Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material point method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

A map of single-phase high-entropy alloys

High-entropy alloys have exhibited unusual materials properties. The stability of equimolar single-phase solid solution of five or more elements is supposedly rare and identifying the existence of such alloys has been challenging because of the vast chemical space of possible combinations. Herein, based on high-throughput density-functional theory calculations, we construct a chemical map of single-phase equimolar high-entropy alloys by investigating over 658,000 equimolar quinary alloys through a binary regular solid-solution model. We identify 30,201 potential single-phase equimolar alloys (5% of the possible combinations) forming mainly in body-centered cubic structures. We unveil the chemistries that are likely to form high-entropy alloys, and identify the complex interplay among mixing enthalpy, intermetallics formation, and melting point that drives the formation of these solid solutions. We demonstrate the power of our method by predicting the existence of two new high-entropy alloys, i.e. the body-centered cubic AlCoMnNiV and the face-centered cubic CoFeMnNiZn, which are successfully synthesized.

36 MATERIALS SCIENCE↗

Preparation and thermophysical properties of (Sm{sub 1−x}Er{sub x}){sub 2}Ce{sub 2}O{sub 7} oxides for thermal barrier coatings

Graphical abstract: - Highlights: • These ceramic materials with fluorite structure were synthesized. • Defect points lead to their lower thermal conductivities. • The lower ionic radius of Er{sup 3+} ion leads to the reduction of thermal expansion coefficient of (Sm{sub 1−x}Er{sub x}){sub 2}Ce{sub 2}O{sub 7} oxides. - Abstract: (Sm{sub 1−x}Er{sub x}){sub 2}Ce{sub 2}O{sub 7} ceramics were synthesized by sol–gel method and sintered at 1600 °C for 10 h in air. The influence of Er{sub 2}O{sub 3}-substitution on the phase structure and thermophysical properties of Sm{sub 2}Ce{sub 2}O{sub 7} was investigated. The phase structures of these ceramics were identified by X-ray diffraction showing that all synthesized ceramics have fluorite-type structure. The measurements for thermophysical properties of these ceramics show that their thermal conductivities and thermal expansion coefficients remarkably decreased through Er-substitution. However, the thermal expansion coefficients were higher than that of YSZ and their thermal conductivities were much lower than that of 8YSZ. The excellent thermophysical property implies that these solid solutions are potential materials for the ceramics layer in thermal barrier coatings.

36 MATERIALS SCIENCE↗

Daylight simulation workflows incorporating measured bidirectional scattering distribution functions

Daylight predictions of architectural spaces depend on good estimates of light transfer through skylights, windows and other fenestration systems. For clear glazing and painted surfaces, parametric transmission and reflection models have proven adequate, but there are many cases where light-scattering, semi-specular shading and daylighting materials defy simple characterization. Something as commonplace as fabric roller shades and venetian blinds may turn daylight prediction into guesswork, and numerous advanced systems on the market tuned specifically to enhance daylight are not sufficiently characterized to distinguish their performance. In this paper, we describe new tools available to handle novel and specialized fabrics, materials, and devices using data-driven modelling of bi-directional scattering distribution functions (BSDFs). These representations are usually tabulated at constant or adjustable angular resolution for efficient point-in-time and annual daylight simulations. We describe a variety of BSDF simulation workflows, including some of the tools and methods that make advanced analysis possible, and highlight some of the current challenges. We conclude with a discussion of future work and how such data might be created and shared worldwide.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiotherapy and Hyperthermia for Treatment of Primary Locally Advanced Cervix Cancer: Results in 378 Patients

