Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Flow Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Southwestern Power Administration Combined Financial Statements, 2006-2009

We have audited the accompanying combined balance sheets of the Southwestern Federal Power System (SWFPS), as of September 30, 2009, 2008, 2007, and 2006, and the related combined statements of revenues and expenses, changes in capitalization, and cash flows for the years then ended. As described in note 1(a), the combined financial statement presentation includes the hydroelectric generation functions of another Federal agency (hereinafter referred to as the generating agency), for which Southwestern Power Administration (Southwestern) markets and transmits power. These combined financial statements are the responsibility of the management of Southwestern and the generating agency. Our responsibility is to express an opinion on these combined financial statements based on our audits. We conducted our audits in accordance with auditing standards generally accepted in the United States of America. Those standards require that we plan and perform the audits to obtain reasonable assurance about whether the combined financial statements are free of material misstatement. An audit includes consideration of internal control over financial reporting as a basis for designing audit procedures that are appropriate in the circumstances, but not for the purpose of expressing an opinion on the effectiveness of Southwestern and the generating agency’s internal control over financial reporting. Accordingly, we express no such opinion. An audit also includes examining, on a test basis, evidence supporting the amounts and disclosures in the combined financial statements, assessing the accounting principles used and significant estimates made by management, as well as evaluating the overall combined financial statement presentation. We believe that our audits provide a reasonable basis for our opinion. In our opinion, the combined financial statements referred to above present fairly, in all material respects, the respective financial position of the Southwestern Federal Power System, as of September 30, 2009, 2008, 2007, and 2006, and the results of its operations and its cash flow for the years then ended, in conformity with U.S. generally accepted accounting principles. Our audits were conducted for the purpose of forming an opinion on the 2009, 2008, 2007, and 2006 SWFPS’s combined financial statements taken as a whole. The supplementary information in the combining financial statements is presented for purposes of additional analysis and is not a required part of the basic combined financial statements. The supplementary information has been subjected to the auditing procedures applied in the audit of the basic combined financial statements and, in our opinion, is fairly stated in all material respects in relation to the basic combined financial statements taken as a whole.

Financial statements, finance, 2009, 2008, 2007, 2↗

Securing against malicious control of circuit breakers in electrical substations

An example method for detecting and mitigating attacks on electric power substations comprises detecting a command to open or close a circuit breaker in the electric power substation. A modified extended substation model for the electric power substation is generated, based on the detected command and based on measurements in substation, where the modified extended substation model is a power flow model for the substation and for one or more directly connected neighboring substations. A power flow analysis is performed, using the modified extended substation model, to generate a predicted voltage for each of a plurality of nodes in the substation and in the one or more directly connected neighboring substations. Each predicted voltage is compared to a corresponding allowable voltage range, and execution of the command is blocked in response to determining that one or more of the voltages is outside the corresponding allowable voltage range.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Securing against malicious control of circuit breakers in electrical substations

An example method for detecting and mitigating attacks on electric power substations comprises detecting a command to open or close a circuit breaker in the electric power substation. A modified extended substation model for the electric power substation is generated, based on the detected command and based on measurements in substation, where the modified extended substation model is a power flow model for the substation and for one or more directly connected neighboring substations. A power flow analysis is performed, using the modified extended substation model, to generate a predicted voltage for each of a plurality of nodes in the substation and in the one or more directly connected neighboring substations. Each predicted voltage is compared to a corresponding allowable voltage range, and execution of the command is blocked in response to determining that one or more of the voltages is outside the corresponding allowable voltage range.

97 MATHEMATICS AND COMPUTING↗

(Project 18-15502) Reducing Uncertainty in Radionuclide Transport Prediction Using Multiple Environmental Tracers (Final Report)

In order to successfully site and design a nuclear waste disposal facility, DOE scientists are required to show safe containment of the radioactive waste for up to 1 million years. A significant hurdle to accurately and convincingly demonstrating disposal safety is predicting the fate of radioactive elements once they enter the groundwater system surrounding the repository. These predictions are often made with computer models, which contain accurate physics of groundwater movement and chemical reactions that occur during groundwater flow. As computer power increases, the physics and chemistry of these computer simulators can become more and more realistic and the physically based error decreases. However, the ability of these computer models to provide accurate predictions in a specific place, over long time periods, requires the scientists and engineers to know the subsurface properties of the Earth that control groundwater movement. In particular, groundwater scientists and engineers need to know the groundwater fluid velocity, which can change over time and strongly vary with location within the groundwater system. Because the Earth’s subsurface cannot be directly seen, and can only be sampled at drilling locations, the properties of the groundwater system are never known completely, and computer models of groundwater transport will always have some amount of uncertainty. This project’s principal goal was to use chemicals and isotope “tracers”, which have been introduced to the groundwater system by natural processes over long time periods, to help inform computer models of the groundwater velocity and subsurface properties. The goal was to calculate how much better predictions of groundwater transport were when these “tracers” were used to inform the computer models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analyzing the Effects of Atmospheric Turbulent Fluctuations on the Wake Structure of Wind Turbines and Their Blade Vibrational Dynamics

