Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Multiresolution Localization with Temporal Scanning for Super-Resolution Diffuse Optical Imaging of Fluorescence

A super-resolution optical imaging method is introduced that relies on the distinct temporal information associated with each fluorescent optical reporter to determine its spatial position to high precision with measurements of heavily scattered light. This multiple-emitter localization approach uses a diffusion equation forward model in a cost function, and has the potential to achieve micron-scale spatial resolution through centimeters of tissue. Utilizing some degree of temporal separation for the reporter emissions, position and emission strength are determined using a computationally efficient time stripping multiresolution algorithm. The method circumvents the spatial resolution challenges faced by earlier optical imaging approaches using a diffusion equation forward model, and is promising for in vivo applications. For example, in principle, the approach could be used to localize individual neurons firing throughout a rodent brain, enabling direct imaging of neural network activity.

42 ENGINEERING↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 09: Impact of the distance of reflective markers from linac isocenter on the positional accuracy of an infrared tracking system

Purpose: The HexaPOD™ six degree of freedom couchtop is equipped with an optical tracking system, consisting of a stereoscopic camera and a reference frame (RF) carrying infrared reflective markers. The manufacturer recommends placing the RF within 50 cm from linac isocenter (ISO), which is a serious limitation since the RF does not fit around the shoulders of most brain patients. This study quantifies the impact of extended RF distances from ISO on positional accuracy. Methods: An in-house tool with an estimated resolution of 0.3 mm and 0.1° was used. It is a large cube and a mathematical model of HexaPOD motion to determine the intersection of room lasers with the ruled cube edges. Combinations of translations (±1 and ±3 cm) and rotations (±2.5°) were executed on two HexaPOD couchtops for multiple RF distances from ISO (35 to 77 cm). For each combination, ten laser readings were fed into a least squares algorithm to determine the executed translations and rotations while minimizing operator reading errors. Results: The usable tracking volume is up to an RF distance of 82 cm from ISO. Positional accuracy of the HexaPOD/iGuide system is 0.6 mm and 0.1° (95% confidence). Positional accuracy variations versus RF distance from ISO are statistically insignificant (p = 0.05). Our results generally confirm recent internal estimates by the manufacturer (for future release). Conclusions: RF distances up to 77 cm from ISO are clinically acceptable, provided performing a patient safety study with a verification scan.

60 APPLIED LIFE SCIENCES↗

Automated Extraction of Absorption Bands from Reflectance Special

A multiple high order derivative spectroscopy technique has been developed for deriving wavelength positions, half widths, and heights of absorption bands in reflectance spectra. The technique is applicable to laboratory spectra as well as medium resolution (100-200/cm) telescope or spacecraft spectra with moderate (few percent) noise. The technique permits absorption band positions to be detected with an accuracy of better than 3%, and often better than 1%. The high complexity of radiative transfer processes in diffusely reflected spectra can complicate the determination of absorption band positions. Continuum reflections, random illumination geometries within the material, phase angle effects, composite overlapping bands, and calibration uncertainties can shift apparent band positions by 20% from their actual positions or mask them beyond detection. Using multiple high order derivative analysis, effects of scattering continua, phase angle, and calibration (smooth features) are suppressed. Inflection points that characterize the positions and half widths of constituent bands are enhanced by the process and directly detected with relatively high sensitivity.

Huguenin, R. L.↗

High-Resolution IR Absorption Spectroscopy of Polycyclic Aromatic Hydrocarbons in the 3-micrometers Region: Role of Periphery

