Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗

Determination of tire cross-sectional geometric characteristics from a digitally scanned image

A semi-automated procedure is described for the accurate determination of geometrical characteristics using a scanned image of the tire cross-section. The procedure can be useful for cases when CAD drawings are not available or when a description of the actual cured tire is desired. Curves representing the perimeter of the tire cross-section are determined by an edge tracing scheme, and the plyline and cord-end positions are determined by locations of color intensities. The procedure provides an accurate description of the perimeter of the tire cross-section and the locations of plylines and cord-ends. The position, normals, and curvatures of the cross-sectional surface are included in this description. The locations of the plylines provide the necessary information for determining the ply thicknesses and relative position to a reference surface. Finally, the locations of the cord-ends provide a means to calculate the cord-ends per inch (epi). Menu driven software has been developed to facilitate the procedure using the commercial code, PV-Wave by Visual Numerics, Inc., to display the images. From a single user interface, separate modules are executed for image enhancement, curve fitting the edge trace of the cross-sectional perimeter, and determining the plyline and cord-end locations. The code can run on SUN or SGI workstations and requires the use of a mouse to specify options or identify items on the scanned image.

Danielson, Kent T.↗

FY 2018 DuraMAT Annual Report

This report summarizes the progress and successes of the Durable Module Materials Consortium in FY 2018.

14 SOLAR ENERGY↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Previous papers and presentations have focused on the development of the test method using a benchtop prototype. This presentation covers the early results of C-AST aging of static and dynamic specimens.

balance of systems↗

A Critical Review of the Circular Economy for Lithium-Ion Batteries and Photovoltaic Modules: Status, Challenges, and Opportunities

To meet net-zero emissions and cost targets for power production, recent analysis indicates that photovoltaic (PV) capacity in the United States could exceed 1 TW by 2050 alongside comparable levels of energy storage capacity, mostly from batteries. For comparison, the total U.S. utility-scale power capacity from all energy sources in 2020 was 1.2 TW (EIA 2022), of which solar satisfied approximately 3% (DOE 2021). With such massive scales of deployment, questions have arisen regarding issues of material supply for manufacturing, end-of-life management of technologies, environmental impacts across the life cycle, and economic costs to both individual consumers and society at large. A set of solutions to address these issues center on the development of a circular economy - shifting from a take-make-waste linear economic model to one that retains the value of materials and products as long as possible, recovering materials at end of life to recirculate back into the economy. With limited global experience, scholars and practitioners have begun to investigate circular economy pathways, focusing on applying novel technologies and analytical methods to fast-growing sectors like renewable energy. This critical review aims to synthesize the growing literature to identify key insights, gaps, and opportunities for research and implementation of a circular economy for two of the leading technologies that enable the transition to a renewable energy economy: solar PV and lithium-ion batteries (LIBs). We apply state-of-the-science systematic literature review procedures to critically analyze over 3,000 publications on the circular economy of solar PV and LIBs, categorizing those that pass a series of objective screens in ways that can illuminate the current state of the art, highlight existing impediments to a circular economy, and recommend future technological and analytical research. We conclude that while neither PV nor LIB industries have reached a circular economy, they are both on a path towards increased circularity. Based on our assessment of the state of current literature and scientific understanding, we recommend research move beyond its prior emphasis on recycling technology development to more comprehensively investigate other CE strategies, more holistically consider economic, environmental and policy aspects of CE strategies, increase leveraging of digital information systems that can support acceleration towards a CE, and to continue to study CE-related aspects of LIB and PV markets.

circular economy↗

pvplr-python: Python package implementation of PVplr for Performance Loss Rate (PLR) analysis

