Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Characterising CCDs with cosmic rays

The properties of cosmic ray muons make them a useful probe for measuring the properties of thick, fully depleted CCD sensors. The known energy deposition per unit length allows measurement of the gain of the sensor's amplifiers, whilst the straightness of the tracks allows for a crude assessment of the static lateral electric fields at the sensor's edges. The small volume in which the muons deposit their energy allows measurement of the contribution to the PSF from the diffusion of charge as it drifts across the sensor. In this work we present a validation of the cosmic ray gain measurement technique by comparing with radioisotope gain measurments, and calculate the charge diffusion coefficient for prototype LSST sensors.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the tt production cross section with an in situ calibration of b-jet identification efficiency

A measurement of the top-quark pair-production cross section in pp collisions at {radical}(s)=1.96 TeV using data corresponding to an integrated luminosity of 1.12 fb{sup -1} collected with the Collider Detector at Fermilab is presented. Decays of top-quark pairs into the final states e{nu}+ jets and {mu}{nu}+ jets are selected, and the cross section and the b-jet identification efficiency are determined using a new measurement technique which requires agreement between the measured cross sections with exactly one and with multiple identified b quarks from the top-quark decays. Assuming a top-quark mass of 175 GeV/c{sup 2}, a cross section of 8.5{+-}0.6(stat){+-}0.7(syst)pb is measured.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TU-F-BRE-04: Development of a High-Resolution EPID Based Dosimetry Strategy for Radiosurgery QA

Purpose: To systematically investigate a high spatial-resolution (0.2mm) electronic portal imaging device (EPID) for CyberKnife (CK) based radiosurgery system quality assurance (QA). Methods: An EPID-based dosimetric measurement technique is applied to CK output measurement and field size verification. A Monte Carlo (MC) simulated pixel-to-pixel EPID response specific to CK is used to convert a raw EPID-measured image of a radiosurgery field into water-based dose distribution. The output factors are measured using EPID for radiosurgery fields formed by fixed and variable aperture (Iris) cones. Circular fields of 5, 7.5, 10, 15, 30 and 60mm diameters are measured and compared with diode measurements. The equivalent diameters are determined by analyzing the area received dose greater than half maximum. Results: For both fixed and Iris cones, the EPID measured output factors of circular fields of 5mm to 60mm diameters are in good agreement with the radiosurgery diode measurements. The mean output differences are 1.0% and 1.5% for fixed and Iris cone respectively. The max differences are 2.2% for the 15mm fixed cone, and 1.8% for the 10mm Iris field. The equivalent diameters derived from the EPID measurements are in good agreement comparing to the water scan result with mean differences of 0.21±0.09mm and 0.02±0.22mm for fixed and Iris cone, respectively. The high detector density EPID is able to measure the whole radiation field and identify the field edge and center. Therefore, there is no need to align the detector center perfectly at field center and the setup time is greatly reduced for QA. Conclusion: The high spatial-resolution EPID is proved to be an accurate and efficient dosimetric tool for radiosurgery QA and especially useful in Cyberknife QA for variable aperture collimators.

07 ISOTOPE AND RADIATION SOURCES↗

Infrared Spectroscope for Electron Bunch-length Measurement: Heat Sensor Parameters Analysis

The Linac Coherent Light Source (LCLS) is used for many experiments. Taking advantage of the free electron laser (FEL) process, scientists of various fields perform experiments of all kind. Some for example study protein folding; other experiments are more interested in the way electrons interact with the molecules before they are destroyed. These experiments among many others have very little information about the electrons x-ray produced by the FEL, except that the FEL is using bunches less than 10 femtoseconds long. To be able to interpret the data collected from those experiments, more accurate information is needed about the electron's bunch-length. Existing bunch length measurement techniques are not suitable for the measurement of such small time scales. Hence the need to design a device that will provide more precise information about the electron bunch length. This paper investigates the use of a pyreoelectric heat sensor that has a sensitivity of about 1.34 micro amps per watt for the single cell detector. Such sensitivity, added to the fact that the detector is an array sensor, makes the detector studied the primary candidate to be integrated to an infrared spectrometer designed to better measure the LCLS electron bunch length.

43 PARTICLE ACCELERATORS↗

Carbon monoxide pollution experiment

The experiment is designed to obtain data for the investigation of mechanisms by which CO is removed from the earth's atmosphere. The approach uses an orbiting platform to remotely map global CO concentrations and determine vertical CO profiles using a correlation interferometer measurement technique. The instrument is capable of measuring CO over the range of expected atmospheric burdens and of measuring trace atmospheric constituents.

