Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Visualization and Analysis-Oriented Reconstruction of Material Interfaces

Reconstructing boundaries along material interfaces from volume fractions is a difficult problem, especially because the under-resolved nature of the input data allows for many correct interpretations. Worse, algorithms widely accepted as appropriate for simulation are inappropriate for visualization. In this paper, we describe a new algorithm that is specifically intended for reconstructing material interfaces for visualization and analysis requirements. The algorithm performs well with respect to memory footprint and execution time, has desirable properties in various accuracy metrics, and also produces smooth surfaces with few artifacts, even when faced with more than two materials per cell.

97 MATHEMATICS AND COMPUTING↗

Fast and low-dose computed laminography using compressive sensing based technique

Computed laminography (CL) is well known for inspecting microstructures in the materials, weldments and soldering defects in high density packed components or multilayer printed circuit boards. The overload problem on x-ray tube and gross failure of the radio-sensitive electronics devices during a scan are among important issues in CL which needs to be addressed. The sparse-view CL can be one of the viable option to overcome such issues. In this work a numerical aluminum welding phantom was simulated to collect sparsely sampled projection data at only 40 views using a conventional CL scanning scheme i.e. oblique scan. A compressive-sensing inspired total-variation (TV) minimization algorithm was utilized to reconstruct the images. It is found that the images reconstructed using sparse view data are visually comparable with the images reconstructed using full scan data set i.e. at 360 views on regular interval. We have quantitatively confirmed that tiny structures such as copper and tungsten slags, and copper flakes in the reconstructed images from sparsely sampled data are comparable with the corresponding structure present in the fully sampled data case. A blurring effect can be seen near the edges of few pores at the bottom of the reconstructed images from sparsely sampled data, despite the overall image quality is reasonable for fast and low-dose NDT.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimized image acquisition for breast tomosynthesis in projection and reconstruction space

Breast tomosynthesis has been an exciting new development in the field of breast imaging. While the diagnostic improvement via tomosynthesis is notable, the full potential of tomosynthesis has not yet been realized. This may be attributed to the dependency of the diagnostic quality of tomosynthesis on multiple variables, each of which needs to be optimized. Those include dose, number of angular projections, and the total angular span of those projections. In this study, the authors investigated the effects of these acquisition parameters on the overall diagnostic image quality of breast tomosynthesis in both the projection and reconstruction space. Five mastectomy specimens were imaged using a prototype tomosynthesis system. 25 angular projections of each specimen were acquired at 6.2 times typical single-view clinical dose level. Images at lower dose levels were then simulated using a noise modification routine. Each projection image was supplemented with 84 simulated 3 mm 3D lesions embedded at the center of 84 nonoverlapping ROIs. The projection images were then reconstructed using a filtered backprojection algorithm at different combinations of acquisition parameters to investigate which of the many possible combinations maximizes the performance. Performance was evaluated in terms of a Laguerre-Gauss channelized Hotelling observer model-based measure of lesion detectability. The analysis was also performed without reconstruction by combining the model results from projection images using Bayesian decision fusion algorithm. The effect of acquisition parameters on projection images and reconstructed slices were then compared to derive an optimization rule for tomosynthesis. The results indicated that projection images yield comparable but higher performance than reconstructed images. Both modes, however, offered similar trends: Performance improved with an increase in the total acquisition dose level and the angular span. Using a constant dose level and angular span, the performance rolled off beyond a certain number of projections, indicating that simply increasing the number of projections in tomosynthesis may not necessarily improve its performance. The best performance for both projection images and tomosynthesis slices was obtained for 15-17 projections spanning an angular arc of {approx}45 deg. - the maximum tested in our study, and for an acquisition dose equal to single-view mammography. The optimization framework developed in this framework is applicable to other reconstruction techniques and other multiprojection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A second-order accurate finite volume scheme with the discrete maximum principle for solving Richards’ equation on unstructured meshes

Richards’s equation describes steady-state or transient flow in a variably saturated medium. For a medium having multiple layers of soils that are not aligned with coordinate axes, a mesh fitted to these layers is no longer orthogonal and the classical two-point flux approximation finite volume scheme is no longer accurate. Here, we propose new second-order accurate nonlinear finite volume (NFV) schemes for the head and pressure formulations of Richards’ equation. We prove that the discrete maximum principles hold for both formulations at steady-state which mimics similar properties of the continuum solution. The second-order accuracy is achieved using high-order upwind algorithms for the relative permeability. Numerical simulations of water infiltration into a dry soil show significant advantage of the second-order NFV schemes over the first-order NFV schemes even on coarse meshes. Since explicit calculation of the Jacobian matrix becomes prohibitively expensive for high-order schemes due to build-in reconstruction and slope limiting algorithms, we study numerically the preconditioning strategy introduced recently in Lipnikov et al. (2016) that uses a stable approximation of the continuum Jacobian. Lastly, numerical simulations show that the new preconditioner reduces computational cost up to 2–3 times in comparison with the conventional preconditioners.

