Search NASA⌕ Search

SEARCH · Search NASA

Results for “Object Model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Bayesian optimization for inverse calibration of expensive computer models: A case study for Johnson-Cook model in machining

Inverse model calibration for identifying the constitutive model parameters can be computationally demanding for expensive-to-evaluate simulation models. Here, this paper presents a modified Bayesian optimization (BO) method, denoted as BO-bound, that incorporates theoretical bounds on the quantity of interest. A case study for the inverse calibration of the Johnson Cook (J-C) flow stress model parameters is presented using machining (cutting) force data. The results show fast calibration of the five J-C parameters within 25 simulations. In general, the BO-bound method is applicable for inverse calibration of any expensive simulation models as well as optimization problems with known bounds.

Bayesian optimization↗

Forecasting for ESCAPE: A Multi-Institution Hybrid Forecasting and Nowcasting Operation for Sea-Breeze Convection Supporting a Ground-Based and Airborne Field Campaign

The Experiment of Sea-Breeze Convection, Aerosols, Precipitation and Environment (ESCAPE) field project deployed two aircraft and ground-based assets in the vicinity of Houston, Texas, between 27 May and 2 July 2022, examining how meteorological conditions, dynamics, and aerosols control the initiation, early growth stage, and evolution of coastal convective clouds. To ensure that airborne- and ground-based assets were deployed appropriately, a forecasting and nowcasting team was formed. Daily forecasts guided real-time decision-making by assessing synoptic weather conditions, environmental aerosol, and a variety of atmospheric modeling data to assign a probability for meeting specific ESCAPE campaign objectives. During the research flights, a small team of forecasters provided “nowcasting” support by analyzing radar, satellite, and new model data in real time. The nowcasting team proved invaluable to the campaign operation, as sometimes changing environmental conditions affected, for example, the timing of convective initiation. In addition to the success of the forecasting and nowcasting teams, the ESCAPE campaign offered a unique “testbed” opportunity where in-person and virtual support both contributed to campaign objectives. The forecasting and nowcasting teams were each composed of new and experienced forecasters alike, where new forecasters were given invaluable experience that would otherwise be difficult to attain. Both teams received training on forecast models, map analysis, Hybrid Single-Particle Lagrangian Integrated Trajectory model (HYSPLIT), and thermodynamic sounding analysis before the beginning of the campaign. In this article, the ESCAPE forecasting and nowcasting teams reflect on these experiences, providing potentially useful advice for future field campaigns requiring forecasting and nowcasting support in a hybrid virtual/in-person framework.

54 ENVIRONMENTAL SCIENCES↗

pnnl/projection_ntk

This is a repository for work conducted in our research paper we would like to make open source. The main features are that we forked another open source library and added functionality that enabled us to compute neural-kernel objects using random vector projection software for both computer vision and large language text models. The new features are specifically code that enables the calculation of objects we define and refer to as the projection pseudo neural tangent kernel and the projection trace neural tangent kernel; both of which are approximations of the empirical neural tangent kernel. The software that computes the projections themselves are not part of the invention, but are necessarily tied to our software and licensed via MIT license, and BSD 2 license.

Georgiev, Kristian↗

An Overview of the State-of-the-Art Reactor Consequence Uncertainty Assessment Accident Progression Insights

