Search NASA⌕ Search

SEARCH · Search NASA

Results for “Novel Characterization Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Co-flow injection for serial crystallography at X-ray free-electron lasers

Serial femtosecond crystallography (SFX) is a powerful technique that exploits X-ray free-electron lasers to determine the structure of macromolecules at room temperature. Despite the impressive exposition of structural details with this novel crystallographic approach, the methods currently available to introduce crystals into the path of the X-ray beam sometimes exhibit serious drawbacks. Samples requiring liquid injection of crystal slurries consume large quantities of crystals (at times up to a gram of protein per data set), may not be compatible with vacuum configurations on beamlines or provide a high background due to additional sheathing liquids present during the injection. Proposed and characterized here is the use of an immiscible inert oil phase to supplement the flow of sample in a hybrid microfluidic 3D-printed co-flow device. Co-flow generation is reported with sample and oil phases flowing in parallel, resulting in stable injection conditions for two different resin materials experimentally. A numerical model is presented that adequately predicts these flow-rate conditions. The co-flow generating devices reduce crystal clogging effects, have the potential to conserve protein crystal samples up to 95% and will allow degradation-free light-induced time-resolved SFX.

3D printing↗

SU-F-J-142: Proposed Method to Broaden Inclusion Potential of Patients Able to Use the Calypso Tracking System in Prostate Radiotherapy

Purpose: To introduce a non-standard method of patient setup, using BellyBoard immobilization, to better utilize the localization and tracking potential of an RF-beacon system with EBRT for prostate cancer. Methods: An RF-beacon phantom was imaged using a wide bore CT scanner, both in a standard level position and with a known rotation (4° pitch and 7.5° yaw). A commercial treatment planning system (TPS) was used to determine positional coordinates of each beacon, and the centroid of the three beacons for both setups. For each setup at the Linac, kV AP and Rt Lateral images were obtained. A full characterization of the RF-beacon system in clinical mode was completed for various beacons’ array-to-centroid distances, which includes vertical, lateral, and longitudinal offset data, as well as pitch and yaw offset measurements for the tilted phantom. For the single patient who has been setup using the proposed BellyBoard method, a supine simulation was first obtained. When abdominal protrusion was found to be exceeding the limits of the RF-Beacon system through distance-based analysis in the TPS, the patient is re-simulated prone with the BellyBoard. Array to centroid distance is measured again in the TPS, and if found to be within the localization or tracking region it is applied. Results: Characterization of limitations for the RF-beacon system in clinical mode showed acceptable consistency of offset determination for phantom setup accuracy. The nonstandard patient setup method reduced the beacons’ centroid-to-array distance by 8.32cm, from 25.13cm to 16.81cm; completely out of tracking range (greater than 20cm) to within setup tracking range (less than 20cm). Conclusion: Using the RF-beacon system in combination with this novel patient setup can allow patients who would otherwise not be candidates for beacon enhanced EBRT to now be able to benefit from the reduced PTV margins of this treatment method.

60 APPLIED LIFE SCIENCES↗

Improving Ni-Based SOFC Anode Resilience and Durability through Secondary Phase Formation

The project used a multi-disciplinary approach to test test if 2° materials, added to traditional cermet components, enhanced SOFC mechanical strength, anode resilience and durability when subjected to electrochemical and environmental redox cycling. Findings from fracture testing, electrochemical studies and operando Raman spectroscopy measurements demonstrated that aluminum titanate (Al 2 TiO 5 or ALT) mechanically mixed with NiO-YSZ cermets confers superior mechanical strength and slower degradation rates under polarization. No deleterious effects from ALT in conversion efficiency were observed. Specific accomplishments included the following: (1) Refined methods used to fabricate ALT enhanced anodes into bi-layer anode supports to achieve high power densities; (2) Compared the effects of adding ALT mechanically to Ni-YSZ powders prior to anode fabrication with adding ALT through infiltration and co-infiltration of YSZ scaffolds; (3) Tested the resilience of these novel materials to electrochemical and environmental redox cycling and thermal stresses commonly encountered in functioning SOFCs; and (4) Characterized the ability of ALT to improve the carbon tolerance of Ni-YSZ anodes operating with dry methane.

