Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging System Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

The AstraLux multiplicity survey: Extension to late M-dwarfs

The distribution of multiplicity among low-mass stars is a key issue to understanding the formation of stars and brown dwarfs, and recent surveys have yielded large enough samples of nearby low-mass stars to study this issue statistically to good accuracy. Previously, we have presented a multiplicity study of ∼700 early/mid M-type stars observed with the AstraLux high-resolution Lucky Imaging cameras. Here, we extend the study of multiplicity in M-type stars through studying 286 nearby mid/late M-type stars, bridging the gap between our previous study and multiplicity studies of brown dwarfs. Most of the targets have been observed more than once, allowing us to assess common proper motion to confirm companionship. We detect 68 confirmed or probable companions in 66 systems, of which 41 were previously undiscovered. Detections are made down to the resolution limit of ∼100 mas of the instrument. The raw multiplicity in the AstraLux sensitivity range is 17.9%, leading to a total multiplicity fraction of 21%-27% depending on the mass ratio distribution, which is consistent with being flat down to mass ratios of ∼0.4, but cannot be stringently constrained below this value. The semi-major axis distribution is well represented by a log-normal function with μ{sub a} = 0.78 and σ{sub a} = 0.47, which is narrower and peaked at smaller separations than for a Sun-like sample. This is consistent with a steady decrease in average semi-major axis from the highest-mass binary stars to the brown dwarf binaries.

79 ASTRONOMY AND ASTROPHYSICS↗

A SPITZER STUDY OF PSEUDOBULGES IN S0 GALAXIES: SECULAR EVOLUTION OF DISKS

In this Letter, we present a systematic study of lenticular (S0) galaxies based on mid-infrared imaging data on 185 objects taken using the Spitzer Infrared Array Camera. We identify the S0s hosting pseudobulges based on the position of the bulge on the Kormendy diagram and the Sersic index of the bulge. We find that pseudobulges preferentially occur in the fainter luminosity class (defined as having total K-band absolute magnitude M{sub K} fainter than -22.66 in the AB system). We present relations between bulge and disk parameters obtained as a function of the bulge type. The disks in the pseudobulge hosting galaxies are found to have distinct trends on the r{sub e}-r{sub d} and {mu}{sub d}(0)-r{sub d} correlations compared to those in galaxies with classical bulges. We show that the disks of pseudobulge hosts possess on average a smaller scale length and have a fainter central surface brightness than their counterparts occurring in classical bulge hosting galaxies. The differences found for discs in pseudobulge and classical bulge hosting galaxies may be a consequence of the different processes creating the central mass concentrations.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast and bright scintillators for ultrafast materials dynamics using 4th generation synchrotron

We present recent advances in fast and bright scintillators for ultrafast X-ray phase contrast imaging of dynamic materials experiments at the upgraded Advanced Photon Source (APS-U), a fourth generation synchrotron. APS-U enables hard X-ray imaging at frame rates of at least 13 MHz (corresponding to 77 ns or shorter interframe intervals), creating a new need for scintillators with faster response and higher light output than lutetium yttrium oxyorthosilicate (LYSO). For indirect imaging and diffraction with ultrafast cameras, commercial lanthanum bromide (LaBr3) and cerium bromide (CeBr3) are promising candidates. These materials exhibit decay times approximately a factor of two shorter than LYSO (around 40 ns) and lutetium oxyorthosilicate (LSO), while maintaining comparable light yield per incident X-ray photon. However, their implementation at APS-U requires addressing several challenges, including material limitations due to hygroscopicity, efficient optical coupling to imaging systems, and high quantum efficiency for conversion of scintillation light, predominantly at wavelengths below 400 nm, into detectable electronic signals. We report results from material characterization, detector integration and packaging, and beamline experiments of materials with impact. In addition, emerging scintillator classes, including perovskites and high-entropy materials, are discussed as potential alternatives for next-generation ultrafast X-ray diagnostics.

