A Prototype Dual Robot System to Perform Ultrasonic and Visual Inspection for the Bottom of Double-Shell Tanks - 18624

Up to this point, ultrasonic inspection-based condition data has only been available for double-shell tank (DST) sidewalls because direct inspection access to the primary tank bottom is limited to vent duct channels in an insulating refractory pad that the primary tank rests on. Probe access through the air slot would provide the opportunity to get information about the condition of the bottom of the primary tank, but it is a challenge to deploy a crawling robot that is capable of performing nondestructive ultrasonic and visual inspection through confined air slots. As such, a conceptual prototype of a deployable inspection robot system to enable ultrasonic and visual inspection for DST base through ventilation ducts was designed and fabricated. This prototype dual robot system consisting of the AnnulusBot and the MouseBot can be integrated with nondestructive evaluation (NDE) sensors to inspect and examine the physical properties of the underside of DSTs to enable status assessment. The AnnulusBot was designed to carry the MouseBot and to be deployed to the annulus space through a riser. To deploy the MouseBot to every ventilation channel in the annulus, the arm consisting of a boom and a forearm was used to place the MouseBot on the underside of the tank. The AnnulusBot used segmented wheels enable to traverse pipes and other potential obstacles. The cable management system utilized motorized wheels to feed the cable into the ventilation channel. This would reduce the amount of work that the MouseBot would have to do during inspection. This feeding mechanism would also be used to retrieve the MouseBot at the end of its inspection. Additionally, if the MouseBot fails, this mechanism would be used for retrieval. Once deployed, the MouseBot navigates to the center of the tank via the air ventilation channel beneath the inner shell (the primary tank) while inspecting the space. The MouseBot is then retrieved from the channel by a combination of its own drive power and the AnnulusBot retracting the attached umbilical cord. Compare with the AnnulusBot, the physical dimensional limitations of the MouseBot were a greater challenge. As the surface state of the concrete of the air channels could have variable texture, and may contain debris, it was decided not to travel along this surface. The ceiling of these channels is carbon steel and can be utilized throughout the channel. To use this travel surface, magnetic wheels were employed. A foreseeable problem with the use of magnets on this surface, is that they would preclude the use of eddy currents sensors. However, other technologies like ultrasonic technology sensors should be unaffected. Laboratory scale test was performed on a mock-up single wedge of the refractory pad to evaluate maneuverability of the MouseBot. The electronic components for the prototype would work in the ranges of 150-185 deg. F (65.6-85 deg. C). Both the AnnulusBot and MouseBot will be subject to constant radiation. All major printed circuit board (PCB) microcontroller components were designed to be situated outside of the annulus space and inside the main control panel to avoid radiation-induced failure. As future work, electronic components including the Arduinos that used Atmel commercial microcontrollers will be replaced with the high temperature rated Atmel microcontrollers so that the robots can be operated reliably at ambient temperatures up to 200 deg. F (93.3 deg. C). In addition, the robots will be service life tested to evaluate performance at elevated temperature and under gamma irradiation. (authors)