01 COAL, LIGNITE, AND PEAT↗

Fueling up with Hydrogen: New Approaches to Hydrogen Storage (433rd Brookhaven Lecture)

Hydrogen, the most abundant element in the universe, burns excellently and cleanly, with only pure water as a byproduct. NASA has used hydrogen as fuel for years in the space program. So, why not use hydrogen to fuel cars? The bottleneck of developing hydrogen-fueled vehicles has been identified: the greatest problem is storage. The conventional storage method, compressed hydrogen gas, requires a large tank volume, and the possibility of a tank rupture poses a significant safety risk. Another method, low temperature liquid storage, is expensive and impractical for most automotive applications. An alternative is to store the hydrogen in the solid state. In his talk, Jason Graetz will describe the new approaches to hydrogen storage being studied by his group at BNL. These include using kinetically stabilized hydrides, bialkali alanates and reversible metal-organic hydrides. The researchers are also using novel synthesis approaches, state-of-the-art characterization and first principles modeling, all providing a better fundamental understanding of these interesting and useful new materials.

08 HYDROGEN↗

A Passive System Reliability Analysis for a Station Blackout

The latest iterations of advanced reactor designs have included increased reliance on passive safety systems to maintain plant integrity during unplanned sequences. While these systems are advantageous in reducing the reliance on human intervention and availability of power, the phenomenological foundations on which these systems are built require a novel approach to a reliability assessment. Passive systems possess the unique ability to fail functionally without failing physically, a result of their explicit dependency on existing boundary conditions that drive their operating mode and capacity. Argonne National Laboratory is performing ongoing analyses that demonstrate various methodologies for the characterization of passive system reliability within a probabilistic framework. Two reliability analysis techniques are utilized in this work. The first approach, the Reliability Method for Passive Systems, provides a mechanistic technique employing deterministic models and conventional static event trees. The second approach, a simulation-based technique, utilizes discrete dynamic event trees to treat time- dependent phenomena during scenario evolution. For this demonstration analysis, both reliability assessment techniques are used to analyze an extended station blackout in a pool-type sodium fast reactor (SFR) coupled with a reactor cavity cooling system (RCCS). This work demonstrates the entire process of a passive system reliability analysis, including identification of important parameters and failure metrics, treatment of uncertainties and analysis of results.

Brunett, Acacia↗

A novel approach to correct the coded aperture misalignment for fast neutron imaging

Aperture alignment is crucial for the diagnosis of neutron imaging because it has significant impact on the coding imaging and the understanding of the neutron source. In our previous studies on the neutron imaging system with coded aperture for large field of view, “residual watermark,” certain extra information that overlies reconstructed image and has nothing to do with the source is discovered if the peak normalization is employed in genetic algorithms (GA) to reconstruct the source image. Some studies on basic properties of residual watermark indicate that the residual watermark can characterize coded aperture and can thus be used to determine the location of coded aperture relative to the system axis. In this paper, we have further analyzed the essential conditions for the existence of residual watermark and the requirements of the reconstruction algorithm for the emergence of residual watermark. A gamma coded imaging experiment has been performed to verify the existence of residual watermark. Based on the residual watermark, a correction method for the aperture misalignment has been studied. A multiple linear regression model of the position of coded aperture axis, the position of residual watermark center, and the gray barycenter of neutron source with twenty training samples has been set up. Using the regression model and verification samples, we have found the position of the coded aperture axis relative to the system axis with an accuracy of approximately 20 μm. Conclusively, a novel approach has been established to correct the coded aperture misalignment for fast neutron coded imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generalizing synthetic data-trained acoustic predictive models to real-world measurements

