Search NASA⌕ Search

SEARCH · Search NASA

Results for “Return Temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Permanent magnets for the return loop of the Cornell-Brookhaven energy recovery linac test accelerator

214 neodymium permanent magnets have been manufactured for the return loop of the CBETA multi-turn ERL at Cornell University. There are 5 types of quadrupole and combined-function gradient magnets using a variant of the circular Halbach design. These are made out of NdFeB material and glued into an aluminium housing with water channels for temperature stabilisation. The NdFeB wedges and magnet construction were done by outside companies, while the final “tuning” using inserts containing 64 iron rods per magnet was done at BNL over a period of about 6 months. Average relative field errors of 2.2×10 -4 were achieved on the beam region. The magnet strengths vary by type but are of order 10 T/m for quadrupole component and up to 0.3 T for the dipole. This paper reports on the field quality and timeline achieved in this production process

43 PARTICLE ACCELERATORS↗

Wind enhanced planetary escape - Collisional modifications

Effects of collisions and finite winds characteristic of a highly perturbed atmosphere on the thermal escape of terrestrial hydrogen and helium are investigated using a Monte Carlo approach. The limiting cases of vertical and horizontal winds are considered, and the relaxation layer between the collisionless exosphere and the collision-dominated thermosphere is modeled as a plane-parallel slab of given column density, depth, and atmospheric density. For both gases, the upwardly injected flux at the base of the relaxation layer is compared with the returning downward flux distribution at the same location; the technique is also applied to the atmosphere of Titan. The results show that inclusion of collisions in the escape model for terrestrial hydrogen with winds effectively throttles the escape process, that collisional throttling is negligible for helium when the exobase temperature is at least 5000 K, and that the escape of a planetary-atmosphere constituent depends on the ratio of its gravitational and kinetic energies as well as on the ratio of its mass to that of the background gas.

Curtis, S. A.↗

Mars - A contamination potential?

Three regions on Mars, Solis Lacus, Noachis-Hellespontus, and the Syrtis Major border areas, would appear to have generally less hostile environments than at the Viking lander sites. Significant soil moisture may extend to within about 1 cm of the surface. Water vapor pressures within the pore spaces may be near saturation, and brines may be physically segregated from pockets of relatively pure H2O. Temperatures reach above 0 C during southern spring and summer, with peak temperatures reaching +22 C. These regions should contain fewer oxidants, and primary synthesis of organics may occur. The potential for contamination of these sites by microbes transported from existing spacecraft should be assessed. The adequacy of proposed new planetary protection procedures for possible future United States Mars Surface Sample Return missions should also be assessed in light of these findings.

Huguenin, R. L.↗

A comparison of 8.415-, 32.0- and 565646-GHz deep space telemetry links

An economic and performance comparison is made of spacecraft telecommunication links at 8.415, 32.0, and 565646 GHz (0.53-micron wavelength) for the return of 3.43 x 10 to the 11th power bits from a Saturn Orbiter/Titan Probe mission in year 2000. Technical performance and costs for both ends of the links are included. Spacecraft antenna or telescope efficiencies, pointing losses, ground-based or Earth-orbiting relay terminals efficiencies, noise temperatures, recurring and nonrecurring engineering, and maintenance and operations costs are modeled. Weather effects, dc-to-RF or laser power conversion efficiencies, gravity and other environment distortions gain reductions, and the cost of pointing and tracking are analyzed. The effort is focused primarily on the microwave frequency links. There are large uncertainties in the cost results, but conclusions indicate that for a mid-1990's launch, the Ka-band system is as cost effective as X-band. The Ka-band system has a data rate advantage as compared to the X-band system for the same dc power input to the spacecraft. The magnitude of the advantage is a complex function of the weather at the DSN stations and the elevation angle of the ground antenna. A simple numerical comparison of the advantage is difficult and curves are provided. The optical frequency link is more costly based on the launch-to-orbit costs for the orbiting terminal. A more detailed study of the optical system is recommended to quantify astrometric tracking benefits and improve the accuracy of the cost estimate.

