Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Benchmark Evaluation of Dounreay Prototype Fast Reactor Minor Actinide Depletion Measurements

Historic measurements of actinide samples in the Dounreay Prototype Fast Reactor (PFR) are of interest for modern nuclear data and simulation validation. Samples of various higher-actinide isotopes were irradiated for 492 effective full-power days and radiochemically assayed at Oak Ridge National Laboratory (ORNL) and Japan Atomic Energy Research Institute (JAERI). Limited data were available regarding the PFR irradiation; a six-group neutron spectra was available with some power history data to support a burnup depletion analysis validation study. Under the guidance of the Organisation for Economic Co-Operation and Development Nuclear Energy Agency (OECD NEA), the International Reactor Physics Experiment Evaluation Project (IRPhEP) and Spent Fuel Isotopic Composition (SFCOMPO) Project are collaborating to recover all measurement data pertaining to these measurements, including collaboration with the United Kingdom to obtain pertinent reactor physics design and operational history data. These activities will produce internationally peer-reviewed benchmark data to support validation of minor actinide cross section data and modern neutronic simulation of fast reactors with accompanying fuel cycle activities such as transportation, recycling, storage, and criticality safety.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantification of the 35 Cl($\textit{n, p}$) reaction channel

The evaluated 35 Cl($\textit{n, p}$) cross sections in the ENDF/B-VIII.0 nuclear data library remain uncertain because of the lack of measured data in the neutron energy range between 100-600 keV. In this energy region, the R-matrix analysis relies heavily on estimated ($\textit{n, p}$) partial widths and level density information. This resulted in significant differences of the evaluated cross sections and predicted reactivity in nuclear reactor applications with respect to previous nuclear data libraries. Here, we present a methodology to quantify the cross sections for the 35 Cl($\textit{n, p}$) reaction channel from the combination of measured total cross sections and model calculations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Selection of a Pair of Experiments to Optimally Reduce Uncertainty in Targeted Nuclear Data

We propose a novel process to select a pair of differential and integral experiments that best reduce uncertainties in targeted 239 ⁢Pu nuclear data while compressing the current nuclear data pipeline from 20 to 3 years. 239⁢ Pu nuclear data are poorly understood for neutrons in the intermediate energy range due to sparsity and uncertainty in historical experiments. New experiments targeting this range will enable better understanding of these nuclear data, but choosing the ideal experiments to conduct is challenging. Beginning with a prior distribution represented by samples of nuclear data generated from theory, generalized least squares adjustments are made to incorporate data from historical experiments. To quantify potential uncertainty reduction obtainable from a pair of candidate experiments, we compute the D-optimality criterion of the posterior covariance of intermediate energy range nuclear data compared to the equivalent covariance after additional adjustment to the pair of candidate experiments. Repeating the process for each of many candidate pairs facilitates the final selection. Results support 63⁢ Cu total cross section measurements for differential experiments and alumina and alumina/graphite configurations for integral experiments. This analysis enables choosing differential and integral experiments to be executed concurrently while shortening decision times relative to the current nuclear data pipeline.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Underground Test Area Project of the Nevada Test Site: Building Confidence in Groundwater Flow and Transport Models at Pahute Mesa Through Focused Characterization Studies

Pahute Mesa at the Nevada Test Site contains about 8.0E+07 curies of radioactivity caused by underground nuclear testing. The Underground Test Area Subproject has entered Phase II of data acquisition, analysis, and modeling to determine the risk to receptors from radioactivity in the groundwater, establish a groundwater monitoring network, and provide regulatory closure. Evaluation of radionuclide contamination at Pahute Mesa is particularly difficult due to the complex stratigraphy and structure caused by multiple calderas in the Southwestern Nevada Volcanic Field and overprinting of Basin and Range faulting. Included in overall Phase II goals is the need to reduce the uncertainty and improve confidence in modeling results. New characterization efforts are underway, and results from the first year of a three-year well drilling plan are presented.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

p-values for model evaluation

Deciding whether a model provides a good description of data is often based on a goodness-of-fit criterion summarized by a p-value. Although there is considerable confusion concerning the meaning of p-values, leading to their misuse, they are nevertheless of practical importance in common data analysis tasks. We motivate their application using a Bayesian argumentation. We then describe commonly and less commonly known discrepancy variables and how they are used to define p-values. The distribution of these are then extracted for examples modeled on typical data analysis tasks, and comments on their usefulness for determining goodness-of-fit are given.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Low-Energy Parameters of Neutron–Neutron Interaction: Analysis of Data Obtained in nd and dd Breakup Reactions

