Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Technical solutions to reduce mediastinal irradiation in young patients undergoing treatment for lymphomas: Preliminary experience

This study aims at optimizing treatment planning in young patients affected by lymphoma (Stage II to III) by using an inclined board (IB) that allows reducing doses to the organs at risk. We evaluated 19 young patients affected by stage I to III lymphomas, referred to our Department for consolidation radiotherapy (RT) treatment on the mediastinum. Patients underwent 2 planning computed tomography (CT) scans performed in different positions: flat standard position and inclined position. A direct comparison between the different treatment plans was carried out analyzing dosimetric parameters obtained from dose-volume histograms generated for each plan. Comparison was performed to evaluate the sparing obtained on breast and heart. Dosimetric evaluation was performed for the following organs at risk (OARs): mammary glands, lungs, and heart. A statistically significant advantage was reported for V{sub 5}, V{sub 20}, and V{sub 30} for the breast when using the inclined board. A similar result was obtained for V{sub 5} and V{sub 10} on the heart. No advantage was observed in lung doses. The use of a simple device, such as an inclined board, allows the optimization of treatment plan, especially in young female patients, by ensuring a significant reduction of the dose delivered to breast and heart.

61 RADIATION PROTECTION AND DOSIMETRY↗

An impedance-based diameter gauge for in-pile fuel deformation measurements

During irradiation, the fuel-cladding interface of a nuclear fuel rod can experience significant mechanical and chemical interaction. In-situ measurement of the radial deformation of the cladding can quantify the extent of this interaction and the state of the cladding. Existing capabilities to perform in-pile diameter measurements are limited by required contact and an intrusive presence of a device near to a specimen. To overcome these limitations, researchers have developed and evaluated an electrical impedance based diameter gauge using a benchtop system. The sensor consists of an electrically conductive concentric ring around the fuel cladding such that the electrical impedance between the ring and cladding is measured. Additionally, the cladding diameter is determined through a measurement of the electrical impedance between the electrodes with a known ring electrode diameter. Analytic and 3-D finite element analyses (FEA) were used to quantify the measurement sensitivity, uncertainty, and off-design conditions. The experimental sensor measured diameters with <20 µm of error, and had a measurement resolution of <1 µm for diameters ranging from 9.5 to 9.6 mm. Lastly, the uncertainty analysis for the experimental setup estimated an uncertainty of 20 µm, consistent with the experimentally measured results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient Solar‐Thermal Distillation Desalination Device by Light Absorptive Carbon Composite Porous Foam

Abstract Solar‐thermal driven desalination based on porous carbon materials has promise for fresh water production. Exploration of high‐efficiency solar desalination devices has not solved issues for practical application, namely complicated fabrication, cost‐effectiveness, and scalability. Here, direct solar‐thermal carbon distillation (DS‐CD) tubular devices are introduced that have a facile fabrication process, are scalable, and use an inexpensive but efficient microporous graphite foam coated with carbon nanoparticle and superhydrophobic materials. The “black” composite foam serving as a solar light absorber heats up salt water effectively to produce fresh water vapor, and the superhydrophobic surface of the foam traps the liquid feed in the device. Two proof‐of‐principle distillation systems are adopted, i.e., solar still and membrane distillation and the fabricated devices are evaluated for direct solar desalination efficiency. For the solar still, nanoparticle and fluorosilane coatings on the porous surface increase the solar energy absorbance, resulting in a solar‐steam generation efficiency of 64% from simulated seawater at 1 sun. The membrane distillation demonstrates excellent vapor production (≈6.6 kg m ‐2 h ‐1 ) with >99.5% salt rejection under simulated 3 sun solar‐thermal irradiation. Unlike traditional solar desalination, the adaptable DS‐CD can easily be scaled up to larger systems such as high‐temperature tubular modules, presenting a promising solution for solar‐energy‐driven desalination.

42 ENGINEERING↗

Pulsed laser deposition of high-quality thin films of the insulating ferromagnet EuS

High-quality thin films of the ferromagnetic insulator europium(II) sulfide (EuS) were fabricated by pulsed laser deposition on Al{sub 2}O{sub 3} (0001) and Si (100) substrates. A single orientation was obtained with the [100] planes parallel to the substrates, with atomic-scale smoothness indicates a near-ideal surface topography. The films exhibit uniform ferromagnetism below 15.9 K, with a substantial component of the magnetization perpendicular to the plane of the films. Optimization of the growth condition also yielded truly insulating films with immeasurably large resistance. This combination of magnetic and electric properties opens the gate for future devices that require a true ferromagnetic insulator.