97 MATHEMATICS AND COMPUTING↗

MO-FG-CAMPUS-IeP2-02: Effects of Metal On CT Size-Specific Dose Estimates

Purpose: To evaluate the accuracy of size-specific dose estimates (SSDE) in CT in the presence of simulated metal prostheses. Methods: Radiation dose in tissue (f-factor = 0.94) was measured at various chamber positions in a conventional nested CTDI phantom with nominal 0.5 inch metal rods inserted to simulate the presence of prosthetic implant(s). An average weighted tissue dose (AWTD) was calculated in a manner similar to CTDIw. Subsequent scans were performed with varying phantom diameter, number of metal rods and type of metal. The scan acquisition parameters were fixed for all such measurements (i.e. CTDIvol was constant). Axial CT images reconstructed both with and without a metal artifact reduction algorithm (SEMAR) were used to calculate the water-equivalent diameter (Dw) per AAPM TG Report 220. The Dw values were subsequently used to determine the SSDE from the known CTDIvol. In addition SSDE was also calculated from the effective diameter per AAPM TG Report 204. Accuracy of the calculated SSDE values were assessed by comparing to the AWTD measurements. Results: In the 32-cm diameter phantom the SSDE calculations from Dw (TG-220) were within ±1% of the AWTD measurements regardless of type of metal and number of metal rods while SSDE calculated from effective diameter (TG-204) overestimated the AWTD by 7–10%. In the 16-cm diameter phantom the SSDE calculations from Dw (TG-220) were within ±4% of the AWTD measurement. The Dw calculations used to determine SSDE varied by less than 0.2% between the images reconstructed with and without the metal artifact reduction algorithm. Conclusion: The TG-220 SSDE method can provide an accurate estimation of tissue dose in the presence of metal while TG-204 SSDE method overestimates the dose. The determination of Dw is independent of reconstruction algorithm.

60 APPLIED LIFE SCIENCES↗

Reconstruction of soot temperature and volume fraction profiles of an asymmetric flame using stereoscopic tomography

The present study attempts to reconstruct soot temperature and volume fraction distributions for the asymmetric diffusive flame using a tomography technique. A high-resolution camera equipped with a stereo adapter was employed to capture stereoscopic flame images, which were used to obtain monochromatic line-of-sight flame emission projections within the visible range. A matrix-decomposition-based least squares algorithm was introduced to reconstruct the emission intensity distributions in the flame sections. The retrieved intensities were used to infer local soot temperature and volume fraction. Numerical assessments show that for soot volume fraction measurement, the system signal-to-noise ratio should be larger than 62.5 dB. The proposed tomography system was found to be capable of symmetric and asymmetric flame measurements. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phillips-Tikhonov regularization with a priori information for neutron emission tomographic reconstruction on Joint European Torus

A method of tomographic reconstruction of the neutron emissivity in the poloidal cross section of the Joint European Torus (JET, Culham, UK) tokamak was developed. Due to very limited data set (two projection angles, 19 lines of sight only) provided by the neutron emission profile monitor (KN3 neutron camera), the reconstruction is an ill-posed inverse problem. The aim of this work consists in making a contribution to the development of reliable plasma tomography reconstruction methods that could be routinely used at JET tokamak. The proposed method is based on Phillips-Tikhonov regularization and incorporates a priori knowledge of the shape of normalized neutron emissivity profile. For the purpose of the optimal selection of the regularization parameters, the shape of normalized neutron emissivity profile is approximated by the shape of normalized electron density profile measured by LIDAR or high resolution Thomson scattering JET diagnostics. In contrast with some previously developed methods of ill-posed plasma tomography reconstruction problem, the developed algorithms do not include any post-processing of the obtained solution and the physical constrains on the solution are imposed during the regularization process. The accuracy of the method is at first evaluated by several tests with synthetic data based on various plasma neutron emissivity models (phantoms). Then, the method is applied to the neutron emissivity reconstruction for JET D plasma discharge #85100. It is demonstrated that this method shows good performance and reliability and it can be routinely used for plasma neutron emissivity reconstruction on JET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-489: 4-Years Experience of QA in TomoTherapy MVCT: What Do We Look Out For?