Purpose: To report response rate, pelvic tumor control, survival, and late toxicity after treatment with combined radiotherapy and hyperthermia (RHT) for patients with locally advanced cervical carcinoma (LACC) and compare the results with other published series. Methods and Materials: From 1996 to 2005, a total of 378 patients with LACC (International Federation of Gynecology and Obstetrics Stage IB2-IVA) were treated with RHT. External beam radiotherapy (RT) was applied to 46-50.4 Gy and combined with brachytherapy. The hyperthermia (HT) was prescribed once weekly. Primary end points were complete response (CR) and local control. Secondary end points were overall survival, disease-specific survival, and late toxicity. Patient, tumor, and treatment characteristics predictive for the end points were identified in univariate and multivariate analyses. Results: Overall, a CR was achieved in 77% of patients. At 5 years, local control, disease-specific survival, and incidence of late toxicity Common Terminology Criteria for Adverse Events Grade 3 or higher were 53%, 47%, and 12%, respectively. In multivariate analysis, number of HT treatments emerged as a predictor of outcome in addition to commonly identified prognostic factors. Conclusions: The CR, local control, and survival rates are similar to previously observed results of RHT in the randomized Dutch Deep Hyperthermia Trial. Reported treatment results for currently applied combined treatment modalities (i.e., RT with chemotherapy and/or HT) do not permit definite conclusions about which combination is superior. The present results confirm previously shown beneficial effects from adding HT to RT and justify the application of RHT as first-line treatment in patients with LACC as an alternative to chemoradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Concurrent Chemoradiotherapy With Paclitaxel and Nedaplatin Followed by Consolidation Chemotherapy in Locally Advanced Squamous Cell Carcinoma of the Uterine Cervix: Preliminary Results of a Phase II Study

Purpose: To evaluate the efficacy and toxicities of concurrent chemoradiotherapy (CCRT) and consolidation chemotherapy in patients with locally advanced squamous cell cervical carcinoma. Methods and Materials: Patients with LASCC (FIGO Stage IIB-IIIB) were treated with pelvic external beam radiotherapy (45 Gy for Stage IIB and 50 Gy for Stage III) and high-dose-rate intracavitary brachytherapy (50 Gy for Stage IIB and 35 Gy for Stage III). The cumulative dose at point A was 50 Gy for Stage IIB and 65 Gy for Stage III. Concurrent chemotherapy with paclitaxel (35 mg/m{sup 2}) and nedaplatin (20 mg/m{sup 2}) was given every week for 6 weeks. Consolidation chemotherapy with paclitaxel (135 mg/m{sup 2}) and nedaplatin (60 mg/m{sup 2}) was administered every 3 weeks for 4 cycles. Results: All patients completed CCRT, and 28 of 34 patients completed consolidation chemotherapy. The complete response rate was 88% (95% CI, 73-96%). The most common Grade 3 or higher toxicities were leukopenia/neutropenia (10.9% of the cycles). During a median follow up of 23 months (range, 14-30 months), 5 patients had locoregional failure and 1 patient had distant metastasis. The estimated 2-year progression-free survival and overall survival were 82% (95% CI, 68-95%) and 93% (95% CI, 83-100%), respectively. Grade 3 late complications occurred in 3 patients (9%). Conclusions: CCRT with paclitaxel and nedaplatin followed by consolidation chemotherapy is well tolerated and effective in patients with locally advanced squamous cell cervical carcinoma. Further randomized trials of comparing this regimen with the standard treatment are worth while.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Body Mass Index on Intrafraction Prostate Displacement Monitored by Real-Time Electromagnetic Tracking

