At least 991 records · Page 55

MASTODON: An Open-Source Software for Seismic Analysis and Risk Assessment of Critical Infrastructure

Seismic analysis and risk assessment of safety-critical infrastructure like hospitals, nuclear power plants, dams, and facilities handling radioactive materials involve computationally intensive numerical models and coupled multiphysics scenarios. They are also performed in a strict regulatory environment that requires high software quality assurance standards, and in the case of safety-related nuclear facilities, a conformance to the American Society of Mechanical Engineers Nuclear Quality Assurance (NQA-1) standard. This paper introduces the open-source finite-element software, MASTODON (Multi-hazard Analysis of Stochastic Time-Domain Phenomena), which implements state-of-the-art seismic analysis and risk assessment tools in a quality-controlled environment. MASTODON is built on MOOSE (Multi-physics Object-Oriented Simulation Environment), which is a highly parallelizable, NQA-1 conforming, coupled multiphysics, finite-element framework developed at Idaho National Laboratory. MASTODON is capable of fault rupture and source-to-site wave propagation using the domain reduction method, nonlinear site response, and soil-structure interaction analysis, implicit and explicit time integration, automated stochastic simulations, and seismic probabilistic risk assessment. When coupled with other MOOSE applications, MASTODON can also solve strongly and weakly coupled multiphysics problems. This paper presents a summary of the capabilities of MASTODON and some demonstrative examples.

42 ENGINEERING↗

Improved learning from data competitions through strategic design of training and test data sets

Leveraging the depth and breadth of solutions generated through crowdsourcing can be a powerful accelerator to method development for high consequence problems. While data science competitions have become quite popular and prevalent, particularly in supervised learning formats, their implementations by the host are highly variable. Without careful planning, a supervised learning competition is vulnerable to overfitting, where the winning solutions are so closely tuned to the particular set of provided data that they cannot generalize to the general underlying problem of interest to the host. This paper outlines important considerations for strategically designing relevant and informative data sets to maximize the learning outcome from hosting a competition. These include: precisely defining the scope of the problem, encouraging participation by competitors from diverse technical backgrounds, specifying the most interesting solution space in order to encourage improvement and distinguish between competitors, strategically generating data sets that enable testing for interpolation and extrapolation to new scenarios of interest, leveraging design of experiment principles for strategic data design while preventing unintentional artifacts in the competition data set that an algorithm could exploit without addressing the real problem of interest, and carefully designing the leaderboard scoring metric to select top solutions that exactly match the overall competition goals. The methods are illustrated with a recently completed competition in the context of urban radiological search to evaluate algorithms capable of detecting, identifying, and locating radioactive materials. Simulated data were used in the urban search competition. Ideas for using measured real data in competitions are also suggested

97 MATHEMATICS AND COMPUTING↗

Low-background temperature sensors fabricated on parylene substrates

Temperature sensors fabricated from ultra-low radioactivity materials have been developed for low-background experiments searching for neutrinoless double-beta decay and the interactions of WIMP dark matter. The sensors consist of electrical traces photolithographically-patterned onto substrates of vapor-deposited parylene. They are demonstrated to function as expected, to do so reliably and robustly, and to be highly radio-pure. This work is a proof-of-concept study of a technology that can be applied to broad class of electronic circuits used in low-background experiments.

47 OTHER INSTRUMENTATION↗

The Majorana Demonstrator readout electronics system

The M AJORANA D EMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76 Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the M AJORANA D EMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Target development using the method of High-Intensity Vibrational Powder Plating (HIVIPP) at the Center for Accelerator Target Science (CATS) at Argonne National Laboratory (ANL)

One of the primary goals of the Center for Accelerator Target Science (CATS) is to provide targets and foils in support of the ATLAS User Facility and the Low-Energy community at large. While a wide array of target production techniques are available at CATS, new methods that must be explored invariably arise. One such technique, the High-Intensity Vibrational Powder Plating (HIVIPP), was first reported in 1997 by Isao Sugai. It was developed to produce targets and stripper foils that were difficult to make by standard methods. At Argonne National Laboratory (ANL), we have successfully constructed and tested a simple system for this purpose. We have produced targets of carbon and titanium on various metal backings using the HIVIPP method. We are currently in the exciting phase of exploring the production of other elements, including isotopically enriched and radioactive material. This work is in progress and will be further detailed with specific examples.

