Search NASA⌕ Search

SEARCH · Search NASA

Results for “PATHOLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

The impact of demographic, clinical, genetic, and imaging variables on tau PET status

Purpose: A substantial proportion of amyloid-β (Aβ)+ patients with clinically diagnosed Alzheimer’s disease (AD) dementia and mild cognitive impairment (MCI) are tau PET–negative, while some clinically diagnosed non-AD neurodegenerative disorder (non-AD) patients or cognitively unimpaired (CU) subjects are tau PET–positive. We investigated which demographic, clinical, genetic, and imaging variables contributed to tau PET status. Methods: We included 2338 participants (430 Aβ+ AD dementia, 381 Aβ+ MCI, 370 non-AD, and 1157 CU) who underwent [ 18 F]flortaucipir ( n = 1944) or [ 18 F]RO948 ( n = 719) PET. Tau PET positivity was determined in the entorhinal cortex, temporal meta-ROI, and Braak V-VI regions using previously established cutoffs. We performed bivariate binary logistic regression models with tau PET status (positive/negative) as dependent variable and age, sex, APOE ε4, Aβ status (only in CU and non-AD analyses), MMSE, global white matter hyperintensities (WMH), and AD-signature cortical thickness as predictors. Additionally, we performed multivariable binary logistic regression models to account for all other predictors in the same model. Results: Tau PET positivity in the temporal meta-ROI was 88.6% for AD dementia, 46.5% for MCI, 9.5% for non-AD, and 6.1% for CU. Among Aβ+ participants with AD dementia and MCI, lower age, MMSE score, and AD-signature cortical thickness showed the strongest associations with tau PET positivity. In non-AD and CU participants, presence of Aβ was the strongest predictor of a positive tau PET scan. Conclusion: We identified several demographic, clinical, and neurobiological factors that are important to explain the variance in tau PET retention observed across the AD pathological continuum, non-AD neurodegenerative disorders, and cognitively unimpaired persons.

60 APPLIED LIFE SCIENCES↗

Impact of simulated reduced injected dose on the assessment of amyloid PET scans

To investigate the impact of reduced injected doses on the quantitative and qualitative assessment of the amyloid PET tracers [ 18 F]flutemetamol and [ 18 F]florbetaben. Cognitively impaired and unimpaired individuals (N = 250, 36% Aβ-positive) were included and injected with [ 18 F]flutemetamol (N = 175) or [ 18 F]florbetaben (N = 75). PET scans were acquired in list-mode (90–110 min post-injection) and reduced-dose images were simulated to generate images of 75, 50, 25, 12.5 and 5% of the original injected dose. Images were reconstructed using vendor-provided reconstruction tools and visually assessed for Aβ-pathology. SUVRs were calculated for a global cortical and three smaller regions using a cerebellar cortex reference tissue, and Centiloid was computed. Absolute and percentage differences in SUVR and CL were calculated between dose levels, and the ability to discriminate between Aβ- and Aβ + scans was evaluated using ROC analyses. Finally, intra-reader agreement between the reduced dose and 100% images was evaluated. At 5% injected dose, change in SUVR was 3.72% and 3.12%, with absolute change in Centiloid 3.35CL and 4.62CL, for [ 18 F]flutemetamol and [ 18 F]florbetaben, respectively. At 12.5% injected dose, percentage change in SUVR and absolute change in Centiloid were < 1.5%. AUCs for discriminating Aβ- from Aβ + scans were high (AUC ≥ 0.94) across dose levels, and visual assessment showed intra-reader agreement of > 80% for both tracers. This proof-of-concept study showed that for both [ 18 F]flutemetamol and [ 18 F]florbetaben, adequate quantitative and qualitative assessments can be obtained at 12.5% of the original injected dose. However, decisions to reduce the injected dose should be made considering the specific clinical or research circumstances.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictive role of PI-RADSv2 and ADC parameters in differentiating Gleason pattern 3 + 4 and 4 + 3 prostate cancer