The U.S. Nuclear Regulatory Commission (NRC) with Sandia National Laboratories (Sandia) have completed three uncertainty analyses (UAs) as part of the State-of-the-Art Reactor Consequence Analyses (SOARCA) program. The SOARCA UAs included an integrated evaluation of uncertainty in accident progression, radiological release, and offsite health consequence projections. The UA for Peach Bottom, a boiling-water reactor (BWR) with a Mark I containment located in the State of Pennsylvania, analyzed the unmitigated long-term station blackout SOARCA scenario. The UA for Sequoyah, a 4-loop Westinghouse pressurized-water reactor (PWR) located in the State of Tennessee, analyzed the unmitigated short-term station blackout SOARCA scenario, with a focus on issues unique to the ice condenser containment and the potential for early containment failure due to hydrogen deflagration. The UA for Surry, a 3-loop Westinghouse PWR with a sub-atmospheric large dry containment located in the State of Virginia, analyzed the unmitigated short-term station blackout SOARCA scenario including the potential for thermally-induced steam-generator tube rupture. These three UAs are currently documented in three NUREG/CR reports. This report provides input to planned NRC documentation on the insights and findings from the SOARCA UA program. The purpose of the summary report is to provide a useful reference for regulatory applications that require the evaluation of offsite consequence risk from beyond design basis event severe accidents. This report focuses on the accident progression and source term insights developed from the MELCOR analyses. MELCOR is the NRC's best-estimate, severe accident computer code used in the SOARCA UAs. In anticipation of the SOARCA UA insights work, NRC and Sandia benchmarked the response of the Peach Bottom model to selected reference calculations from the Peach Bottom SOARCA UA. Peach Bottom was the first SOARCA UA performed and was completed in 2015 using the MELCOR 1.8.6 code. The PWR SOARCA UAs evolved the original methodology and utilized the updated MELCOR 2.2 computer code. The Peach Bottom model has been systematically updated for other NRC research efforts and has been updated to MELCOR 2.2. computer code. The findings from the new reference calculations using the updated model with the MELCOR 2.2 code are also integrated into the report. A second objective is an assessment of the applicability of the results to the other nuclear reactors in the U.S. As the key findings are reviewed, judgments are presented on the applicability of the results to other U.S. nuclear power plants. An important objective of the SOARCA program relied on high- fidelity plant-specific modeling. However, the nature of the insights and conclusions allowed judgements to be made on the applicability of the various insights to the same general classification of plant (i.e., BWR or PWR) or the entire fleet of plants. Finally, the results from the SOARCA UA accident progression calculations contain a wealth of information not previously documented in the NUREG/CRs. This report includes new but related information that can be used to benchmark past or support future regulatory decisions related to severe accidents. The new work includes a benchmark of the NUREG-1465 licensing source term definitions, the variability of key accident progression events and timing to radionuclide release, and an improved understanding of the timing and source terms from consequential steam generator tube ruptures. iii ACKNOWLEDGEMENTS The Sandia authors gratefully acknowledge the significant technical and programmatic contributions from the NRC SOARCA team which are reflected throughout the report. Dr. Tina Ghosh has been involved throughout the SOARCA UAs, providing the primary managerial and technical oversight. The long lists of NRC and Sandia contributors from the SOARCA UAs are cited in the three NUREG/CRs and are also gratefully acknowledged by the small team of authors compiling the results of their efforts. Significant technical contributions, advice, and reviews were provided by Dr. Hossein Esmaili, Dr. Alfred Hathaway, and Dr. Edward Fuller (retired) of the NRC. Dr. Randal Gauntt (retired), Mr. Patrick Mattie, Mr. Joseph Jones (retired), and Dr. Doug Osborn from Sandia are recognized as the SOARCA UA managers guiding the past efforts. There is a comparable list of project managers at the NRC including Ms. Patricia Santiago, Dr. Salman Haq, and Mr. Jon Barr. Sadly, we have lost Mr. Charlie Tinkler and Mr. Robert Prato, who were important contributors to the original SOARCA project. Finally, Mr. Kyle Ross and Mr. Mark Leonard have also retired but were significant technical contributors. Mr. Kyle Ross was the technical lead on all three SOARCA UAs and the original pressurized water reactor SOARCA study. Mr. Leonard was the technical lead on the original boiling water reactor SOARCA study and a key contributor to the first Peach Bottom SOARCA UA. iv

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

End-Use Savings Shapes Measure Documentation: Electric Cooking Equipment

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past three years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. “Measures” refers to energy efficiency variables that can be applied to buildings during modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards a NEAMS-based high-fidelity model of the MARVEL reactor

