FY-13 Progress Report on the Cleanup of Irradiated 130 g-U/L Uranyl Sulfate SHINE Target Solutions
So far during Fiscal Year 2013 (FY-13) Argonne National Laboratory (Argonne) has refined the cleanup process for irradiated SHINE Target Solutions (STS). This includes the following: 1. Refinement of the sulfate-to-nitrate conversion step using a combination of both strontium and barium nitrate [Sr(NO 3 ) 2 and Ba(NO 3 ) 2 , respectively] at 60° C. 2. Testing of the sulfate to nitrate conversion on large volumes of irradiated STS. 3. Testing of UREX on irradiated STS. This report will present results from various experiments to determine the most suitable sulfate-to-nitrate conversion conditions, the results for a scale-up experiments with an STS, and the results from a UREX experiment on an STS.