In recent trends, a rising demand for renewable energy has driven wind turbines to larger proportions, where lighter blade designs are often adopted to reduce the costs associated with logistics and production. This causes modern utility-scale wind turbine blades to be inherently more flexible, and their amplified aeroelastic sensitivity results in complex multi-physics reactions to variant atmospheric conditions, including dynamic patterns of aerodynamic loading at the rotor and vortex structure evolutions within the wake. In this paper, we analyze the influence of inflow variance for wind turbines with large, flexible rotors through simulations of the National Rotor Testbed (NRT) turbine, located at Sandia National Labs’ Scaled Wind Farm Technology (SWiFT) facility in Lubbock, Texas. The Common Ordinary Differential Equation Framework (CODEF) modeling suite is used to simulate wind turbine aeroelastic oscillatory behavior and wind farm vortex wake interactions for a range of flexible NRT blade variations, operating in differing conditions of variant atmospheric flow. CODEF solutions of turbine operation in Steady-In-The-Average (SITA) wind conditions are compared to SITA wind conditions featuring a controlled gust-like pulse overimposed, to isolate the effects of typical wind fluctuations. Finally, simulations of realistic time-varying wind conditions from SWiFT meteorological tower measurements are compared to the solutions of SITA wind conditions. These increasingly complex atmospheric inflow variations are tested to show the differing effects evoked by various patterns of spatiotemporal atmospheric flow fluctuations. An analysis is presented for solutions of wind turbine aeroelastic response and vortex wake evolution, to elucidate the consequences of variant inflow, which pertain to wind turbine dynamics at an individual and farm-collective scale. The comparisons of simulated farm flow for SITA and measured fluctuating wind conditions show that certain regions of the wake contain up to a 12% difference in normalized axial velocity, due to the introduction of wind fluctuations. The findings of this study prove valuable for practical applications in wind farm control and optimization strategies, with particular significance for modern utility-scale wind power plants operating in variant atmospheric conditions.

Farrell, Alayna (ORCID:000000023555720X)↗

Simulation of the dynamics of gas mixtures during plasma processing in the C75 Cavity

Plasma processing using a mixture of noble gas and oxygen is a technique that is currently being used to reduce field emission and multipacting in accelerating cavities. Plasma is created inside the cavity when the gas mixture is exposed to an electromagnetic field that is generated by applying RF power through the fundamental power or higher-order mode couplers. Oxygen ions and atomic oxygen are created in the plasma which breaks down the hydrocarbons on the surface of the cavity and the residuals from this process are removed as part of the process gas flow. Removal of hydrocarbons from the surface increases the work function and reduces the secondary emission coefficient. This work describes the initial results of plasma simulation, which provides insight into the ignition process, distribution of different species, and interactions of free oxygen and oxygen ions with the cavity surfaces. The simulations have been done with an Ar/?2 plasma using COMSOL® multiphysics. These simulations help in understanding the dynamics and control of plasma inside the cavity and the exploration of different gas mixtures.

Dhakal, Pashupati↗

Bio-inspired bistable piezoelectric energy harvester for powering animal telemetry tags: Conceptual design and preliminary experimental validation

Here, this paper presents the conceptual design, preliminary experimental validation, and performance evaluation of a novel bio-inspired bi-stable piezoelectric energy harvester for self-powered animal telemetry tags. The overall conceptual design, which includes a bio-inspired attachment and a bi-stable piezoelectric energy harvester, is introduced firstly with a specific application example of marine fish tracking. The self-powered telemetry tag can be externally deployed on fish (dorsal fin) to monitor fish habitats, population, and underwater environment. Inspired by the Venus flytrap's rapid shape transition, a bi-stable piezoelectric energy harvester is developed to scavenge energy from fish maneuvering and the surrounding fluid flow for a sustainable power supply. The bistability of the harvester is characterized by the measured force-displacement curve and double potential wells. A bluff body is integrated to the free end of the bistable piezoelectric energy harvester to enhance the structure-fluid interaction for the large-amplitude snap-through vibrations and higher voltage output. Controlled laboratory experiments are conducted in a water tank on the bio-inspired bi-stable piezoelectric energy harvester using a servo motor system to simulate fish swing motion at various conditions to evaluate the power generation performance. The preliminary underwater experimental results demonstrated that the proposed bio-inspired bi-stable piezoelectric energy harvester could effectively convert fish swing motions into electricity. The device collected 17.25 mJ of energy over 130 s under a peak-to-peak swing angle of 30° at 1.5 Hz in the capacitor charging experiments.