Acoustic Resonance Spectroscopy (ARS) is highly sensitive to structural properties such as material, geometry, and environmental conditions; as a consequence, it can noninvasively measure internal properties that are unobservable by most other methods. Because of its sensing capabilities and low implementation cost and complexity, ARS has potential as a paradigm shift in noninvasive sensing, characterization, and monitoring applications. However, extracting specific properties from ARS measurements, comprising the vibration spectrum of a test object, is challenging due to the sensitivity of the spectra to other structural changes not being measured, e.g. manufacturing tolerances, component coupling, environmental variation, etc. Neural Networks are promising tools for identifying trends in ARS measurements, but their training typically requires large datasets, which are often impractical to obtain for real-world systems. Synthetic data can be simulated efficiently, but discrepancies between synthetic and real-world data frequently lead to poor generalization when testing on the real-world data. We propose a novel ARS model training framework that enables networks trained exclusively on synthetic ARS data to generalize effectively to real-world measurements. Our approach leverages the Correlation Alignment (CORAL) technique to enforce the extraction of features common to both synthetic and real-world domains. As a case study, we demonstrate noninvasive ARS-based pressure measurements in sealed systems. Finite element method (FEM) simulations were used to generate synthetic training data across diverse vessel configurations and pressure conditions, and model performance was then tested on real-world measurements. We demonstrate that robust machine learning models for ARS can be developed without large real-world datasets, significantly broadening the applicability of ARS for noninvasive sensing. Moreover, the approach is extensible to other sensing modalities where synthetic data are abundant but real-world data are limited.

36 MATERIALS SCIENCE↗

Physical and psychophysical characterization of a novel clinical system for digital mammography

Purpose: In recent years, many approaches have been investigated on the development of full-field digital mammography detectors and implemented in practical clinical systems. Some of the most promising techniques are based on flat panel detectors, which, depending on the mechanism involved in the x-ray detection, can be grouped into direct and indirect flat panels. Direct detectors display a better spatial resolution due to the direct conversion of x rays into electron-hole pairs, which do not need an intermediate production of visible light. In these detectors the readout is usually achieved through arrays of thin film transistors (TFTs). However, TFT readout tends to display noise characteristics worse than those from indirect detectors. To address this problem, a novel clinical system for digital mammography has been recently marketed based on direct-conversion detector and optical readout. This unit, named AMULET and manufactured by FUJIFILM, is based on a dual layer of amorphous selenium that acts both as a converter of x rays (first layer) and as an optical switch for the readout of signals (second layer) powered by a line light source. The optical readout is expected to improve the noise characteristics of the detector. The aim is to obtain images with high resolution and low noise, thanks to the combination of optical switching technology and direct conversion with amorphous selenium. In this article, the authors present a characterization of an AMULET system. Methods: The characterization was achieved in terms of physical figures as modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE), and contrast-detail analysis. The clinical unit was tested by exposing it to two different beams: 28 kV Mo/Mo (namely, RQA-M2) and 28 kV W/Rh (namely, W/Rh). Results: MTF values of the system are slightly worse than those recorded from other direct-conversion flat panels but still within the range of those from indirect flat panels: The MTF values of the AMULET system are about 45% and 15% at 5 and 8 lp/mm, respectively. On the other hand, however, AMULET NNPS results are consistently better than those from direct-conversion flat panels (up to two to three times lower) and flat panels based on scintillation phosphors. DQE results lie around 70% when RQA-M2 beams are used and approaches 80% in the case of W/Rh beams. Contrast-detail analysis, when performed by human observers on the AMULET system, results in values better than those published for other full-field digital mammography systems. Conclusions: The novel clinical unit based on direct-conversion detector and optical reading presents great results in terms of both physical and psychophysical characterizations. The good spatial resolution, combined with excellent noise properties, allows the achievement of very good DQE, better than those published for clinical FFDM systems. The psychophysical analysis confirms the excellent behavior of the AMULET unit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atmospheric solids analysis probe mass spectrometry for the rapid identification of pollens and semi-quantification of flavonoid fingerprints