Wang, Zhehui [Los Alamos] (ORCID:0000000178264063)↗

WILLMAN 1-A PROBABLE DWARF GALAXY WITH AN IRREGULAR KINEMATIC DISTRIBUTION

We investigate the kinematic properties and stellar population of the Galactic satellite Willman 1 (Wil 1) by combining Keck/DEIMOS spectroscopy with Kitt Peak National Observatory mosaic camera imaging. Wil 1, also known as SDSS J1049+5103, is a nearby, ultra-low luminosity Milky Way companion. This object lies in a region of size-luminosity space (M{sub V} {approx} -2 mag, d {approx} 38 kpc, r{sub half} {approx} 20 pc) also occupied by the Galactic satellites Booetes II and Segue 1 and 2, but no other known old stellar system. We use kinematic and color-magnitude criteria to identify 45 stars as possible members of Wil 1. With a systemic velocity of v{sub helio} = -12.8 {+-} 1.0 km s{sup -1}, Wil 1 stars have velocities similar to those of foreground Milky Way stars. Informed by Monte Carlo simulations, we identify 5 of the 45 candidate member stars as likely foreground contaminants, with a small number possibly remaining at faint apparent magnitudes. These contaminants could have mimicked a large velocity dispersion and abundance spread in previous work. The significant spread in the [Fe/H] of the highly likely Wil 1 red giant branch members ([Fe/H] = -1.73 {+-} 0.12 and -2.65 {+-} 0.12) supports the scenario that Wil 1 is an ultra-low luminosity dwarf galaxy, or the remnants thereof, rather than a star cluster. However, Wil 1's innermost stars move with radial velocities offset by 8 km s{sup -1} from its outer stars and have a velocity dispersion consistent with 0 km s{sup -1}, suggesting that Wil 1 may not be in dynamical equilibrium. The combination of the foreground contamination and unusual kinematic distribution make it difficult to robustly determine the dark matter mass of Wil 1. As a result, X-ray or gamma-ray observations of Wil 1 that attempt to constrain models of particle dark matter using an equilibrium mass model are strongly affected by the systematics in the observations presented here. We conclude that, despite the unusual features in the Wil 1 kinematic distribution, evidence indicates that this object is, or at least once was, a dwarf galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

High-speed Focal Plane Wave Front Sensing with an Optical Chopper

Focal plane wave front sensing and control is a critical approach to reducing noncommon path errors between a conventional astronomical adaptive optics (AO) wave front sensor (WFS) detector and a science camera. However, in addition to mitigating noncommon path errors, recent focal plane wave front sensing techniques have been developed to operate at speeds fast enough to enable "multi-WFS" AO, where residual atmospheric errors are further corrected by a focal plane WFS. Although a number of such techniques have been recently developed for coronagraphic imaging, here we present one designed for noncoronagraphic imaging. Utilizing conventional AO system components, this concept additionally requires (1) a detector imaging the focal plane of the WFS light source and (2) a pupil plane optical chopper device that is the noncommon path to the first WFS and is synchronized to the focal plane imager readout. These minimal hardware requirements enable the temporal amplitude modulation to resolve the sine ambiguity of even wave-front modes for low, mid, and high wave front spatial frequencies. Similar capabilities have been demonstrated with classical phase diversity by defocusing the detector, but such techniques are incompatible with simultaneous science observations. This optical chopping technique, however, enables science imaging at up to 50% duty cycle. In conclusion, we present both simulations and laboratory validation of this concept on SEAL, the Santa Cruz Extreme AO Laboratory testbed.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging of multiple fluorescent proteins in canopies enables synthetic biology in plants

Reverse genetics approaches have revolutionized plant biology and agriculture. Phenomics has the prospect of bridging plant phenotypes with genes, including transgenes, to transform agricultural fields. Genetically encoded fluorescent proteins (FPs) have revolutionized plant biology paradigms in gene expression, protein trafficking and plant physiology. While the first instance of plant canopy imaging of green fluorescent protein (GFP) was performed over 25 years ago, modern phenomics has largely ignored fluorescence as a transgene expression device despite the burgeoning FP colour palette available to plant biologists. Here, we show a new platform for stand-off imaging of plant canopies expressing a wide variety of FP genes. The platform-the fluorescence-inducing laser projector (FILP)-uses an ultra-low-noise camera to image a scene illuminated by compact diode lasers of various colours, coupled with emission filters to resolve individual FPs, to phenotype transgenic plants expressing FP genes. Each of the 20 FPs screened in plants were imaged at >3 m using FILP in a laboratory-based laser range. We also show that pairs of co-expressed fluorescence proteins can be imaged in canopies. The FILP system enabled a rapid synthetic promoter screen: starting from 2000 synthetic promoters transfected into protoplasts to FILP-imaged agroinfiltrated Nicotiana benthamiana plants in a matter of weeks, which was useful to characterize a water stress-inducible synthetic promoter. FILP canopy imaging was also accomplished for stably transformed GFP potato and in a split-GFP assay, which illustrates the flexibility of the instrument for analysing fluorescence signals in plant canopies.