Data obtained in recent years for the neutron–neutron scattering length in nd and dd breakup reactions are analyzed. Serious discrepancies between experimental data from different studies may be explained by the effect of three-nucleon forces depending on the velocity of separation of a neutron–neutron pair and a charged fragment. It is shown that the data under analysis can be approximated by a smooth curve representing the dependence of the scattering length on the parameter R, which determines the fragment-separation distance after a fixed time. This dependence makes it possible to obtain the scatteringlength value for R→∞—that is, in the absence of the effect of three-nucleon forces.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Efficient Data Compression for 3D Sparse TPC via Bicephalous Convolutional Autoencoder

Real-time data collection and analysis in large experimental facilities present a great challenge across multiple domains, including high energy physics, nuclear physics, and cosmology. To address this, machine learning (ML)-based methods for real-time data compression have drawn significant attention. However, unlike natural image data, such as CIFAR and ImageNet that are relatively small-sized and continuous, scientific data often come in as three-dimensional 3D data volumes at high rates with high sparsity (many zeros) and non-Gaussian value distribution. This makes direct application of popular ML compression methods, as well as conventional data compression methods, suboptimal. To address these obstacles, this work introduces a dual-head autoencoder to resolve sparsity and regression simultaneously, called Bicephalous Convolutional AutoEncoder (BCAE). This method shows advantages both in compression fidelity and ratio compared to traditional data compression methods, such as MGARD, SZ, and ZFP. To achieve similar fidelity, the best performer among the traditional methods can reach only half the compression ratio of BCAE. Moreover, a thorough ablation study of the BCAE method shows that a dedicated segmentation decoder improves the reconstruction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The ADAQ framework: An integrated toolkit for data acquisition and analysis with real and simulated radiation detectors

Here, the ADAQ framework is a collection of software tools that is designed to streamline the acquisition and analysis of radiation detector data produced in modern digital data acquisition (DAQ) systems and in Monte Carlo detector simulations. The purpose of the framework is to maximize user scientific pro-ductivity by minimizing the effort and expertise required to fully utilize radiation detectors in a variety of scientific and engineering disciplines. By using a single set of tools to span the real and simulation domains, the framework eliminates redundancy and provides an integrated workflow for high-fidelity comparison between experimental and simulated detector performance. Built on the ROOT data analysis framework, the core of the ADAQ framework is a set of Cþþ and Python libraries that enable high-level control of digital DAQ systems and detector simulations with data stored into standardized binary ROOT files for further analysis. Two graphical user interface programs utilize the libraries to create powerful tools: ADAQAcquisition handles control and readout of real-world DAQ systems and ADAQAnalysis provides data analysis and visualization methods for experimental and simulated data. At present, the ADAQ framework supports digital DAQ hardware from CAEN S.p.A. and detector simulations performed in Geant4; however, the modular design will facilitate future extension to other manufacturers and simulation platforms.

detector simulation↗

Spin cutoff factor and level density for Ni 59 from an analysis of compound nuclear reactions

The spin cutoff parameter for 59 Ni has been studied from different types of experimental data, including neutron angular distributions from the 56 Fe(α,n) 59 Ni reaction, spin of discrete levels, the level density from the proton evaporation spectrum of the 54 Fe( 6 Li,p) 59 Ni reaction and neutron resonance spacing. Experimental data points were compared with calculations using models widely used in literature. It was found that the available empirical models overestimate data points in the energy region below the neutron separation energy, while microscopic calculations which take into account pairing correlations within Hartree-Fock +Bardeen-Cooper-Schrieffer approach are consistent with data. As a result, it confirmed earlier findings that pairing correlations play an important role and need to be taken into account when the spin cutoff parameter is calculated below the neutron separation energy.

(a,n) reaction↗

FLASSH 1.0: Thermal Scattering Law Evaluation and Cross Section Generation

The Full Law Analysis Scattering System Hub ( FLASSH ) is an advanced code which evaluates the thermal scattering law (i.e. TSL, S(α,β)) for thermal scattering cross sections and resonance Doppler broadening. The ability to accurately capture these two key cross section features is dependent on accurate, high fidelity TSL evaluations. FLASSH 1.0 provides advanced physics capabilities resulting in an improved, generalized TSL to most accurately represent the lattice dynamics within any material. This improved TSL will allow for consistent analysis in both the thermal and epithermal energy ranges. The features for TSL analysis are packaged within the FLASSH GUI for easy user interface along with data output in many file formats including ENDF File 7 and ACE files.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of autonomous gamma dose logger for environmental monitoring