36 MATERIALS SCIENCE↗

Electric field dependence of junction magnetoresistance in magnetite/semiconductor heterostructure at room temperature

We have fabricated Fe{sub 3}O{sub 4}/p-Si heterojunction using pulsed laser deposition technique and explored its electro-magnetic transport properties. The heterojunction exhibits backward rectifying property at all temperatures, and appraisal of giant junction magnetoresistance (JMR) is observed at room temperature (RT). Conspicuously, the variation and sign change of JMR as a function of electric field is observed at RT. The backward rectifying behavior of the device is ascribed to the highly doped p-type (p{sup ++}) semiconducting nature of Fe{sub 3}O{sub 4}, and the origin of electric field (voltage) dependence of magnetoresistance is explained proposing electronic band diagram of Fe{sub 3}O{sub 4}/SiO{sub 2}/p-Si heterojunction. This interesting result may have importance to integrate Si-based magnetoresistance sources in multifunctional spintronic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-D-BRA-03: Four-Dimensional Dose Reconstruction Through Retrospective Phase Determination Using Cine Images of Electronic Portal Imaging Device

Purpose: To test a method to reconstruct a four-dimensional (4D) dose distribution using the correlation of pre-calculated 4D electronic portal imaging device (EPID) images and measured cine-EPID images. Methods: 1. A phantom designed to simulate a tumor in lung (a polystyrene block with 3.0 cm diameter embedded in cork) was placed on a sinusoidally moving platform with 2 cm amplitude and 4 sec/cycle. Ten-phase 4D CT images were acquired for treatment planning and dose reconstruction. A 6MV photon beam was irradiated on the phantom with static (field size=5×8.5 cm{sup 2}) and dynamic fields (sliding windows, 10×10 cm{sup 2}, X1 MLC closing in parallel with the tumor movement). 2. 4D and 3D doses were calculated forwardly on PTV (1 cm margin). 3. Dose images on EPID under the fields were calculated for 10 phases. 4. Cine EPID images were acquired during irradiation. 5. Their acquisition times were correlated to the phases of the phantom at which irradiation occurred by inter-comparing calculated “reference” EPID images with measured images (2D gamma comparison). For the dynamic beam, the tumor was hidden under MLCs during a portion of irradiation time; the correlation performed when the tumor was visible was extrapolated. 6. Dose for each phase was reconstructed on the 4D CT images and summed over all phases. The summation was compared with forwardly calculated 4D and 3D dose distributions. Monte Carlo methods were used for all calculations. Results: For the open and dynamic beams, the 4D reconstructed doses showed the pass rates of 92.7 % and 100 %, respectively, at the isocenter plane given 3% / 3 mm criteria. The better agreement of the dynamic beam was from its dose gradient which blurred the otherwise sharp difference between forward and reconstructed doses. This also contributed slightly better agreement in DVH of PTV. Conclusion: The feasibility of 4D reconstruction was demonstrated.

60 APPLIED LIFE SCIENCES↗

Single event upset vulnerability of selected 4K and 16K CMOS static RAM's

Upset thresholds for bulk CMOS and CMOS/SOS RAMS were deduced after bombardment of the devices with 140 MeV Kr, 160 MeV Ar, and 33 MeV O beams in a cyclotron. The trials were performed to test prototype devices intended for space applications, to relate feature size to the critical upset charge, and to check the validity of computer simulation models. The tests were run on 4 and 1 K memory cells with 6 transistors, in either hardened or unhardened configurations. The upset cross sections were calculated to determine the critical charge for upset from the soft errors observed in the irradiated cells. Computer simulations of the critical charge were found to deviate from the experimentally observed variation of the critical charge as the square of the feature size. Modeled values of series resistors decoupling the inverter pairs of memory cells showed that above some minimum resistance value a small increase in resistance produces a large increase in the critical charge, which the experimental data showed to be of questionable validity unless the value is made dependent on the maximum allowed read-write time.