Dickinson, R. M.↗

The Capillary Pumped Loop (CPL) GAS experiment G-471

The Capillary Pumped Loop (CPL) experiment, 6-471 is a thermal control system with high density heat acquisition and transport capability. The CPL consists of two capillary pumped evaporators with integral heaters, a fluid loop charged with ammonia (NH3), a condenser plate (heat sink), and various control electronics. The purpose of the experiment is to demonstrate the capability of a capillary pumped system under zero gravity conditions for use in the thermal control of large scientific instruments, advanced orbiting spacecraft, and space station components. A unique feature of the CPL is the capillary pumps, which contain no moving parts. Each pump contains a wick of porous material which is saturated with the working fluid (anhydrous ammonia). As heat is added to the fluid, it evaporates and travels to the condenser, thus transporting the heat (via the latent heat of vaporization) from the heat source to its sink at nearly a constant temperature. The evaporation process produces the pressure gradient or pumping action that circulates the fluid. This is the same principal that plants and trees use to transport water and nutrients from their roots to their leaves against gravity. The difference is that the CPL employs a closed system to return the fluid directly to the pumps, whereas "Mother Nature'' has an open system where the fluid is indirectly returned to the roots by condensation of water from the clouds in the form of rain. It should be noted that the CPL experiment was the first flight of a thermal control system of this type. It was also the first shuttle experiment from the Space Station Advanced Development Program.

Dan Butler↗

Optical Systems Design for a Stratospheric Lidar System

The optical systems for the transmitter and receiver of a high-power lidar for stratospheric measurements have been designed and analyzed. The system requirements and design results are presented and explained. An important and driving factor of this design was the requirement for a small image diameter in the plane of an optical chopper to allow the high-intensity lidar returns from the lower atmosphere to be shielded from the detection system. Some results relevant to the optical performance of the system are presented. The resulting system has been constructed and is now in operation at the Mauna Loa Observatory, Hawaii, and is making regular measurements of stratospheric ozone, temperature, and aerosol profiles.

McDermid, I. Stuart↗

Radicals and Reservoirs in the GMI Chemistry and Transport Model: Comparison to Measurements

The most important use of atmospheric chemistry and transport models is to predict the future composition of the atmosphere. The amounts of gases like chlorofluorcarbons, methyl bromide, nitrous oxide and methane are changing and the stratospheric ozone layer will change because these gases are changing. Methyl bromide, nitrous oxide and methane all have natural sources, and also change because of human activity. Chlorofluorcarbons are man-made gases; these are known to decrease stratospheric ozone and future production is banned. They are long-lived gases, and many decades will pass before they are insignificant in the atmosphere. The models are used to predict changes in ozone and other gases; this is a straightforward application. The models must be also tested using observations for the present day atmosphere. This is a challenging task, because the model contains more than 50 species and more than 150 chemical reactions. Data from satellites, ground stations, aircraft and balloons are used to evaluate the model. Different models that are used in international assessments produce different results; in the most recent assessment some predict that ozone will return to 1980 levels by 2025 and others predict that this will not happen until 2050. Since all the parts of the models are conceptually the same, there must be differences in implementation that produce these differences, This work takes a single model, two different sets of winds and temperatures, and repeats the same prediction for the future. Here we compare the results for these two simulations with many observations. The purpose is to identify differences in the model results for the present atmosphere that will lead to different predictions. This sort of controlled comparison will reduce uncertainty in the predictions for stratospheric ozone.