Bortner, M. H.↗

Ionized dopant concentrations at the heavily doped surface of a silicon solar cell

Data are combined with concentrations obtained by a bulk measurement method using successive layer removal with measurements of Hall effect and resistivity. From the MOS (metal-oxide-semiconductor) measurements it is found that the ionized dopant concentration N has the value (1.4 + or - 0.1) x 10 to the 20th power/cu cm at distances between 100 and 220 nm from the n(+) surface. The bulk measurement technique yields average values of N over layers whose thickness is 2000 nm. Results show that, at the higher concentrations encountered at the n(+) surface, the MOS C-V technique, when combined with a bulk measurement method, can be used to evaluate the effects of materials preparation methodologies on the surface and near surface concentrations of silicon cells.

Weinberg, I.↗

Report of secondary flows, boundary layers, turbulence and wave team, report 1

General criteria for a flight test option are that: (1) there be a good opportunity for comparison with other measurement techniques; (2) the flow to be measured is of considerable scientific or practical interest; and (3) the airborne laser Doppler system is well suited to measure the required quantities. The requirement for comparison, i.e., ground truth, is particularly important because this is the first year of operation for the system. It is necessary to demonstrate that the system does actually measure the winds and compare the results with other methods to provide a check on the system error analysis. The uniqueness of the laser Doppler system precludes any direct comparison, but point measurements from tower mounted wind sensors and two dimensional fields obtained from radars with substantially different sampling volumes are quite useful.

Scoggins, J. R.↗

Microwave Radiometric Studies of Composition and Structure

In the past decade the use of ground-based microwave radiometry has grown as a useful measurement technique. Microwave radiometry is the precise measurement of small amounts of electromagnetic radiation at quite short wavelengths (submillimeter to centimeter). Growth in this field was carefully nutured by the radio astronomy community. Future growth was also discussed.

Olivero, J. J.↗

Microwave radar oceanographic investigations

The Radar Ocean Wave Spectrometer (ROWS) technique was developed and demonstrated for measuring ocean wave directional spectra from air and space platforms. The measurement technique was well demonstrated with data collected in a number of flight experiments involving wave spectral comparisons with wave buoys and the Surface Contour Radar (SCR). Recent missions include the SIR-B underflight experiment (1984), FASINEX (1986), and LEWEX (1987). ROWS related activity is presently concentrating on using the aircraft instrument for wave-processes investigations and obtaining the necessary support (consensus) for a satellite instrument development program. Prospective platforms include EOS and the Canadian RADARSAT.

Jackson, F. C.↗

New estimates of nitrous oxide emissions from biomass burning

The recent discovery of an artifact producing increased levels of N2O in combustion gas samples collected and stored in grab bottles before chemical analysis has resulted in the downgrading of fossil-fuel combustion and the questioning of biomass burning as important sources of N2O. As almost all reported analyses of N2O produced from biomass burning have involved essentially the same collection and analysis protocols as used in the fossil-fuel studies, this source of N2O must also be reexamined. Here, measurements of N2O made over a large prescribed fire using a near real-time in situ measurement technique are reported and compared with measurements of N2O from simultaneously collected grab-bottle samples. The results from 27 small laboratory biomass test fires are also used to help clarify the validity of earlier assessments. It is concluded that biomass burning contributes about seven percent of atmospheric N2O, as opposed to earlier estimates of several times this value.

Cofer, W. R., III↗

Characterization and durability testing of plasma-sprayed zirconia-yttria and hafnia-yttria thermal barrier coatings. Part 1: Effect of spray parameters on the performance of several lots of partially stabilized zirconia-yttria powder

Initial experiments conducted on thermal barrier coatings prepared in the newly upgraded research plasma spray facility and the burner rig test facilities are discussed. Part 1 discusses experiments which establish the spray parameters for three baseline zirconia-yttria coatings. The quality of five similar coating lots was judged primarily by their response to burner rig exposure supplemented by data from other sources such as specimen characterizations and thermal diffusivity measurements. After allowing for burner rig variability, although there appears to be an optimum density (i.e., optimum microstructure) for maximum burner rig life, the distribution tends to be rather broad about the maximum. In Part 2, new hafnia-yttria-based coatings were evaluated against both baseline and alternate zirconia-yttria coatings. The hafnia-yttria coatings and the zirconia-yttria coatings that were prepared by an alternate powder vendor were very sensitive to plasma spray parameters, in that high-quality coatings were only obtained when certain parameters were employed. The reasons for this important observation are not understood. Also not understood is that the first of two replicate specimens sprayed for Part 1 consistently performed better than the second specimen. Subsequent experiments did not display this spray order affect, possibly because a chiller was installed in the torch cooling water circuit. Also, large changes in coating density were observed after switching to a new lot of electrodes. Analyses of these findings were made possible, in part, because of the development of a sensitive density measurement technique described herein in detail. The measured thermal diffusivities did not display the expected strong relationship with porosity. This surprising result was believed to have been caused by increased microcracking of the denser coatings on the stainless steel substrates.

