Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Investigation of the 244 Pu ⁢( 48 Ca,𝑥⁢𝑛) 292−𝑥 Fl reaction with the LBNL SHREC detector: Investigation of decay chains of isotopes of flerovium (𝑍=114)

The 244 Pu ⁢( 48 Ca,𝑥⁢𝑛)⁢ 292−𝑥 Fl reaction was investigated at Lawrence Berkeley National Laboratory’s 88 Inch Cyclotron using the Berkeley Gas-filled Separator (BGS), the newly installed Superheavy Recoil detector, along with an upgraded digital electronics and data acquisition system. Seven decay chains were observed starting with an evaporation residue, followed by a single 𝛼 decay and a spontaneous fission. The decay characteristics of these seven decay chains led to an assignment to 288 Fl , the product of the 4⁢𝑛 reaction channel. Two additional chains were (tentatively) assigned to the decay of the 3⁢𝑛 exit channel, 289 Fl . Cross sections for the 4⁢𝑛 and 3⁢𝑛 exit channels were 𝜎 prod =6.7⁢($^{36}_{25}$) pb and 𝜎 prod =1.6⁢($^{22}_{11}$) pb, respectively. Another decay chain, tentatively assigned to the 5⁢𝑛 exit channel through the 48 Ca + 244 Pu reaction or the 3⁢𝑛 exit channel of the 48 Ca + 242 Pu reaction, was also detected. Detailed information regarding the observed decay chains and their nuclear structure aspects is discussed, along with the performance of the BGS and the new detection system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the convergence of the fixed point method for solving neutron transport alpha eigenvalue problems

It was shown that the Fixed Point Method (also known as the Rayleigh Quotient Method) is several times faster than the Critical Search Method for solving neutron transport alpha eigenvalue problems. It was also shown that the Fixed Point Method is able to determine the alpha eigenvalues of sub-critical systems that are beyond the reach of the Critical Search Method. Despite these significant advances, the Fixed Point Method remains an unproven algorithm. Here, this report provides a proof.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extension of the Dytlewski-style dead time correction formalism for neutron multiplicity counting to any order

Here, neutron multiplicity counting using shift-register calculus is an established technique in the science of international nuclear safeguards for the identification, verification, and assay of special nuclear materials. Typically passive counting is used for Pu and mixed Pu-U items and active methods are used for U materials. Three measured counting rates, singles, doubles and triples are measured and, in combination with a simple analytical point-model, are used to calculate characteristics of the measurement item in terms of known detector and nuclear parameters. However, the measurement problem usually involves more than three quantities of interest, but even in cases where the next higher order count rate, quads, is statistically viable, it is not quantitatively applied because corrections for dead time losses are currently not available in the predominant analysis paradigm. In this work we overcome this limitation by extending the commonly used dead time correction method, developed by Dytlewski, to quads. We also give results for pents, which may be of interest for certain special investigations. Extension to still higher orders, may be accomplished by inspection based on the sequence presented. We discuss the foundations of the Dytlewski method, give limiting cases, and highlight the opportunities and implications that these new results expose. In particular there exist a number of ways in which the new results may be combined with other approaches to extract the correlated rates, and this leads to various practical implementations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deuterated stilbene (stilbene-d 12 ): An improved detector for fast neutrons

Here, we have developed and evaluated two prototype fast neutron deuterated-stilbene scintillators. The largest scintillator is hexagonal in shape with volume 32 cm 3 , comprised of deuterated crystalline trans-stilbene (stilbene-d 12 ). These samples were grown using a solution-based crystal growing method developed at Lawrence Livermore Laboratory to grow conventional 1 H-based stilbene scintillator crystals. The stilbene-d 12 prototype detectors show excellent neutron/gamma discrimination, noticeably better than 1 H-stilbene, and appear to have less asymmetry in the response to neutrons incident from different directions. Finally, like other deuterated scintillators, the stilbene-d 12 detectors in many applications can provide incident neutron energy spectra, without time of flight, by suitably unfolding the neutron light-output spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beirut Explosion Yield and Mushroom Cloud Height - Effects of the Source Environment