Douglas, Anne R.↗

Forward Technology Solar Cell Experiment First On-Orbit Data

This paper presents first on orbit measured data from the Forward Technology Solar Cell Experiment (FTSCE). FTSCE is a space experiment housed within the 5th Materials on the International Space Station Experiment (MISSE-5). MISSE-5 was launched aboard the Shuttle return to flight mission (STS-114) on July 26, 2005 and deployed on the exterior of the International Space Station (ISS). The experiment will remain in orbit for nominally one year, after which it will be returned to Earth for post-flight testing and analysis. While on orbit, the experiment is designed to measure a 36 point current vs. voltage (IV) curve on each of the experimental solar cells, and the data is continuously telemetered to Earth. The experiment also measures the solar cell temperature and the orientation of the solar cells to the sun. A range of solar cell technologies are included in the experiment including state-of-the-art triple junction InGaP/GaAs/Ge solar cells from several vendors, thin film amorphous Si and CuIn(Ga)Se2 cells, and next-generation technologies like single-junction GaAs cells grown on Si wafers and metamorphic InGaP/InGaAs/Ge triple-junction cells. In addition to FTSCE, MISSE-5 also contains a Thin-Film Materials experiment. This is a passive experiment that will provide data on the effect of the space environment on more than 200 different materials. FTSCE was initially conceived in response to various on-orbit and ground test anomalies associated with space power systems. The Department of Defense (DoD) required a method of rapidly obtaining on orbit validation data for new space solar cell technologies, and NRL was tasked to devise an experiment to meet this requirement. Rapid access to space was provided by the MISSE Program which is a NASA Langley Research Center program. MISSE-5 is a completely self-contained experiment system with its own power generation and storage system and communications system. The communications system, referred to as PCSat, transmits and receives in the Amateur Radio band providing a node on the Amateur Radio Satellite Service. This paper presents an overview of the various aspects of MISSE-5 and a sample of the first measured on orbit data.

Walters, R. J.↗

Towards Net-Zero: Nuclear-Assisted Waste Biomass to Liquid Fuel in Eastern Idaho

A nuclear assisted carbon negative hybrid energy process that enables production of synthetic bio-crude oil and biochar from Eastern Idaho waste biomass is proposed. The process integrates nuclear powered electricity with high temperature steam electrolysis and biomass hydropyrolysis. The bio-crude oil is of sufficient composition and blended with traditional crude oil at a refinery. Hydrogen from the electrolyzer is pressurized and inserted into the pyrolyzer. Non condensable gases generated in the hydropyrolysis process are burned with oxygen from the electrolyzer to produce heat for the electrolyzer, biomass dryer, and pyrolyzer. The biochar is returned to the soil via fertilizer application and remains there for thousands of years. Since the total process uses nuclear generated electricity, the carbon in the biochar is ultimately sequestered from the atmosphere, thus making the process carbon negative. Using Eastern Idaho wheat or barley straw, this hybrid energy process has the potential to provide an alternative petroleum source. Two options exist for the system design: 1) send electricity from the nuclear plant and straw to a chemical processing plant to produce the bio-crude and biochar, 2) construct the biomass processing facility near the nuclear plant to allow use of nuclear-generated process heat to drive the chemical. Process model description and results are discussed. The process is sized to produce gasoline and diesel at the rate that the INL uses every day for fleet usage.

09 BIOMASS FUELS↗

Development of an accelerator-based neutron source to prototype Mo-99 production, Part II: A liquid LBE loop under a high vacuum

To provide US domestic supply of Mo-99 without using high-enriched uranium (HEU), a subcritical uranium target assembly (UTA) is irradiated by an accelerator-based neutron source to create Mo-99 through fission. Part I of this work discusses the design of a liquid lead–bismuth eutectic (LBE) windowless target for an accelerator-based neutron source development. Part II discusses how to couple this windowless target to an accelerator operating at an ultra-high vacuum and the subcritical UTA cooled by water at room temperature. Due to the windowless design of the target, the liquid LBE flow shares an ultra-high vacuum (<1.3 × 10 -7 Pa or 10 -9 Torr) space with the accelerator. As a result of this shared vacuum space, the LBE system must operate at a high vacuum (10 -3 ~10 -6 Pa or 10 -5 ~10 -8 Torr). A magnetic rotary motion feedthrough unit utilizes magnetic fluid to allow rotation of the pump while maintaining a high vacuum environment. Prior to testing the LBE system under vacuum, a pump curve measurement is performed to estimate flowrate in the system. This measurement also generates data on orifice loss coefficients, which are compared to correlations in literature. The second experiment investigates vacuum level in the LBE system during operation. High vacuum is maintained (10 -3 ~10 -5 Pa or 10 -5 ~10 -7 Torr) during system operation, and a residual gas analyzer (RGA) scan shows that partial pressures of residual gases in the LBE system lower over the duration of LBE system operations. The third experiment investigates the gravity driven liquid LBE flowing out of the target chamber in the return line, which is partially full. If the liquid LBE is not drained quickly enough, flooding in the target chamber could occur. The coefficient n in the Manning equation is found to be around 0.008 s/m 1/3 . The last experiment performed is a demonstration that a vacuum jacket could provide sufficient thermal insulation to allow coupling between 300 °C LBE loop and a water tank at room temperature. In conclusion, the results from these experiments have influenced the development of the neutron source for the future commercial scale Mo-99 production system.