Purpose: To evaluate the QA results of TomoTherapy MVCT from March 2012 to February 2016, and to identify issues that may affect consistency in HU numbers and reconstructed treatment dose in MVCT. Methods: Monthly QA was performed on our TomoHD system. Phantom with rod inserts of various mass densities was imaged in MVCT and compared to baseline to evaluate HU number consistency. To evaluate treatment dose reconstructed by delivered sinogram and MVCT, a treatment plan was designed on a humanoid skull phantom. The phantom was imaged with MVCT and treatment plan was delivered to obtain the sinogram. The dose reconstructed with the Planned Adaptive software was compared to the dose in the original plan. The QA tolerance for HU numbers was ±30 HU, and ±2% for discrepancy between original plan dose and reconstructed dose. Tolerances were referenced to AAPM TG148. Results: Several technical modifications or maintenance activities to the system have been identified which affected QA Results: 1) Upgrade in console system software which added a weekly HU calibration procedure; 2) Linac or MLC replacement leading to change in Accelerator Output Machine (AOM) parameters; 3) Upgrade in planning system algorithm affecting MVCT dose reconstruction. These events caused abrupt changes in QA results especially for the reconstructed dose. In the past 9 months, when no such modifications were done to the system, reconstructed dose was consistent with maximum deviation from baseline less than 0.6%. The HU number deviated less than 5HU. Conclusion: Routine QA is essential for MVCT, especially if the MVCT is used for daily dose reconstruction to monitor delivered dose to patients. Several technical events which may affect consistency of this are software changes, linac or MLC replacement. QA results reflected changes which justify re-calibration or system adjustment. In normal circumstances, the system should be relatively stable and quarterly QA may be sufficient.

60 APPLIED LIFE SCIENCES↗

Electron beam diagnostic for profiling high power beams

A system for characterizing high power electron beams at power levels of 10 kW and above is described. This system is comprised of a slit disk assembly having a multitude of radial slits, a conducting disk with the same number of radial slits located below the slit disk assembly, a Faraday cup assembly located below the conducting disk, and a start-stop target located proximate the slit disk assembly. In order to keep the system from over-heating during use, a heat sink is placed in close proximity to the components discussed above, and an active cooling system, using water, for example, can be integrated into the heat sink. During use, the high power beam is initially directed onto a start-stop target and after reaching its full power is translated around the slit disk assembly, wherein the beam enters the radial slits and the conducting disk radial slits and is detected at the Faraday cup assembly. A trigger probe assembly can also be integrated into the system in order to aid in the determination of the proper orientation of the beam during reconstruction. After passing over each of the slits, the beam is then rapidly translated back to the start-stop target to minimize the amount of time that the high power beam comes in contact with the slit disk assembly. The data obtained by the system is then transferred into a computer system, where a computer tomography algorithm is used to reconstruct the power density distribution of the beam.

47 OTHER INSTRUMENTATION↗

Hydrodynamic and Radiographic Toolbox (HART)

With a multi-lab and university team, we propose to develop new methods for a Hydrodynamic and Radiographic Toolbox (HART) that will enable a fuller and more extensive use of experimental radiographic data towards better characterizing and reducing uncertainties in predictive modeling of weapons performance. We will achieve this by leveraging recent developments in areas of computational imaging, statistical and machine learning, and reduced order modeling of hydrodynamics. In terms of software practices, by partnering with XCP (RISTRA Project) we will conform to recent XCP standards that are inline with modern software practices and standards and ensure compatibility and ease of inter-operability with existing codes. Three new activities under this proposal include (a) the development and use of deep learning-based surrogates to accelerate reconstruction and variational inference of density fields from radiographs of hydrotests, (b) a model-data fusion strategy that couples deep learning-based density reconstructions with fast hydrodynamics simulators to better constrain the reconstruction, and (c) a method for treating asymmetries using techniques adopted from limited view tomography. All three new activities will be based on improved treatment of scatter, noise, beam spot movement, detector blur, and flat fielding in the forward model, and a use of sophisticated priors to aid in the re construction. The improvements to the forward model and improved algorithmic design of the reconstruction when complete will be contained in the iterative reconstruction code SHIVA—a code project that we have recently initiated. The many ways in which machine learning can be used in the reconstruction work will be contained in a code HERMES that has been initiated with DTRA support. For example, the significant levels of acceleration that will likely be achieved by the use of machine learning techniques will permit us (and are required) to quantify uncertainties in density retrievals. Next, the two-way coupling between density reconstruction and model-based simulation of the hydrodynamics will be contained in code EREBUS, and will permit a fuller realization of the potential of the data to constrain the hydrodynamic model and better address issues related to asymmetries in the problem. Finally, we anticipate that the better consistency with physics achieved in our reconstructions will allow them to be used by X-Division more so than today.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Nondestructive Evaluation of Concrete: Elastic Property Imaging Through Full-Waveform Inversion