42 ENGINEERING↗

Saltstone Facility Operating Experience with Mega-Vault Disposal Units - 19497

The Saltstone Production Facility (SPF) has been treating low-level waste aqueous salt solution at the Savannah River Site (SRS) since 1990. Salt solutions are transferred from a large-volume, underground storage tank via underground waste transfer line into the SPF. The waste is received into one of two receipt tanks and then transferred to a twin-shaft mixer where dry feeds are introduced to create a fresh grout slurry. The grout exits the mixer into a hold tank, which has a residence time of approximately two minutes. The slurry is then pumped via peristaltic pump through a grout transfer line to one of several disposal units in the Saltstone Disposal Facility (SDF). The transfer line length varies from 0.4 km to 0.8 km depending on disposal location. With the salt disposal mission at SRS accelerating via the operation of the Modular Caustic Side Solvent Extraction (MCU) facility and the anticipated startup of the Salt Waste Processing Facility (SWPF), it is important that the SPF and SDF operate with minimal outage time and maximum facility availability. To this end, the design of the newest disposal units has incorporated the benefits of commercially available cylindrical concrete tank design on a very large scale to maximize economies of scale. This new design has been placed into radioactive service and the initial operational data will be compared with previous disposal operations along with an overview of how disposal unit design has significantly evolved since the initial construction in the early 1990's. Additionally, several processing facility modifications have either been implemented or developed in recent years to improve operating reliability and ensure facility availability once the SWPF becomes the primary waste generator providing feed for the SPF. These modifications, the issues driving their development, and an assessment of their effectiveness will also be discussed. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A new probe concept for internal pipework inspection - 241

The interior visual inspection of nuclear pipework is a critical inspection activity required to ensure the continued safe, reliable operation of plant and thus avoid costly outages. Typically, the video output from a manually deployed probe is viewed by an operator online with the task of identifying and estimating the location of surface defects such as cracks, corrosion and pitting. However, it is very difficult to estimate the nature and spatial extent of defects from the often disorientating small field of view video of a relatively large structure. This work describes a new visual inspection system incorporating a wide field of view machine vision camera and additional sensors designed for inspecting 3 - 6 inch diameter pipes. The output of the system is a photorealistic model of the internal surface of the pipework. The generation of this model relies upon a core component of the system in the form of image feature extraction which estimates camera location. This paper considers the accuracy of this estimation as a function of the number and configuration of the extracted image features. (authors)

42 ENGINEERING↗

Development of Scaling Criteria for Modeling Condensation in Horizontal Tubes Using Reduced Pressure System and Simulant Fluid

Most of the currently operating nuclear power plants (NPPs), generation-II and III, are equipped with active safety systems, which raises concerns regarding those safety systems' operational reliability and the suitability of the accidents prevention measures. Following the severe accidents at nuclear power plants at Three Mile Island, Chernobyl, and recently in Fukushima some advance Pressurized Water Reactors (PWRs) have adopted passively cooled steam generator natural circulation system to remove the decay heat passively through the steam generator (SG). This is done by condensing steam from the steam generator inside a heat exchanger submerged in a tank of water or an air cooled system. The APR+ (Advanced Power Reactor Plus), which is currently being developed in South Korea, has adopted a Passive Auxiliary Feedwater System (PAFS), which removes the decay heat through the steam generator replacing the conventional active auxiliary feedwater system. The main part of the PAFS, in where the steam condenses, is the Passive Condensation Heat Exchanger (PCHX). The steam condenses under high pressure (7.4 MPa, 290 deg. C) in 8.4 m long horizontal tube, with 3 degrees inclination, with inner diameter of 44.8 mm and wall thickness of 3 mm. The PCHX consists of 4 bundles, each bundle has 60 condensation tubes. The performance of the PCHX performance should be evaluated. Condensation has been extensively studied; however, most previous experimental work was directed to low pressure (i.e., near atmospheric pressure) and small condensation tubes. Moreover, studies on the horizontal type heat exchanger are limited, since previous safety systems and experimentation work were directed to the vertical type heat exchangers. Due to the high construction cost of a full size high pressure condensation experiment, a reduced-size reduced-pressure condensation experiment is suggested to evaluate the heat removal performance of a condensation tube of the PAFS heat exchanger. A scaling methodology to be established to design a reduced-size reduced-pressure condensation experiment. This study attempts to develop a scaling criteria for the PAFS condensation system, and to apply it for modeling a high pressure water system by a low pressure Freon system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Data-Driven Approach for High-Impedance Fault Localization in Distribution Systems: Preprint