abiotic stress↗

DUST DISTRIBUTION IN THE beta PICTORIS CIRCUMSTELLAR DISKS

We present three-dimensional models of dust distribution around beta Pictoris that produce the best fits to the Hubble Space Telescope/Advanced Camera for Surveys' images obtained by Golimowski and coworkers. We allow for the presence of either one or two separate axisymmetric dust disks. The density models are analytical, radial two power laws joined smoothly at a crossover radius with density exponentially decreasing away from the midplane of the disks. Two-disk models match the data best, yielding a reduced chi{sup 2} of approx1.2. Our two-disk model reproduces many of the asymmetries reported in the literature and suggests that it is the secondary (tilted) disk which is largely responsible for them. Our model suggests that the secondary disk is not constrained to the inner regions of the system (extending out to at least 250 AU) and that it has a slightly larger total area of dust than the primary, as a result of slower falloff of density with radius and height. This surprising result raises many questions about the origin and dynamics of such a pair of disks. The disks overlap, but can coexist owing to their low optical depths and therefore long mean collision times. We find that the two disks have dust replenishment times on the order of 10{sup 4} yr at approx100 AU, hinting at the presence of planetesimals that are responsible for the production of second generation dust. A plausible conjecture, which needs to be confirmed by physical modeling of the collisional dynamics of bodies in the disks, is that the two observed disks are derived from underlying planetesimal disks; such disks would be anchored by the gravitational influence of planets located at less than 70 AU from beta Pic that are themselves in slightly inclined orbits.

79 ASTRONOMY AND ASTROPHYSICS↗

POPULATION PARAMETERS OF INTERMEDIATE-AGE STAR CLUSTERS IN THE LARGE MAGELLANIC CLOUD. I. NGC 1846 AND ITS WIDE MAIN-SEQUENCE TURNOFF

The Advanced Camera for Surveys onboard the Hubble Space Telescope has been used to obtain deep, high-resolution images of the intermediate-age star cluster NGC 1846 in the Large Magellanic Cloud. We present new color-magnitude diagrams (CMDs) based on F435W, F555W, and F814W imaging. We test the previously observed broad main-sequence turnoff (MSTO) region for 'contamination' by field stars and (evolved) binary star systems. We find that while these impact the number of objects in this region, none can fully account for the large color spread. Our results therefore solidify the recent finding that stars in the MSTO region of this cluster have a large spread in color which is unrelated to measurement errors or contamination by field stars, and likely due to a {approx} 300 Myr range in the ages of cluster stars. An unbiased estimate of the stellar density distribution across the MSTO region shows that the spread is fairly continuous rather than strongly bimodal, as suggested previously. We fit the CMDs with several different sets of theoretical isochrones, and determine systematic uncertainties for population parameters when derived using any one set of isochrones. We note a degeneracy between age and [{alpha}/Fe], which can be lifted by matching the shape (curvature) of the full red giant branch (RGB) in the CMD. We find that stars in the upper part of the MSTO region are more centrally concentrated than those in any other region, including more massive RGB and asymptotic giant branch stars. We consider several possible formation scenarios which account for the unusual features observed in the CMD of NGC 1846.

79 ASTRONOMY AND ASTROPHYSICS↗

Vision ray calibration for the quantitative geometric description of general imaging and projection optics in metrology

Exact geometric calibration of optical devices like projectors or cameras is the basis for utilizing them in quantitative metrological applications. The common state-of-the-art photogrammetric pinhole-imaging-based models with supplemental polynomial corrections fail in the presence of nonsymmetric or high-spatial-frequency distortions and in describing caustics efficiently. These problems are solved by our vision ray calibration (VRC), which is proposed in this paper. The VRC takes an optical mapping system modeled as a black box and directly delivers corresponding vision rays for each mapped pixel. The underlying model, the calibration process, and examples are visualized and reviewed, demonstrating the potential of the VRC.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Multiplicity of M Dwarfs in Young Moving Groups

