Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Development of polymer 'chips' used in medical diagnostics

In recent years, there has been growing interest in creating bio-inspired devices that feature artificial bilayer lipid membranes (BLM), or lipid bilayers. These membranes can be tailored to mimic the structure and transport properties of cellular walls and can be used to selectively transport ions and other species between aqueous volumes. One application of this research is the formation of a standardized BLM contained within a portable and disposable housing for use in medical diagnostics. This concept utilizes a flexible polymer 'chip' that has internal compartments for housing both an organic solvent and an aqueous solution, which contains phospholipid molecules, proteins, and specific analyte molecules. The formation of a BLM within the chip enables integration of the chip into an electronic reader to perform diagnostic measurements of the sample. A key element of the bilayer formation process requires a single aqueous volume to first be separated into multiple volumes such that it can then be reattached to form a bilayer at the interface. This process, called the regulated attachment method, relies on the geometry of the deformable 'chip' to separate and reattach the aqueous contents held inside by opening and closing an aperture that divides adjacent compartments through the application of mechanical force. The purpose of this research is to develop an optimized chip that provides a controllable method for initially separating the aqueous phase via dynamic excitation. This study focuses on two specific aspects: designing an efficient excitation method for separating the aqueous volume, and optimizing the geometry of the chip to decrease the required input energy and better target the location and duration of the separation. Finite Element (FE) models are used to optimize the chip geometry and to identify suitable excitation signals. A series of experimental studies are also presented to validate the FE models.

42 ENGINEERING↗

Production of Particle Reference and Quality Control Materials

Maintaining the superior performance of new analytical instrumentation and pushing the boundaries of ever-smaller particle analysis by methods such as secondary ion mass spectrometry (SIMS) has become limited by the availability of certified particle standards for calibration, quality control, and validation. To meet this growing demand for a reliable and universal approach to the generation of uranium particle reference material, the Pacific Northwest National Laboratory (PNNL) and Savannah River National Laboratory (SRNL) are collaborating on a joint venture that establishes a number of chemical pathways to the fabrication, purification, and stabilization of uranium particle material to within a fixed particle size range, and well-characterized isotopics. PNNL particle standards are designed and tailored to meet the criteria essential to the calibration and benchmarking of instruments used in both the non-destructive and destructive assay of particulate material, typically collected from environmental swipe sampling. Previous testing and optimization of this colloidal approach to particulate material has centred on tight size distributions, singular composition and density, uniform morphology, and tailored isotopic abundances. Extensive validation of this material has since been performed, both at the National Institute of Standards and Technology (NIST) and the International Atomic Energy Agency (IAEA), demonstrating its suitability for quality control needs of large geometry (LG)-SIMS analysis. Building on this momentum, the production of low-enriched uranium particle reference material, with specially tailored isotopics, has moved from development to full operation. Herein, various aspects of the production cycle will be discussed, including detailed accounts of the technical methodologies being employed, as well as insights into the sample characterization and acceptance testing requirements.

Nuclear Safeguards, Particle Standards, IAEA↗

Dirac-Born-Infeld inflation using a one-parameter family of throat geometries

We demonstrate the possibility of examining cosmological signatures in the Dirac-Born-Infeld (DBI) inflation setup using the BGMPZ solution, a one-parameter family of geometries for the warped throat which interpolate between the Maldacena-Nunez and Klebanov-Strassler solutions. The warp factor is determined numerically and is subsequently used to calculate cosmological observables, including the scalar and tensor spectral indices, for a sample point in the parameter space. As one moves away from the Klebanov-Strassler (KS) solution for the throat, the warp factor is qualitatively different, which leads to a significant change for the observables, but also generically increases the non-Gaussianity of the models. We argue that the different models can potentially be differentiated by current and future experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Learning Only on Boundaries: A Physics-Informed Neural Operator for Solving Parametric Partial Differential Equations in Complex Geometries

Recently, deep learning surrogates and neural operators have shown promise in solving partial differential equations (PDEs). However, they often require a large amount of training data and are limited to bounded domains. In this work, we present a novel physics-informed neural operator method to solve parameterized boundary value problems without labeled data. By reformulating the PDEs into boundary integral equations (BIEs), we can train the operator network solely on the boundary of the domain. This approach reduces the number of required sample points from $O(N^d)$ to $O(N^{d-1}$), where $d$ is the domain’s dimension, leading to a significant acceleration of the training process. Additionally, our method can handle unbounded problems, which are unattainable for existing physics-informed neural networks (PINNs) and neural operators. Finally, our numerical experiments show the effectiveness of parameterized complex geometries and unbounded problems.