Purpose: To compare the predictive roles of qualitative (PI-RADSv2) and quantitative assessment (ADC metrics), in differentiating Gleason pattern (GP) 3 + 4 from the more aggressive GP 4 + 3 prostate cancer (PCa) using radical prostatectomy (RP) specimen as the reference standard. Methods: We retrospectively identified treatment-naïve peripheral (PZ) and transitional zone (TZ) Gleason Score 7 PCa patients who underwent multiparametric 3T prostate MRI (DWI with b value of 0,1400 and where unavailable, 0,500) and subsequent RP from 2011 to 2015. For each lesion identified on MRI, a PI-RADSv2 score was assigned by a radiologist blinded to pathology data. A PI-RADSv2 score ≤ 3 was defined as “low risk,” a PI-RADSv2 score ≥ 4 as “high risk” for clinically significant PCa. Mean tumor ADC (ADC{sub T}), ADC of adjacent normal tissue (ADC{sub N}), and ADC{sub ratio} (ADC{sub T}/ADC{sub N}) were calculated. Stepwise regression analysis using tumor location, ADC{sub T} and ADC{sub ratio}, b value, low vs. high PI-RADSv2 score was performed to differentiate GP 3 + 4 from 4 + 3. Results: 119 out of 645 cases initially identified met eligibility requirements. 76 lesions were GP 3 + 4, 43 were 4 + 3. ADC{sub ratio} was significantly different between the two GP groups (p = 0.001). PI-RADSv2 score (“low” vs. “high”) was not significantly different between the two GP groups (p = 0.17). Regression analysis selected ADC{sub T} (p = 0.03) and ADC{sub ratio} (p = 0.0007) as best predictors to differentiate GP 4 + 3 from 3 + 4. Estimated sensitivity, specificity, and accuracy of the predictive model in differentiating GP 4 + 3 from 3 + 4 were 37, 82, and 66%, respectively. Conclusions: ADC metrics could differentiate GP 3 + 4 from 4 + 3 PCa with high specificity and moderate accuracy while PI-RADSv2, did not differentiate between these patterns.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic resonance imaging of the placenta and gravid uterus: a pictorial essay

The placenta is commonly overlooked on magnetic resonance imaging of the pregnant patient, which is frequently performed for alternative reasons such as to characterize fetal or uterine anomalies or to investigate the etiology of acute pelvic pain in pregnancy. Placental disorders have potential for significant maternal and fetal morbidity and peripartum complications if not recognized and treated in a timely manner. The radiologist must be familiar with normal placental variants and the spectrum of benign to life-threatening conditions affecting the placenta so that the Obstetrician can be promptly notified and patient management altered, if necessary. In this pictorial essay, we will describe our MR protocol for placental imaging, provide an image-rich review of the normal placenta, placental variants, and a variety of pathological conditions affecting the placenta and gravid uterus.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differentiation of hepatic abscess from metastasis on contrast-enhanced dynamic computed tomography in patients with a history of extrahepatic malignancy: emphasis on dynamic change of arterial rim enhancement

Objectives: The objective of the study is to identify computed tomography (CT) findings that differentiate hepatic abscess from hepatic metastasis in a patient with a history of extrahepatic malignancy. Materials and methods: This retrospective study included 30 patients with 93 hepatic abscesses and 40 patients with 125 hepatic metastases who had a history of extrahepatic malignancy and underwent contrast-enhanced dynamic CT with arterial phase (AP) and portal venous phase (PVP). The diagnosis of hepatic abscess and hepatic metastasis was made using pathological confirmation or clinical diagnosis. Margin, patchy parenchymal enhancement, arterial rim enhancement, dynamic change of arterial rim enhancement, size discrepancy of lesions between arterial and portal phases, bile duct dilatation, perilesional hyperemia, and perilesional low density were evaluated by two radiologists independently. Significant findings for differentiating two groups were identified at univariate and multivariate analysis with nomogram for predicting hepatic abscess. Interobserver agreement was also analyzed for each variable. Results: Multivariate analysis revealed that patchy parenchymal enhancement (P < 0.001), arterial rim enhancement persistent through PVP (P < 0.001), and perilesional hyperemia (P = 0.013) were independent significant findings to predict hepatic abscess than metastasis. Among them, arterial rim enhancement persistent through PVP showed a highest odds ratio (OR 33.73) on multivariate analysis and a highest predictor point on a nomogram for predicting hepatic abscess. When two of these three criteria were combined, 80.7% (75/93) of hepatic abscess were correctly identified, with a specificity of 85.6% (107/125). When all three criteria were satisfied, specificity was up to 100% (125/125). Conclusions: At contrast-enhanced dynamic CT, patchy parenchymal enhancement, arterial rim enhancement persistent through PVP, perilesional hyperemia, and their combinations may be reliable CT features for differentiating hepatic abscess from metastasis in patients with a history of primary extrahepatic malignancy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of perfusion CT in differentiating of pancreatic ductal adenocarcinoma from mass-forming chronic pancreatitis and characterization of isoattenuating pancreatic lesions