In this work we report on high-resolution IR absorption studies that provide a detailed view on how the peripheral structure of irregular polycyclic aromatic hydrocarbons (PAHs) affects the shape and position of their 3-micrometers absorption band. To this purpose we present mass-selected, high-resolution absorption spectra of cold and isolated phenanthrene, pyrene, benz[a]antracene, chrysene, triphenylene, and perylene molecules in the 2950-3150 per cm range. The experimental spectra are compared with standard harmonic calculations, and anharmonic calculations using a modified version of the SPECTRO program that incorporates a Fermi resonance treatment utilizing intensity redistribution. We show that the 3-micrometers region is dominated by the effects of anharmonicity, resulting in many more bands than would have been expected in a purely harmonic approximation. Importantly, we find that anharmonic spectra as calculated by SPECTRO are in good agreement with the experimental spectra. Together with previously reported high-resolution spectra of linear acenes, the present spectra provide us with an extensive dataset of spectra of PAHs with a varying number of aromatic rings, with geometries that range from open to highly-condensed structures, and featuring CH groups in all possible edge configurations. We discuss the astrophysical implications of the comparison of these spectra on the interpretation of the appearance of the aromatic infrared 3-micrometers band, and on features such as the two-component emission character of this band and the 3-micrometers emission plateau.

techniques: spectroscopic↗

Fast, Low Noise Photodetectors for Nuclear Physics

The overall goal of the Phase-II project was to construct and evaluate high performance SSPM technology for nuclear physics experiments. To achieve this overall objective, we first undertook optimization of the SSPM technology. This effort involved further enhancement of the optical quantum efficiency as well as the geometric efficiency (or fill-factor) of the SSPMs, which resulted in improvement of the photodetection efficiency of the SSPMs. Important SSPM parameters such as gain, dark count-rate, cross-talk, temporal response, after-pulsing, quantum efficiency and photodetection efficiency were evaluated for the optimized devices and these parameters were compared with those for Phase-I prototypes. Large area SSPMs (1 to 2 cm 2 ) were built using optimal design parameters. Noise analysis of large area SSPMs was performed. Upon coupling SSPMs to various scintillators (LSO/LYSO, LaBr 3 :Ce, NaI:Tl, LuAG:Ce etc.), energy resolution studies were carried. Timing resolution was also be measured with SSPMs coupled to fast scintillators (such as LaBr 3 :Ce, BaF 2 , LuAG:Ce, plastic and LSO/LYSO) using 511-keV gamma-rays ( 22 Na source). Multi-element SSPM arrays (6 x 6 format with ~1.5 x 1.5 mm 2 elements) were also designed and built using the CMOS process. These SSPM arrays were packaged and appropriate readout electronics was assembled. These SSPM arrays were operated with individual readout of each SSPM element. Large area (~1 cm 2 ) micro-pixel level PS-SSPMs with active and passive components to enable on-chip charge sharing for position sensing were also designed and built. Spatial, energy and timing resolution studies were conducted with the multi-element SSPM arrays as well as PS-SSPMs coupled to segmented scintillation arrays.

99 GENERAL AND MISCELLANEOUS↗

The New Position Sensitive Triple Cluster Detector For AGATA

The first triple cluster detector was successfully assembled for the next generation high-resolution gamma-ray spectrometer: the Advanced Gamma Tracking Array AGATA. The core part of the detector consists of three encapsulated, 36-fold segmented, high-purity germanium detectors (HPGe) which are operated in a common cryostat. All 111 energy channels are equipped with cold FETs. They provide best energy resolution of core and segment signals. The observable energy range of the Ge detectors was extended up to 100 MeV by applying a time over threshold technique with the newly developed AGATA preamplifiers. Energy resolution for high energetic {gamma}-rays above 10 MeV is measured to be comparable with values obtained with the standard pulse height technique. Detailed cross-talk investigations were performed in order to improve position dependent pulse shape information. For the Ge detectors and its analog preamplifier circuitry a low cross-talk level was determined which compares well with the expected calculated contributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sonoluminescence Bubble Measurements using Vision-Based Algorithms