97 MATHEMATICS AND COMPUTING↗

Unraveling shock-induced chemistry using ultrafast lasers

The exquisite time synchronicity between shock and diagnostics needed to unravel chemical events occurring in picoseconds has been achieved using a shaped ultrafast laser pulse to both drive the shocks and interrogate the sample via a multiplicity of optical diagnostics. The shaped laser drive pulse can produce well-controlled shock states of sub-ns duration with sub-10 ps risetimes, sufficient for investigation offast reactions or phase transformations in a thin layer with picosecond time resolution. The shock state is characterized using ultrafast dynamic ellipsometry (UDE) in either planar or Gaussian spatial geometries, the latter allowing measurements of the equation of state of materials at a range of stresses in a single laser pulse. Time-resolved processes in materials are being interrogated using UDE, ultrafast infrared absorption, ultrafast UV/visible absorption, and femtosecond stimulated Raman spectroscopy. Using these tools we showed that chemistry in an energetic thin film starts only after an induction time of a few tens of ps, an observation that allows differentiation between proposed shock-induced reaction mechanisms. These tools are presently being applied to a variety of energetic and reactive sample systems, from nitromethane and carbon disulfide, to microengineered interfaces in tunable energetic mixtures. Recent results will be presented, and future trends outlined.

47 OTHER INSTRUMENTATION↗

SU-E-J-62: Estimating Plausible Treatment Course Dose Distributions by Accounting for Registration Uncertainty and Organ Motion

Purpose: Dose accumulation following deformable image registration (DIR) is challenging. In this study, we used a statistical sampling approach, which takes into account both DIR uncertainties and patient-specific organ motion, to study the distribution of possible true dose distributions. Methods: The study included ten patients (six CT scans/patient) treated with radiotherapy for prostate cancer. For each patient, the planned dose was re-calculated on the repeated geometries, following rigid registration based on fiducial markers. The dose re-calculated on the first CT served as our snapshot dose distribution (D1) and the average of the first five repeat scans as our treatment course reference dose distribution (Dref). Patient-specific motion and DIR-uncertainties, at each voxel in CT1, were assessed using a previously developed DIR performance measure, the distance discordance metric (DDM). To sample the distribution of possible true, predicted dose distributions (Dpred), we resampled D1 by perturbing the location of each voxel with the corresponding DDM. The three dose distribution approaches are compared for the rectum and the bladder. Results: The bladder generalized equivalent uniform dose (gEUD) from the averaged Dpred was closer to the gEUDref than to the gEUD1 (difference: 0.6 vs. 1.0 Gy). For both structures, the gEUDpred was higher than the gEUDref, and significantly higher (p≤0.05) for the rectum (average: 50.8 Gy vs. 48.0 Gy). Conclusion: We have shown that the bladder gEUD values resulting from our DIR-uncertainty inclusive dose sampling approach, Dpred, were closer to the gEUD from Dref than the gEUD values from D1. For the rectum, gEUDpred overestimated gEUDref. Theoretically however, gEUDpred values, sampled from DDM uncertainties are more representative of dose uncertainties.