Purpose: Multidetector computed tomography (MDCT) is routinely used in the diagnosis of pancreatic ductal adenocarcinoma (PDAC), but it may be inadequate in some cases, especially mass-forming chronic pancreatitis (MFCP) and isoattenuating pancreatic lesions. Perfusion CT (pCT) may help resolve this problem. The aim of this study was to evaluate whether pCT could help differentiating PDAC from MFCP and in characterization of isoattenuating pancreatic lesions. Materials and methods: This prospective study included 89 cases of pancreatic lesions detected by MDCT and further analyzed with pCT. Sixty-one cases with final pathological diagnosis PDAC and 12 cases with MFCP were included from the study. Blood volume (BV), blood flow (BF), mean transit time (MTT), and permeability surface area product (PS) maps were obtained. Perfusion values obtained from the lesions and normal parenchyma were compared. Results: Compared with normal parenchyma, BV, BF, PS were lower and MTT was longer in PDAC and MFCP (p < 0.05). Compared with MFCP, BV, BF, PS were lower and MTT was longer in PDAC (p < 0.001). Compared with normal parenchyma, BV, BF, PS were lower and MTT was longer in isoattenuating lesions, (p < 0.001). Cutoff values of 7.60 mL/100 mL, 64.43 mL/100 mL/min, 28.08 mL/100 mL/min for BV, BF, PS, respectively, provided 100% sensitivity and specificity and 7.47 s for MTT provided 98.3% sensitivity, 80% specificity for distinguishing PDAC from MFCP. Conclusion: pCT is a useful technology that can be helpful in overcoming the limitations of routine MDCT in diagnosing PDAC and characterization of isoattenuating lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging in the pre-operative staging of ovarian cancer

The main prognostic factor in ovarian cancer is the stage of disease at diagnosis. The staging system in use (FIGO classification, updated in 2014) is based on the surgical-pathological findings. Although surgical staging is the gold standard in ovarian cancer, the initial patient management depends on the imaging-based pre-surgical staging assessment, in order to identify unresectable or difficult to resect disease. Radiologists need to be aware of the strengths of the available imaging modalities, as well as the imaging pitfalls. Clear understanding of pattern of disease spread and review areas are critical for accurate staging and treatment planning. The current standard of care for pre-surgical staging is CT of the thorax, abdomen, and pelvis. This allows a rapid evaluation of disease extent and is fairly accurate in identifying bulky disease but has definite limitations in assessing the extent of small volume disease and in the confirmation of certain sites of disease beyond the abdomen. Functional MRI has been reported to be superior in detecting small peritoneal deposits. PET/CT may be used as a problem-solving tool in some patients where determination remains unclear, particularly in confirmation of advanced stage beyond the abdomen.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differentiation of duodenal gastrointestinal stromal tumors from hypervascular pancreatic neuroendocrine tumors in the pancreatic head using contrast-enhanced computed tomography

Purpose: To determine useful contrast-enhanced computed tomography (CE-CT) features in differentiating duodenal gastrointestinal stromal tumors (duodenal GISTs) from hypervascular pancreatic neuroendocrine tumors in the pancreatic head (pancreatic head NETs). Methods: Seventeen patients with pathologically confirmed duodenal GISTs and 25 with pancreatic NETs underwent preoperative CE-CT. CT image analysis included tumor size, morphology, and contrast enhancement. Receiver operating characteristic curves were performed, and cutoff values were calculated to determine CT findings with high sensitivity and specificity. Results: CT imaging showed duodenal GISTs with higher frequencies of tumor central location close to the duodenum and a predominantly solid tumor type when compared with pancreatic head NETs (p < 0.05 for both). Duodenal GISTs were larger than pancreatic head NETs (3.3 ± 0.9 cm vs. 2.5 ± 1.1 cm, p = 0.03). Duodenal GISTs had significantly lower CT attenuation values (112.9 ± 17.9HU vs. 137.4 ± 32.1HU, p < 0.01) at the arterial phase and higher CT attenuation values at the delayed phase (94.3 ± 7.9HU vs. 84.9 ± 10.4HU, p < 0.01) when compared with pancreatic head NETs. A CT attenuation value of ≤ 135 HU at the arterial phase (30 s) was 76% sensitive, 94.1% specific, and 83.3% accurate for the diagnosis of duodenal GISTs, while a CT attenuation value of ≥ 89.5 HU at the delayed phase (120 s) was 93.3% sensitive, 81.8% specific, and 76.2% accurate for the diagnosis of duodenal GISTs. Conclusion: Tumor central location, size, texture, and contrast enhancement are valuable characteristics for the differentiation between duodenal GISTs and hypervascular pancreatic head NETs during preoperative examination.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characteristics of missed prostate cancer lesions on 3T multiparametric-MRI in 518 patients: based on PI-RADSv2 and using whole-mount histopathology reference