Purpose: To evaluate, using real-time monitoring of implanted radiofrequency transponders, the intrafraction prostate displacement of patients as a function of body mass index (BMI). Methods and Materials: The motions of Beacon radiofrequency transponders (Calypso Medical Technologies, Seattle, WA) implanted in the prostate glands of 66 men were monitored throughout the course of intensity modulated radiation therapy. Data were acquired at 10 Hz from setup to the end of treatment, but only the 1.7 million data points with a 'beam on' tag were used in the analysis. There were 21 obese patients, with BMI {>=}30 and 45 nonobese patients in the study. Results: Mean displacements were least in the left-right lateral direction (0.56 {+-} 0.24 mm) and approximately twice that magnitude in the superior-inferior and anterior-posterior directions. The net vector displacement was larger still, 1.95 {+-} 0.47 mm. Stratified by BMI cohort, the mean displacements per patient in the 3 Cartesian axes as well as the net vector for patients with BMI {>=}30 were slightly less (<0.2 mm) but not significantly different than the corresponding values for patients with lower BMIs. As a surrogate for the magnitude of oscillatory noise, the standard deviation for displacements in all measured planes showed no significant differences in the prostate positional variability between the lower and higher BMI groups. Histograms of prostate displacements showed a lower frequency of large displacements in obese patients, and there were no significant differences in short-term and long-term velocity distributions. Conclusions: After patients were positioned accurately using implanted radiofrequency transponders, the intrafractional displacements in the lateral, superior-inferior, and anterior-posterior directions as well as the net vector displacements were smaller, but not significantly so, for obese men than for those with lower BMI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detailed Characterization of the Early Response of Head-Neck Cancer Xenografts to Irradiation Using {sup 18}F-FDG-PET Imaging

Purpose: To investigate the metabolic information provided by {sup 18}F-fluorodeoxyglucose-positron emission tomography (FDG-PET) during the early response of head-and-neck squamous cell carcinoma (HNSCC) xenografts to radiotherapy (RT). Methods and Materials: Low-passage HNSCC cells (UT14) were injected into the rear flanks of female nu/nu mice to generate xenografts. After tumors grew to 400-500 mm{sup 3}, they were treated with either 15 Gy in one fraction (n = 18) or sham RT (n = 12). At various time points after treatment, tumors were assessed with 2-h dynamic FDG-PET and immediately harvested for direct histological correlation. Different analytical parameters were used to process the dynamic PET data: kinetic index (Ki), standard uptake value (SUV), sensitivity factor (SF), and retention index (RI). Tumor growth was assessed using the specific growth rate (SGR) and correlated with PET parameters using the Pearson correlation coefficient (r). Receiver operating characteristic (ROC) and the area under the ROC curve (AUC) were used to test PET parameters for their ability to predict for radiation necrosis and radiation change. Results: Tumor growth was arrested for the first 20 days after RT and recovered thereafter. Histologically, radiation change was observed in the peripheral regions of tumors between days 7 and 23 after RT, and radiation necrosis were observed in the central regions of tumors between days 7 and 40. Ki provided the best correlation with SGR (r = 0.51) and was the optimal parameter to predict for early radiation necrosis (AUC = 0.804, p = 0.07). SUV{sub 30min} was the strongest predictor for late radiation necrosis (AUC = 0.959, p = 0.004). Both RI{sub 30-60min} and SF{sub 12-70min} were very accurate in predicting for radiation change (AUC = 0.891 and 0.875, p = 0.009 and 0.01, respectively). Conclusions: Dynamic FDG-PET analysis (such as Ki or SF) may provide informative assessment of early radiation necrosis or radiation change of HNSCC xenografts after RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temporal Evolution and Dose-Volume Histogram Predictors of Visual Acuity After Proton Beam Radiation Therapy of Uveal Melanoma