We image 104 newly identified low-mass (mostly M-dwarf) pre-main sequence (PMS) members of nearby young moving groups (YMGs) with Magellan Adaptive Optics (MagAO) and identify 27 stellar binaries with instantaneous projected separation as small as 40 mas. Fifteen were previously unknown. The total number of multiple systems in this sample including spectroscopic and visual binaries from the literature is 36, giving a raw stellar multiplicity rate of at least 35{sub −4}{sup +5}% for this population. In the separation range of roughly 1–300 au in which infrared AO imaging is most sensitive, the raw multiplicity rate is at least 24{sub −4}{sup +5}% for binaries resolved by the MagAO infrared camera (Clio). The M-star subsample of 87 stars yields a raw multiplicity of at least 30{sub −4}{sup +5}% over all separations, 21{sub −4}{sup +5}% for secondary companions resolved by Clio from 1 to 300 au (23{sub −4}{sup +5}% for all known binaries in this separation range). A combined analysis with binaries discovered by the Search for Associations Containing Young stars shows that stellar multiplicity fraction as a function of mass over the range of 0.2 to 1.2 M {sub ☉} appears to be linearly flat, in contrast to the field, where multiplicity increases with mass. After bias corrections are applied, the multiplicity of low-mass YMG members (0.2–0.6 M {sub ☉}) is in excess of the field. The overall multiplicity fraction is also consistent with being constant in age and across YMGs, which suggests that multiplicity rates for this mass range are largely set by 10 Myr without appreciable evolution thereafter.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative high dynamic range beam profiling for fluorescence microscopy

Modern developmental biology relies on optically sectioning fluorescence microscope techniques to produce non-destructive in vivo images of developing specimens at high resolution in three dimensions. As optimal performance of these techniques is reliant on the three-dimensional (3D) intensity profile of the illumination employed, the ability to directly record and analyze these profiles is of great use to the fluorescence microscopist or instrument builder. Though excitation beam profiles can be measured indirectly using a sample of fluorescent beads and recording the emission along the microscope detection path, we demonstrate an alternative approach where a miniature camera sensor is used directly within the illumination beam. Measurements taken using our approach are solely concerned with the illumination optics as the detection optics are not involved. We present a miniature beam profiling device and high dynamic range flux reconstruction algorithm that together are capable of accurately reproducing quantitative 3D flux maps over a large focal volume. Performance of this beam profiling system is verified within an optical test bench and demonstrated for fluorescence microscopy by profiling the low NA illumination beam of a single plane illumination microscope. The generality and success of this approach showcases a widely flexible beam amplitude diagnostic tool for use within the life sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Towards a new generation long trace profiler LTP-2020: optical design of pencil beam interferometry sensor

Improvements in the quality of synchrotron beamline x-ray optics required for next-generation light sources (e.g. the ALS Upgrade project) drive the need to improve the performance of the metrology instrumentation used to measure these components. The Long Trace Profiler (LTP) that is in use at many synchrotron metrology laboratories around the world has some known issues that affect the accuracy of its measurements. The main error source is optical path difference (OPD) phase error introduced into the probe beam by inhomogeneities in the glass components used in the optical head. We have developed a new optical head design, LTP-2020, that replaces the cube polarizing beamsplitter (PBS) with a thin wedge plate polarizing beamsplitter (WPBS) and replaces the cemented doublet lens with an aspheric singlet. Both of these components significantly reduce the glass volume traversed by the laser probe beam. Careful attention to ghost ray interference produced by back reflection from optical surfaces is necessary to minimize distortion in the primary image that translates into systematic error in the slope angle measurement. We make extensive use of a commercial raytracing program to model the back reflections and adjust component parameters as necessary to minimize distortion. Deliberate misalignment of components is necessary to make the system perform correctly. Stringent requirements are placed on the 45◦ incidence coatings on the WPBS and on the normal incidence coatings on the lens and camera window elements. We encourage our colleagues who wish to upgrade their current LTP systems to join us in the procurement of these custom optical components.