Purpose: To determine the characteristics of missed prostate cancer (PCa) lesions on 3T multiparametric-MRI (mpMRI) based on PI-RADSv2 with whole-mount histopathology (WMHP) correlation. Materials and methods: This IRB-approved, HIPAA-compliant study, included 614 consecutive men with 3T mpMRI prior to prostatectomy at a single tertiary center between 12/2009 and 4/2017. Clinical, mpMRI, and pathologic features were obtained. PI-RADSv2-based MRI detected lesions were matched with previously finalized WMHP by a genitourinary (GU) radiologist and a GU pathologist. Patients with no mpMRI detected PCa lesion, but with at least one lesion ≥ 1 cm on WMHP, were reviewed retrospectively and assigned a PI-RADSv2 score. Tumor characteristics were compared between missed and detected lesions. Result: The final cohort included 518 patients with 1085 WMHP lesions. 51.9% (563/1085) of lesions were missed on 3T mpMRI. 71.4% (402/563), 21.7% (122/563), 4.4% (25/563), and 2.5% (14/563) of the missed lesions were Gleason scores (GS) 3 + 3, 3 + 4, 4 + 3, and 8 − 10, respectively. Missed PCa lesions had significantly lower proportion of GS ≥ 7 (p < 0.001) and smaller size for overall (p < 0.001) and index subcohorts (p < 0.001), as compared to detected lesions. 34.5% (194) of overall and 71.2% (79) index missed lesions were larger than 1 cm. In 13.7% (71/518) of patients without MR detected PCa, 149 lesions were detected on WMHP, with 70 (47%) lesions ≥ 1 cm. In retrospective review of these lesions, 42.9% (30), 18.6% (13), 21.5% (15), 10% (7), and 7% (5) were PI-RADSv2 1, 2, 3, 4, and 5, respectively. Conclusion: 3T mpMRI has an excellent per patients diagnostic performance for PCa and majority of missed lesions are clinically nonsignificant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Juxtatumoral perinephric fat analysis in clear cell renal cell carcinoma

Purpose: The purpose of the study was to evaluate the feasibility of using contrast-enhanced computed tomography (CECT)-based texture analysis (CTTA) metrics to differentiate between juxtatumoral perinephric fat (JPF) surrounding low-grade (ISUP 1–2) versus high-grade (ISUP 3–4) clear cell renal cell carcinoma (ccRCC). Methods: In this IRB-approved study, we retrospectively queried the surgical database between June 2009 and April 2016 and identified 83 patients with pathologically confirmed ccRCC (low grade: n = 54, mean age = 61.5 years, 18F/35M; high grade n = 30, mean age = 61.7 years, 8F/22M) who also had pre-operative multiphase CT acquisitions. CT images were transferred to a 3D workstation, and nephrographic phase JPF regions were manually segmented. Using an in-house developed Matlab program, a CTTA panel comprising of texture metrics extracted using six different methods, histogram, 2D- and 3D-Gray-level co-occurrence matrix (GLCM) and Gray-level difference matrix (GLDM), and 2D-Fast Fourier Transform (FFT) analyses, was applied to the segmented images to assess JPF textural heterogeneity in low- versus high-grade ccRCC. Univariate analysis and receiver-operator characteristics (ROC) analysis were used to assess interclass differences in texture metrics and their prediction accuracy, respectively. Results: All methods except GLCM consistently revealed increased heterogeneity in the JPF surrounding high- versus low-grade ccRCC. FFT showed increased complexity index (p < 0.01). Histogram analysis showed increased kurtosis and positive skewness in (p < 0.03), and GLDM analysis showed decreased measure of correlation coefficient (MCC) (p < 0.04). Several of the GLCM metrics showed statistically significant (p < 0.04) textural differences between the two groups, but with no consistent trend. ROC analysis showed that MCC in GLCM analysis had an area under the curve of 0.75. Conclusions: Our study suggests that CTTA of ccRCC shows statistically significant textural differences in JPF surrounding high- versus low-grade ccRCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging findings of hemorrhagic hepatic cysts with enhancing mural nodules

