Integrated Modeling of ECR Charge Breeder Ion Sources
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
A numerical model, based on the fluid plasma theory, has been used for description of the spatial distribution of the plasma parameters (electron density and temperature, plasma potential as well as densities of the three types of positive hydrogen ions) in the IPP prototype RF negative hydrogen ion source. The model covers the driver and the expansion plasma region of the source with their actual size and accounts for the presence of the magnetic filter field with its actual value and location as well as for the bias potential applied to the plasma grid. The obtained results show that without a magnetic filter the two 2D geometries considered, respectively, with an axial symmetry and a planar one, represent accurately the complex 3D structure of the source. The 2D model with a planar symmetry (where the E×B and diamagnetic drifts could be involved in the description) has been used for analysis of the influence, via the charged-particle and electron-energy fluxes, of the magnetic filter and of the bias potential on the spatial structure of the plasma parameters in the source. Benchmarking of results from the code to experimental data shows that the model reproduces the general trend in the axial behavior of the plasma parameters in the source.
The ORNL team will provide LANL with a scoping / feasibility study of H - sources which could potentially be developed to approach the goal of producing a single high-duty-factor H - beam of up to ~100 mA suitable for acceleration by an RFQ. Currently, no existing H - sources have been shown to operate anywhere near this goal so the study will focus on identifying the most promising approach and define the existing option space. Attention will be given to source concepts which are most likely to be scalable to continuous beam operation while offering lower-risk, lower duty-factor or beam current operation in the shorter term. The study will discuss the technology within this option space, tradeoffs and identify the best path forward. Once the best option is identified, an estimate of the expected output emittance, beam current, achievable beam duty-factor, hydrogen and cesium consumption rates, physical size and weight estimates of the source and supporting subsystems will be provided. This work will lay the foundation for developing a conceptual source design in Development 2 which will inform an actual mechanical design that will be used to either construct a prototype source or modify an existing source as part of a future technology development program for the project. The relative technology development risk and mitigations would also be defined for the candidate ion source technologies for a TRL 5 demonstration. Risk analysis for later TRL 6 phases and beyond would be part of a later phase of the project.
We are developing an ECRIS apparatus which is designed for the production of endohedral fullerenes. Our promising approaches to produce the endohedral fullerenes using the ECRIS are the ion-ion collision reaction of fullerenes and the other atom in their mixture plasma and simple ion implantation of atom into fullerene layer. In this study, we tried to synthesize the endohedral nitrogen-fullerenes by ion implantation. N{sup +} beam was irradiated to a fullerene target with a specific energy and dose. As a result, we could observe the peak of N+C{sub 60} from targets after N{sup +} beam irradiation with TOF-SIMS and LDI-TOF-MS.
The article summarizes the discussions held during the PIBHI 2025 workshop (https://agenda.infn.it/e/pibhi2025) highlighting the most significant points to have emerged. The main goal of the workshop was to foster dialogue on topics relevant to the ECR ion sources (ECRIS) community through dedicated and thematic round tables. The outcomes of these discussions are outlined below, with particular focus on the remaining open questions in the field.
Simple algebraic equations are developed that can be used to calculate the average primary electron density, the average primary to Maxwellian density ratio, and the average Maxwellian electron temperature in the discharge chamber of a cusped magnetic field ion source. These properties may be calculated as functions of the propellant gas flow rate and the propellant utilization efficiency. Each of the plasma properties calculated using the model agrees well with the corresponding experimental data for both argon and xenon gases over a wide range of propellant flow rates and utilization efficiencies.
Negative hydrogen (H{sup −}) ion yield from the plasma grid due to incident hydrogen ions and neutrals has been evaluated with the surface collision cascade model, ACAT (Atomic Collision in Amorphous Target) coupled to a negative surface ionization models. Dependence of negative ion fractions upon the velocity component normal to the surface largely affect the calculation results of the final energy and angular distributions of the H{sup −} ions. The influence is particularly large for H{sup −} ions desorbed from the surface due to less than several eV hydrogen particle implact. The present calculation predicts that H{sup −} ion yield can be maximized by setting the incident angle of hydrogen ions and neutrals to be 65 degree. The Cs thickness on the plasma grid should also affect the yields and mean energies of surface produced H{sup −} ions by back scattering and ion induced desorption processes.