Purpose: To perform an in-depth temporal analysis of visual acuity (VA) outcomes after proton beam radiation therapy (PBRT) in a large, uniformly treated cohort of uveal melanoma (UM) patients, to determine trends in VA evolution depending on pretreatment and temporally defined posttreatment VA measurements; and to investigate the relevance of specific patient, tumor and dose-volume parameters to posttreatment vision loss. Methods and Materials: Uveal melanoma patients receiving PBRT were identified from a prospectively maintained database. Included patients (n=645) received 56 GyE in 4 fractions, had pretreatment best corrected VA (BCVA) in the affected eye of count fingers (CF) or better, with posttreatment VA assessment at specified post-PBRT time point(s). Patients were grouped according to the pretreatment BCVA into favorable (≥20/40) or unfavorable (20/50-20/400) and poor (CF) strata. Temporal analysis of BCVA changes was described, and univariate and forward stepwise multivariate logistic regression analyses were performed to identify predictors for VA loss. Results: Median VA follow-up was 53 months (range, 3-213 months). At 60-month follow up, among evaluable treated eyes with favorable pretreatment BCVA, 45% retained BCVA ≥20/40, whereas among evaluable treated eyes with initially unfavorable/poor BCVA, 21% had vision ≥20/100. Among those with a favorable initial BCVA, attaining BCVA of ≥20/40 at any posttreatment time point was associated with subsequent maintenance of excellent BCVA. Multivariate analysis identified volume of the macula receiving 28GyE (P<.0001) and optic nerve (P=.0004) as independent dose-volume histogram predictors of 48-month post-PBRT vision loss among initially favorable treated eyes. Conclusions: Approximately half of PBRT-treated UM eyes with excellent pretreatment BCVA assessed at 5 years after treatment will retain excellent long-term vision. 28GyE macula and optic nerve dose-volume histogram parameters allow for rational treatment planning optimization that may lead to improved visual outcomes. The detailed temporal analysis with intermediate as well as long-term functional prognosis, and the relationship of outcomes with clinical and treatment planning parameters, is critical for informed care of UM patients before and after PBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hybrid functional calculation of electronic and phonon structure of BaSnO{sub 3}

Barium stannate, BaSnO{sub 3} (BSO), with a cubic perovskite structure, has been highlighted as a promising host material for the next generation transparent oxide electrodes. This study examined theoretically the electronic structure and phonon structure of BSO using hybrid density functional theory based on the HSE06 functional. The electronic structure results of BSO were corrected by extending the phonon calculations based on the hybrid density functional. The fundamental thermal properties were also predicted based on a hybrid functional calculation. Overall, a detailed understanding of the electronic structure, phonon modes and phonon dispersion of BSO will provide a theoretical starting-point for engineering applications of this material. - Graphical Abstract: (a) Crystal structure of BaSnO{sub 3}. The center ball is Ba and small (red) ball on edge is oxygen and SnO{sub 6} octahedrons are plotted as polyhedron. (b) Electronic band structure along the high symmetry point in the Brillouin zone using the HSE06 hybrid functional. (c) The phonon dispersion curve calculated using the HSE06 hybrid functional (d) Zone center lowest energy F{sub 1u} phonon mode. Highlights: Black-Right-Pointing-Pointer We report the full hybrid functional calculation of not only the electronic structure but also the phonon structure for BaSnO{sub 3}. Black-Right-Pointing-Pointer The band gap calculation of HSE06 revealed an indirect gap with 2.48 eV. Black-Right-Pointing-Pointer The effective mass at the conduction band minimum and valence band maximum was calculated. Black-Right-Pointing-Pointer In addition, the phonon structure of BSO was calculated using the HSE06 functional. Black-Right-Pointing-Pointer Finally, the heat capacity was calculated and compared with the recent experimental result.

36 MATERIALS SCIENCE↗

Electronic and structural influence of Ni by Pd substitution on the hydrogenation properties of TiNi