Purpose: This study aimed to evaluate the clinical and radiological findings of hemorrhagic hepatic cysts with enhancing mural nodules. Methods: The radiology databases of five facilities were retrospectively searched for reports indicating hemorrhagic hepatic cysts or hepatic cystic tumors. Cases of hemorrhagic hepatic cysts with enhancing mural nodules based on pathological or radiological findings were identified and reviewed. Results: We included 14 cases (11 female and 3 male) with a mean patient age of 72.6 years. Up until the enhancing mural nodules were detected, the cysts had decreased in size in all ten cases for which radiological imaging was available for a period of > 3 years previous to detection. Dynamic contrast-enhanced CT or MRI showed focal enhancement in the early phase and progressive centrifugal enhancement in the delayed phase in all 16 mural nodules ≥ 10 mm in diameter. Thirteen of 14 MRI assessable enhancing mural nodules ≥ 10 mm in diameter showed a hypointense rim with central hyperintensity on T2-weighted imaging. All cases showed calcification of the cyst wall. In the three referred cases, {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography/CT demonstrated no intense FDG uptake in the enhancing mural nodules. In the four resected cases, histopathology of the enhancing mural nodules revealed neovascularization within an organized hematoma, including extensive dilated vessels and hemangioma-like lesions. Conclusions: Features including a decrease in cyst size, a progressive centrifugal enhancing pattern on dynamic contrast-enhanced CT or MRI, a hypointense rim with central hyperintensity on T2-weighted MRI, and cyst wall calcification may indicate a hemorrhagic hepatic cyst.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative accuracy of qualitative and quantitative 18F-FDG PET/CT analysis in detection of lymph node metastasis from anal cancer

Purpose: To compare the diagnostic performance of qualitative and quantitative 18F-FDG PET/CT in detection of regional and distant lymph node metastasis in patients with anal cancer. Methods: Between 2004 and 2017, 28 patients with anal cancer who had staging PET/CT and pathological assessment of suspicious lymph nodes were included. For qualitative analysis, positive lymph nodes were defined as uptake visually higher than the liver reference uptake. For quantitative study, lymph nodes were contoured to determine maximum standard uptake value (SUV{sub max}) and metabolic tumor volume (MTV). Receiver operating characteristic (ROC) curves were plotted to extract the optimal cut-offs and area under the curve (AUC) of SUV{sub max}, lesion to background (L/B) ratio, short axis diameter (SAD), and MTV of lymph nodes. Histopathologic analysis was a reference standard. Results: A total of 28 lymph nodes (24 inguinal, 2 external iliac, 1 internal iliac, and 1 paraaortic nodes) in 28 patients on PET/CT were included. With the qualitative visual analysis, 19 patients were categorized as positive for nodal metastasis with sensitivity, specificity, and accuracy of 85%, 75%, and 82%. The optimal SUV{sub max} and L/B ratio cut-offs were 2.6 and 1.0 with both sensitivity and specificity of 95% and 75% (AUC of SUV{sub max} = 0.893, AUC of L/B ratio = 0.912). Using the best cut-off of 1.6 cm for SAD and 3.65 cm{sup 3} for MTV, both sensitivity and specificity were 80% and 100% (AUC of SAD = 0.950, AUC of MTV = 0.931). Conclusions: SUV{sub max} optimization may be helpful in enhancing the diagnostic accuracy of 18F-FDG PET/CT in nodal staging patients with anal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analyzing the post-contrast attenuation of the esophageal wall on routine contrast-enhanced MDCT examination can improve the diagnostic accuracy in response evaluation of the squamous cell esophageal carcinoma to neoadjuvant chemoradiotherapy in comparison with the esophageal wall thickness