60 APPLIED LIFE SCIENCES↗

Radiation dose rate distributions of spent fuel dry casks estimated with MAVRIC based on detailed geometry and continuous-energy models

This study presents a detailed comparison of the dose rate distributions of a dry TN–32 fuel cask with two geometry models and two cross-sectional datasets. The accuracies of radiation dose rate estimation and computational efficiencies of each geometry model with two cross-sectional data-sets are compared. The use of automated variance reduction techniques can significantly improve the computational efficiency of such a realistic, deep penetration problem that involves radiation transport from different volumetric sources, thereby eliciting only a small statistical error. Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC) is a computational sequence within the SCALE 6.2 code package based on consistent adjoint driven importance sampling (CADIS), a type of automated variance reduction technique. Homogenous and full fuel assembly models are built herein, and two nuclear cross-section libraries (V7–200N47G and continuous energy) are applied in this work. Based on the detailed comparisons, we found that neutron dose rate estimation is more dependent on geometry modeling than on cross-section data. For neutron-induced gamma rays, the dose rate distribution depends on both the spatial self-shielding effect and the cross-section library. The primary gamma rays respectively contribute to the total dose rate by ~91% and ~ 99% on side and top surfaces, and the dose rate accuracy is more dependent on the cross-section library than on geometry modeling. In terms of the computation efficiency and efforts spent on geometry modeling, the homogenous fuel assembly model with the MG library can produce an acceptable dose rate distribution, but the detailed fuel assembly model with the continuous-energy library is required for more precise dose rate estimation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Accurate determination of segmented X-ray detector geometry

Recent advances in X-ray detector technology have resulted in the introduction of segmented detectors composed of many small detector modules tiled together to cover a large detection area. Due to mechanical tolerances and the desire to be able to change the module layout to suit the needs of different experiments, the pixels on each module might not align perfectly on a regular grid. Several detectors are designed to permit detector sub-regions (or modules) to be moved relative to each other for different experiments. Accurate determination of the location of detector elements relative to the beam-sample interaction point is critical for many types of experiment, including X-ray crystallography, coherent diffractive imaging (CDI), small angle X-ray scattering (SAXS) and spectroscopy. For detectors with moveable modules, the relative positions of pixels are no longer fixed, necessitating the development of a simple procedure to calibrate detector geometry after reconfiguration. We describe a simple and robust method for determining the geometry of segmented X-ray detectors using measurements obtained by serial crystallography. By comparing the location of observed Bragg peaks to the spot locations predicted from the crystal indexing procedure, the position, rotation and distance of each module relative to the interaction region can be refined. Furthermore, we show that the refined detector geometry greatly improves the results of experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte-Carlo Simulations of the Nuclear Energy Deposition Inside the CARMEN-1P Differential Calorimeter Irradiated into OSIRIS Reactor