Animal tracking↗

Bio-inspired Bistable Piezoelectric Energy Harvester for Powering Animal Telemetry Tags: Concept Design and Preliminary Experimental Validation

This paper presents the concept design, preliminary experimental validation, and performance evaluation of a novel bio-inspired bi-stable piezoelectric energy harvester for self-powered animal telemetry tags. The overall concept design, which includes a bio-inspired attachment and a bi-stable piezoelectric energy harvester, is introduced firstly with a specific application example of marine fish tracking. The self-powered telemetry tag can be externally deployed on fish (dorsal fin) to monitor fish habitats, population, and underwater environment. Inspired by the Venus flytrap’s rapid shape transition, a bistable piezoelectric energy harvester is developed to scavenge energy from fish maneuvering and the surrounding fluid flow for a sustainable power supply. The bistability of the harvester is characterized by the measured force-displacement curve and double potential wells. A bluff body is integrated to the free end of the bistable piezoelectric energy harvester to enhance the structure-fluid interaction for the large-amplitude snap-through vibrations and higher voltage output. Controlled laboratory experiments are conducted in a water tank on the bio-inspired bi-stable piezoelectric energy harvester using a servo motor system to simulate fish swing motion at various conditions to evaluate the power generation performance. The preliminary underwater experimental results demonstrated that the proposed bio-inspired bi-stable piezoelectric could effectively converter fish swing motions into electricity. 17.25 mJ energy was obtained within 130 s under the peak-to-peak swing angle of 30o at 1.5 Hz in the capacitor charging experiments.

Qian, Feng↗

Analysis of Brayton Cycles Utilizing Supercritical Carbon Dioxide

This white paper documents a detailed and extensive Brayton cycle analysis that was performed to better understand at a fundamental level the dependence of the Brayton cycle performance on operating conditions, working fluid, supercritical fluid properties, and some cycle non-idealities. This work was performed to better understand the factors controlling Brayton cycle performance and optimal operating conditions, particularly for cycles utilizing supercritical CO 2 (sCO 2 ) as the working fluid. The focus of this study is on cycle performance, particularly efficiency. No cost estimates were performed. However, as a single indirect measure of cycle cost, some sensitivity analyses on specific power (net output divided by working fluid mass flow rate) were included.

42 ENGINEERING↗

Full loop thermodynamic corrosion inhibition and sensing in molten chloride systems. Final report

The objective of this project is to increase the lifetime of Concentrated Solar Power (CSP) systems by identifying corrosion mitigation methods for heat transfer loops in the temperature range of 500 - 800 °C. Coupling of experimental data with CFD modeling has provided greater insight into corrosion mitigation methods and how they will be applied in molten salt systems with convective flows. The overall goal of the program is to demonstrate techniques that control corrosion while having limited impact on system alloys.

14 SOLAR ENERGY↗

Rapidly ramp cryogenic air separation unit without loss of O2 product purity—application for low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for low-carbon, fossil-fuel power plant capable of rapid ramping. Therefore, a cryogenic air separation unit (ASU) as part of low-carbon, fossil-fuel power plant should be capable of rapid ramping. However, highly integrated and nonlinear processes of the ASU would significantly restrict this rapid ramping. To overcome this fundamental issue, we study the basic dynamic process of a state-of-the-art double-column ASU. A flow-driven dynamic model was established in Aspen Plus Dynamics, assuming perfect flow controls, to capture the basic dynamics of ramping ASU. We find the vapor-liquid counter-current flow structure in the low-pressure column is critical to the air separation when rapidly ramping the ASU. This flow structure is established based on a complicated heat integration process. It is simplified as an apparent counter-current heat transfer process in this work, which greatly reduces the complexity for studying the dynamics of ASU. For keeping this basic flow structure, the heat integration is maintained as its heat duty follows the ASU load, through several basic feed-forward and feed-back controllers on the critical stream flowrates. Moreover, we find a fundamental issue of mismatched dynamics in the low-pressure column, resulting in a significant loss of O2 product purity when rapidly ramping down the ASU and an obvious fluctuation of O2 product purity. Based on these explorations, we propose a basic control method for rapidly ramping the ASU without loss of O2 product purity. Results show the ASU basic dynamic process successfully ramps at a rate up to 10%/min (40-100% load) while maintaining the O2 product purity within 95.2-95.6 mol%.