Concrete is a vital material in construction—especially in the nuclear industry, where it is used in critical structures such as containment vessels. Over time, concrete can degrade due to harsh operational and environmental conditions, necessitating that its elastic properties be accurately evaluated to ensure structural integrity and safety. Traditional nondestructive evaluation methods such as ultrasound-based techniques often rely on simplifying assumptions that may not hold true for concrete. This paper presents an advanced ultrasound-based method that uses elastic full-waveform inversion (EFWI) to create detailed images of concrete’s mechanical properties. By accurately modeling wave behaviors such as scattering and reflection, we aim to overcome the limitations of conventional ultrasonic-based methods. In this work, the imaging problem involved reconstructing the various elastic properties of a heterogenous concrete block with three steel rebars embedded in it. The ultrasonic measurements were synthetically generated from multiple sources and receivers, and the reconstruction process was performed using a gradient-based optimization algorithm. Our approach leveraged EFWI to reconstruct high-resolution images of the pressure wave speed, shear wave speed, and density. Multiple misfit functions—including L2-norm, cross-correlation (CC), and L1-norm—combined with total variation (TV) regularization and parameter constraints using a Sigmoid function—were explored for the reconstruction. The results demonstrated that using the L1-norm misfit function in conjunction with TV regularization and Sigmoid constraints significantly improved the reconstruction quality in comparison to traditional methods. This approach provided clearer images with fewer artifacts and better captured background heterogeneity. Our findings highlight that, when properly designed, EFWI carries great potential for providing comprehensive, more accurate, and more reliable assessments of concrete conditions, as is crucial for the maintenance and safety of nuclear power plant structures.

97 - MATHEMATICS AND COMPUTING↗

A Pattern Recognition Algorithm for Quantum Annealers

Abstract The reconstruction of charged particles will be a key computing challenge for the high-luminosity Large Hadron Collider (HL-LHC) where increased data rates lead to a large increase in running time for current pattern recognition algorithms. An alternative approach explored here expresses pattern recognition as a quadratic unconstrained binary optimization (QUBO), which allows algorithms to be run on classical and quantum annealers. While the overall timing of the proposed approach and its scaling has still to be measured and studied, we demonstrate that, in terms of efficiency and purity, the same physics performance of the LHC tracking algorithms can be achieved. More research will be needed to achieve comparable performance in HL-LHC conditions, as increasing track density decreases the purity of the QUBO track segment classifier.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charged particle tracking with quantum annealing optimization

Abstract At the High Luminosity Large Hadron Collider (HL-LHC), traditional track reconstruction techniques that are critical for physics analysis will need to be upgraded to scale with track density. Quantum annealing has shown promise in its ability to solve combinatorial optimization problems amidst an ongoing effort to establish evidence of a quantum speedup. As a step towards exploiting such potential speedup, we investigate a track reconstruction approach by adapting the existing geometric Denby-Peterson (Hopfield) network method to the quantum annealing framework for HL-LHC conditions. We develop additional techniques to embed the problem onto existing and near-term quantum annealing hardware. Results using simulated annealing and quantum annealing with the D-Wave 2X system on the TrackML open dataset are presented, demonstrating the successful application of a quantum annealing algorithm to the track reconstruction challenge. We find that combinatorial optimization problems can effectively reconstruct tracks, suggesting possible applications for fast hardware-specific implementations at the HL-LHC while leaving open the possibility of a quantum speedup for tracking.

97 MATHEMATICS AND COMPUTING↗

Phase Space Reconstruction from Accelerator Beam Measurements Using Neural Networks and Differentiable Simulations

Characterizing the phase space distribution of particle beams in accelerators is a central part of accelerator understanding and performance optimization. However, conventional reconstruction-based techniques either use simplifying assumptions or require specialized diagnostics to infer high-dimensional (> $2D$) beam properties. In this Letter, we introduce a general-purpose algorithm that combines neural networks with differentiable particle tracking to efficiently reconstruct high-dimensional phase space distributions without using specialized beam diagnostics or beam manipulations. Furthermore, we demonstrate that our algorithm accurately reconstructs detailed 4D phase space distributions with corresponding confidence intervals in both simulation and experiment using a single focusing quadrupole and diagnostic screen. This technique allows for the measurement of multiple correlated phase spaces simultaneously, which will enable simplified 6D phase space distribution reconstructions in the future.