The nuclear heating measurements in Material Testing Reactors (MTRs) are crucial for the study of nuclear materials and fuels under irradiation. The reference measurements of this nuclear heating are especially performed by a differential calorimeter including a graphite sample material. These measurements are then used for other experimental conditions in order to predict the nuclear heating and thermal conditions induced in the irradiation devices. Nuclear heating is a great deal of interest at the moment as the measurement of such heating is an important issue for MTRs reactors. This need is especially generated by the new Jules Horowitz Reactor (JHR), under construction at CEA/Cadarache 'French Alternative Energies and Atomic Energy Commission'. This new reactor, that will be operational in late 2019, is a new facility for the nuclear research on materials and fuels. Indeed the expected nuclear heating rate is about 20 W/g for nominal capacity of 100 MW. The present Monte Carlo calculation works belong to the IN-CORE (Instrumentation for Nuclear radiation and Calorimetry On line in Reactor): a joint research program between the CEA and Aix- Marseille University in 2009. One scientific aim of this program is to design and develop a multi-sensors device, called CARMEN, dedicated to the measurements of main physical parameters simultaneously encountered inside JHR's experimental channels (core and reflector) such as neutron fluxes, photon fluxes, temperature, and nuclear heating. A first prototype was already developed. This prototype includes two mock-ups dedicated respectively to neutronic measurements (CARMEN-1N) and to photonic measurements (CARMEN-1P) with in particular a specific differential calorimeter. Two irradiation campaigns were performed successfully in the periphery of OSIRIS reactor (a MTR located at Saclay, France) in 2012 for nuclear heating levels up to 2 W/g. First Monte Carlo calculations reduced to the graphite sample of the calorimeter were carried out. A preliminary analysis shows that the numerical results overestimate the measurements by about 20 %. A new approach has been developed in order to estimate the nuclear heating by two methods (energy deposition or KERMA) by considering the whole complete geometry of the sensor. This new approach will contribute to the interpretation of the irradiation campaign and will be useful to improve the out-of-pile calibration procedure of the sensor and its thermal response during irradiations. The aim of this paper is to present simulations made by using MCNP5 Monte-Carlo transport code (using ENDF/B-VI nuclear data library) for the nuclear heating inside the different parts of the calorimeter (head, rod and base). Calculations into two steps will be realized. We will use as an input source in the model new spectra (neutrons, prompt-photons and delayed-photons) calculated with the Monte Carlo code TRIPOLI-4{sup R} inside different experimental channels (water) located into the OSIRIS periphery and used during the CARMEN-1P irradiation campaign. We will consider Neutrons- Photons-Electrons and Photons-Electrons modes. We will begin by a brief description of the differential-calorimeter device geometry. Then the MCNP5 model used for the calculations of nuclear heating inside the calorimeter elements will be introduced. The energy deposition due to the prompt-gamma, delayed-gamma and neutrons, the neutron-activation of the device will be considered. The different components of the nuclear heating inside the different parts of the calorimeter will be detailed. Moreover, a comparison between KERMA and nuclear energy deposition estimations will be given. Finally, a comparison between this total nuclear heating Calculation and Experiment in graphite sample will be determined. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of Stress Ratio on the Fatigue Behavior of a Friction Stir Processed Cast Al-Si-Mg Alloy

The effect of friction stir processing (FSP) on the fatigue life of a cast Al-7Si-0.6Mg alloy at a stress ratio of R=0 was evaluated. Two types of specimen geometry were used for the FSPed condition, through-thickness processed and partial thickness processed. FSP enhanced the fatigue life by a factor of 15 for the through thickness processed samples at lower stress amplitudes. This is different from the FSP specimens tested at R=-1 and similar stress amplitudes where a 5 times improvement in fatigue life was observed. In light of these observations, various closure mechanisms were examined.

36 MATERIALS SCIENCE↗

Noncollinear ferromagnetic easy axes in Py/Ru/FeCo/IrMn spin valves induced by oblique deposition

We present an investigation on the magnetic properties of Py/Ru/FeCo/IrMn spin valves grown by dc magnetron sputtering. The sample fabrication setup has two important features, (i) the five magnetron sputtering sources are placed in a cluster flange 72° from each other, and (ii) each source is tilted with respect to the sample normal. In-plane angular dependence of the ferromagnetic resonance (FMR) was used to obtain the relevant magnetic anisotropies, such as uniaxial and exchange bias fields. The oblique deposition geometry employed has induced non-collinear easy axes of the two ferromagnetic (FM) layers, with high uniaxial field strengths. The symmetry shift of the angular dependence of the FMR resonances of the two FM layers gives us directly the angle between the easy axes of FM{sub 1} (Py) and FM{sub 2} (FeCo), which turned out to be the angle between two adjacent sputtering sources. The observations of the present study suggest that, by combining oblique deposition and appropriate angles of incidence of the deposition flux, the uniaxial (and unidirectional) axes of individual FM layers can be precisely engineered in spin valve fabrication.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The ultraviolet attenuation law in backlit spiral galaxies