43 PARTICLE ACCELERATORS↗

Preconceptual Designs of Coupled Power Delivery between a 4-Loop PWR and 100-500 MWe HTSE Plants

This study develops a preconceptual design for the integration between a large-scale high-temperature electrolysis facility and a NPP. Two hydrogen facility sizes are considered: 100 MWnom and 500 MWnom. Both steam supply designs use cold reheat steam extraction as a heat source. A reboiler inside the protected area of the power plant transfers steam heat to the demineralized water supply for the hydrogen plant. After the heat transfer, the extracted steam condenses and returns to the condenser while the process steam routes out of the protected area to the electrolyzers. Electrical power is tapped off from the high voltage side of the GSU transformer, where it is then transported via a 345-kV transmission line to the hydrogen facility. Circuit breakers and disconnects are located at both ends of the transmission line. Step down transformers and miscellaneous switchgear/buses are located at the end of the transmission line inside the HTEF boundary. Control capabilities for the steam interfacing equipment and electrical dispatch are accessible from the Main Control Room, and protective relays for the transmission line are located inside the Relay Room. Computer modeling was performed for the thermal and electrical designs. PEPSE analysis provided the steady-state parameters for thermal extraction from the turbine cycle. These parameters were used to inform transients and size equipment in combination with Applied Flow Technology (AFT) Arrow and AFT Fathom modeling for steam and water piping, respectively. Electrical transients were analyzed using PSCAD. An ETAP model was used to evaluate power flow and short circuit, which enabled the sizing of transformers and protective equipment. A cost estimate was developed for both integration designs when considering plant separation distances of 250 m and 500 m. From these estimates, the modifications for thermal and electrical interfacing of a first-of-a-kind nuclear-integrated hydrogen facility are anticipated to cost between $60–250/kWnom., where the subscript “nom” refers to the nominal size of the hydrogen plant. On a thermal power basis, the thermal power has a cost of approximately $8/MWth for a 500 MWnom high temperature electrolysis plant located 500 m distant from the NPP. That value decreases to approximately $7.5/MWth for a 250 m separation distance between the hydrogen plant and the NPP. This value is lower than previous estimates of the cost of heat extracted from NPPs primarily because in this work the steam is extracted from cold reheat instead of the main steam line, which reduces the cost of the dispatched steam by approximately $3.5/MWth. Nuclear steam extraction can provide a profit avenue for many plants and is not restricted to hydrogen production. Ammonia production, oil refining, and paper production, among other industrial processes all require thermal energy, which can be provided by NPPs. Future work should look further at the details of thermal extraction for a variety of use cases. This can include increased levels of extraction and multiple simultaneous users. Additionally, site-specific studies should be performed to develop industry experience and improve cost accuracy.

08 HYDROGEN↗

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 1 – Steady state modeling and speed ratio selection