Kolasinski, W. A.↗

SU-C-BRE-04: Microbeam-Radiation-Therapy (MRT): Characterizing a Novel MRT Device Using High Resolution 3D Dosimetry

Purpose: The feasibility of MRT has recently been demonstrated utilizing a new technology of Carbon-Nano-Tube(CNT) field emission x-ray sources.This approach can deliver very high dose(10's of Gy) in narrow stripes(sub-mm) of radiation which enables the study of novel radiation treatment approaches. Here we investigate the application of highresolution (50um isotropic) PRESAGE/Optical-CT 3D dosimetry techniques to characterize the radiation delivered in this extremely dosimetrically challenging scenario. Methods: The CNT field emission x-ray source irradiator comprises of a linear cathode array and a novel collimator alignment system. This allows a precise delivery of high-energy small beams up to 160 kVp. A cylindrical dosimeter (∼2.2cm in height ∼2.5cm in diameter) was irradiated by CNT MRT delivering 3 strips of radiation with a nominal entrance dose of 32 Gy.A second dosimeter was irradiated with similar entrance dose, with a regular x-ray irradiator collimated to microscopical strip-beams. 50um (isotropic) 3D dosimetry was performed using an in-house optical-CT system designed and optimized for high resolution imaging (including a stray light deconvolution correction).The percentage depth dose (PDD), peak-to-valley ratio (PVR) and beam width (FWHM) data were obtained and analyzed in both cases. Results: High resolution 3D images were successfully achieved with the prototype system, enabling extraction of PDD and dose profiles. The PDDs for the CNT irradiation showed pronounced attenuation, but less build-up effect than that from the multibeam irradiation. The beam spacing between the three strips has an average value of 0.9mm while that for the 13 strips is 1.5 mm at a depth of 16.5 mm. The stray light corrected image shows line profiles with reduced noise and consistent PVR values. Conclusion: MRT dosimetry is extremely challenging due to the ultra small fields involved.This preliminary application of a novel, ultra-high resolution, optical-CT 3D dosimetry system shows promise, but further work is required to validate and investigate accuracy and artifacts. This work was supported by NIH R01CA100835.

07 ISOTOPE AND RADIATION SOURCES↗

Note: A fast pneumatic sample-shuttle with attenuated shocks

We describe a home-built pneumatic shuttle suitable for the fast displacement of samples in the vicinity of a highly sensitive atomic magnetometer. The samples are magnetized at 1 T using a Halbach assembly of magnets. The device enables the remote detection of free-induction-decay in ultra-low-field and zero-field nuclear magnetic resonance (NMR) experiments, in relaxometric measurements and in other applications involving the displacement of magnetized samples within time intervals as short as a few tens of milliseconds. Other possible applications of fast sample shuttling exist in radiological studies, where samples have to be irradiated and then analyzed in a cold environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multijunction InGaAs thermophotovoltaic power converter

The experimental performance of a multijunction monolithic lattice-matched 0.74 eV InGaAs thermophotovoltaic (TPV) power converter under 980 C blackbody irradiation is reported. Eight InGaAs PN junctions grown epitaxially on a semi-insulating wafer were monolithically integrated in series to boost the approximately 0.4 V photovoltage per typical InGaAs junction to over 3 volts for the 1 cm(exp 2) chip. This chip was originally designed and characterized for free-space 1.3 micron laser power beaming. The power efficiency of this TPV device is 16% for that part of the blackbody spectrum above the material bandgap. The device is shown to deliver about 1 watt of output power when driven with enough light. This is the first report of such a multijunction TPV device. This is not a traditional tandem cell in which the junctions are stacked vertically. Eight 1 mm long by 1 cm wide junctions are laterally connected across the device area. This multijunction design has the potential for lower I(exp 2)R power loss since the smaller PN junction area limits the current to one eighth that of the equivalent surface area. In essence, the current is traded for voltage to avoid the I(exp 2)R loss, analogous to the way power utilities avoid I(exp 2)R loss in high-tension power lines, by transforming the high current, low voltage generated at a power plant into a high voltage at a low current before transmitting the power over great distances.