Due to software fragmentation, PV system modeling teams can be limited to language specific packages, preventing cross-sectional analysis of different modeling techniques and workflows. To this end, PVplr, a popular PV performance modeling R software package, has been ported to the Python programming language. To verify and test the robustness of the port, NSRDB data has been used to simulated PV installations at native resolution (~2 million Sites), with a variety of degradation rates, degradation patterns, and modules. Performance Ratios were calculated using the ported functions from pvplr-python and compared against Rdtools YoY values. Due to the complicated nature of degradation, a new metric has been proposed to quantify the performance loss of a system. The cumulative production loss, is the total amount of energy lost due to the degrading performance of the system. Cumulative production loss alleviates the problems with fitting linear functions to non-linear degradation. Cumulative Production loss was shown to better estimate the total lost revenue for non-linear degradation patterns. $XbX + UTC$ was found to most accurately predict the total lost revenue in simulated systems.

Kumar, Suraj↗

Valuable Data Provided by PASP Plus Flight Experiment After 1 Year in Orbit

Successfully launched on August 3, 1994, the Photovoltaic Array Space Power Plus Diagnostics (PASP Plus) flight experiment is a joint Air Force Phillips Laboratory/NASA Lewis Research Center program designed to test a variety of new and existing photovoltaic (PV) cell and array technologies within the space environment. The experiment consists of 12 different experimental photovoltaic modules, along with numerous diagnostic instruments that measure the space environment and interactions between the experimental modules and that environment. Power Technology Division personnel at Lewis, who had the primary responsibility for integrating the individual photovoltaic module experiments, continue to analyze and interpret the current-voltage characteristics and environmental effects data received back from the spacecraft. The major goals of the experiment included determining the long-term performance of the photovoltaic modules within a high-radiation environment (PASP Plus was launched into an elliptical, high-radiation orbit) and measuring the interactions between the experimental modules and the space plasma when the modules were biased at high positive and negative voltages. Understanding array interactions within the space plasma is critical to spacecraft power system operations and important to providing higher bus voltage designs in the future.

Source record↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for C-AST. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed immediately once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure occurring in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy). Chemical composition analysis included: energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing: Preprint

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy).

balance of systems↗

PV Performance Modeling - Data and Resources

The Photovoltaic (PV) Performance Modeling Collaborative (PVPMC) organized a blind PV performance modeling intercomparison to allow PV modelers to blindly test their models and modeling ability against real system data. Measured weather and irradiance data were provided along with detailed descriptions of PV systems from two locations (Albuquerque, New Mexico, USA and Roskilde, Denmark). Participants were asked to simulate the plane-of-array irradiance, module temperature, and DC power output from six systems and submit their results to Sandia for processing. This dataset includes seven MS-Excel sheets with instructions, notes and all necessary data (weather, irradiance, temperature, power) used for the data analysis of the blind modeling comparison. The hourly data represent six different systems from Albuquerque, NM and Roskilde, Denmark over a period of one year. These data are useful for PV performance model validation studies.

14 SOLAR ENERGY↗

III-Vs at Scale: A PV Manufacturing Cost Analysis of the Thin Film Vapor-Liquid-Solid Growth Mode

The authors present a manufacturing cost analysis for producing thin-film indium phosphide modules by combining a novel thin-film vapor-liquid-solid (TF-VLS) growth process with a standard monolithic module platform. The example cell structure is ITO/n-TiO2/p-InP/Mo. For a benchmark scenario of 12% efficient modules, the module cost is estimated to be $0.66/W(DC) and the module cost is calculated to be around $0.36/W(DC) at a long-term potential efficiency of 24%. The manufacturing cost for the TF-VLS growth portion is estimated to be ~$23/m2, a significant reduction compared with traditional metalorganic chemical vapor deposition. The analysis here suggests the TF-VLS growth mode could enable lower-cost, high-efficiency III-V photovoltaics compared with manufacturing methods used today and open up possibilities for other optoelectronic applications as well.