Accurate and quick identification of high-impedance faults (HIFs) is critical for the reliable operation of distribution systems. Unlike other faults in power grids, HIFs are very difficult to detect by conventional overcurrent relays due to the low fault current. Although HIFs can be affected by various factors, the voltage-current characteristics can substantially imply how the system responds to the disturbance and thus provides opportunities to effectively localize HIFs. In this work, we propose a data-driven approach for the identification of HIF events. To tackle the nonlinearity of the voltage-current trajectory, first, we formulate optimization problems to approximate the trajectory with piecewise functions. Then we collect the function features of all segments as inputs and use the support vector machine approach to efficiently identify HIFs at different locations. Numerical studies on the IEEE 123-node test feeder demonstrate the validity and accuracy of the proposed approach for real-time HIF identification.

explainable artificial intelligence↗

Cyber-Enabled Sabotage, Critical Function Assurance, and Cyber-Informed Engineering

Cyber-enabled Sabotage, Critical Function Assurance, and Cyber-Informed Engineering: This discussion will introduce the idea of cyber-enabled sabotage, and the role engineering plays in the cyber defense of critical functions with a focus on electric power systems. It will outline how and why engineering practice must be used to apply cybersecurity principles to establish safe and reliable operations even in the face of determined and skilled adversaries, and give an overview of INL’s Consequence-Driven Cyber-Informed Engineering methodology to apply these principles. There will be an opportunity for audience questions and answers at the end of the session.

42 ENGINEERING↗

Digitalization mapping and assessment process supporting ION strategic transformation activities

The existing fleet of commercial nuclear power plants (NPPs) are an important asset in the nation’s portfolio of electrical generating resources. Their continued safe and reliable operation are critical to providing a large source of carbon-free electricity to power the nation’s economy. The United States Department of Energy’s (DOE) Light Water Reactor Sustainability (LWRS) Program develops the scientific bases, methods, and tools, for the continued safe and economical operation of the nation's commercial NPPs. The Plant Modernization Pathway within LWRS Program focuses on providing guidance to industry on the full-scale implementation of modernization solutions for NPPs that significantly reduce the technical and financial risks associated with modernization. This research is focused on helping the nuclear industry understand how to digitize and digitalize their NPPs so that they can design their modernization solutions to be scalable, sustainable, and integrated both laterally and horizontally within their organization. That is, this research creates a digital transformation in NPPs by reshaping cultural mindsets and by identifying business efficiencies. In partnership with industry, and using four previously established guiding principles for digitalization, this research supported NPP modernization through assessing readiness for digitalization as a means to achieve integrated operations for nuclear. Specifically, this research created an assessment to review an entire organization’s work processes to gather information about the digitalization health of the plant. The assessment tools were administered to plant employees, and the results were used to develop a digitalization plan. The survey assessment identified the optimal candidate processes that would most benefit from a digitalization initiative which were revealed through analytical frameworks. One analysis calculated mean digitalization health indicator scores for all endorsed activities which allowed the researchers to rank and color code the results for easy identification. Individual health indicator scores are also provided, should our industry partner wish to understand these findings according to their own organizational priorities, business considerations and desired end-state. The results were also analyzed from the perspective that organizations are comprised of different types of innovators (e.g., generators, optimizers, conceptualizers, and implementers), which differentially affects the organization’s ability to comprehend and adapt to change (i.e., opportunities to innovate). Understanding the relative composition of innovator types at an NPP allows them to gather insights into the strengths and weaknesses they have in innovating how work is performed. For the utility that partnered with this research team, the results showed that implementers make up the largest portion of respondents and conceptualizers the smallest portion. Knowing the proportion of innovator types gave this organization insights on how they can effectively implement their innovation solutions. Additionally, the results were analyzed from a technical, economic, and risk perspective to identify and quantify work reduction opportunities (WROs). Recognizing that not all cost-saving opportunities are the same, a Technical, Economic and Risk Assessment (TERA) was performed to evaluate WROs to identify areas of greatest potential and lowest risk. The key results from TERA included a digitalization opportunity score for each activity, and a calculation of potential cost savings. These two outputs formed the bases for calculating a priority index and rank for the activities/processes assessed. From the prioritization calculations, TERA can then help the utility 1) decide what digitalization priorities to invest money in implementing and then 2) calculates how much should be invested in the digitalization initiatives selected to achieve cost savings and/or an acceptable return on investment. Last, onsite interviews revealed several inefficiencies in the standard work processes that occur cross-departmentally that are due to the absence of digitized and digitalized processes. Examples of these include time spent scanning paper documents and then uploading the documents electronically, obtaining signatures, and searching for desired information. This represents a digital but not digitalized process. Over 15 opportunities to improve work processes were identified through this multi-method digitalization assessment. The various analytical assessments used (e.g., TERA, digitalization health indicator scores), as well as discussions with the utility partner, corroborated that all the opportunities identified had a strong potential to make work processes more efficient and to improve overall performance of the NPP.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Environmental degradation testing of Alloy 709