Cheng, Mao↗

A STRONGLY COUPLED REACTOR CORE ISOLATION COOLING SYSTEM MODEL FOR EXTENDED STATION BLACK-OUT ANALYSES

The reactor core isolation cooling (RCIC) system in a boiling water reactor (BWR) provides makeup cooling water to the reactor pressure vessel (RPV) when the main steam lines are isolated and the normal supply of water to the reactor vessel is lost. The RCIC system operates independently of AC power, service air, or external cooling water systems. The only required external energy source is from the battery to maintain the logic circuits to control the opening and/or closure of valves in the RCIC systems in order to control the RPV water level by shutting down the RCIC pump to avoid overfilling the RPV and flooding the steam line to the RCIC turbine. It is generally considered in almost all the existing station black-out accidents (SBO) analyses that loss of the DC power would result in overfilling the steam line and allowing liquid water to flow into the RCIC turbine, where it is assumed that the turbine would then be disabled. This behavior, however, was not observed in the Fukushima Daiichi accidents, where the Unit 2 RCIC functioned without DC power for nearly three days. Therefore, more detailed mechanistic models for RCIC system components are needed to understand the extended SBO for BWRs. As part of the effort to develop the next generation reactor system safety analysis code RELAP-7, we have developed a strongly coupled RCIC system model, which consists of a turbine model, a pump model, a check valve model, a wet well model, and their coupling models. Unlike the traditional SBO simulations where mass flow rates are typically given in the input file through time dependent functions, the real mass flow rates through the turbine and the pump loops in our model are dynamically calculated according to conservation laws and turbine/pump operation curves. A simplified SBO demonstration RELAP-7 model with this RCIC model has been successfully developed. The demonstration model includes the major components for the primary system of a BWR, as well as the safety system components such as the safety relief valve (SRV), the RCIC system, the wet well, and the dry well. The results show reasonable system behaviors while exhibiting rich dynamics such as variable flow rates through RCIC turbine and pump during the SBO transient. The model has the potential to resolve the Fukushima RCIC mystery after adding the off-design two-phase turbine operation model and other additional improvements.

RCIC↗

Modelling Nuclear Thermal Propulsion Reactor Expander Cycle Startup Transients

As the interest in nuclear thermal propulsion grows, the need for high fidelity and comprehensive models of the system increases. An expander cycle model was developed using RELAP-7 for the thermal-hydraulic performance and Griffin to provide the power level using a point kinetics approximation, for a reference NTP system. The tank and pump are approximated using boundary conditions. Flow is split between the moderator cooling channels flow path and the regenerative cooling/reflector cooling channels flow path. The flow recombines before entering the turbine and the fuel cooling channels. The turbine pressure ratio is maintained at 1.44 using a PID controller. A startup transient was simulated and shows the capability of the model to run from low temperature and pressures to nominal conditions.

33 ADVANCED PROPULSION SYSTEMS↗

Modelling Nuclear Thermal Propulsion Reactor Expander Cycle Startup Transients

As the interest in nuclear thermal propulsion grows, the need for high fidelity and comprehensive models of the system increases. An expander cycle model was developed using RELAP-7 for the thermal-hydraulic performance and Griffin to provide the power level using a point kinetics approximation, for a reference NTP system. The tank and pump are approximated using boundary conditions. Flow is split between the moderator cooling channels flow path and the regenerative cooling/reflector cooling channels flow path. The flow recombines before entering the turbine and the fuel cooling channels. The turbine pressure ratio is maintained at 1.44 using a PID controller. A startup transient was simulated and shows the capability of the model to run from low temperature and pressures to nominal conditions.