47 OTHER INSTRUMENTATION↗

Feasibility of volume-of-interest (VOI) scanning technique in cone beam breast CT - a preliminary study

This work is to demonstrate that high quality cone beam CT images can be generated for a volume of interest (VOI) and to investigate the exposure reduction effect, dose saving, and scatter reduction with the VOI scanning technique. The VOI scanning technique involves inserting a filtering mask between the x-ray source and the breast during image acquisition. The mask has an opening to allow full x-ray exposure to be delivered to a preselected VOI and a lower, filtered exposure to the region outside the VOI. To investigate the effects of increased noise due to reduced exposure outside the VOI on the reconstructed VOI image, we directly extracted the projection data inside the VOI from the full-field projection data and added additional data to the projection outside the VOI to simulate the relative noise increase due to reduced exposure. The nonuniform reference images were simulated in an identical manner to normalize the projection images and measure the x-ray attenuation factor for the object. Regular Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the 3D images. The noise level inside the VOI was evaluated and compared with that of the full-field higher exposure image. Calcifications phantom and low contrast phantom were imaged. Dose reduction was investigated by estimating the dose distribution in a cylindrical water phantom using Monte Carlo simulation based Geant4 package. Scatter reduction at the detector input was also studied. Our results show that with the exposure level reduced by the VOI mask, the dose levels were significantly reduced both inside and outside the VOI without compromising the accuracy of image reconstruction, allowing for the VOI to be imaged with more clarity and helping to reduce the breast dose. The contrast-to-noise ratio inside the VOI was improved. The VOI images were not adversely affected by noisier projection data outside the VOI. Scatter intensities at the detector input were also shown to decrease significantly both inside and outside the VOI in the projection images, indicating potential improvement of image quality inside the VOI and contribution to dose reduction both inside and outside the VOI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A fast reconstruction method of the dense point-cloud model for cultural heritage artifacts based on compressed sensing and sparse auto-encoder

Since the point cloud data of cultural heritage artifacts obtained by the laser scanner is enormous and dense, these lead to a large quantity of network resource for storing, processing, and transmission. This paper provided a fast reconstruction method of the dense point cloud model for cultural relics based on sparse auto-encoder and compressed sensing. Firstly, the octree method based on the hash function was utilized to extract local features and remove redundant points. Secondly, the point cloud, which can be seen as the 3D geometric signal, is projected to the discrete Laplacian sparse basis via the point cloud adjacency matrix. Then, aiming at the bottleneck of slow recovery caused by tremendous scale of inverse problem based on compressed sensing theory, the sparse auto-encoder was applied to reduce the dimension and speed up the recovery. Finally, the OMP algorithm was applied to reconstruct 3D point cloud model based on the stochastic Gauss matrix. In order to test the performance of our methods, the 3D point cloud model of terracotta warriors and horses head were used. And the experimental results demonstrated that our approach can obviously accelerate the process of reconstruction of the dense point cloud model for the cultural heritage artifacts and ensure the recovery accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Description and Performance of Track and Primary-Vertex Reconstruction with the CMS Tracker

A description is provided of the software algorithms developed for the CMS tracker both for reconstructing charged-particle trajectories in proton-proton interactions and for using the resulting tracks to estimate the positions of the LHC luminous region and individual primary-interaction vertices. Despite the very hostile environment at the LHC, the performance obtained with these algorithms is found to be excellent. For tbar t events under typical 2011 pileup conditions, the average track-reconstruction efficiency for promptly-produced charged particles with transverse momenta of p(T) > 0.9GeV is 94% for pseudorapidities of |η| < 0.9 and 85% for 0.9 < |η| < 2.5. The inefficiency is caused mainly by hadrons that undergo nuclear interactions in the tracker material. For isolated muons, the corresponding efficiencies are essentially 100%. For isolated muons of p(T) = 100GeV emitted at |η| < 1.4, the resolutions are approximately 2.8% in p(T), and respectively, 10μm and 30μm in the transverse and longitudinal impact parameters. The position resolution achieved for reconstructed primary vertices that correspond to interesting pp collisions is 10–12μm in each of the three spatial dimensions. The tracking and vertexing software is fast and flexible, and easily adaptable to other functions, such as fast tracking for the trigger, or dedicated tracking for electrons that takes into account bremsstrahlung.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