Flight model cesium ion beam source for electric field strength measuring instrument
© 2002-2011 IEEE. The superconducting ECR source magnet for the Facility for Rare Isotope Beams at Michigan State University was designed and built by the Superconducting Magnet Group at Lawrence Berkeley National Laboratory (LBNL). The 28-GHz NbTi ion source magnet features a sextupole-in-solenoids configuration, which is comparable to the VENUS ECR magnet operated at LBNL. A shell-based support structure using bladders and keys has been incorporated into the design to allow for adjustments of the preload and reversibility of the magnet assembly process. The magnet has been assembled and successfully tested to operational currents at LBNL. This paper describes the basic design of the magnet and the passive quench protection system. The test results are also presented, including the quench behavior of the magnet, the training performance, and the magnetic measurement results.
The superconducting electron cyclotron resonance (ECR) source magnet for the facility for rare isotope beams at Michigan State University was designed and built by the Superconducting Magnet Group at Lawrence Berkeley National Laboratory (LBNL) in 2017. The 28 GHz NbTi ion source magnet features a sextupole-in-solenoids configuration which is comparable to the VENUS ECR magnet operated at LBNL. However, the mechanical design of this magnet utilizes a shell-based support structure which allows fine adjustments to the sextupole preload and reversibility of the magnet assembly process. The magnet has been assembled and tested to operational currents at LBNL. This paper describes the mechanical analyses performed to estimate the sextupole's and solenoids' preloads. We will report on the 3-D finite element analysis during room temperature assembly, cool-down, and magnet excitation, and then describe the magnet preload operations. To conclude, we will describe the performance of the support structure during the quench training.
Negative ion generation on HOPG graphite surface has been studied in hydrogen and deuterium plasma. We measure Ion Distribution Function (IDF) of negative ions coming from graphite surface bombarded by positive ions in H{sub 2}/D{sub 2} plasmas. We showed that negative ions flux was proportional to positive ion flux and was strongly dependant on impinging energy. IDF study shows two generation mechanisms are involved: sputtering of adsorbed H/D as negative ions and, in a less important way, double electron capture. We compare H{sub 2}/D{sub 2} plasmas, and point out isotopic effect between H{sup -} and D{sup -} production.
The detection of volatile vapors of unknown species in a complex field environment is required in many different applications. Mass spectroscopic techniques require subsystems including an ionization unit and sample transport mechanism. All of these subsystems must have low mass, small volume, low power, and be rugged. A volatile molecular detector, an ambient pressure pyroelectric ion source (APPIS) that met these requirements, was recently reported by Caltech researchers to be used in in situ environments.
The primary challenge in directly measuring nuclear reaction rates near stellar energies is their small cross sections. The signal-to-background ratio in these complex experiments can be significantly improved by employing high-current (mA-range) beams and novel detection techniques. Therefore, the electron cyclotron resonance ion source at the Laboratory for Experimental Nuclear Astrophysics underwent a complete upgrade of its acceleration column and microwave system to obtain high-intensity, pulsed proton beams. The new column uses a compression design with O-ring seals for vacuum integrity. Its voltage gradient between electrode sections is produced by the parallel resistance of channels of chilled, deionized water. It also incorporates alternating, transverse magnetic fields for electron suppression and an axially adjustable beam extraction system. Following this upgrade, the operational bremsstrahlung radiation levels and high-voltage stability of the source were vastly improved, over 3.5 mA of target beam current was achieved, and an order-of-magnitude increase in normalized brightness was measured. Beam optics calculations, structural design, and further performance results for this source are presented.