33 ADVANCED PROPULSION SYSTEMS↗

Biomass Combustion in a Circulating Fluidized Bed Combustor

Interest in circulating fluidized bed (CFB) boilers as a power generation technology has skyrocketed in recent years because of several advantages this technology offers over conventional boilers, such as increased gas-solid mixing resulting in higher combustion efficiency and the ability to use lower quality fuels. CFB combustors are operated at lower temperatures than conventional thermal power generation combustors, thus reducing NO x emissions. SO 2 emissions are conveniently controlled through the addition of Ca-based sulphur sorbents within the combustor. This report summarizes the current modeling effort on a 50 kW th CFB combustor with a diameter of 10 cm and a height of 5 m; designed, built, and operated at CanmetENERGY in Ottawa, Canada employing the multiphase particle-in-cell (PIC) approach in the open-source Multiphase Flow with Interphase eXchanges (MFiX) Software Suite. The MFiX-PIC model parameters for the simulation are tuned against cold-flow experiments from CanmetENERGY using 9 kg of olivine sand as the inert bed material. It is shown that for the relatively coarse fluid meshes and large parcel sizes necessitated by the scale of the simulation, filter size dependent corrections to the drag law must be incorporated to ensure accuracy of the simulation results. The validated cold flow model is extended to simulate reacting flow with torrefied hardwood as the feedstock and to validate the combustion reaction scheme. The species concentrations at the riser outlet are compared against CanmetENERGY’s experiments and show satisfactory agreement. The simulations demonstrate the ability of MFiX-PIC to accurately capture the physics and chemistry of a circulating fluidized bed combustor at bench scales, which can be further extended to pilot- and industrial-scale systems.

20 FOSSIL-FUELED POWER PLANTS↗

Demonstration of a Thermosyphon Thermal Valve for Controlled Extraction of Stored Solar Thermal Energy

For concentrated solar power (CSP) to be an effective replacement for power generation by fossil fuels, the thermal energy must be stored and then released for when demand exceeds production, such as during off-sun hours. Until now, there has been limited methods to reliably and efficiently release and control the extraction of thermal energy from a material containing stored sensible or latent heat. Due to their isothermal property, phase change materials (PCMs) storing latent heat are an ideal choice for storage, though it has proven challenging to reliably extract and utilize that heat. To solve this problem, the geometry of a thermosyphon was rearranged to create a thermal valve that is able to turn the flow of thermal energy from a PCM 'on' and 'off'. A stainless steel thermal valve using sodium as the working fluid was designed, fabricated, assessed, and found to effectively and selectively extract heat from a 577 degrees C molten aluminum PCM. It is expected that thermal valves will significantly contribute to more widespread implementation of CSP as a stored energy source from distributed generation to utility-scale power production.

14 SOLAR ENERGY↗

CaloriSMART: Small-scale test-stand for rapid evaluation of active magnetic regenerator performance

We report operation of a device designed specifically for rapid experimental evaluation of performance of magnetocaloric materials in different magnetic fields using a compact active magnetic regenerator bed with a total volume of approximately 5 mL. Other features of the system include digital control of the rotating-permanent-magnet field source and custom dual-opposed syringe pump that enable precise tuning and coupling of the flow profile and the magnetic field profile. Performance of the device is demonstrated for flow volumes between 1 and 4 mL (utilization from 0.48 to 1.9), maximum magnetic fields of 1.13 and 1.45 T, and applied cooling powers from 0 to 20 W at frequencies from 0.5 to 4 Hz. A regenerator comprised of 25 g of 200 µm spherical Gd powder reached temperature spans of 19.3 K under no applied cooling load and 2.6 K under the maximum applied cooling load of 20 W. The device also achieves a very high specific exergetic cooling power of 73 W L -1 T -1 . Results obtained at two different maximum magnetic fields in the same device suggest a powerful new scaling for regenerator performance: the exergetic power quotient. The exergetic power quotient shows a simple scaling of device cooling performance with the amount of active material and the magnetic field strength. This suggests results from a small device correlate to expected performance of a larger regenerator, making the exergetic power quotient a well-suited parameter for evaluating functionality of active magnetic regenerators employing new magnetocaloric materials.

47 OTHER INSTRUMENTATION↗

Multiphysics Running-In Simulations for Pebble-Bed Reactors with Griffin

Griffin, a Multiphysics Object-Oriented Simulation Environment (MOOSE)–based application targeting transient modeling of advanced reactors, has been used recently to model pebble-bed reactors (PBRs). The modeling effort has focused thus far on equilibrium core calculations. A new capability to simulate the running-in phase of PBR operation has been added to Griffin. This work demonstrates the new capability with a coupled multiphysics running-in simulation. Griffin computes power densities in the core at each time step of the running-in simulation and passes these to Pronghorn, which models fluid flow and heat transfer to calculate pebble surface temperatures. These surface temperatures are used along with the power densities in a heat conduction model to compute average fuel and moderator temperatures, which are passed back to Griffin and accounted for with temperature-dependent cross sections. This work also describes a novel methodology for determining appropriate pebble feed rates and control rod positioning during the running-in simulation. Furthermore, the RZ-geometry model used in this work requires minimal computational resources and can be used for optimization and uncertainty studies in future works.

Griffin↗