From allergies to plant reproduction, pollens have important impacts on the health of human and plant populations, yet identification of pollen grains remains difficult and time-consuming. Low-volatility flavonoids generated from pollens cannot be easily characterized and quantified with current analytical techniques. Here we demonstrate the novel use of atmospheric solids analysis probe mass spectrometry (ASAP-MS) for the characterization of flavonoids in pollens. Flavonoid patterns were generated for pollens collected from different plant types (trees and bushes) in addition to bee pollens from distinct geographic regions. Standard flavonoids (kaempferol and rhamnazin) and those produced from pollens were compared and assessed with ASAP-MS using low-energy collision MS/MS. Results for a semi-quantitative method for assessing the amount of a flavonoid in pollens are also presented.

59 BASIC BIOLOGICAL SCIENCES↗

Reimagining metal-organic framework discovery: Integrating experiment, computation, and artificial intelligence

The traditional development of novel metal–organic frameworks (MOFs) is often hindered by challenges such as synthetic accessibility and time- and resource-intensive experimentation. High-throughput, automated experimental and computational techniques have enabled rapid chemical space exploration and theoretical MOF design. When combined with artificial intelligence (AI), these methods can be used to lead autonomous laboratories to new frontiers for MOF discovery, where these materials can be designed for a specific application, efficiently synthesized, characterized, and evaluated. Here, this perspective highlights the role of AI in advancing automated MOF synthesis and characterization, computational MOF design and screening, and the integration of these approaches within autonomous workflows to ultimately enable the MOF laboratories of the future.

Gaidimas, Madeleine A. [Northwestern University, E↗

Controlled synthesis of three-dimensional hierarchical Bi{sub 2}WO{sub 6} microspheres with optimum photocatalytic activity

Highlights: Black-Right-Pointing-Pointer The synthesized method is very simple. It can be widely used in the production. Black-Right-Pointing-Pointer The morphology is novel and the property is fine. Black-Right-Pointing-Pointer The formation of 3D hierarchical microsphere can be induced by changing the concentration of KNO{sub 3}. -- Abstract: Three-dimensional (3D) hierarchical Bi{sub 2}WO{sub 6} microsphere and octahedral Bi{sub 2}WO{sub 6} have been synthesized by a facile hydrothermal method using KNO{sub 3} solution and distilled water as solvent, respectively. The obtained products were characterized by X-ray diffraction, scanning electron microscopy, N{sub 2} adsorption/desorption, and UV-vis diffuse reflectance spectroscopy in detail. The concentration of KNO{sub 3} played a key role in the formation of 3D hierarchical Bi{sub 2}WO{sub 6} microspheres. A possible formation mechanism of Bi{sub 2}WO{sub 6} microsphere was proposed. The photocatalytic activity of the as-synthesized products was evaluated by monitoring the degradation of MB solution under sunlight irradiation. It was found that the photocatalytic activity of the 3D hierarchical Bi{sub 2}WO{sub 6} microsphere was superior to the octahedral Bi{sub 2}WO{sub 6}, which was attributed to the larger surface area and special hierarchical structure of Bi{sub 2}WO{sub 6} microsphere.

36 MATERIALS SCIENCE↗

A novel generalized metal dissolution approach for the synthesis of mixed valent mesoporous metal oxides

A novel approach is introduced to synthesize multivalent, mesoporous metal oxides with high surface area using zero oxidation state precursors. In this paper, the synthesis and comprehensive characterization of the metal oxides of s block, p block, transition metal, and lanthanide series elements are reported. Some of the synthesized metal oxides showed mixed phases at relatively low temperatures which is advantageous over single-phase materials. The initial metal dissolution process allows this method to be extended to any metal in the periodic table and metal alloys. A green and highly efficient catalytic sp 2 -sp 2 C–C coupling reaction is carried out using high surface area MoO3 (142 m 2 /g) where complete conversion is observed within one hour.