The effective extinction law (attenuation behavior) in galaxies in the emitted ultraviolet (UV) regime is well known only for actively star-forming objects and combines effects of the grain properties, fine structure in the dust distribution, and relative distributions of stars and dust. We use Galaxy Evolution Explorer, XMM Optical Monitor, and Hubble Space Telescope (HST) data to explore the UV attenuation in the outer parts of spiral disks which are backlit by other UV-bright galaxies, starting with the candidate list of pairs provided by Galaxy Zoo participants. New optical images help to constrain the geometry and structure of the target galaxies. Our analysis incorporates galaxy symmetry, using non-overlapping regions of each galaxy to derive error estimates on the attenuation measurements. The entire sample has an attenuation law across the optical and UV that is close to the Calzetti et al. form; the UV slope for the overall sample is substantially shallower than found by Wild et al., which is a reasonable match to the more distant galaxies in our sample but not to the weighted combination including NGC 2207. The nearby, bright spiral NGC 2207 alone gives an accuracy almost equal to the rest of our sample, and its outer arms have a very low level of foreground starlight. Thus, this widespread, fairly 'gray' law can be produced from the distribution of dust alone, without a necessary contribution from differential escape of stars from dense clouds. Our results indicate that the extrapolation needed to compare attenuation between backlit galaxies at moderate redshifts from HST data, and local systems from Sloan Digital Sky Survey and similar data, is mild enough to allow the use of galaxy overlaps to trace the cosmic history of dust in galaxies. For NGC 2207, HST data in the near-UV F336W band show that the covering factor of clouds with small optical attenuation becomes a dominant factor farther into the UV, which opens the possibility that widespread diffuse dust dominates over dust in star-forming regions deep into the UV. Comparison with published radiative-transfer models indicates that the role of dust clumping dominates over differences in grain populations at this coarse spatial resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Fast Decay-Energy Spectroscopy With Magnetic Microcalorimeters

Decay energy spectroscopy (DES) is an increasingly important radiometric technique arising from the unique thermal detection physics and the precision of low-temperature microcalorimetry. DES can enable high-precision analysis of very small amounts of radioactive material with simple and rapid sample preparation, making it a key new tool for nuclear safeguards, nuclear forensics, the improvement of nuclear data, measurements of absolute activity, and other applications. For problems in nuclear safeguards and nuclear forensics it is highly desirable to increase the count rates achievable in DES, while maintaining simple and rapid sample preparation. Here, in this report, we describe progress in a new project to achieve high count rates in DES by taking advantage of the physics of magnetic microcalorimetry. We describe the results of initial modeling and experiment to validate the idea, a sample fabrication technique suitable for nuclear materials laboratories, the preparation and initial tests of paramagnetic Au-Er alloy in thin foil form, and the development of a sensing coil geometry that will perform well with the increased-thickness sensor used in the new technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Accelerating Monte Carlo simulations of photon transport in a voxelized geometry using a massively parallel graphics processing unit

Purpose: It is a known fact that Monte Carlo simulations of radiation transport are computationally intensive and may require long computing times. The authors introduce a new paradigm for the acceleration of Monte Carlo simulations: The use of a graphics processing unit (GPU) as the main computing device instead of a central processing unit (CPU). Methods: A GPU-based Monte Carlo code that simulates photon transport in a voxelized geometry with the accurate physics models from PENELOPE has been developed using the CUDA programming model (NVIDIA Corporation, Santa Clara, CA). Results: An outline of the new code and a sample x-ray imaging simulation with an anthropomorphic phantom are presented. A remarkable 27-fold speed up factor was obtained using a GPU compared to a single core CPU. Conclusions: The reported results show that GPUs are currently a good alternative to CPUs for the simulation of radiation transport. Since the performance of GPUs is currently increasing at a faster pace than that of CPUs, the advantages of GPU-based software are likely to be more pronounced in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Letter to the editor: Cone partitioned plate (CPP) vs circular couette

In geometries capable of producing uniform shear stress across the gap such as cone plate, it is a challenge to study the nonlinear rheology of well-entangled polymers without wall slip and edge fracture. The task to obtain meaningful steady-state information is particularly daunting. Significant insights are required in the design of experiments and choice of reliable apparatuses that could fulfill the objective to determine the constitutive behavior. In a recent published article, Hu J. Rheol. 54, 1307 1323 (2010) reported particle-imaging velocimetric measurements of two highly entangled polybutadiene solutions with a cocylinder geometry. One of the solutions was prepared and provided to Hu by Ravindranath from the University of Akron. Rheological and particletracking velocimetric studies have been carried out on the same sample in our laboratory. In this letter, we will compare Hu s results with our own measurements, clarify a few misrepresentations, and discuss several important issues concerning shear banding in entangled polymers.