Helium cryogenic systems which can provide cooling below the normal boiling point of helium (approximately 4.2 K) are often required by superconducting radio-frequency niobium resonators utilized in modern high-energy particle accelerators. Achieving temperatures below 4.2 K generally involves operating a cryogenic vessel with liquid helium under sub-atmospheric conditions, thereby lowering the saturation pressure and corresponding saturation temperature. Over the last several decades, multi-stage cryogenic centrifugal compressor trains (CC’s) have been operated efficiently and reliably within large-scale cryogenic systems to continuously evacuate helium vapor generated by a device within the vessel, maintaining sub-atmospheric conditions in the vessel while pressurizing the return vapor to above atmospheric conditions. Traditionally, these CC systems have been operated using empirically derived control philosophies and insight gathered from previous operational experience. Recent efforts at the Facility for Rare Isotope Beams (FRIB) have been aimed at the development of a theoretical basis to characterize the operation of multi-stage cryogenic centrifugal compressor train and utilizing predictive model results to generate control parameters. The objective of this research was identifying operational points which adequately balance cryogenic system efficiency, stability, and overall ease of operation. Furthermore, this manuscript provides an overview of the predictive model development, characterization of the FRIB cryogenic centrifugal compressors and implementation of the predicted performance results during steady-state system operation.

Compressor train control↗

Specification of EBR-II Contact Profilometry Data

All contact profilometry data stored in FIPD was originally measured using the HFEF vertical contact profilometer, which was an electronic gauge to measure the diameter profile of an element or capsule continuously over the region of interest. The element could be rotated as it passed through the probes if the wire wrap was not to be removed and the element could be returned to reactor for further irradiation. If the wire wrap was removed, the element could be drawn vertically through the probes, rotated, and the process repeated. In this way any cladding ovality could be observed. Figure 1 shows the setup used to measure the fuel pin diameter profile. The ambient temperature during the measurement was ~21-23 ºC. The cladding temperature during the measurement is considered to be similar to the ambient temperature by assuming the fuel decay heat did not impact the cladding temperature. Two documents contain most of the important details about contact profilometry measurements. The first one is the operational manual of the contact profilometer (title: Element contact profilometer operation and maintenance, HFEF/N OMM 4326, DOC. NO. W0202-0007-SA-01). This manual provides: (1) description of the contact profilometer including the functions of each component (support stage, sensing head, control system, and calibration standards, etc.); (2) step-by-step guidance on calibrations, operations, and measurements; and (3) maintenance procedures and other details of the contact profilometer. The second document is a publicly accessible report entitled “A Fuel-element Profilometer for the HFEF.” This report describes the development of the contact profilometer, including the design requirements, features, and details of each component, as well as the acceptance tests for the built system. This document is important because it reports the uncertainties of the measurements with detailed deduction procedures. The reported uncertainties should apply to all hard-copy contact profilometry data in FIPD. Some key information about contact profilometry measurements was extracted from these two documents. Combining the information with other sources, a specification for interpretating the contact profilometry data in FIPD was established.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ice nucleating particle concentrations at Macquarie Island, 2017/8

These data list ice nucleating particle (INP) number concentrations active in the immersion freezing mode. Aerosol filters were collected during late March 2017 to March 2018 as part of the Macquarie Island Cloud and Radiation Experiment (MICRE), located at the Australian Antarctic Division's Macquarie Island station. Collections were made over alternating periods of 48 and 72 hours using open-faced polycarbonate filters that were approximately 4 m MSL, sited near the main AAD station on the island, at -54.4997 deg latitude and 158.9344 deg longitude. The volume of air filtered ranged from 5000 to 60000 volumetric liters per filter sample. Filters were stored and returned frozen to Colorado State University (CSU), where immersion freezing measurements over a range from 0 to -28 C were made using the CSU Ice Spectrometer (IS). Collected particles from each filter were resuspended in filtered, deionized water, and then dispensed into the IS and cooled to obtain cumulative INP temperature spectra. Aliquots of suspensions from selected samples were also heat treated (95 C for 20 min) to denature and deactivate biological INPs, and digested in 10% H2O2 at 95 C under UV-B for 20 min to remove all organic carbon INPs, prior to measurement using the IS.