This report outlines the progress of Idaho National Laboratory in developing a high-fidelity and high-resolution model of the Microreactor Applications Research Validation and Evaluation reactor. The model was developed under the Nuclear Energy Advanced Modeling and Simulation microreactor application driver at Idaho National Laboratory. The overarching objective of this activity is the development of a high-fidelity multiphysics MARVEL model using NEAMS tools, and to verify and validate NEAMS tools against MARVEL reference simulation and experimental data, respectively. This is a unique opportunity to conduct multiphysics analysis on a soon-to-be-deployed microreactor. This multiphysics model developed under the NEAMS-funded INL microreactor application driver leverages three single-physics models coupled via the MOOSE’s MultiApp and Transfer systems. The latter systems enable in-memory data transfer between MOOSE-based and MOOSE-wrapped applications. The first single-physics model, that functions as main application, leverages Griffin to model the neutron transport in the core through the discontinuous finite element (DFEM) discrete ordinates solver (SN). Several optimization flags that were developed by the Griffin developer team were beta-tested to enhance the solver’s performance. These include the combined use of using_average_xs and update_averaged_xs_on that enable to avoid expensive on-the-fly cross sections evaluations at each linear iterations in favor of evaluations of the macroscopic cross sections at each Picard iteration. The second single-physics model uses BISON to handle solid heat transfer and asymptotic hydrogen redistribution analysis in the fuel. While the model returns consistent results for the temperature and hydrogen distribution in the fuel, a mismatch was noticed in the calculated temperature in the reflector due to the value of the gap conductance used in our model. Ongoing investigations are being performed to assess the origin of this discrepancy. Finally, the System Analysis Module (SAM) was used to model the flow of the sodium-potassium eutectic in the primary loop. A first verification was also performed showing good agreement in terms of mass flow rate and inlet temperature. All mesh files were generated using the MOOSE Reactor module, removing the need for external meshing tools. Notably, this workscope represents one of the initial applications of the MOOSE Reactor module for modeling highly irregular geometries. The use of the reactor module significantly streamlined the mesh generation process. The full multiphysics mode, that combines all the single physics models, was leveraged to conduct initial steady-state multiphysics simulations to compute power, and temperature distribution in the reactor. Initial testing was performed for transient simulations as well. In this case, the new checkpoint restart capability for eigenvalue calculations was tested showing the capability for streamlined restart of transient calculations. Future work will focus on improving the fidelity of the model by performing comprehensive code-to-code comparisons. For instance, the full-core Griffin neutronics model will be benchmarked against MCNP reference results, that were provided by the MARVEL design team. Additionally, the SAM T/H model will be verified against reference RELAP-5 results for selected accident scenarios. Besides code-to-code verification exercises, the model fidelity will be improved by replacing the single-channel SAM model with a more complex SAM-Pronghorn coupled model, in which the sub-channel capability is deployed to obtain radial temperature resolution in the coolant. This model will be developed in synergy with the NEAMS thermal hydraulics team.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimal vocabulary selection approaches for privacy-preserving deep NLP model training for information extraction and cancer epidemiology

With the use of artificial intelligence and machine learning techniques for biomedical informatics, security and privacy concerns over the data and subject identities have also become an important issue and essential research topic. Without intentional safeguards, machine learning models may find patterns and features to improve task performance that are associated with private personal information. The privacy vulnerability of deep learning models for information extraction from medical textural contents needs to be quantified since the models are exposed to private health information and personally identifiable information. The objective of the study is to quantify the privacy vulnerability of the deep learning models for natural language processing and explore a proper way of securing patients’ information to mitigate confidentiality breaches. The target model is the multitask convolutional neural network for information extraction from cancer pathology reports, where the data for training the model are from multiple state population-based cancer registries. This study proposes the following schemes to collect vocabularies from the cancer pathology reports; (a) words appearing in multiple registries, and (b) words that have higher mutual information. We performed membership inference attacks on the models in high-performance computing environments. The comparison outcomes suggest that the proposed vocabulary selection methods resulted in lower privacy vulnerability while maintaining the same level of clinical task performance.

59 BASIC BIOLOGICAL SCIENCES↗

Emerging Flexible Designs for Geospatial Multimodal Foundation Models

Foundation models are rapidly transforming Earth observation by enabling scalable pretraining across diverse unlabeled geospatial modalities. However, their architectural diversity—ranging from encoder-only to encoder-decoder and masked autoencoding paradigms—makes it challenging to assess performance trade-offs in a consistent manner. In this work, we present an apples-to-apples comparison of leading FM architectures designed for geospatial multimodal reasoning, with a particular focus on flexibility across varied spectral band configurations. We standardize pretraining using identical self-supervised learning objectives and training datasets, and evaluate all models under consistent parameterization on the GEOBench benchmark across classification and segmentation tasks. Our results offer new insights into the design trade-offs between model flexibility, modality alignment, and downstream task performance. By highlighting architectural strengths and limitations under controlled conditions, this study provides practical guidance for building next-generation geospatial foundation models capable of robust multimodal reasoning.