Ravindranath, Sham↗

A characteristic transmission spectrum dominated by H{sub 2}O applies to the majority of HST/WFC3 exoplanet observations

Currently, 19 transiting exoplanets have published transmission spectra obtained with the Hubble/WFC3 G141 near-IR grism. Using this sample, we have undertaken a uniform analysis incorporating measurement-error debiasing of the spectral modulation due to H{sub 2}O, measured in terms of the estimated atmospheric scale height, H{sub s}. For those planets with a reported H{sub 2}O detection (10 out of 19), the spectral modulation due to H{sub 2}O ranges from 0.9 to 2.9 H{sub s} with a mean value of 1.8 ± 0.5 H{sub s}. This spectral modulation is significantly less than predicted for clear atmospheres. For the group of planets in which H{sub 2}O has been detected, we find the individual spectra can be coherently averaged to produce a characteristic spectrum in which the shape, together with the spectral modulation of the sample, are consistent with a range of H{sub 2}O mixing ratios and cloud-top pressures, with a minimum H{sub 2}O mixing ratio of 17{sub −6}{sup +12} ppm corresponding to the cloud-free case. Using this lower limit, we show that clouds or aerosols must block at least half of the atmospheric column that would otherwise be sampled by transmission spectroscopy in the case of a cloud-free atmosphere. We conclude that terminator-region clouds with sufficient opacity to be opaque in slant-viewing geometry are common in hot Jupiters.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of an in-situ corrosion monitor for molten salt reactors

A novel in-situ corrosion sensor for structural alloys exposed to molten salts has been initially demonstrated. The measurement is based upon observing the change in magnetic susceptibility of salt wetted structural alloys as corrosion occurs. In halide salts corrosion of structural alloys proceeds primarily through dissolution of the least noble component of the alloy into the melt. All currently available structural alloys intended for use with molten salt reactors (MSRs) include nickel, chromium, and iron. Chromium is preferentially oxidized from the alloy surface by exposure to halide salts at high temperature. Diffusion within the alloy results in progressively deeper depletion of chromium from the alloy surface. Relevant chromium bearing structural alloys are paramagnetic. However, once the chromium has been depleted, they become ferromagnetic. Thus, structural alloy corrosion in an MSR results in development of a ferromagnetic surface layer whose depth increases with increasing corrosion. The corrosion sensor functions by employing the progressive increase in ferromagnetism as a transduction mechanism through including the corroding alloy in a magnetic circuit. Development of the sensor remains a work in progress. To date we have characterized the sensor response of structural alloy samples with varying degrees of corrosion at room temperature. Over the next year we plan to demonstrate sensor performance at MSR operating temperatures (up to 750 °C) in a piping geometry.

Holcomb, David↗

A perforated diamond anvil cell for high-energy x-ray diffraction of liquids and amorphous solids at high pressure

Diamond anvil cells (DACs) are widely used for the study of materials at high pressure. The typical diamonds used are between 1 and 3 mm thick, while the sample contained within the opposing diamonds is often just a few microns in thickness. Hence, any absorbance or scattering from diamond can cause a significant background or interference when probing a sample in a DAC. By perforating the diamond to within 50-100 {micro}m of the sample, the amount of diamond and the resulting background or interference can be dramatically reduced. The DAC presented in this article is designed to study amorphous materials at high pressure using high-energy x-ray scattering (>60 keV) using laser-perforated diamonds. A small diameter perforation maintains structural integrity and has allowed us to reach pressures >50 GPa, while dramatically decreasing the intensity of the x-ray diffraction background (primarily Compton scattering) when compared to studies using solid diamonds. This cell design allows us for the first time measurement of x-ray scattering from light (low Z) amorphous materials. Here, we present data for two examples using the described DAC with one and two perforated diamond geometries for the high-pressure structural studies of SiO{sub 2} glass and B{sub 2}O{sub 3} glass.

36 MATERIALS SCIENCE↗