be discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Spatially Resolved Mapping of Three-Dimensional Molecular Orientations with ~2 nm Spatial Resolution through Tip-Enhanced Raman Scattering

We record local optical field images of silver nanocubes (75 nm) using tip-enhanced Raman (TER) spectral imaging. The images that we observe are consistent with several recent reports from our group, but here, we demonstrate sub-2 nm spatial resolution in local optical field nanoimaging under ambient laboratory conditions. This is achieved by scanning the substrate (nanocube on Si) relative to a 4-thiobenzonitrile (TBN)-functionalized Ag-coated TER probe. The spatial resolution that we obtain necessitates that only a few molecules govern the recorded optical response; molecular orientation becomes an important consideration in such measurements. We model the orientation through geometry optimization of a TBN molecule chemisorbed onto an Ag79 cluster (sphere with a ~1 nm diameter). Using the computed orientation of the cluster-bound molecule, we then model the optical response using formalism that accounts for the orientation of the molecule relative to vector components of the local optical fields. We find optimal agreement between experiment and theory. In effect, this work reveals the parallels between single-molecule Raman scattering and high-spatial-resolution TER spectroscopy, even when the images themselves cannot be used to visualize a single molecule in real space.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scattering-type scanning near-field optical microscopy with Akiyama piezo-probes

Recent developments of the scattering-type scanning near-field optical microscope at cryogenic temperatures (cryogenic s-SNOM or cryo-SNOM) have led to many breakthroughs in the studies of low energy excitations in quantum materials. However, the simultaneous demands on vibration isolation, low base temperature, precise nano-positioning, and optical access make the construction of a cryo-SNOM a daunting task. Adding to the overhead space required for a cryo-SNOM is the atomic force microscopy control, which predominantly utilizes a laser-based detection scheme for determining the cantilever tapping motion. In this work, we provide an alternative and straightforward route to performing s-SNOM using metal-coated Akiyama probes, where the cantilever tapping motion is detected through a piezoelectric signal. We show that the Akiyama-based cryo-SNOM attains high spatial resolution, good near-field contrast, and is able to perform imaging with a significantly more compact system compared to other cryo-SNOM implementations. Our results firmly establish the potential of s-SNOM based on self-sensing piezo-probes, which can easily accommodate far-infrared wavelengths and high magnetic fields in the future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using eclogite retrogression to track the rapid exhumation of the Pliocene Papua New Guinea UHP Terrane

The D’Entrecasteaux Islands of eastern Papua New Guinea (PNG) host the youngest known ultrahigh-pressure terrane on Earth and represent the only location where ultrahigh-pressure (UHP) rocks have been exhumed in an active rift. The PNG (U)HP rocks, consisting of Pliocene eclogites, garnet amphibolites and migmatitic gneisses, are exposed in five domal structures across the Islands. Zirconium-in-rutile thermometry records peak temperatures of ~780°C from the eastern Oiatabu and nearby central Mailolo Domes, and hotter temperatures of ~825–865°C within the western Goodenough Dome. Uranium–lead (U–Pb) and trace element zircon compositions from a suite of eclogite, host gneiss, felsic dikes and pegmatite from three domes document the rapid exhumation history of the PNG UHP terrane. High-spatial resolution laser-ablation split-stream inductively coupled plasma-mass spectrometry (LASS ICP-MS) analyses of select eclogite zircons exhibit no resolvable age zoning within single crystals. The same eclogite zircons, combined with separate zircons extracted from additional eclogite, host gneiss and felsic intrusions, were subsequently analysed by high-precision U–Pb chemical-abrasion isotope-dilution thermal ionization mass spectrometry and solution ICP-MS trace element analysis (TIMS-TEA). The results record discrete tectonic events across the three domes at sub-million year timescales: (1) (re)crystallization of host gneiss within the lower crust exposed in the eastern Oiatabu Dome from c.5·7–4·5 Ma; (2) initial retrogression and local decompression melting of eclogites from the Oiatabu and Mailolo Domes at c.4·6–4·3 Ma; (3) melt crystallization of weakly deformed felsic dikes of the Oiatabu Dome at c.3·0–2·9 Ma; and (4) retrogression and melt crystallization within eclogite–amphibolite-facies rocks in the western Goodenough Dome at c.2·9–2·6 Ma. In comparison to Zr-in-rutile peak temperature estimates, Ti-in-zircon temperatures >800°C may reflect increased temperatures during exhumation that resulted in partial melting of the eclogites. Inclusions of crystallized hydrous melt consisting of Na-rich plagioclase ± K-feldspar + quartz within eclogite zircons document this process. The elevated temperatures and the presence of the polyphase inclusions are the first documentation of partial melting of the (U)HP eclogites within PNG during initial retrogression from c.4·6–4·3 Ma. Finally, overall, U–Pb zircon geochronology and geochemistry track both the timing of retrogressive overprinting within the lower-to-middle crust and final upper crustal emplacement over a relatively short span of ~2 Myr during the rapid (≥2·3 cm/yr) exhumation of the youngest known (U)HP eclogites.

58 GEOSCIENCES↗