In Ti (Ni,Pd) compounds, the hydrogen capacity and the stability of their hydrides decreases when Ni is partially substituted by larger in size Pd atoms. To understand this peculiar behaviour, the crystal structure of TiNi{sub 1-x}Pd{sub x}D{sub y} (x=0.1, 0.3 and 0.5) deuterides and the stability of TiNi{sub 1-x}Pd{sub x} (0{<=}x{<=}0.5) intermetallics and their hydrides have been investigated by both neutron diffraction experiments and Density Functional Theory (DFT) calculations. Neutron diffraction shows that at x=0.1 and 0.3, deuterium absorption induces tetragonal distortion in intermetallics sublattice whereas at x=0.5 the cubic symmetry is preserved. The structural properties and the heat of formation of TiNi{sub 1-x}Pd{sub x} (0{<=}x{<=}0.5) intermetallics and their hydrides have been determined by DFT. These results show that Pd substitution increases the stability of the intermetallics and decreases the stability of the hydrides, which confirms the rule of reverse stability. - Graphical abstract: Crystal structure of Ti(Ni,Pd)Hy hydrides in the I4/mmm space group. Highlights: Black-Right-Pointing-Pointer Neutron Diffraction and DFT calculations have been done on TiNi{sub 1-x}Pd{sub x}H{sub y} compounds. Black-Right-Pointing-Pointer Electronic effect of Pd substitution governs the hydrogenation properties in TiNi. Black-Right-Pointing-Pointer The rule of reverse stability in intermetallics/hydrides is observed with Pd substitution. Black-Right-Pointing-Pointer The hydrogen atoms in the I4/mmm structure prefer to occupy the 16n site.

36 MATERIALS SCIENCE↗

Neutron crosstalk between liquid scintillators

We propose a method to quantify the fractions of neutrons scattering between liquid scintillators. Using a spontaneous fission source, this method can be utilized to quickly characterize an array of liquid scintillators in terms of crosstalk. The point model theory due to Feynman is corrected to account for these multiple scatterings. Using spectral information measured by the liquid scintillators, fractions of multiple scattering can be estimated, and mass reconstruction of fissile materials under investigation can be improved. Monte Carlo simulations of mono-energetic neutron sources were performed to estimate neutron crosstalk. A californium source in an array of liquid scintillators was modeled to illustrate the improvement of the mass reconstruction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Photoluminescence study on heavily donor and acceptor impurity doped GaAs layers grown by molecular-beam epitaxy

Gallium arsenide layers doped with high concentrations of Be and Si by molecular-beam epitaxy are studied by photoluminescence (PL) spectroscopy. PL peaks from doped layers are observed at energies significantly lower than the band-gap of GaAs. The growth and doping conditions suggest that the origin of these peaks is different from that of low energy PL peaks, which were observed in earlier studies and attributed to impurity-vacancy complexes. The dependence of the peak energy on the temperature and the annealing is found to differ from that of the peaks attributed to impurity-vacancy complexes. On the basis of these observations, it is suggested that the low energy peaks are attributed to short range ordered arrangements of impurity ions. This possibility is examined by calculations of the PL spectra with models of pairs of acceptor and donor delta-doped layers and PL experiments of a superlattice of pairs of Be and Si delta-doped layers.

36 MATERIALS SCIENCE↗

IR studies of the impact of Ge doping on the successive conversion of VO{sub n} defects in Czochralski-Si containing carbon