Miller, Robert A.↗

Enhancements in Photon Pressure Measurements Using a Solar Simulator

Initial proof of concept photon momentum measurements were reported at the AIAA Conference in Reno Nevada, January 8-11, 2001. That presentation verified that photon pressure on a simulated solar sail material can be measured under high vacuum conditions using a full spectrum solar simulator and a vacuum compatible force measurement system. Modifications to this test system were implemented to enhance the accuracy of the photon pressure measurement. This paper describes the photon pressure measurement technique and modifications to increase the measurement accuracy using a candidate sail material, aluminized Mylar.

Gray, P. A.↗

Field-Deployable Acoustic Digital Systems for Noise Measurement

Langley Research Center (LaRC) has for years been a leader in field acoustic array measurement technique. Two field-deployable digital measurement systems have been developed to support acoustic research programs at LaRC. For several years, LaRC has used the Digital Acoustic Measurement System (DAMS) for measuring the acoustic noise levels from rotorcraft and tiltrotor aircraft. Recently, a second system called Remote Acquisition and Storage System (RASS) was developed and deployed for the first time in the field along with DAMS system for the Community Noise Flight Test using the NASA LaRC-757 aircraft during April, 2000. The test was performed at Airborne Airport in Wilmington, OH to validate predicted noise reduction benefits from alternative operational procedures. The test matrix was composed of various combinations of altitude, cutback power, and aircraft weight. The DAMS digitizes the acoustic inputs at the microphone site and can be located up to 2000 feet from the van which houses the acquisition, storage and analysis equipment. Digitized data from up to 10 microphones is recorded on a Jaz disk and is analyzed post-test by microcomputer system. The RASS digitizes and stores acoustic inputs at the microphone site that can be located up to three miles from the base station and can compose a 3 mile by 3 mile array of microphones. 16-bit digitized data from the microphones is stored on removable Jaz disk and is transferred through a high speed array to a very large high speed permanent storage device. Up to 30 microphones can be utilized in the array. System control and monitoring is accomplished via Radio Frequency (RF) link. This paper will present a detailed description of both systems, along with acoustic data analysis from both systems.

Shams, Qamar A.↗

Distributed Disdrometer and Rain Gauge Measurement Infrastructure Developed for GPM Ground Validation

Global Precipitation Mission (GPM)retrieval algorithm validation requires datasets characterizing the 4-D structure, variability, and correlation properties of hydrometeor particle size distributions (PSD) and accumulations over satellite fields of view (FOV;<10 km). Collection of this data provides a means to assess retrieval errors related to beam filling and algorithm PSD assumptions. Hence, GPM Ground Validation is developing a deployable network of precipitation gauges and disdrometers to provide fine-scale measurements of PSD and precipitation accumulation variability. These observations will be combined with dual-frequency, polarimetric, and profiling radar data in a bootstrapping fashion to extend validated PSD measurements to a large coverage domain. Accordingly, a total of 24 Parsivel disdrometers(PD), 5 3rd-generation 2D Video Disdrometers (2DVD), 70 tipping bucket rain gauges (TBRG),9 weighing gauges, 7 Hot-Plate precipitation sensors (HP), and 3 Micro Rain Radars (MRR) have been procured. In liquid precipitation the suite of TBRG, PD and 2DVD instruments will quantify a broad spectrum of rain rate and PSD variability at sub-kilometer scales. In the envisioned network configuration 5 2DVDs will act as reference points for 16 collocated PD and TBRG measurements. We find that PD measurements provide similar measures of the rain PSD as observed with collocated 2DVDs (e.g., D0, Nw) for rain rates less than 15 mm/hr. For heavier rain rates we will rely on 2DVDs for PSD information. For snowfall we will combine point-redundant observations of SWER distributed over three or more locations within a FOV. Each location will contain at least one fenced weighing gauge, one HP, two PDs, and a 2DVD. MRRs will also be located at each site to extend the measurement to the column. By collecting SWER measurements using different instrument types that employ different measurement techniques our objective is to separate measurement uncertainty from natural variability in SWER and PSD. As demonstrated using C3VP polarimetric radar, gauge, and 2DVD/PD datasets these measurements can be combined to bootstrap an area wide SWER estimate via constrained modification of density-diameter and radar reflectivity-snowfall relationships. These data will be combined with snowpack, airborne microphysics, radar, radiometer, and tropospheric sounding data to refine GPM snowfall retrievals. The gauge and disdrometer instruments are being developed to operate autonomously when necessary using solar power and wireless communications. These systems will be deployed in numerous field campaigns through 2016. Planned deployment of these systems include field campaigns in Finland (2010), Oklahoma (2011), Canada (2012) and North Carolina (2013). GPM will also deploy 20 pairs of TBRGs within a 25 km2 region along the Virginia coast under NASA NPOL radar coverage in order to quantify errors in point-area rainfall measurements.