47 OTHER INSTRUMENTATION↗

The effect of jet–ejecta interaction on the viewing angle dependence of kilonova light curves

ABSTRACT The merger of two neutron stars produces an outflow of radioactive heavy nuclei. Within a second of merger, the central remnant is expected to also launch a relativistic jet, which shock-heats and disrupts a portion of the radioactive ejecta. Within a few hours, emission from the radioactive material gives rise to an ultraviolet, optical, and infrared transient (a kilonova). We use the endstates of a suite of 2D relativistic hydrodynamic simulations of jet–ejecta interaction as initial conditions for multidimensional Monte Carlo radiation transport simulations of the resulting viewing angle-dependent light curves and spectra starting at $1.5\, \mathrm{h}$ after merger. We find that on this time-scale, jet shock heating does not affect the kilonova emission for the jet parameters we survey. However, the jet disruption to the density structure of the ejecta does change the light curves. The jet carves a channel into the otherwise spheroidal ejecta, revealing the hot, inner regions. As seen from near (≲30°) the jet axis, the kilonova is brighter by a factor of a few and bluer. The strength of this effect depends on the jet parameters, since the light curves of more heavily disrupted ejecta are more strongly affected. The light curves and spectra are also more heavily modified in the ultraviolet than in the optical.

Klion, Hannah↗

A brief overview of compartmental modeling for intake of plutonium via wounds

Here, the aim of this study is to present several approaches that have been used to model the behavior of radioactive materials (specifically Pu) in contaminated wounds. We also review some attempts by the health physics community to validate and revise the National Council on Radiation Protection and Measurements (NCRP) 156 biokinetic model for wounds, and present some general recommendations based on the review. Modeling of intake via the wound pathway is complicated because of a large array of wound characteristics (e.g. solubility and chemistry of the material, type and depth of the tissue injury, anatomical location of injury). Moreover, because a majority of the documented wound cases in humans are medically treated (excised or treated with chelation), the data to develop biokinetic models for unperturbed wound exposures are limited. Since the NCRP wound model was largely developed from animal data, it is important to continue to validate and improve the model using human data whenever plausible.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of urinary excretion data from three plutonium-contaminated wounds at Los Alamos National Laboratory

The NCRP-156 Report proposes seven different biokinetic models for the wound cases depending on the physicochemistry of the contaminant. Because the models were heavily based on experimental animal data, the authors of the report encouraged application and validation of the models using bioassay data from actual human exposures. Each of the wound models was applied to three plutonium-contaminated wounds, and the models resulted in a good agreement to only one of the cases. We then applied a simpler biokinetic model structure to the bioassay data and showed that fitting the transfer rates from this model structure yielded better agreement with the data than does the best-fitting NCRP-156 model. Because the biokinetics of radioactive material in each wound is different, it is impractical to propose a discrete set of model parameters to describe the biokinetics of radionuclides in all wounds, and thus each wound should be treated empirically.

61 RADIATION PROTECTION AND DOSIMETRY↗

Primary Beam Air Kerma Dependence on Distance from Cargo and People Scanners

The distance dependence of air kerma or dose rate of the primary radiation beam is not obvious for security scanners of cargo and people in which there is relative motion between a collimated source and the person or object being imaged. To study this problem, one fixed line source and three moving-source scan-geometry cases are considered, each characterized by radiation emanating perpendicular to an axis. The cases are 1) a stationary line source of radioactive material, e.g., contaminated solution in a pipe; 2) a moving, uncollimated point source of radiation that is shuttered or off when it is stationary; 3) a moving, collimated point source of radiation that is shuttered or off when it is stationary; and 4) a translating, narrow “pencil” beam emanating in a flying-spot, raster pattern. Each case is considered for short and long distances compared to the line source length or path traversed by a moving source. The short distance model pertains mostly to dose to objects being scanned and personnel associated with the screening operation. The long distance model pertains mostly to potential dose to bystanders. For radionuclide sources, the number of nuclear transitions that occur a) per unit length of a line source, or b) during the traversal of a point source, is a unifying concept. The “universal source strength” of air kerma rate at a meter from the source can be used to describe x-ray machine or radionuclide sources. For many cargo and people scanners with highly collimated fan or pencil beams, dose varies as the inverse of the distance from the source in the near field and with the inverse square of the distance beyond a critical radius. Ignoring the inverse square dependence and using inverse distance dependence is conservative in the sense of tending to overestimate dose.

Beam↗

Gamma-ray dose from an overhead plume

Standard plume models can underestimate the gamma-ray dose when most of the radioactive material is above the heads of the receptors. Typically, a model is used to calculate the air concentration at the height of the receptor, and the dose is calculated by multiplying the air concentration by a concentration-to-dose conversion factor. Models indicate that if the plume is emitted from a stack during stable atmospheric conditions, the lower edges of the plume may not reach the ground, in which case both the ground-level concentration and the dose are usually reported as zero. However, in such cases, the dose from overhead gamma-emitting radionuclides may be substantial. Such underestimates could impact decision making in emergency situations. The Monte Carlo N-Particle code, MCNP, was used to calculate the overhead shine dose and to compare with standard plume models. At long distances and during unstable atmospheric conditions, the MCNP results agree with the standard models. As a result, at short distances, where many models calculate zero, the true dose (as modeled by MCNP) can be estimated with simple equations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Interpretation of Urinary Excretion Data From Plutonium Wound Cases Treated With DTPA: Application of Different Models and Approaches