Wojtczuk, Steven↗

Displacement Damage Induced Dark Current and Random Telegraph Signal in P-Type Deep-Trench Pinned Photogates

This study focuses on displacement damage induced dark current and Random Telegraph Signal (RTS) in STMicroelectronics P-Type photogate, a device moving away from the 4T Pinned-Photodiode, with a sensitive volume exclusively made of boron-doped P-type epitaxy, and collecting holes instead of electrons. Results show a typical trend for the shape of dark current and RTS degradation in CMOS Image Sensors with the exception that the measured generation rates seem 2 times smaller than typical literature values in irradiated silicon. Different hypothesis on the origin of this discrepancy are explored.

displacement damage dose↗

SU-F-T-520: Dosimetric Comparison of Radiation Treatment Plans for Whole Breast Irradiation Between 3D Conformal in Prone and Supine Positions Vs. VMAT and IMRT in Supine Positions

Purpose: The target volume for Whole Breast Irradiation (WBI) is dictated by location of tumor mass, breast tissue distribution, and involvement of lymph nodes. Dose coverage and Organs at Risk (OARs) sparing can be difficult to achieve in patients with unfavorable thoracic geometries. For these cases, inverse-planned and 3D-conformal prone treatments can be alternatives to traditional supine 3D-conformal plans. A dosimetric comparison can determine which of these techniques achieve optimal target coverage while sparing OARs. Methods: This study included simulation datasets for 8 patients, 5 of whom were simulated in both supine and prone positions. Positioning devices included breast boards and Vaclok bags for the supine position, and prone breast boards for the prone position. WBI 3-D conformal plans were created for patients simulated in both positions. Additional VMAT and IMRT WBI plans were made for all patients in the supine position. Results: Prone and supine 3D conformal plans had comparable PTV coverage. Prone 3D conformal plans received a significant 50% decrease to V20, V10, V5 and V30% for the ipsilateral lung in contrast to the supine plans. The heart also experienced a 10% decrease in maximum dose in the prone position, and V20, V10, V5 and V2 had significantly lower values than the supine plan. Supine IMRT and VMAT breast plans obtained comparable PTV coverage. The heart experienced a 10% decrease in maximum dose with inverse modulated plans when compared to the supine 3D conformal plan, while V20, V10, V5 and V2 showed higher values with inverse modulated plans than with supine 3D conformal plans. Conclusion: Prone 3D-conformal, and supine inverse planned treatments were generally superior in sparing OARs to supine plans with comparable PTV coverage. IMRT and VMAT plans offer sparing of OARs from high dose regions with an increase of irradiated volume in the low dose regions.

60 APPLIED LIFE SCIENCES↗

Development of Technology for Detachment of Calandria Tube Rolled Joint of Pressurised Heavy Water Reactors

Coolant channel assembly of PHWRs consisting mainly of pressure tube and calandria tube undergoes sag due to irradiation enhanced creep during its life time. Typical service life of the pressure tube is limited to about 15 full power years due to such ageing related degradation. On account of the degradation the pressure tube needs replacement more than twice during the licensed period of reactor operation. As the sag in the calandria tube is also excessive, it has to be replaced to facilitate installation of new and straight pressure tube during retubing and to avoid interference of sagged calandria tube with horizontal reactivity devices. The calandria tube and the tube sheet are joined by sandwich type rolled joints. For detaching the joint an improved technique has been developed that helps to detach the joint without affecting the groove geometry and integrity of the tube sheet. The system works on the principle of fast thermal cycle of heating and cooling of the insert and calandria tube in the rolled joint region while applying axial load to the calandria tube. Though rolled joint detachment by induction heating technique has been in use in CANDU reactors for removal of pressure tubes and calandria tubes, the present design incorporates a liquid nitrogen for faster cooling and simultaneous application of load with a gripping module for detachment and removal of calandria tube and the insert from the tube sheet of end shield in shorter time. This paper describes the methodology of rolled joint detachment, challenges involved in the design, features of the detachment system, findings of experimental trials and observations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of He seeding on hydrogen isotope permeation in tungsten by H-D mixed plasma exposure