Vision-based measurement methods were used to measure bubble sizes in this sonoluminescence experiment. Bubble imaging was accomplished by placing the bubble between a bright light source and a microscope-CCD camera system. A collimated light-emitting diode was operated in a pulsed model with an adjustable time delay with respect to the piezo-electric transducer drive signal. The light-emitting diode produced a bubble shadowgraph consisting of a multiple exposure made by numerous light pulses imaged onto a charge-couple device camera. Each image was transferred from the camera to a computer-controlled machine vision system via a frame grabber. The frame grabber was equipped with on-board memory to accomodate sequential image buffering while images were transferred to the host processor and analyzed. This configuration allowed the host computer to perform diameter measurements, centroid position measurements and shape estimation in "real-time" as the next image was being acquired. Bubble size measurement accuracy with an uncertainty of 3 microns was achieved using standard lenses and machine vision algorithms. Bubble centroid position accuracy was also within the 3 micron tolerance of the vision system. This uncertainty estimation accounted for the optical spatial resolution, digitization errors and the edge detection algorithm accuracy. The vision algorithms include camera calibration, thresholding, edge detection, edge position determination, distance between two edges computations and centroid position computations.

Hall, Nancy R.↗

Nucleotide-binding flexibility in ultrahigh-resolution structures of the SRP GTPase Ffh

Two structures of the nucleotide-bound NG domain of Ffh, the GTPase subunit of the bacterial signal recognition particle (SRP), have been determined at ultrahigh resolution in similar crystal forms. One is GDP-bound and one is GMPPCP-bound. The asymmetric unit of each structure contains two protein monomers, each of which exhibits differences in nucleotide-binding conformation and occupancy. The GDP-bound Ffh NG exhibits two binding conformations in one monomer but not the other and the GMPPCP-bound protein exhibits full occupancy of the nucleotide in one monomer but only partial occupancy in the other. Thus, under the same solution conditions, each crystal reveals multiple binding states that suggest that even when nucleotide is bound its position in the Ffh NG active site is dynamic. Some differences in the positioning of the bound nucleotide may arise from differences in the crystal-packing environment and specific factors that have been identified include the relative positions of the N and G domains, small conformational changes in the P-loop, the positions of waters buried within the active site and shifts in the closing loop that packs against the guanine base. However, 'loose' binding may have biological significance in promoting facile nucleotide exchange and providing a mechanism for priming the SRP GTPase prior to its activation in its complex with the SRP receptor.

59 BASIC BIOLOGICAL SCIENCES↗

Segmented YSO scintillation detectors as a new β -implant detection tool for decay spectroscopy in fragmentation facilities

A newly developed segmented YSO scintillator detector was implemented for the first time at the RI-beam Factory at RIKEN Nishina Center as an implantation-decay counter. The results from the experiment demonstrate that the detector is a viable alternative to conventional silicon-strip detectors with its good timing resolution and high detection efficiency for β particles. A Position-Sensitive Photo-Multiplier Tube (PSPMT) is coupled with a 48 × 48 segmented YSO crystal. To demonstrate its capabilities, a known short-lived isomer in 76 Ni and the β decay of 74 Co were measured by implanting those ions into the YSO detector. The half-lives and γ-rays observed in this work are consistent with the known values. The β -ray detection efficiency is more than 80 % for the decay of 74 Co.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Targeting Human Central Nervous System Protein Kinases: An Isoform Selective p38αMAPK Inhibitor That Attenuates Disease Progression in Alzheimer’s Disease Mouse Models

The first kinase inhibitor drug approval in 2001 initiated a remarkable decade of tyrosine kinase inhibitor drugs for oncology indications, but a void exists for serine/threonine protein kinase inhibitor drugs and central nervous system indications. Stress kinases are of special interest in neurological and neuropsychiatric disorders due to their involvement in synaptic dysfunction and complex disease susceptibility. Clinical and preclinical evidence implicates the stress related kinase p38αMAPK as a potential neurotherapeutic target, but isoform selective p38αMAPK inhibitor candidates are lacking and the mixed kinase inhibitor drugs that are promising in peripheral tissue disease indications have limitations for neurologic indications. Therefore, pursuit of the neurotherapeutic hypothesis requires kinase isoform selective inhibitors with appropriate neuropharmacology features. Synaptic dysfunction disorders offer a potential for enhanced pharmacological efficacy due to stress-induced activation of p38αMAPK in both neurons and glia, the interacting cellular components of the synaptic pathophysiological axis to be modulated. We report a novel isoform selective p38αMAPK inhibitor, MW01-18-150SRM (= MW150), that is efficacious in suppression of hippocampal-dependent associative and spatial memory deficits in two distinct synaptic dysfunction mouse models. A synthetic scheme for biocompatible product and positive outcomes from pharmacological screens are presented. The high-resolution crystallographic structure of the p38αMAPK:MW150 complex documents active site binding, reveals a potential low energy conformation of the bound inhibitor, and suggests a structural explanation for MW150’s exquisite target selectivity. As far as we are aware, MW150 is without precedent as an isoform selective p38MAPK inhibitor or as a kinase inhibitor capable of modulating in vivo stress related behavior