Alloy 709 is an advanced austenitic stainless steel developed to meet the demanding conditions of sodium fast reactors (SFRs) but may also be of use for lead fast reactors, high temperature gas reactors, and molten salt reactors. Understanding environmental degradation modes and quantifying degradation rates are crucial to ensure the long-term, reliable operation of these reactors. This paper discusses recent neutron irradiation results, future neutron irradiation test plans, and sodium corrosion testing to communicate current best understanding of the performance of Alloy 709 in SFR environments.

A709↗

Novel Preprocessing Techniques for Enhancing Flowability of Miscanthus

Purpose-grown energy crops possess significant potential as promising feedstocks for biofuel and biochemical production. However, similar to other biomass feedstocks, their utilization has been hindered by handling and feeding challenges such as clogging and segregation, which prevent biorefineries from operating at full capacity. These challenges arise primarily due to particle attributes including irregular shape, high flexibility, and high compressibility, leading to interlocking, high compaction, and significant friction under stress consolidation. To enhance operational reliability, it is crucial to focus on preprocessing techniques to address these issues, alongside accurately characterizing the mechanical and physical properties and flow performance of these feedstocks. This study investigates novel preprocessing techniques, including pelletization and torrefaction, to fundamentally alter these particle attributes and improve flowability. Miscanthus, an herbaceous energy crop, was the primary focus of this study. Samples were processed using a Forest Concepts Crumbler rotary shear system and an oscillating multi-stack screen bed to achieve two nominal (baseline) particle sizes: 6mm and 2mm. The study evaluated the efficiency and energy consumption of size reduction, revealing that while 2mm particles required more energy, they exhibited better flowability and higher yield strength compared to 6mm particles. Shear and compression tests assessed the material's shear strength, internal friction, and elastic modulus, while wedge-shaped hopper tests measured the critical arching distance and mass flow rate. The results provide valuable insights into the mechanical properties and processing efficiency of Miscanthus, contributing to the development of a preprocessing framework that enhances energy efficiency and material flowability in bioenergy production. However, further preprocessing and development are required to optimize this framework fully.

09 - BIOMASS FUELS↗

From Obsolete to Optimal (ATR Demineralized Water System)

My project was migrating a Human-Machine Interface (HMI) and Programmable Logic Controller (PLC) program from legacy software to a modern platform, enhancing operational efficiency and eliminating unsupported, obsolete equipment. Initially, I used a migration tool to transfer the programs to the new software, then manually updated variables to align with the new PLC. I optimized the PLC code by leveraging new scaling features in the I/O cards, removing over 45 obsolete rungs, and enhancing clarity with functional tag aliases. Next, I modernized the HMI's visuals with an updated color scheme and 3D buttons. I developed multiple interface versions iteratively refining them based on operator feedback. I also designed and created a dedicated "Rounds" screen incorporating insights from a previous intern’s project to streamline daily rounds. To improve clarity, consistency, and efficiency I redesigned the entire interface. Adding visual indicators to enhance operational awareness: red is used for values outside normal specifications, green for normal operating modes, yellow for manual mode, and grey for offline units. Additionally, I added a dynamic visual representation of tank levels, creating PLC logic to show the level in inches as well as inches and feet. I then incorporated a navigation sidebar to facilitate efficient screen transitions. Risk of human error was mitigated by defining narrow input ranges for tank level shutoff and password protecting setpoint changes. I also fixed issues with datatypes that caused inaccuracies in the original code. Overall, this comprehensive upgrade significantly enhanced the HMI's functionality, user experience, and operational reliability.