We report infrared absorption studies of oxygen-related defects in electron-irradiated Ge-doped Czochralski-Si. Our investigation was mainly focused on the reaction channel leading to the formation of VO{sub n} (1{<=}n{<=}6) defects. The VO{sub n} defects form mainly upon annealing, as a result of the successive aggregation of oxygen atoms in the initial VO defect produced by the irradiation: (VO+O{sub i}{yields}VO{sub 2}+O{sub i}{yields}VO{sub 3}+O{sub i}{yields}VO{sub 4},...). It was found that the ratio of the conversion of VO{sub n} to VO{sub n+1} defects is sensitive to the Ge content of the material. In particular, the ratio of the conversion of the VO to the VO{sub 2} defects was found to decrease with the increase in Ge concentration of the samples, although the opposite trend was observed for the VO{sub 3} to VO{sub 4} conversion. However, the VO{sub 2} to VO{sub 3} conversion changes only slightly with Ge content, being practically unaffected for Ge concentrations up to 2x10{sup 20} cm{sup -3}. In the case of VO{sub 2} formation, the phenomenon was attributed to the elastic strains induced in the lattice due to the Ge presence which affects the balance between the reactions VO+O{sub i}{yields}VO{sub 2}, VO+Si{sub I}{yields}O{sub i}, mainly involved in the decay of the VO and the growth of the VO{sub 2} defects. In the case of VO{sub 4} formation, the phenomenon was discussed by taking into account the enhancement of the diffusivity of the O{sub i} atoms in the Ge-doped Si, which could lead to an enhancement of the rate of the reaction VO{sub 3}+O{sub i}{yields}VO{sub 4}. For the VO{sub 3} formation this effect is practically negligible due to the fact that at the temperatures of VO{sub 2} to VO{sub 3} conversion oxygen diffusivity is quite small. The exhibited behavior in the conversion of the VO{sub n} to VO{sub n+1} defects (n=1,2,3) was similar in Ge-doped samples with low carbon content ([C{sub s}]<2x10{sup 16} cm{sup -3}) and in Ge-doped samples with high carbon content ([C{sub s}]{>=}1x10{sup 17} cm{sup -3}). The impact of C as well as its role in the conversion efficiency of VO to VO{sub 2} was studied by comparing the spectra in low carbon and high carbon Ge free Si material. Furthermore, a pair of bands at (1037,1051 cm{sup -1}) was attributed to the VO{sub 5} defect. The origin of another pair of bands (967,1005 cm{sup -1}) was discussed and tentatively correlated with a VO{sub n}C{sub s} structure. The role of Ge and C in the formation of the latter two pairs of bands was discussed.

36 MATERIALS SCIENCE↗

Optoelectronic response and excitonic properties of monolayer MoS{sub 2}

Ab initio, electronic energy bands of MoS{sub 2} single layer are reported within the local density functional approximation. The inclusion of spin orbit coupling reveals the presence of two excitons A and B. We also discuss the change of physical properties of MoS{sub 2} from multilayer and bulk counterparts. The nature of the band gap changes from indirect to direct when the thickness is reduced to a single monolayer. The imaginary and real dielectric functions are investigated. Refractive index and birefringence are also reported. The results suggest that MoS{sub 2} is suitable for potential applications in optoelectronic and photovoltaic devices. The ab initio study is essential to propose the crucial parameters for the analytical model used for A-B exciton properties of the monolayer MoS{sub 2}. From a theoretical point of view, we consider how the exciton behavior evolves under environmental dielectrics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diffusion in Coulomb crystals

Diffusion in Coulomb crystals can be important for the structure of neutron star crusts. We determine diffusion constants D from molecular dynamics simulations. We find that D for Coulomb crystals with relatively soft-core 1/r interactions may be larger than D for Lennard-Jones or other solids with harder-core interactions. Diffusion, for simulations of nearly perfect body-centered-cubic lattices, involves the exchange of ions in ringlike configurations. Here ions ''hop'' in unison without the formation of long lived vacancies. Diffusion, for imperfect crystals, involves the motion of defects. Finally, we find that diffusion, for an amorphous system rapidly quenched from Coulomb parameter {Gamma}=175 to Coulomb parameters up to {Gamma}=1750, is fast enough that the system starts to crystalize during long simulation runs. These results strongly suggest that Coulomb solids in cold white dwarf stars, and the crust of neutron stars, will be crystalline and not amorphous.

36 MATERIALS SCIENCE↗

Tissue equivalency of phantom materials for neutron dosimetry in proton therapy

Purpose: Previous Monte Carlo and experimental studies involving secondary neutrons in proton therapy have employed a number of phantom materials that are designed to represent human tissue. In this study, the authors determined the suitability of common phantom materials for dosimetry of secondary neutrons, specifically for pediatric and intracranial proton therapy treatments. Methods: This was achieved through comparison of the absorbed dose and dose equivalent from neutrons generated within the phantom materials and various ICRP tissues. The phantom materials chosen for comparison were Lucite, liquid water, solid water, and A150 tissue equivalent plastic. These phantom materials were compared to brain, muscle, and adipose tissues. Results: The magnitude of the doses observed were smaller than those reported in previous experimental and Monte Carlo studies, which incorporated neutrons generated in the treatment head. The results show that for both neutron absorbed dose and dose equivalent, no single phantom material gives agreement with tissue within 5% at all the points considered. Solid water gave the smallest mean variation with the tissues out of field where neutrons are the primary contributor to the total dose. Conclusions: Of the phantom materials considered, solid water shows best agreement with tissues out of field.