Continuous monitoring and archiving of background radiation levels in and around the nuclear installation is essential and the data would be of immense use during analysis of any untoward incidents. A portable Geiger Muller detector based autonomous gamma dose logger (AGDL) for environmental monitoring is indigenously designed and developed. The system operations are controlled by microcontroller (AT89S52) and the main features of the system are software data acquisition, real time LCD display of radiation level, data archiving at removable compact flash card. The complete system operates on 12 V battery backed up by solar panel and hence the system is totally portable and ideal for field use. The system has been calibrated with Co-60 source (8.1 MBq) at various source-detector distances. The system is field tested and performance evaluation is carried out. This paper covers the design considerations of the hardware, software architecture of the system along with details of the front-end operation of the autonomous gamma dose logger and the data file formats. The data gathered during field testing and inter comparison with GammaTRACER are also presented in the paper. AGDL has shown excellent correlation with energy fluence monitor tuned to identify {sup 41}Ar, proving its utility for real-time plume tracking and source term estimation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data transfers for full core heterogeneous reactor high- fidelity multiphysics studies

Multiphysics simulations for nuclear reactor analysis are usually performed by resorting to operator splitting and fixed point iterations between single-physics solvers. This enables the separate solution of each physics, such as neutronics, fuel performance, and thermal hydraulics, on meshes tailored to the requirements of the respective numerical discretizations of the equations. As the equations are coupled, several fields must be transferred between single-physics solves. Projecting fields between meshes while preserving order of accuracy, conservation properties, and mapping non-overlapping geometries is a complex endeavor. This conference paper will present the transfers as implemented in MOOSE, which can handle arbitrary meshes, arbitrary mappings, conservation of integral quantities, and are made to scale with distributed simulations on both ends of the transfers. Their adequacy for advanced nuclear reactor multiphysics coupling is shown through examples and numerical studies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nonlinear Seismic Correlation Analysis of the JNES/NUPEC Large-Scale Piping System Tests.

The Japan Nuclear Energy Safety Organization/Nuclear Power Engineering Corporation (JNES/NUPEC) large-scale piping test program has provided valuable new test data on high level seismic elasto-plastic behavior and failure modes for typical nuclear power plant piping systems. The component and piping system tests demonstrated the strain ratcheting behavior that is expected to occur when a pressurized pipe is subjected to cyclic seismic loading. Under a collaboration agreement between the US and Japan on seismic issues, the US Nuclear Regulatory Commission (NRC)/Brookhaven National Laboratory (BNL) performed a correlation analysis of the large-scale piping system tests using derailed state-of-the-art nonlinear finite element models. Techniques are introduced to develop material models that can closely match the test data. The shaking table motions are examined. The analytical results are assessed in terms of the overall system responses and the strain ratcheting behavior at an elbow. The paper concludes with the insights about the accuracy of the analytical methods for use in performance assessments of highly nonlinear piping systems under large seismic motions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NEXUS-DC: Nuclear Energy eXpedition for US Data Centers [Slides]

This presentation covers the growing interest in utilizing nuclear power to satisfy the increasing energy demands of data centers in the United States, emphasizing the factors that accelerate reactor deployment. It addresses clean and reliable energy needs, highlights the importance of power supply redundancy for reliability, and discusses challenges and solutions related to cooling, waste heat reuse, and techno-economics. Additionally, it includes a strength, weakness, opportunities and threat analysis and emphasizes community engagement and collaboration for accelerating regulatory approvals and reactor deployment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Benchmark Calculation for the Hatch Unit 1 Cycles 1-3 Using the SCALE 6.3/Polaris–PARCS v3.4.2 Code Package

This study was the performance of the benchmark calculation for the Hatch Unit 1 cycles 1–3, to validate the SCALE 6.3/Polaris–PARCS v3.4.2 with the ENDF/B-VII.1 AMPX 56-group library by comparing the simulated results with the measured data. The benchmark results will be used in evaluating uncertainties of the SCALE/Polaris–PARCS code package for boiling water reactor (BWR) physics analysis for key nuclear parameters such as reactivity and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS and PARCS, and additionally, detailed information is provided for all the input and output files produced for the benchmark calculations. The benchmark results were summarized such that they can be used in evaluating uncertainties for key nuclear parameters with other BWR benchmark results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experiences at the Paul Scherrer Institute With a Remote Patient Positioning Procedure for High-Throughput Proton Radiation Therapy