I use crater dimensions to estimate the yield of the August 4th, 2020 Beirut explosion to be equivalent to approximately 1.4 kilotons of TNT with a lower bound of about 0.7 kilotons. Based on the amount of ammonium nitrate reported to have been stored at the Beirut harbor, I assume an upper bound for the yield of 2.75 kilotons. However, it is highly likely that the yield was less than 2.75 kilotons, since reported values for TNT equivalence of ammonium nitrate are typically much less than one hundred percent. The crater-size based yield estimates are based on crater radius estimates from satellite imagery and empirical curves and data for scaled crater radius from past chemical and nuclear explosions. I present evidence that suggests that the relatively large crater radius is due to a high degree of coupling of shock wave energy to the surrounding medium and a reduction of the effective stress because of a high level of saturation of the geologic media beneath the explosion. I provide yield estimates based on seismic body-wave magnitude and crater depth as corroborating evidence. I compare preliminary estimates for the maximum debris cloud height, based on cell phone videos/images, with predicted maximum heights for this yield range from empirical formulas and numerical cloud-rise models. Based on a preliminary analysis of cell phone footage, the observed maximum cloud height appears to be approximately 1600 m. This is much lower than that predicted using standard empirical formulas and buoyant cloud rise models. I present results from a modified buoyant cloud rise model that more accurately predicts the maximum cloud height by allowing for the inclusion of a fixed amount of air and/or water into the fireball at the start of cloud rise. The amount of mass that needs to be added at the start, to reproduce the observed maximum cloud height, is relatively small compared to the total mass entrained during cloud rise. A much greater amount of dry air or debris is required, relative to water, for an equivalent reduction in maximum cloud height. The ammonium nitrate is one possible source for water in the fireball since it was being stored in a very humid environment and ammonium nitrate is known to be hygroscopic. The ground beneath the explosion, especially if it were saturated, and the nearby harbor could also have been sources for water or debris in the fireball.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

FY25 Mid-Year Report: FNCL Enhancements Implementation

During the first half of FY25 the FNCL team has made consistent progress toward the completion of our project goals. The FNCL prototype panel design has been successfully applied to a fully instrumented 3-panel system which is actively under construction. The FNCL Demonstrator System contains solid scintillators instrumented with SiPMs, which operate on an updated CAEN digitizer, requires no high-voltage, and has a smaller overall footprint. The onboard software will include the LLNL-developed GMM-PSD signal processing. Later this year the system will be experimentally tested alongside the baseline FNCL instrument at LLNLs ISSA facility. In addition to a full systems test, the performance of a DD generator for active interrogation measurements compared to the standard AmLi source will be established for both systems. The data collected at the ISSA facility will be used to experimentally validate the FNCL-Fast Isotopic Fuel Assay’s (FIFA) capability to measure U-235 loading and to predict gadolinium poison content with passive interrogation. The FNCL-FIFA modal was benchmarked with simulation-based data and a user-friendly GUI was added earlier this year. Three separate codes have been submitted to the LLNL ESW system for review prior to their transfers. These include the Predictive Modeling Response toolkit, GMM-PSD firmware beta version, and the FNCL-FIFA analysis package with GUI and user documentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Replacement of a Photomultiplier Tube with Silicon Photomultipliers for use in Safeguards Applications

We compared the performance of a SiPM array and a PMT in a laboratory setting using a single 5.08x5.08-cm cylindrical sodium iodide scintillating crystal. Photomultiplier tubes (PMTs) are the most commonly used device to monitor scintillating materials for radiation detection purposes. The systems are sometimes limited by disadvantages in the PMTs that may degrade their performance, including temperature dependence and variation with magnetic field. Instrumentation engineering must also contend with a potentially large volume relative to the active scintillator volume, fragility, and high voltage requirements. One possible alternative is an array of silicon photomultipliers (SiPMs). Measurements were made with a 5.04x5.04-cm sensL J-series SiPM array and a 7.62cm Hamamatsu PMT. We demonstrated how the SiPM bias can be sufficiently altered to remove the effects of temperature variation encountered in environments where nuclear safeguards work is often performed. Finally, we evaluated a method of determining enrichment levels of 235 U at various levels and shielding configurations, using both the PMT-mounted and SiPM-mounted scintillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