36 MATERIALS SCIENCE↗

Contrast-to-noise ratio optimization for a prototype phase-contrast computed tomography scanner

In the field of biomedical X-ray imaging, novel techniques, such as phase-contrast and dark-field imaging, have the potential to enhance the contrast and provide complementary structural information about a specimen. In this paper, a first prototype of a preclinical X-ray phase-contrast CT scanner based on a Talbot-Lau interferometer is characterized. We present a study of the contrast-to-noise ratios for attenuation and phase-contrast images acquired with the prototype scanner. The shown results are based on a series of projection images and tomographic data sets of a plastic phantom in phase and attenuation-contrast recorded with varying acquisition settings. Subsequently, the signal and noise distribution of different regions in the phantom were determined. We present a novel method for estimation of contrast-to-noise ratios for projection images based on the cylindrical geometry of the phantom. Analytical functions, representing the expected signal in phase and attenuation-contrast for a circular object, are fitted to individual line profiles of the projection data. The free parameter of the fit function is used to estimate the contrast and the goodness of the fit is determined to assess the noise in the respective signal. The results depict the dependence of the contrast-to-noise ratios on the applied source voltages, the number of steps of the phase stepping routine, and the exposure times for an individual step. Moreover, the influence of the number of projection angles on the image quality of CT slices is investigated. Finally, the implications for future imaging purposes with the scanner are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multilayer Laue lens : a path toward one nanometer x-ray focusing.

The multilayer Laue lens (MLL) is a novel diffractive optic for hard X-ray nanofocusing, which is fabricated by thin film deposition techniques and takes advantage of the dynamical diffraction effect to achieve a high numerical aperture and efficiency. It overcomes two difficulties encountered in diffractive optics fabrication for focusing hard X-rays: (1) small outmost zone width and (2) high aspect ratio. Here, we will give a review on types, modeling approaches, properties, fabrication, and characterization methods of MLL optics. We show that a full-wave dynamical diffraction theory has been developed to describe the dynamical diffraction property of the MLL and has been employed to design the optimal shapes for nanofocusing. We also show a 16 nm line focus obtained by a partial MLL and several characterization methods. Experimental results show a good agreement with the theoretical calculations. With the continuing development of MLL optics, we believe that an MLL-based hard x-ray microscope with true nanometer resolution is on the horizon.

47 OTHER INSTRUMENTATION↗

Development of a characterization methodology for post-irradiation examination of miniature fuel specimens

The miniature fuel (MiniFuel) irradiation experimental design at Oak Ridge National Laboratory (ORNL) enables benchmark testing and separate effects testing of novel fuel types in the High Flux Isotope Reactor (HFIR) in support of the Advanced Fuels Campaign (AFC). The first round of MiniFuel sub-capsules will be available for post-irradiation examination at the end of 2018. This report establishes the procedure for disassembly, fuel retrieval, post-irradiation analysis of the fission product behavior (fission gas release and fuel swelling), and microstructural characterization of the irradiated MiniFuel specimens. All methods were tested and validated out-of-cell and are ready to be implemented in-cell for use on the first set of irradiated MiniFuel specimens. The path forward regarding further characterization techniques is presented, which will involve analyzing other specimen geometries using the methods presented in this report and expanding the post-irradiation analysis of MiniFuel specimens to include additional properties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advances in Computational Approaches for Estimating Passive Permeability in Drug Discovery