After a chelation treatment, assessment of intake and doses is the primary concern of an internal dosimetrist. Using the urinary excretion data from two actual wound cases encountered at Los Alamos National Laboratory (LANL), this study discusses several methods that can be used to interpret intakes from the urinary data collected after one or multiple chelation treatments. One of the methods uses only the data assumed to be unaffected by chelation (data collected beyond 100 d after the last treatment). This method, used by many facilities for official dose records, was implemented by employing maximum likelihood analysis and Bayesian analysis methods. The impacts of an improper assumption about the physicochemical behavior of a radioactive material and the importance of the use of a facility-specific biokinetic model when available have also been demonstrated. Another method analyzed both the affected and unaffected urinary data using an empirical urinary excretion model. This method, although case-specific, was useful in determining the actual intakes and the doses averted or the reduction in body burdens due to chelation treatments. Finally, this approach was important in determining the enhancement factors, the behavior of the chelate, and other observations that may be pertinent to several DTPA compartmental modeling approaches being conducted by the health physics community.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

EVALUATION OF AN UPWARD TREND IN BACKGROUND COUNT RATES FROM A STACK PARTICULATE CONTINUOUS AIR MONITOR

The Pacific Northwest National Laboratory (PNNL) operates the Radiochemical Processing Laboratory (RPL), which is a multi-purpose, non-reactor nuclear research facility. Regulations require both continuous sampling and monitoring of radioactive particulates and tritium gas in the exhaust from the main stack. Releases of other radioactive gases, including planned releases of radon, are tracked separately in a database and reported. During the 2015 calibration of the RPL stack continuous air monitor (CAM), measured alpha and beta background count rates were much higher than expected, especially when compared to count rates from previous calibrations. The source of the higher background count rates was examined by trending of historical CAM measurements and a comparison to the sampler data. The analysis revealed that the sample results showed no increase in emissions, whereas the CAM showed a steady increase in count rates. Ultimately, the CAM filter was analyzed and found to contain higher-than-normal background levels of 220Rn progeny. Assessments were performed to determine the cause of the increased background values, including reviews of building research activities, radioactive material usage and storage, adequacy of procedures, and the potential for internal CAM contamination. Project reviews determined that a research activity involving 228Th was left in a semi-stored state, resulting in 220Rn being released from a hot cell into the exhaust system. The 228Th source material was subsequently repackaged and contained resulting in a decrease of CAM background count rates. An estimate of the 220Rn release was made and the contribution to the annual offsite dose from the facility was calculated. The released activity and reported dose results were well below the permit limits for the facility.

radon, 220Rn, environmental assessment, air monito↗

Use of CAP88 at Department of Energy Sites

The U.S. Department of Energy is committed to protecting the public and environment against undue risk from radiation associated with radiological activities conducted under its control. Some U.S. Department of Energy Site activities result in emissions of radioactive materials to the air. CAP88 codes are used to model these emissions and the subsequent maximum estimated dose to a member of the public in the vicinity of the U.S. Department of Energy Site. This paper reviews the use of the CAP88 code at the variety of U.S. Department of Energy sites that use it for compliance reporting under 40 CFR Part 61, Subpart H.

54 ENVIRONMENTAL SCIENCES↗

Aerial Survey Results for 131I Deposition on the Ground after the Fukushima Daiichi Nuclear Power Plant Accident

In March 2011 the second largest accidental release of radioactivity in history occurred at the Fukushima Daiichi nuclear power plant following a magnitude 9.0 earthquake and subsequent tsunami. Teams from the U.S. Department of Energy, National Nuclear Security Administration Office of Emergency Response performed aerial surveys to provide initial maps of the dispersal of radioactive material in Japan. The initial results from the surveys did not report the concentration of 131I. This work reports on analyses performed on the initial survey data by a joint Japan-US collaboration to determine 131I ground concentration. This information is potentially useful in reconstruction of the inhalation and external exposure doses from this short-lived radionuclide. The deposited concentration of 134Cs is also reported.