Hydrogen (H) and deuterium (D) permeation fluxes for tungsten (W) by H-D mixed plasma were studied to clarify the hydrogen isotope effect on permeation by a newly designed plasma driven permeation (PDP) device at Shizuoka University. A mixed H-D plasma was produced by introducing H and D gasses with various ratios. The atomic ratio and permeation flux in the plasma were measured during the experiments. It was found that the H:D atomic ratio in the plasma was almost proportional to the introduced H:D gas ratio. When single species of H or D was irradiated, the H permeation rate showed approximately 1.6 times as high as that of D. Under H-D mixed plasma irradiation, the highest HD permeation rate was observed when the atomic ratio of H:D in the plasma was 50:50. In addition, the effect of He seeding on H-D mixed plasma driven permeation behavior was also evaluated. The recycling of hydrogen isotopes on the upstream side was enhanced due to the formation of He bubbles near the surface, which would prevent the dissolution of hydrogen isotopes into bulk W and enhance the reflection process during plasma exposure. H and D permeation fluxes were clearly reduced by seeding He in H-D mixed plasma. At lower temperature (~723 K), the ratio of steady permeation fluxes of H and D was about 75 : 25, confirming the high permeation flux of H . These results have demonstrated a significant hydrogen isotope effect, even if He was seeded or not. As the temperature increased, H and D permeation fluxes approached unity at 923 K. Therefore,this indicates that the hydrogen isotope effect was determined by the combination of recycling / reflection at or beneath the surface, which will be controlled by the temperature during plasma exposure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correlation of Radiation Dosage With Mechanical Properties of Thin Films

The objective of this investigation was to examine the relationship between irradiation level (proton dose), microstructure, and stress levels in chemical vapor deposited diamond and polysilicon film using crosssectioned specimens. However, the emphasis was placed on the diamond specimen because diamond holds much promise for use in advanced technologies. The use of protons allows not only the study of the charged particle that may cause the most microstructural damage in Earth-orbit microelectromechanical systems (MEMS) devices, but also allows the study of relatively deeply buried damage inside the diamond material. Using protons allows these studies without having to resort to megaelectronvolt implant energies that may create extensive damage due to the high energy that is needed for the implantation process. Since 1 MEMS devices operating in space will not have an opportunity to reverse radiation damage via annealing, only nonannealed specimens were investigated. The following three high spatial resolution techniques were used to examine these relationships: (I) Scanning electron microscopy, (2) micro-Raman spectroscopy, and (3) micro x-ray diffraction.

Newton, R. L.↗

Texas Instruments' virtual phase charge-coupled device (CCD) imager operated in the frontside electron-bombarded mode

The present investigation is concerned with the suitability of the virtual phase CCD imager for frontside detection of electrons up to 25 keV. The investigation has the objective to determine if the imager can be used in the frontside mode with a photocathode to detect very low light levels in astronomical applications, the ultimate goal being individual photon detection. It is found that the standard virtual phase imager will function properly over an extended period at low levels of 20 kV electron irradiation consistent with photon counting applications. The imager can detect individual primary electrons with nearly 100 percent efficiency. However, further studies are needed to determine the mechanisms for the flat band shifts so that the imager design may be modified to eliminate or at least reduce them.

Everett, P.↗

Beyond Epitaxy: Ion Implantation as a Tool for Orbital Engineering

Manipulating electronic orbital states in quantum materials provides a powerful means of controlling their physical properties and technological functionality. Here, we demonstrate that orbital populations in strongly correlated oxide thin films can be continuously and reversibly tuned through postsynthesis He ion implantation. Using LaNiO 3 as a model system, we show that the orbital preference can be systematically adjusted from favoring in-plane d x 2 –y 2 occupation toward out-of-plane d z 2 states through precise control of ion fluence. Unlike conventional heteroepitaxial approaches that lock in orbital configurations during growth, this strain-doping technique enables continuous orbital tuning and the selective modification of specific film regions after device fabrication. We demonstrate the practical impact of this control by achieving a 7-fold enhancement in oxygen reduction reaction catalysis. This work establishes ion implantation as a powerful approach for orbital engineering that complements existing synthesis-based strategies while offering unique advantages for both basic research and device development.

Doping↗

Total-Ionizing-Dose Effects on Read Noise of MLC 3-D NAND Memories T

This paper analyzes the total ionizing dose (TID) effects on noise characteristics of commercial multi-level-cell (MLC) 3-D NAND memory technology during the read operation. Additionally, the chips were exposed to a Co-60 gamma-ray source for up to 100 krad(Si) of TID. We find that the number of noisy cells in the irradiated chip increases with TID. Bit-flip noise was more dominant for cells in an erased state during irradiation compared to programmed cells.

3-D NAND Flash↗