14 SOLAR ENERGY↗

Physics-Based Method for Generating Fully Synthetic IV Curve Training Datasets for Machine Learning Classification of PV Failures

Classification machine learning models require high-quality labeled datasets for training. Among the most useful datasets for photovoltaic array fault detection and diagnosis are module or string current-voltage (IV) curves. Unfortunately, such datasets are rarely collected due to the cost of high fidelity monitoring, and the data that is available is generally not ideal, often consisting of unbalanced classes, noisy data due to environmental conditions, and few samples. In this paper, we propose an alternate approach that utilizes physics-based simulations of string-level IV curves as a fully synthetic training corpus that is independent of the test dataset. In our example, the training corpus consists of baseline (no fault), partial soiling, and cell crack system modes. The training corpus is used to train a 1D convolutional neural network (CNN) for failure classification. The approach is validated by comparing the model’s ability to classify failures detected on a real, measured IV curve testing corpus obtained from laboratory and field experiments. Results obtained using a fully synthetic training dataset achieve identical accuracy to those obtained with use of a measured training dataset. When evaluating the measured data’s test split, a 100% accuracy was found both when using simulations or measured data as the training corpus. When evaluating all of the measured data, a 96% accuracy was found when using a fully synthetic training dataset. The use of physics-based modeling results as a training corpus for failure detection and classification has many advantages for implementation as each PV system is configured differently, and it would be nearly impossible to train using labeled measured data.

Hopwood, Michael W. (ORCID:0000000161901767)↗

Follow-Up from the Photovoltaic Reliability Workshop (PVRW): Cost Modeling Capabilities to Evaluate Trends in PV Technologies

NREL's Solar and Storage Techno-Economic Analysis (TEA) team reviews live polling results from the Photovoltaic Reliability Workshop (PVRW) related to module technology trends believed to have the greatest reliability impacts. Then, the team reviews the publicly available tools and inputs necessary for evaluating reliability tradeoffs between initial module and system costs, degradation profiles, and levelized cost of energy (LCOE). These tools include the online Detailed Cost Analysis Models (DCAM) and the DuraMAT LCOE calculator.

cost modeling↗

The 2020 photovoltaic technologies roadmap

Over the past decade, the global cumulative installed photovoltaic (PV) capacity has grown exponentially, reaching 591 GW in 2019. Rapid progress was driven in large part by improvements in solar cell and module efficiencies, reduction in manufacturing costs and the realization of levelized costs of electricity that are now generally less than other energy sources and approaching similar costs with storage included. Given this success, it is a particularly fitting time to assess the state of the photovoltaics field and the technology milestones that must be achieved to maximize future impact and forward momentum. This roadmap outlines the critical areas of development in all of the major PV conversion technologies, advances needed to enable terawatt-scale PV installation, and cross-cutting topics on reliability, characterization, and applications. Each perspective provides a status update, summarizes the limiting immediate and long-term technical challenges and highlights breakthroughs that are needed to address them. In total, this roadmap is intended to guide researchers, funding agencies and industry in identifying the areas of development that will have the most impact on PV technology in the upcoming years.