Passive permeation of cellular membranes is a key feature of many therapeutics. The relevance of passive permeability spans all biological systems as they all employ biomembranes for compartmentalization. A variety of computational techniques are currently utilized and under active development to facilitate the characterization of passive permeability. These methods include lipophilicity relations, molecular dynamics simulations, and machine learning, which vary in accuracy, complexity, and computational cost. This review briefly introduces the underlying theories, such as the prominent inhomogeneous solubility diffusion model, and covers a number of recent applications. Various machine-learning applications, which have demonstrated good potential for high-volume, data-driven permeability predictions, are also discussed. Due to the confluence of novel computational methods and next-generation exascale computers, we anticipate an exciting future for computationally driven permeability predictions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interferometric Characterization of the Earth's Atmosphere from Lagrange Point 2

Part of the NASA plans for future Earth Science missions calls for observations using novel vantage points that can produce science products otherwise unobtainable. Observations of the Earth from the Lagrange-2 point, L-2, (1.5 million km behind the Earth on the Earth-Sun line) affords a unique vantage point for atmospheric science. Spectral observation of the Earth's atmosphere using solar occultation techniques in the near infrared (1 to 4 microns) provides one of the most accurate methods of passively sensing attitude profiles of the major species (CO2, O3, O2, CH4, H2O N2O). While traditional polar orbiting occultation measurements can obtain about 14 measurements per day (2 per orbit), solar occultation observations from the Lagrange-2 point will yield hourly profile measurements at all latitudes. The expected spatial resolution is 2 km in altitude, 0.5 degrees in latitude, and 2 degrees in longitude. The result from 24 hours of observations will be a three-dimensional map of atmospheric composition. To accomplish this task from L-2 requires the development of a large moderate spectral resolution instrument whose entrance aperture is about 10 meters. Use of a standard telescope design with a 10-meter circular mirror or a 10-meter strip mirror would be prohibitively expensive and excessively massive. Instead, we are proposing the development of a 10-meter linear interferometer coupled to a Fourier transform imaging spectrometer. The result will be a highly efficient design with sufficient sensitivity, while having both spatial and spectral resolution to produce the desired results. Preliminary calculations show that seven species (CO2, O3, O2, CH4, H2O N2O) have clearly separated spectral features in the I to 4 microns range with sufficient absorption to produce profile information from near the Earth's surface to the middle stratosphere. For CO2 the estimated sensitivity to change is 0.33% or 1 part in 330. This should be sufficient to detect changes that are significant for the carbon cycle studies. Initial instrument design studies are underway to determine the optimum optical design for the interferometer-spectrometer as well as the necessary highly stable mechanical designs. Separate design studies are being conducted for the spacecraft. shuttle launch facility, low-light solar power design, thermal control, and unique navigation requirements to reach and maintain the tight halo orbit about L-2.

Herman, Jay R.↗

Flexible, cluster-based analysis of the electronic medical record of sepsis with composite mixture models

The widespread adoption of electronic medical records (EMRs) in healthcare has provided vast new amounts of data for statistical machine learning researchers in their efforts to model and predict patient health status, potentially enabling novel advances in treatment. In the case of sepsis, a debilitating, dysregulated host response to infection, extracting subtle, uncataloged clinical phenotypes from the EMR with statistical machine learning methods has the potential to impact patient diagnosis and treatment early in the course of their hospitalization. However, there are significant barriers that must be overcome to extract these insights from EMR data. First, EMR datasets consist of both static and dynamic observations of discrete and continuous-valued variables, many of which may be missing, precluding the application of standard multivariate analysis techniques. Second, clinical populations observed via EMRs and relevant to the study and management of conditions like sepsis are often heterogeneous; properly accounting for this heterogeneity is critical. Here, we describe an unsupervised, probabilistic framework called a composite mixture model that can simultaneously accommodate the wide variety of observations frequently observed in EMR datasets, characterize heterogeneous clinical populations, and handle missing observations. In conclusion, we demonstrate the efficacy of our approach on a large-scale sepsis cohort, developing novel techniques built on our model-based clusters to track patient mortality risk over time and identify physiological trends and distinct subgroups of the dataset associated with elevated risk of mortality during hospitalization.

59 BASIC BIOLOGICAL SCIENCES↗