Ambrozio Dias, Philipe [ORNL] (ORCID:0000000194277↗

Query relaxation for portable brick-based applications

Semantic metadata standards pave the way for interoperability by providing building operators and application developers with common schemes to describe building resources. Applications can query building metadata models to retrieve the set of entities and relationships they need to operate, instead of hard-coding references to specific points and objects from the underlying data sources. Currently, querying such models requires the developer to be very specific when formulating queries in order to obtain meaningful answers (or any answer). The developer is inevitably expected to be familiar with the systems and components of the buildings being queried, as well as the schema used to represent them. The variety of buildings - both in the composition of their subsystems and in how they happen to be modeled - means that the developer will need to use multiple queries in order to retrieve necessary results. This is complex, time-consuming and error-prone. To address this limitation, we investigate query relaxation as a technique to facilitate discovery of meaningful building resources in a collection of ontology-based buildings data. We evaluate our query relaxation approach over a set of Brick models and demonstrate its use in the context of real-world building applications.

Brick↗

ALMA observations of Orion Source I at 350 and 660 GHz

Orion Source I (“SrcI”) is the protostar at the center of the Kleinmann-Low Nebula. ALMA observations of SrcI with 0.″2 angular resolution were made at 350 and 660 GHz to search for the H26α and H21α hydrogen recombination lines and to measure the continuum flux densities. The recombination lines were not detected, ruling out the possibility that SrcI is a hypercompact H ii region. The deconvolved size of the continuum source is approximately 0.″23 × 0.″07 (∼100 × 30 au); it is interpreted as a disk viewed almost edge-on. Optically thick thermal emission from ∼500 K dust is the most plausible source of the continuum, even at frequencies as low as 43 GHz; the disk mass is most likely in the range 0.02–0.2 M{sub ⊙}. A rich spectrum of molecular lines is detected, mostly from sulfur- and silicon-rich molecules like SO, SO{sub 2}, and SiS, but also including vibrationally excited CO and several unidentified transitions. Lines with upper energy levels E{sub U}>500 K appear in emission and are symmetric about the source’s LSR velocity of 5 km s{sup −1}, while lines with E{sub U}<500 K appear as blueshifted absorption features against the continuum, indicating that they originate in outflowing gas. The emission lines exhibit a velocity gradient along the major axis of the disk that is consistent with rotation around a 5–7 M{sub ⊙} central object. The relatively low mass of SrcI and the existence of a 100 au disk around it are difficult to reconcile with the model in which SrcI and the nearby Becklin–Neugebauer Object were ejected from a multiple system 500 years ago.

79 ASTRONOMY AND ASTROPHYSICS↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: LED Lighting

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a timeseries profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - LED lighting. The LED lighting measure replaces interior lights with LEDs where applicable. The measure resulted in 1.25 TBtu energy savings across the building stock, with the majority of savings occurring in retail and warehouse buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Economizers

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Electric Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock TM and ComStock TM models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure—boiler replacement by air-source heat pump boiler. This measure replaces space heating natural gas boilers by air-source heat pump boilers when applicable and helps quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 2.9. The total natural gas energy consumption was reduced by 20%, whereas the total electricity consumption was increased by 2.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Natural Gas Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock (™) and ComStock (™) models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - boiler replacement with air-source heat pump boiler with natural gas boiler backup. This measure replaces natural gas boilers for HVAC application by air-source heat pump boilers when applicable and use natural gas boiler backup when the heat pump boiler could not operate due to outdoor air conditions which are below its cutoff temperature. This measure helps to quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 3. The total natural gas energy consumption was reduced by 41%, whereas the total electricity consumption was increased by 5.3%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation, New Windows, LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility enduse load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. “Measures” refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