Purpose: To evaluate the accuracy of the multidetector computed tomography (MDCT) in the response evaluation of the esophageal squamous cell carcinoma (ESCC) to neoadjuvant chemoradiotherapy (nCRT) by analyzing the thickness and post-contrast attenuation of the esophageal wall after the nCRT. Methods: Contrast-enhanced (CE)-MDCT examinations in portal venous phase of one hundred patients with locally advanced ESCC who received nCRT and underwent esophageal resection and histopathology assessment of tumor regression grade (TRG) were retrospectively analyzed by measuring the maximal thickness and mean density of the esophageal wall in the segment involved by tumor and visually searching for hyperdense foci within it. Diagnostic performance was evaluated using the ROC analysis. Results: Average attenuation of the esophageal wall had stronger diagnostic performance for predicting pathologic complete regression (pCR) (AUC = 0.994; p < 0.001) in relation to maximal esophageal wall thickness (AUC = 0.731; p < 0.001). Maximal esophageal wall thickness ≤ 9 mm and average attenuation of the esophageal wall ≤ 64 HU predicted pCR with the sensitivity, specificity, and overall accuracy of 62.5%, 77.9%, and 73%, and 96.9%, 98.5%, and 98%, respectively. Combination of both cutoff values enabled correct assessment of pCR with the 100% accuracy. Visual detection of the hyperdense focus within the esophageal wall predicted pCR with the sensitivity, specificity, and overall accuracy values of 100%, 94.1%, and 96%, respectively. Conclusion: Visual analysis and measurement of post-contrast attenuation of the esophageal wall after the nCRT can improve diagnostic accuracy of MDCT in the response evaluation of the ESCC to nCRT in comparison with measuring the esophageal wall thickness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR findings of uterine PEComa in patients with tuberous sclerosis: report of two cases

Tuberous sclerosis complex (TSC), a rare autosomal dominant neurocutaneous disorder, is characterized by the presence of benign congenital tumors in multiple organs. Neoplasms with perivascular epithelioid cell differentiation (PEComas), including angiomyolipoma (AML) and lymphangioleiomyomatosis (LAM), can occur in association with TSC. This report describes two cases of uterine PEComas presenting characteristic MR imaging features reflecting pathological findings. From MR images, both cases showed single or multiple large, irregularly shaped or lobulated hemorrhagic lesions within the myometrium. They differed from typical adenomyotic cysts in their large size and irregular margins. Histopathologic analysis revealed that the hemorrhage was caused by adenomyosis and tumor cells that proliferated in surrounding stroma of the hemorrhagic lesions, compatible with PEComas. Microscopic observation revealed an infiltrative growth pattern of PEComas, with small nodules formed. The tumor lesions, however, were difficult to detect on MR images. The myometrium showed normal appearance on both T1-weighted and T2-weighted images in both cases. We speculate that PEComas may infiltrate extensively into the myometrium even when the myometrium shows almost normal radiologic appearance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT and MRI features of undifferentiated carcinomas with osteoclast-like giant cells of the pancreas: a case series

Purpose: The purpose of this case series was to describe computed tomography (CT) and magnetic resonance imaging (MRI) features of undifferentiated carcinoma with osteoclast-like giant cells of the pancreas. Methods: Institutional ethics review board approval was obtained, and informed consent was waived for this case series. We reviewed CT and MRI of patients with pathologically confirmed undifferentiated carcinoma with osteoclast-like giant cells of the pancreas found in the medical records of our hospital between 2006 and 2016. Results: Seven patients (3 males and 4 females; age, 59–82 years (mean, 71)) with confirmation by surgical resection (n = 3) or biopsy (n = 4) were identified. They underwent CT (n = 7) and MRI (n = 6). The tumors 26–83 mm in diameter (mean, 44 mm) were located in the head (n = 4) or body (n = 3) of the pancreas. They were demonstrated as lower attenuation areas relative to the adjacent pancreas on CT images obtained in both pancreatic and portal vein phases (n = 7) with a well-defined smooth margin (n = 5). They were demonstrated as hypointense areas relative to the pancreas on T2-weighted images (n = 4) and T2*-weighted images (n = 4) and diffusion-weighted images (n = 3). They contained hemosiderin deposits on histology (n = 7). Conclusions: Undifferentiated carcinoma with osteoclast-like giant cells of the pancreas might be present as low attenuation areas with a well-defined smooth margin on CT images obtained in pancreatic and portal vein phases, and hypointense areas on T2-, T2*-, and diffusion-weighted images caused by hemosiderin deposits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differentiation of aggressive from non-aggressive pancreatic solid pseudopapillary neoplasms using computed tomography