59 BASIC BIOLOGICAL SCIENCES↗

Feasibility study of high-resolution coherent diffraction microscopy using synchrotron x rays focused by Kirkpatrick-Baez mirrors

High-flux coherent x rays are necessary for the improvement of the spatial resolution in coherent x-ray diffraction microscopy (CXDM). In this study, high-resolution CXDM using Kirkpatrick-Baez (KB) mirrors is proposed, and the mirrors are designed for experiments of the transmission scheme at SPring-8. Both the photon density and spatial coherence of synchrotron x rays focused by the KB mirrors are investigated by wave optical simulation. The KB mirrors can produce nearly diffraction-limited two-dimensional focusing x rays of approx1 mum in size at 8 keV. When the sample size is less than approx1 mum, the sample can be illuminated with full coherent x rays by adjusting the cross-slit size set between the source and the mirrors. From the estimated photon density at the sample position, the feasibility of CXDM with a sub-1-nm spatial resolution is suggested. The present ultraprecise figuring process enables us to fabricate mirrors for carrying out high-resolution CXDM experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-induced metallic nanograined thin films processing

A direct laser writing method for designing metallic nanograined thin films is presented. This method takes advantage of photon conversion within a chemical process localized at the focal point. A computer controlled positioning system allows the control of experimental parameters and spatial resolution of the pattern. Spectroscopic investigations reveal variable attenuation of the optical properties in UV-visible range and a spectral imaging processing algorithm simulated the functionality of these films in visible light. This could be an important step for obtaining neutral density attenuators.

36 MATERIALS SCIENCE↗

Nanoscale monoclinic domains in epitaxial SrRuO{sub 3} thin films deposited by pulsed laser deposition

In this paper, we analyze the structural distortions observed by transmission electron microscopy in thin epitaxial SrRuO{sub 3} layers used as bottom electrodes in multiferroic coatings onto SrTiO{sub 3} substrates for future multiferroic devices. Regardless of the nature and architecture of the multilayer oxides deposited on the top of the SrRuO{sub 3} thin films, selected area electron diffraction patterns systematically revealed the presence of faint diffraction spots appearing in forbidden positions for the SrRuO{sub 3} orthorhombic structure. High-resolution transmission electron microscopy (HRTEM) combined with Geometric Phase Analysis (GPA) evidenced the origin of these forbidden diffraction spots in the presence of structurally disordered nanometric domains in the SrRuO{sub 3} bottom layers, resulting from a strain-driven phase transformation. The local high compressive strain (−4% ÷ −5%) measured by GPA in the HRTEM images induces a local orthorhombic to monoclinic phase transition by a cooperative rotation of the RuO{sub 6} octahedra. A further confirmation of the origin of the forbidden diffraction spots comes from the simulated diffraction patterns obtained from a monoclinic disordered SrRuO{sub 3} structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Large area strain analysis using scanning transmission electron microscopy across multiple images

Here, we apply revolving scanning transmission electron microscopy to measure lattice strain across a sample using a single reference area. To do so, we remove image distortion introduced by sample drift, which usually restricts strain analysis to a single image. Overcoming this challenge, we show that it is possible to use strain reference areas elsewhere in the sample, thereby enabling reliable strain mapping across large areas. As a prototypical example, we determine the strain present within the microstructure of a Ni-based superalloy directly from atom column positions as well as geometric phase analysis. While maintaining atomic resolution, we quantify strain within nanoscale regions and demonstrate that large, unit-cell level strain fluctuations are present within the intermetallic phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct chemical evidence for sphingolipid domains in the plasma membranes of fibroblasts [High-Resolution Chemical Imaging of Sphingolipid Distribution in the Plasma Membrane]