Fukushima, I-131, aerial survey↗

Development of Fast Decay-Energy Spectroscopy With Magnetic Microcalorimeters

Decay energy spectroscopy (DES) is an increasingly important radiometric technique arising from the unique thermal detection physics and the precision of low-temperature microcalorimetry. DES can enable high-precision analysis of very small amounts of radioactive material with simple and rapid sample preparation, making it a key new tool for nuclear safeguards, nuclear forensics, the improvement of nuclear data, measurements of absolute activity, and other applications. For problems in nuclear safeguards and nuclear forensics it is highly desirable to increase the count rates achievable in DES, while maintaining simple and rapid sample preparation. Here, in this report, we describe progress in a new project to achieve high count rates in DES by taking advantage of the physics of magnetic microcalorimetry. We describe the results of initial modeling and experiment to validate the idea, a sample fabrication technique suitable for nuclear materials laboratories, the preparation and initial tests of paramagnetic Au-Er alloy in thin foil form, and the development of a sensing coil geometry that will perform well with the increased-thickness sensor used in the new technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The spectrometric determination of the individual exposure rate for gamma nuclides from an environmental radiation detector

For making the spectrometric determination of the exposure rate from the environment as well as the radioactive material more practical, an accurate calculation method of the individual exposure rate for the detected gamma nuclides from that spectrum should be suggested without the sophisticated calibration procedure. In this study, the calculation method for the individual exposure rate for detected gamma nuclides from a 3'x3' NaI(Tl) detector was suggested by introducing the concept of the dose rate spectroscopy and the peak-to-total ratio in the energy spectrum for the exposure rate, which means just a form of multiplied counts and the value of a G-factor in the spectrum. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HELIUM LEAK TEST MODELING OF A SPENT NUCLEAR FUEL CANISTER

The U.S. Department of Energy (DOE) is considering the development of one or more federal consolidated interim storage facilities (CISFs) to be used to store commercial spent nuclear fuel (SNF) at locations in the U.S. One of the first technical challenges of a CISF is performing an inspection of SNF canisters upon their receipt to confirm they can be placed into the CISF’s licensed storage configuration. The canister receipt inspection is critical to CISF site operations. The test is conceived as being a helium (He) leak check, intended to confirm that the confinement boundary of a SNF canister is intact. SNF canisters are filled with He when they are sealed, so detection of a He leak indicates that a through-wall flaw has occurred in the canister confinement boundary. Other measurements are planned to occur upon canister receipt in addition to the He leak check such as krypton-85 measurements, which would indicate confinement breaches of one or more fuel rods in addition to a breach of the SNF canister. However, the He leak check has been identified as one of such high importance and has such significant technical challenges that a full-scale demonstration is needed to confirm the He leak test’s viability and to assist in planning relative to its operational requirements. A modeling methodology for simulating the He detection test was developed to help inform the test plan and the design of the test vessels. To develop the modeling methodology a detailed computational fluid dynamics (CFD) benchmark model was constructed to compare against leak rate test data from a transportation package for radioactive material. This report is focused on modeling efforts to simulate the benchmark leak test.

Suffield, Sarah R.↗

Neutron Energy Measurements in Emergency Response Applications

We present significant results in recent advances in the measurement of neutron energy. Neutron energy measurements are a small but significant part of radiological emergency response applications. Mission critical information can be obtained by analyzing the neutron energy given off from radioactive materials. In the case of searching for special nuclear materials, neutron energy information from an unknown source can be of importance. At the Remote Sensing Laboratory (RSL) of National Security Technologies, LLC, a series of materials, viz., liquid organic scintillator (LOS), Lithium Gadolinium Borate (LGB) or Li6Gd(BO3)3 in a plastic matrix, a recently developed crystal of Cesium Lithium Yttrium Chloride, Cs2LiYCl6: Ce (called CLYC)[1], and normal plastic scintillator (BC-408) with 3He tubes have been used to study their effectiveness as a portable neutron energy spectrometer. Comparisons illustrating the strengths of the various materials will be provided. Of these materials, LGB offers the ability to tailor its response to the neutron spectrum by varying the isotopic composition of the key constituents (Lithium, Gadolinium [Yttrium], and Boron). All three of the constituent elements possess large neutron capture cross section isotopes for highly exothermic reactions. These compounds of composition Li6Gd(Y)(BO3)3 can be activated by Cerium ions Ce3+. CLYC, on the other hand, has a remarkable gamma response in addition to superb neutron discrimination, comparable to that of Europium-doped Lithium Iodide (6LiI: Eu). Comparing these two materials, CLYC has higher light output (4500 phe/MeV) than that from 6LiI: Eu and shows better energy resolution for both gamma and neutron pulse heights. Using CLYC, gamma energy pulses can be discriminated from the neutron signals by simple pulse height separation. For the cases of both LGB and LOS, careful pulse shape discrimination is needed to separate the gamma energy signals from neutron pulses. Both analog and digital methods have been applied to obtain a clear gamma and neutron energy spectrum in a mixed radiation field. A waveform digitizer manufactured by Agilent Technology Inc. has been successfully used to digitize the signal and separate the gamma and neutron signals to obtain a high gamma rejection ratio. These results along with some interesting data from a plastic (BC-408) and 3He dual gamma-neuron detector will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