Development of Nb3Sn multicell cavity coatings
Nb3Sn films have the potential to replace niobium in SRF cavities. Besides single-cell cavity efforts to improve Nb3Sn films, we are working to replicate single-cell results onto the practical 5-cell CEBAF cavities. High quality factors (10E11 @ 2.0K and 10E10 @ 4.3 K) have been measured, but the cavities are typically limited by strong low-field Q-slopes and quenches. Two of the cavities were selected to be assembled into a "mock-up" cavity string unit, the standard step before installation into a cryomodule. Comparison of test results between VTA and pair test offered the first glimpse into post-processing effects on the cavity performance.