Purposes: Microscopic aggressive behaviors may be related with the prognosis of solid pseudopapillary neoplasms (SPNs). In this study, we investigate computed tomography (CT) features and differential diagnosis of aggressive and non-aggressive SPNs in pancreas. Materials and methods: 122 patients with pathologically proven SPNs in pancreas were included. Patients’ age, tumor site, texture, shape, margins, exophytic growth, capsule, calcification, hemorrhage, pancreatic duct dilatation or pancreatic parenchyma atrophy, peripancreatic infiltration or metastases, vascular encasement, and enhancement pattern were assessed. The diagnostic accuracy was analyzed by using the receiver operating characteristic curve (ROC). Results: There were 30 aggressive SPNs and 92 non-aggressive SPNs. Aggressive SPNs showed significantly higher frequencies of an ill-defined margin, patient age > 40.5 years, and tumor size < 42.1 mm, but lower frequencies of complete capsule, hemorrhage compared with non-aggressive SPNs (p < 0.05). Lack of complete capsule and age > 40.5 years were independent risk factors of aggressive SPNs (odd ratio 7.08 and 3.1, respectively). When we applied the two predictors in the logistic regression model, the area under the curve (AUC) was 0.77 with sensitivity of 86.7% and specificity of 55.4%. Conclusion: Size less than 42.1 mm, lack of complete capsule, ill-defined, and absent bleeding are useful CT imaging features for predicating aggressive SPNs. Patient age > 40.5 years and lack of complete capsule showed acceptable diagnostic performance for discriminating aggressive from non-aggressive SPNs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

110 Patients with adenosquamous carcinomas of the pancreas (PASC): imaging differentiation of small (≤ 3 cm) versus large (> 3 cm) tumors

Objective: This study examined radiological imaging features of small (≤ 3 cm) and large (> 3 cm) adenosquamous carcinomas of the pancreas (PASC) lesions to better understand the morphology of these lesions. Methods: Images from 110 patients with pathologically proven PASC (80 males and 30 females, mean age: 62.6 years) were retrospectively reviewed. Two radiologists analyzed images and reached a consensus regarding the following features: location, shape, margins, presence of solid and necrotic components, rim enhancement, density/intensity during the portal venous phase, invasion of surrounding organs, vascular invasion, venous tumor thrombus formation, and enlarged lymph nodes. Differences in the imaging features between the two groups were evaluated with the Chi-square test or Fisher’s exact test. Results: There were 41 small PASC lesions (mean age: 60.59 years) and 69 large PASC lesions (63.74 years). Statistical analysis demonstrated significant differences in the location, shape, adjacent organ and vessel invasion, and venous tumor thrombus formation (P < 0.05). Small PASC lesions were more frequently detected in the pancreatic head and had an ovoid shape. There was no significant difference in the presence of solid and necrotic components (P = 0.090), including approximately 3/4 of the lesions with necrosis and 1/4 purely solid lesions, enlarged lymph nodes (P = 0.068) and other features. Conclusion: Regardless of the tumor size, 75% of PASC lesions present with central necrosis while 25% are purely solid. Small PASC lesions can be associated with lymph node metastasis at a relatively early stage. Large PASC lesions are likely to invade adjacent tissues and be associated with venous tumor thrombus formation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uterine carcinosarcoma: a primer for radiologists

Objective: To provide a modern overview for radiologists of the unique radiological, pathological, and clinical features of uterine carcinosarcoma (UCS). Results: UCS is a unique gynecological malignancy that continues to present diagnostic and therapeutic challenges to the field of oncology. The classification and clinical understanding of this malignancy have evolved in recent years, yielding a modern conceptualization of a neoplastic entity that has been well studied but incompletely understood. As UCS causes a significant proportion of deaths secondary to uterine cancer, developing a familiarity with the imaging and clinical features of this entity is critical. In addition to summarizing the modern understanding of this tumor variant, an overview of the common imaging features of UCS will be presented. The role of radiological staging, imaging findings on presentation and follow-up imaging, and modern treatment paradigms will be discussed. Lastly, the current treatment paradigms and surveillance recommendations for UCS will be summarized. Conclusion: Knowledge of the modern understanding of uterine carcinosarcoma, including its relevant imaging and clinical features, is critical for radiologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