Takacs, Peter Z.↗

3-D Semantic Information Inference from Airborne Video. Final Report

We developed a full 3D modeling pipeline focusing on an important application scenario: city-scale 3D reconstruction from aerial imagery. We propose an approach to solve camera pose estimation and dense reconstruction from Wide Area Aerial Surveillance (WAAS) videos captured by an airborne platform. Our approach solves them in an online fashion: it incrementally updates a sparse 3D map and estimates the camera pose as each new frame arrives; depth maps of selected key frames are computed using a variational method and integrated to produce a full 3D model via volumetric reconstruction. In practice, aerial imagery is usually captured using a multicamera system. We propose an approach for camera pose estimation of multi-camera aerial imagery which is parallelized on multiple GPUs for efficiency. The approach is also extended for progressive 3D model acquisition with a hand-held camera. We also developed an offline approach since online approach is not a necessity and accuracy has higher priority over efficiency in many scenarios. We presented MeshRecon, a mesh-based offline system composed of three modules: a dense point cloud is generated using multi-resolution plane sweep method; an initial mesh model is extracted from the point cloud via global optimization considering visibility information of all images; the mesh model is then iteratively refined to capture structural details by optimizing the photometric consistency and spatial regularization. The major processes are parallelized on GPU for efficiency. For the aerial imagery case, we evaluate our system on several real-world multicamera aerial imagery datasets, each covering an urban scenario of several square kilometers. Quantitative result shows that the reconstructed geometric 3D model is highly accurate with error smaller than 1 meter over the entire city. Besides aerial imagery, we also evaluate its performance on general geometric 3D model acquisition of real-world objects. Result shows that the system is robust and flexible for various types of objects at different scales in both indoor and outdoor environments. Based on city 3D models reconstructed at different times, we present a system for city-scale geometry change detection by performing comparisons at the 3D geometry level. Our system is able to detect geometry changes at different scales, ranging from a building cluster to small-scale vegetation changes, with high accuracy.

97 MATHEMATICS AND COMPUTING↗

Optical Relays for Imaging Scintillators

Cygnus is a dual beam high-energy radiographic x-ray source. Ten years ago, three large zoom lenses were assembled to collect images from 200 mm x 200 mm square scintillators. The zoom capability allows zooming down to a 60 mm x 60 mm picture from the scintillator. Current radiographic imaging needs now require larger 270 mm x 270 mm square scintillators and the capability to use both 92 mm x 92 mm and 62 mm x 62 mm CCD cameras, and a new lens design to meet these needs. This zoom lens incorporates 11 elements and is designed to be telecentric. It images a scintillator emitting light peaking at 435 nm, so special glass types are required for the lens elements. Much larger elliptical pellicles are needed to deflect the scintillator light out of the x-ray path into the lens. The optical axis of the imaging system must be colinear with the x-ray axis. Two scintillators are positioned in each of two Cygnus x-ray axes, for a total of four scintillators and four lens systems. An optional configuration will be shown, enabling two lens systems imaging opposite sides of a single scintillator, for a total of four lenses and two scintillators. Although this configuration has advantages, it suffers from crosstalk. Care must be taken to analyze the anti-reflection coatings applied to all the elements in the imaging chain, including the CCD array and

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time Defect Correction in Large-Scale Polymer Additive Manufacturing via Thermal Imaging and Laser Profilometer

Defects can result in a failed part and are costly in terms of time and material. This cost is even greater in the context of large-scale additive manufacturing where the objects can be very large. As a result, a great deal of research has focused on defect identification and mitigation. To address defects during object construction, researchers at Oak Ridge National Laboratory’s Manufacturing Demonstration Facility investigated an in-situ control system comprised of two sensors: a thermal camera and laser profilometer. This control system adjusted material flow and build speed to mitigate three types of defects: low layer times, underfill, and overfill. Several test objects were constructed. The control system was found to adjust build parameters to handle low layer times of approximately 15 seconds and height deviations from -100% underfill (the absence of a layer) to 50% overfill. Within two layers, height deviations could be returned to within 10% of the expected layer height. Further, preliminary results suggest the system can compensate for uneven build surfaces.

Borish, Michael↗

Cherenkov Video Imaging Allows for the First Visualization of Radiation Therapy in Real Time

Purpose: To determine whether Cherenkov light imaging can visualize radiation therapy in real time during breast radiation therapy. Methods and Materials: An intensified charge-coupled device (CCD) camera was synchronized to the 3.25-μs radiation pulses of the clinical linear accelerator with the intensifier set × 100. Cherenkov images were acquired continuously (2.8 frames/s) during fractionated whole breast irradiation with each frame an accumulation of 100 radiation pulses (approximately 5 monitor units). Results: The first patient images ever created are used to illustrate that Cherenkov emission can be visualized as a video during conditions typical for breast radiation therapy, even with complex treatment plans, mixed energies, and modulated treatment fields. Images were generated correlating to the superficial dose received by the patient and potentially the location of the resulting skin reactions. Major blood vessels are visible in the image, providing the potential to use these as biological landmarks for improved geometric accuracy. The potential for this system to detect radiation therapy misadministrations, which can result from hardware malfunction or patient positioning setup errors during individual fractions, is shown. Conclusions: Cherenkoscopy is a unique method for visualizing surface dose resulting in real-time quality control. We propose that this system could detect radiation therapy errors in everyday clinical practice at a time when these errors can be corrected to result in improved safety and quality of radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