Sphingolipids play important roles in plasma membrane structure and cell signaling. Yet, their lateral distribution in the plasma membrane is poorly understood. Here we quantitatively analyzed the sphingolipid organization on the entire dorsal surface of intact cells by mapping the distribution of 15 N-enriched ions from metabolically labeled 15 N-sphingolipids in the plasma membrane using high-resolution imaging mass spectrometry. Many types of control experiments (internal, positive, negative, and fixation temperature), along with parallel experiments involving the imaging of fluorescent sphingolipids$-$both in living cells and during fixation of living cells$-$exclude potential artifacts. Micrometer-scale sphingolipid patches consisting of numerous 15 Nsphingolipid microdomains with mean diameters of ~200 nm are always present in the plasma membrane. Depletion of 30% of the cellular cholesterol did not eliminate the sphingolipid domains, but did reduce their abundance and long range organization in the plasma membrane. In contrast, disruption of the cytoskeleton eliminated the sphingolipid domains. These results indicate that these sphingolipid assemblages are not lipid rafts, and are instead a distinctly different type of sphingolipid-enriched plasma membrane domain that depends upon cortical actin.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

KEPLER OBSERVATIONS OF THREE PRE-LAUNCH EXOPLANET CANDIDATES: DISCOVERY OF TWO ECLIPSING BINARIES AND A NEW EXOPLANET

Three transiting exoplanet candidate stars were discovered in a ground-based photometric survey prior to the launch of NASA's Kepler mission. Kepler observations of them were obtained during Quarter 1 of the Kepler mission. All three stars are faint by radial velocity follow-up standards, so we have examined these candidates with regard to eliminating false positives and providing high confidence exoplanet selection. We present a first attempt to exclude false positives for this set of faint stars without high-resolution radial velocity analysis. This method of exoplanet confirmation will form a large part of the Kepler mission follow-up for Jupiter-sized exoplanet candidates orbiting faint stars. Using the Kepler light curves and pixel data, as well as medium-resolution reconnaissance spectroscopy and speckle imaging, we find that two of our candidates are binary stars. One consists of a late-F star with an early M companion, while the other is a K0 star plus a late M-dwarf/brown dwarf in a 19 day elliptical orbit. The third candidate (BOKS-1) is an r = 15 G8V star hosting a newly discovered exoplanet with a radius of 1.12 R{sub Jupiter} in a 3.9 day orbit.

79 ASTRONOMY AND ASTROPHYSICS↗

LOCALIZING SAGITTARIUS A* AND M87 ON MICROARCSECOND SCALES WITH MILLIMETER VERY LONG BASELINE INTERFEROMETRY

With the advent of the Event Horizon Telescope (EHT), a millimeter/submillimeter very long baseline interferometer (VLBI), it has become possible to image a handful of black holes with sub-horizon resolutions. However, these images do not translate into microarcsecond absolute positions due to the lack of absolute phase information when an external phase reference is not used. Due to the short atmospheric coherence time at these wavelengths, nodding between the source and phase reference is impractical. However, here we suggest an alternative scheme which makes use of the fact that many of the VLBI stations within the EHT are arrays in their own right. With this we show that it should be possible to absolutely position the supermassive black holes at the centers of the Milky Way (Sgr A*) and M87 relative to nearby objects with precisions of roughly 1 {mu}as. This is sufficient to detect the perturbations to Sgr A*'s position resulting from interactions with the stars and stellar-mass black holes in the Galactic cusp on year timescales, and severely constrain the astrophysically relevant parameter space for an orbiting intermediate-mass black hole, implicated in some mechanisms for producing the young massive stars in the Galactic center. For M87, it allows the registering of millimeter images, in which the black hole may be identified by its silhouette against nearby emission, and existing larger-scale radio images, eliminating present ambiguities in the nature of the radio core and inclination, opening angle, and source of the radio jet.

79 ASTRONOMY AND ASTROPHYSICS↗