An electron emission control circuit of the switching regulator type operating at 100 kHz has been developed which maintains a constant emission current within 0.1% for a cathode power demand variation of approximately 100%. The power output stage has an efficiency of 67%, and the overall efficiency is 45% when driving a thoria-coated iridium cathode having a nominal resistance at operating temperature of 2.5 ohms. Under optimum conditions, the bus power demand is 1.75 W. The circuit is useful in controlling the electron emission current of ion sources in applications which involve a substantial variation of the cathode work function, such as oxygen partial pressure measurements over a large dynamic range.
Extraction of negative ions from a saddle antenna radio-frequency surface plasma source is considered. Several versions of new plasma generators with different antennas and magnetic field configurations were tested in the smal Oak Ridge National Laboratory Spallation Neutron Source Test Stand. The efficiency of positive ion generation in plasma has been improved to 200 mA/cm{sup 2} kW from 2.5 mA/cm{sup 2} kW. A small oven was developed for cesiation by cesium compounds and alloy decomposition. After cesiation, a current of negative ions to the collector was increased from 1 mA to 10 mA with 1.5 kW RF power in the plasma and longitudinal magnetic field B{sub l} ∼ 250 G. The specific efficiency of H{sup −} production was increased to 20 mA/cm{sup 2} kW from 2.5 mA/cm{sup 2} kW.
The volatile element Cl can be lost during the formation and evolution of planetary bodies, leading to fractionation of its two stable isotopes 35Cl and 37Cl. Chlorine isotope variations (reported as δ37Cl in parts per thousand (‰) relative to Standard Mean Ocean Chloride, SMOC) [1] are documented to exceed 80‰ [2] between different lunar rock samples and have been variably interpreted as the fingerprint of degassing during accretion, magma ocean, or volcanic portions of lunar history[3,4].The large intersample and intrasample variations observed by both bulk isotope ratio mass spectrometry (IRMS) and in-situ secondary ion mass spectrometry (SIMS) methods are difficult to interpret in part because of a paucity of bulk Cl isotope measurements (Figure 1).This lack of high-precision bulk data is due to the relative rarity of IRMS laboratories capable of making these high precision measurements on small samples of precious planetary materials such as those returned by human or robotic exploration. Here we present a new method for performing high precision δ37Cl measurements using the Cs-sputter negative ion source of an existing accelerator mass spectrometer. A brief description of the methods used for this work is followed by the results of our δ37Cl measurements and a discussion of the technique’s possible applications.
Gas stoppers have been used for a long-standing successful science program at Michigan State University with stopped and rare-isotope beams produced by projectile fragmentation. The National Superconducting Cyclotron Laboratory’s Coupled Cyclotron Facility has recently transitioned into the Facility for Rare Isotope Beams (FRIB) laboratory to provide rare isotopes using a high-power superconducting linear accelerator and new production facilities. To allow the science program with stopped and reaccelerated beams to continue during the transition period, a stand-alone capability was added. The Batch Mode Ion Source (BMIS) was built and has been providing beams of long-lived and stable isotopes of a variety of elements for successful user experiments. Finally, the BMIS system is described and results from the production of various beams are presented.
An increasing number of experiments in the field of low energy ion physics (<25 keV/charge) requires pulsed beams of highly charged ions. Whereas for high-intensity beams (greater than microampere) a pulsed beam chopper, installed downstream to the analyzing dipole, is used. For low-intensity beams (<100 nA) the ion intensity delivered during the pulse may be increased by operating the electron cyclotron resonance discharge in the afterglow mode. This method gives satisfactory results (i.e., average current during the beam pulse is higher than the current in the cw mode) for high charge state ions. In this paper, we report on results of the afterglow mode for beams of {sup 22}Ne{sup q+}, {sup 36}Ar{sup q+}, and {sup 84}Kr{sup q+} ions. Furthermore, a new promising ''micropulsed beam'' mode will be described with encouraging preliminary results for {sup 84}Kr{sup 27+} and {sup 36}Ar{sup 17+} ions.