Purpose: To describe a remote positioning system for accurate and efficient proton radiotherapy treatments. Methods and Materials: To minimize positioning time in the treatment room (and thereby maximize beam utility), we have adopted a method for remote patient positioning, with patients positioned and imaged outside the treatment room. Using a CT scanner, positioning is performed using orthogonal topograms with the measured differences to the reference images being used to define daily corrections to the patient table in the treatment room. Possible patient movements during transport and irradiation were analyzed through periodic acquisition of posttreatment topograms. Systematic and random errors were calculated for this daily positioning protocol and for two off-line protocols. The potential time advantage of remote positioning was assessed by computer simulation. Results: Applying the daily correction protocol, systematic errors calculated over all patients (n = 94) were below 0.6 mm, whereas random errors were below 1.5 mm and 2.5 mm, respectively, for bite-block and for mask immobilization. Differences between pre- and posttreatment images were below 2.8 mm (SD) in abdominal/pelvic region, and below 2.4 mm (SD) in the head. Retrospective data analysis for a subset of patients revealed that off-line protocols would be significantly less accurate. Computer simulations showed that remote positioning can increase patient throughput up to 30%. Conclusions: The use of a daily imaging and correction protocol based on a 'remote' CT could reduce positioning errors to below 2.5 mm and increase beam utility in the treatment room. Patient motion between imaging and treatment were not significant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An innovative acoustic sensor for first in-pile fission gas release determination - REMORA 3 experiment

A fuel rod has been instrumented with a new design of an acoustic resonator used to measure in a non destructive way the internal rod plenum gas mixture composition. This ultrasonic sensor has demonstrated its ability to operate in pile during REMORA 3 irradiation experiment carried out in the OSIRIS Material Testing Reactor (CEA Saclay, France). Due to very severe experimental conditions such as temperature rising up to 150 deg.C and especially, high thermal fluence level up to 3.5 10{sup 19} n.cm{sup 2}, the initial sensor gas speed of sound efficiency measurement was strongly reduced due to the irradiation effects on the piezo-ceramic properties. Nevertheless, by adding a differential signal processing method to the initial data analysis procedure validated before irradiation, the gas resonance peaks were successfully extracted from the output signal. From these data, the molar fractions variations of helium and fission gas were measured from an adapted Virial state equation. Thus, with this sensor, the kinetics of gas release inside fuel rods could be deduced from the in-pile measurements and specific calculations. These data will also give information about nuclear reaction effect on piezo-ceramics sensor under high neutron and gamma flux. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

On the dosimetric effect and reduction of inverse consistency and transitivity errors in deformable image registration for dose accumulation

Purpose: Deformable image registration (DIR) is necessary for accurate dose accumulation between multiple radiotherapy image sets. DIR algorithms can suffer from inverse and transitivity inconsistencies. When using deformation vector fields (DVFs) that exhibit inverse-inconsistency and are nontransitive, dose accumulation on a given image set via different image pathways will lead to different accumulated doses. The purpose of this study was to investigate the dosimetric effect of and propose a postprocessing solution to reduce inverse consistency and transitivity errors. Methods: Four MVCT images and four phases of a lung 4DCT, each with an associated calculated dose, were selected for analysis. DVFs between all four images in each data set were created using the Fast Symmetric Demons algorithm. Dose was accumulated on the fourth image in each set using DIR via two different image pathways. The two accumulated doses on the fourth image were compared. The inverse consistency and transitivity errors in the DVFs were then reduced. The dose accumulation was repeated using the processed DVFs, the results of which were compared with the accumulated dose from the original DVFs. To evaluate the influence of the postprocessing technique on DVF accuracy, the original and processed DVF accuracy was evaluated on the lung 4DCT data on which anatomical landmarks had been identified by an expert. Results: Dose accumulation to the same image via different image pathways resulted in two different accumulated dose results. After the inverse consistency errors were reduced, the difference between the accumulated doses diminished. The difference was further reduced after reducing the transitivity errors. The postprocessing technique had minimal effect on the accuracy of the DVF for the lung 4DCT images. Conclusions: This study shows that inverse consistency and transitivity errors in DIR have a significant dosimetric effect in dose accumulation; Depending on the image pathway taken to accumulate the dose, different results may be obtained. A postprocessing technique that reduces inverse consistency and transitivity error is presented, which allows for consistent dose accumulation regardless of the image pathway followed.

61 RADIATION PROTECTION AND DOSIMETRY↗