14 SOLAR ENERGY↗

Solar Living House Final Technical Report

The Solar Living House is a high-performance solar-powered dwelling designed by a team of faculty and students from the University of Florida, in collaboration with Santa Fe College, the National University of Singapore, and Alachua Habitat for Humanity. The project was designed in accordance with the Solar Decathlon 2015, a research, design, education, and outreach program developed by the U.S. Department of Energy (DOE). The Solar Living House is fundamentally a house for living, centered on people and the activities of daily life while quietly introducing advanced design, construction, and engineering technologies. The 993 square-foot two-bedroom one-bath home was designed to embrace and frame an exterior courtyard space. This courtyard acts as an extension of the interior living spaces, maximizing the spatial potentials of a modest building footprint and introducing natural light into the primary living spaces of the house. Research Outcomes: The Solar Living House advances work on high-performance buildings through three principal technological innovations: wet/dry modular construction, a building automation system, and solar dehumidification systems. Wet / Dry Modular Construction: The house is designed as a series of five modules, including one that is designated as the “wet core.” The wet core consolidates the mechanical systems and bathroom into a single module to reduce plumbing runs, efficiency losses, and on-site construction time. The other four modules are designed to eliminate interior load bearing walls to allow for maximum flexibility in the reconfiguring of the space over time. The modules are designed to meet the structural challenges of both Florida’s hurricanes and California’s earthquakes. Building Automation System: The house is equipped with an integrated building automation system, allowing the houses environmental systems, lights, security systems, and smoke detectors to be programmed, monitored, and controlled through any mobile or computing device. These systems allow for more precise calibrations of temperature/humidity/lighting to correspond with user needs and preferences, minimizing energy losses with economical night- or day-time setbacks. Solar Dehumidification System: The most significant technological innovation in the Solar Living House is the solar thermal dehumidification system. This system generates hot water through two rooftop-mounted evacuated tube solar thermal collectors. The hot water is used to continually dry a regenerative solid desiccant material, typically white silica gel. The solid desiccant is used to adsorb moisture and humidity from the air without additional mechanical cooling. This strategy allows humidity to be modulated independently of air temperature, providing greater thermal comfort and reducing the opportunity for the growth of mold spores within the house while also reducing the overall energy consumption of the HVAC system. Economic Feasibility: The team set aggressive goals for affordability, targeting a construction cost of $138,710. An independent professional cost estimator determined the overall project costs, as designed, would be $333,799, or $336.15 per square foot of finished floor area. This is more than 2.4 times the target construction cost. By comparison, the average construction cost for a home in the United States in 2015 was $289,415, or $103.29 per square foot of finished floor area. Following work on the Solar Living House, team leaders incorporated many of its objectives into a net-zero energy home on a site in Gainesville, Florida. This site-built home avoided many of the constraints and complications of modular construction necessitated by the Solar Decathlon, allowing it to be built for a much more modest budget. This two-bedroom two bath 1,800 square foot home was constructed for $135.39 per square foot, including active photovoltaic solar systems, careful attention to continuous air barriers, increased insulation levels, and permanent site constructions. This project suggest that high-performance buildings can be realized for more modest budgets. Public Benefits: Work on the Solar Living House and Solar Decathlon 2015 offered our student team unparalleled learning opportunities. Because of the duration of the project, a number of students participated at different points in their education, from first year undergraduates all the way through to advanced graduate students. The opportunity for collaboration with students and faculty from the National University of Singapore was also extraordinary, allowing for a sharing of technical knowledge and cultural exchange. The wider public has benefited from this work as its findings have been shared through public presentations and publications. It serves as a useful stepping stone along the path towards affordable, high-performance buildings.

14 SOLAR ENERGY↗

Solar Industry Update (Q1/Q2 FY2020) [Slides]

Each quarter, the National Renewable Energy Laboratory (NREL) conducts the Quarterly Solar Industry Update, a presentation of technical trends within the solar industry, to the solar office staff. Each presentation focuses on global and U.S. supply and demand, module and system price, investment trends and business models, and updates on U.S. government programs supporting the solar industry.

14 SOLAR ENERGY↗

Comparative Analysis of Rear Irradiance Modeling Methods for Bifacial PV Systems on Single-Axis Trackers Under Varying Albedo Conditions

This study compares three rear-side irradiance modeling methods for bifacial PV systems on single-axis trackers: (i) the 2D View Factor (VF) model in PVsyst(R), (ii) the open-source PVFactors VF model, and (iii) the Ray Tracing (RT) technique using bifacial_radiance. Simulations were benchmarked against field measurements from a pilot PV plant with rear-side sensors at the torque tube height. Results show that all models underestimated the non-uniformity of rear irradiance along the module length and overestimated the total rear irradiance incident on the module. However, since bifacial gain represents only a fraction of the system's total energy, the resulting energy yield differences among methods remained within +- 2 % of measured values, which is typical for such simulations. While the overall energy impact is limited, this study characterizes the specific limitations of each modeling approach, supporting further improvements in bifacial PV performance assessment methods.

14 SOLAR ENERGY↗