Petersen, Walter A.↗

Blade Displacement Measurements of the Full-Scale UH-60A Airloads Rotor

Blade displacement measurements were acquired during a wind tunnel test of the full-scale UH-60A Airloads rotor. The test was conducted in the 40- by 80-Foot Wind Tunnel of the National Full-Scale Aerodynamics Complex at NASA Ames Research Center. Multi-camera photogrammetry was used to measure the blade displacements of the four-bladed rotor. These measurements encompass a range of test conditions that include advance ratios from 0.15 to unique slowed-rotor simulations as high as 1.0, thrust coefficient to rotor solidity ratios from 0.01 to 0.13, and rotor shaft angles from -10.0 to 8.0 degrees. The objective of these measurements is to provide a benchmark blade displacement database to be utilized in the development and validation of rotorcraft computational tools. The methodology, system development, measurement techniques, and preliminary sample blade displacement measurements are presented.

Barrows, Danny A.↗

The Atmosphere-Space Transition Region Explorer (ASTRE) – A Low Perigee Satellite to Investigate the Coupling of the Earth’s Upper Atmosphere and Magnetosphere

The Atmosphere-Space Transition Region Explorer (ASTRE) is a mission concept designed to carry out an unprecedented study of the interaction between the Earth’s atmosphere and the ionized gases of space within the atmosphere-space transition region. By gathering direct measurements of the coupling of ion and neutral gases in this region, ASTRE provides the critical missing link in our knowledge of the transfer, dissipation, and regulation of energy and momentum between the sun and the upper atmosphere. ASTRE provides the first detailed, systematic investigation of this important unexplored region, vastly improves and constrains models of the upper atmosphere, and fills a critical gap in our understanding of how the coupled lower ionosphere/upper atmosphere “works” as a system. To achieve its science objectives, ASTRE gathers accurate measurements of plasma and neutral gases, electric and magnetic fields, and energetic particles using well-proven, in situ instruments with excellent flight heritage. Furthermore, as described herein, all the instruments have been designed to perform well in the low perigee environment, including altitudes of 150 km and lower. ASTRE utilizes a three-axis stabilized satellite that uses on-board propulsion to carry out systematic, low perigee measurements at high latitudes. The satellite design incorporates a “form follows function” approach with a cylindrical shape and conductive body-mounted solar arrays to minimize drag and perturbations to the space environment. Atomic-oxygen resistant materials are utilized and a passive thermal design with heat pipes and radiator panels minimizes the impact of aero-heating. ASTRE launches into a 250 km × 1500 km elliptical insertion orbit with an inclination of 83°. Perigee precesses from its highest northern latitude to its highest southern latitude every ~60 days. Hydrazine propulsion provides over 2000 orbits with perigee below 200 km, with a significant fraction as low as 150 km, during high latitude, two-week campaigns when perigee precesses to either the northern or southern high latitude region. At mid and low latitudes, the perigee is near 225 km. Because very conservative assumptions were made with respect to the orbital analysis and drag, including continuous 3-sigma “worst-case” solar flux and atmospheric density, when additional propellant is included (accommodated in the current design) and some of the stringent assumptions are relaxed, the ASTRE mission described herein may be expected to include repeated excursions to altitudes of ~130 km or even lower. This paper presents an overview of the ASTRE mission, its science motivation, and objectives. It includes a discussion of the science-driven requirements and traceability, followed by a “proof-of concept” implementation that includes notional instruments and a straightforward spacecraft design. Three key points are demonstrated: 1) There is a critical knowledge gap in the high latitude, atmosphere-space transition region below 250 km; 2) The instrument and measurement techniques needed to obtain the ASTRE measurements are well-proven and function well in the low-altitude environment; and 3) A mature spacecraft design, flight dynamics analysis, and concept of operations have been developed that demonstrate that the ASTRE mission can be achieved in a straightforward manner using current technologies.

Ionosphere↗