61 RADIATION PROTECTION AND DOSIMETRY↗

Least squares parameter estimation methods for material decomposition with energy discriminating detectors

Purpose: Energy resolving detectors provide more than one spectral measurement in one image acquisition. The purpose of this study is to investigate, with simulation, the ability to decompose four materials using energy discriminating detectors and least squares minimization techniques. Methods: Three least squares parameter estimation decomposition techniques were investigated for four-material breast imaging tasks in the image domain. The first technique treats the voxel as if it consisted of fractions of all the materials. The second method assumes that a voxel primarily contains one material and divides the decomposition process into segmentation and quantification tasks. The third is similar to the second method but a calibration was used. The simulated computed tomography (CT) system consisted of an 80 kVp spectrum and a CdZnTe (CZT) detector that could resolve the x-ray spectrum into five energy bins. A postmortem breast specimen was imaged with flat panel CT to provide a model for the digital phantoms. Hydroxyapatite (HA) (50, 150, 250, 350, 450, and 550 mg/ml) and iodine (4, 12, 20, 28, 36, and 44 mg/ml) contrast elements were embedded into the glandular region of the phantoms. Calibration phantoms consisted of a 30/70 glandular-to-adipose tissue ratio with embedded HA (100, 200, 300, 400, and 500 mg/ml) and iodine (5, 15, 25, 35, and 45 mg/ml). The x-ray transport process was simulated where the Beer-Lambert law, Poisson process, and CZT absorption efficiency were applied. Qualitative and quantitative evaluations of the decomposition techniques were performed and compared. The effect of breast size was also investigated. Results: The first technique decomposed iodine adequately but failed for other materials. The second method separated the materials but was unable to quantify the materials. With the addition of a calibration, the third technique provided good separation and quantification of hydroxyapatite, iodine, glandular, and adipose tissues. Quantification with this technique was accurate with errors of 9.83% and 6.61% for HA and iodine, respectively. Calibration at one point (one breast size) showed increased errors as the mismatch in breast diameters between calibration and measurement increased. A four-point calibration successfully decomposed breast diameter spanning the entire range from 8 to 20 cm. For a 14 cm breast, errors were reduced from 5.44% to 1.75% and from 6.17% to 3.27% with the multipoint calibration for HA and iodine, respectively. Conclusions: The results of the simulation study showed that a CT system based on CZT detectors in conjunction with least squares minimization technique can be used to decompose four materials. The calibrated least squares parameter estimation decomposition technique performed the best, separating and accurately quantifying the concentrations of hydroxyapatite and iodine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Agile Design-to-Simulation Workflow Using a New Conforming Moving Least Squares Method

This report summarizes the accomplishments and challenges of a two year LDRD effort focused on improving design-to-simulation agility. The central bottleneck in most solid mechanics simulations is the process of taking CAD geometry and creating a discretization of suitable quality, i.e., the "meshing" effort. This report revisits meshfree methods and documents some key advancements that allow their use on problems with complex geometries, low quality meshes, nearly incompressible materials or that involve fracture. The resulting capability was demonstrated to be an effective part of an agile simulation process by enabling rapid discretization techniques without increasing the time to obtain a solution of a given accuracy. The first enhancement addressed boundary-related challenges associated with meshfree methods. When using point clouds and Euclidean metrics to construct approximation spaces, the boundary information is lost, which results in low accuracy solutions for non-convex geometries and mate rial interfaces. This also complicates the application of essential boundary conditions. The solution involved the development of conforming window functions which use graph and boundary information to directly incorporate boundaries into the approximation space.

42 ENGINEERING↗