47 - OTHER INSTRUMENTATION↗

The design and implementation of the machine protection system for the Fermilab electron cooling facility

The Fermilab Recycler ring employs an electron cooler to store and cool 8.9-GeV antiprotons. The cooler is based on a 4.3-MV, 0.1-A, DC electrostatic accelerator for which current losses have to remain low ({approx}10{sup -5}) in order to operate reliably. The Machine Protection System (MPS) has been designed to interrupt the beam in a matter of 1-2 {micro}s when losses higher than a safe limit are detected, either in the accelerator itself or in the beam lines. This paper highlights the various diagnostics, electronics and logic that the MPS relies upon to successfully ensure that no damage be sustained to the cooler or the Recycler ring.

43 PARTICLE ACCELERATORS↗

An Adaptive Approach to Energy Security and Assurance

The North American power network has been called the world s largest, most complex machine. This network represents an enormous continent-wide investment, including over 15,000 generators in 10,000 power plants, and miles of transmission lines, distribution networks, and control systems. It has long been recognized that existing power-delivery systems are vulnerable to natural disasters and adversarial attack. The next generation of control systems must simultaneously protect against these disruptions while integrating new generation sources and maintaining active, automated control of the grid. The grid s interconnectedness needed to provide smart grid control also increases its vulnerability to interconnect-wide disruptions that are initiated locally. While strong centralized control is essential to reliable operations, this control requires multiple, high-data-rate, two-way communication links, a powerful central computing facility, and an elaborate operation-control center, all of which present vulnerabilities. It is clearly impossible to completely protect such a widespread and complex system. The key to maintaining the integrity of this network lies in the ability to identify its critical elements and to then effectively protect these elements. This identification and targeted protection will enable parts of the network to remain operational and even automatically reconfigure in the event of local failures or threats of failure, providing dependable continuity of service. The bold concept proposed here is the communication, predictive models and fast controls that eliminate the need to protect all components from emergent contingencies, but to reconfigure actively to maintain critical functions. The transformation from laboratory applications to larger than micro grid areas will require the next generation of energy technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Trials, tribulations, and pitfalls using commercial instruments for data acquisition

Brookhaven National Laboratory's Relativistic Heavy Ion Collider (RHIC) uses many commercially available instruments - for example spectrum analyzers, oscilloscopes, digital volt meters, signal generators - as integral parts of instrumentation and control systems. Typically these systems are remotely controlled. Using commercial instruments has many benefits. Manufactures have the skill, knowledge, and experience to produce high quality products. The price performance ratio is hard to duplicate. There are also disadvantages. Proprietary interfaces, single platform drivers, and reliable operation provide challenges for implementation and unattended operation. Several of the systems used at RHIC will be described. Their issues and solutions will be presented.

43 PARTICLE ACCELERATORS↗

A Prognostic Method for Scheduling Maintenance on the P2- Marx Modulator

The SLAC National Accelerator Laboratory is developing a second generation Marx-type modulator for the ILC, the P2-Marx. The modulator is expected to operate reliably in excess of 10{sup 5} hours with minimum downtime. A prognostic system is being implemented with the development of the P2-Marx to monitor and track the health of key high voltage components. This paper discusses the way in which the prognostic system will be implemented and used to monitor the health of the P2-Marx modulator.