54 ENVIRONMENTAL SCIENCES↗

MARCUS Ice Nucleating Particle Measurements (revised 7/2020)

These data list ice nucleating particle (INP) number concentrations active in the immersion freezing mode. Aerosol filters were collected during 4 voyages of the Aurora Australis vessel from 02 November 2017 to 22 March 2018, as part of the Measurements of Aerosols, Radiation and Clouds over the Southern Ocean (MARCUS) study. These voyages transected the Southern Ocean from Hobart, Tasmania to four Australian Antarctic Division stations, including three in Antarctica. Collections were made over alternating periods of 24 and 48 hours using open-faced polycarbonate filters that were approximately 18 m MSL, sited near the AOS trailer and other AMF measurements. The volume of air filtered ranged from 19000 to 38000 standard liters per filter sample. Filters were stored and returned frozen to Colorado State University (CSU), where immersion freezing measurements over a range from 0 to -28 degC were made using the CSU Ice Spectrometer (IS). Collected particles from each filter were resuspended in filtered, deionized water, and then dispensed into the IS and cooled to obtain cumulative INP temperature spectra. Aliquots of suspensions from selected samples were also heat treated (95 degC for 20 min) to denature and deactivate biological INPs, and digested in 10% H2O2 at 95 degC under UV-B for 20 min to remove all organic carbon INPs, prior to measurement using the IS.

54 ENVIRONMENTAL SCIENCES↗

Characteristics of capacitor-type micrometeoroid flux detectors when impacted with simulated micrometeoroids

A series of impact tests are described and data presented which characterize the operation of the capacitor-type micrometeoroid flux detectors used on the Meteoroid Technology Satellite (MTS). Capacitor-type detectors with silicon dioxide dielectric thickness of 0.4 and 1.0 microns were tested in the micrometeoroid impact simulator at the Langley Research Center, a 4-MV Van de Graaff electrostatic accelerator. The carbonyl iron projectiles were from 0.5 to 5.0 microns in diameter with velocities from 4 to 10.0 km/sec. The detector bias voltage was varied from -20 to -60 V; some tests were at detector temperatures of 90 C to -100 C; and the angle of impact varied from 0 deg to 75 deg from the normal to the detector. These tests showed that: (1) the detector operation is reliable when the bias voltage is greater than 30 V; (2) after an impact the detector returns to its original condition with an insignificant loss of active area; and (3) the sensitivity of the detector is inversely proportional to the detector thickness. The test results suggest a theoretical model in which the signal is an arc triggered by the impacting projectile, and the detector bias voltage must be high enough to insure that an arc will form.

Kassel, P. C., Jr.↗

Acoustic sensor engineering evaluation test report

Two types of one-inch diameter sound pressure level sensors, which are candidates for monitoring ambient noise in the shuttle orbiter crew compartment during rest periods, were exposed to temperature, passive humidity, and vibration. One unexposed sensor of each type served as a reference unit. Except for the humidity exposures, each of the three capacitive microphones was individually tested in sequence with the essential voltage power supply and preamplifier. One unit exibited anomalous characteristics after the humidity exposure but returned to normal after being dried in an oven at 115 deg for two hours. Except for the humidity exposures, each of the three piezoelectric microphones was individually tested with a laboratory type amplifier. Two apparent failures occurred during these tests. The diaphragm on one was found ruptured after the fourth cycle of the humidity test. A second sensor showed an anomaly after the random vibration tests at which time its sensitivity was consistent at about one-half its former value.

Phillips, E. L., Jr.↗

Anion permselective membrane

The synthesis and fabrication of polymeric anion permselective membranes for redox systems are discussed. Variations of the prime candidate anion membrane formulation to achieve better resistance and/or lower permeability were explored. Processing parameters were evaluated to lower cost and fabricate larger sizes. The processing techniques to produce more membranes per batch were successfully integrated with the fabrication of larger membranes. Membranes of about 107 cm x 51 cm were made in excellent yield. Several measurements were made on the larger sample membranes. Among the data developed were water transport and transference numbers for these prime candidate membranes at 20 C. Other work done on this system included characterization of a number of specimens of candidate membranes which had been returned after service lives of up to sixteen months. Work with new polymer constituents, with new N.P.'s, catalysts and backing fabrics is discussed. Some work was also done to evaluate other proportions of the ingredients of the prime candidate system. The adoption of a flow selectivity test at elevated temperature was explored.

Hodgdon, R. B.↗