43 PARTICLE ACCELERATORS↗

Fully 3D Multiple Beam Dynamics Processes Simulation for the Fermilab Tevatron

The Fermilab Tevatron has been, until 2010, the premier high-energy physics collider in the world. The data collected over the last decade by high-energy physics experiments running at the Tevatron have been analyzed to make important measurements in fundamental areas such as B meson masses and flavor oscillation, searches for the Higgs boson, and supersymmetry. Collecting these data at the limits of detectability has required the Tevatron to operate reliably at high beam intensities to maximize the number of collisions to analyze. This impressive achievement has been assisted by the use of HPC resources and software provided through the SciDAC program. This paper describes the enhancements to the BeamBeam3d code to realistically simulate the Tevatron, the validation of these simulations, and the improvement in equipment reliability and personal safety achieved with the aid of simulations.

43 PARTICLE ACCELERATORS↗

Unit Commitment Considering Generation Flexibility and Environmental Constraints

This paper proposes a new framework for power system unit commitment process, which incorporates the generation flexibility requirements and environmental constraints into the existing unit commitment algorithm. The generation flexibility requirements are to address the uncertainties with large amount of intermittent resources as well as with load and traditional generators, which causes real-time balancing requirements to be variable and less predictable. The proposed flexibility requirements include capacity, ramp and ramp duration for both upward and downward balancing reserves. The environmental constraints include emission allowance for fossil fuel-based generators and ecological regulations for hydro power plants. Calculation of emission rates is formulated. Unit commitment under this new framework will be critical to the economic and reliable operation of the power grid and the minimization of its negative environmental impacts, especially when high penetration levels of intermittent resources are being approached, as required by the renewable portfolio standards in many states.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AOI.1 Application of Artificial Intelligence techniques enabling coal fired power plants the ability to achieve higher efficiency, improved availability, and increased reliability of their operations (Final Report)

During this effort, SparkCognition with support from the Electric Power Research Institute (EPRI) was tasked with applying artificial intelligence (AI) to improve the reliability, efficiency, and safety of operations at a coal-fired plant. By implementing AI techniques, like machine learning (ML), it is believed that operators can leverage existing data sources to gain more insights such as advanced warning of machine degradation. With enough lead time, a reliability engineer can take action to minimize, or even avoid, impact to production. To complete this work effort, SparkCognition developed and refined an ML-based model using sensor data for a Steam Turbine unit at a host site. The models were deployed in an online, web-based solution that allows users to visualize model outputs and supporting data. The final solution, based on SparkCognition’s proprietary software platform called SparkPredict®, was shared with EPRI who completed an online evaluation of results to determine the solution’s ability to detect actionable events.

20 FOSSIL-FUELED POWER PLANTS↗

An economic assessment of behind-the-meter photovoltaics paired with batteries on the Hawaiian Islands.

Due to natural variability and uncertainty, the ever-increasing penetration of solar generation in Hawaii presents challenges to power grid operators to maintain reliable system operation. Demand response (DR) has the potential to be a cost-effective tool for Hawaii to reach its aggressive renewable energy goals while maintaining the reliability of power grids. The Hawaii Public Utilities Commission has approved the Hawaiian Electric Company's revised portfolio of DR programs. The companies have released a grid services purchase agreement and subscribed an initial tranche of load into their DR programs. This paper presents innovative analytical methods and comprehensive economic assessment for distributed photovoltaics (PV) paired with battery energy storage systems (BESSs) for two new DR programs, including fast frequency response and capacity grid service. Optimal dispatch and sizing methods are proposed for the paired system considering different tariff schedules and PV compensation programs across five islands. It was found that while the best resource configuration and potential economic benefits vary with tariff structure, a BESS paired with PV can be optimally dispatched to generate multiple value streams simultaneously. Compensation from DR programs is an important value stream to help increase the cost-effectiveness of the integrated system.

Battery energy storage system↗