Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Effect of advanced nanowire-based targets in nanosecond laser-matter interaction (invited)

An experimental campaign aiming to investigate the effects of innovative nanostructured targets based on Ag nanowires on laser energy absorption in the ns time domain has been carried out at the Laser Energy for Nuclear Science laboratory of INFN-LNS in Catania. The tested targets were realized at INFN-Bologna by anodizing aluminium sheets in order to obtain layers of porous Al{sub 2}O{sub 3} of different thicknesses, on which nanowires of various metals are grown by electro-deposition with different heights. Targets were then irradiated by using a Nd:YAG laser at different pumping energies. Advanced diagnostic tools were used for characterizing the plasma plume and ion production. As compared with targets of pure Al, a huge enhancement (of almost two order of magnitude) of the X-ray flux emitted by the plasma has been observed when using the nanostructured targets, with a corresponding decrease of the “optical range” signal, pointing out that the energetic content of the laser produced plasma was remarkably increased. This analysis was furthermore confirmed from time-of-flight spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trial of a proposed protocol for constancy control of digital mammography systems

Purpose: Evaluate the utility of tests in a proposed protocol for constancy control of digital mammography systems. Methods: The protocol contained tests for image acquisition, mechanical function and safety, monitors and printers, and viewing conditions. Nine sites with digital systems from four equipment manufacturers were recruited. Dedicated PMMA test objects and Excel spreadsheets were developed. Quantitative measurements were done on processed images for systems where these images were the ones most readily available. For daily assessment of the automatic exposure control system, a homogeneous PMMA phantom was exposed under clinical conditions. The mAs and signal to noise ratio (SNR) were recorded, the deviation from a target value calculated, and the resulting image inspected for artifacts. For thickness tracking, the signal difference to noise ratio obtained for three thicknesses was calculated. Detector uniformity was assessed through comparison of SNR values for regions of interest in the center and corners of an image of a homogeneous test object. Mechanical function and safety control included a compression test, a checklist for mechanical aspects, and control of field alignment. Monitor performance was evaluated by visual inspection of the AAPM TG 18 QC test image [E. Samei et al., ''Assessment of display performance for medical imaging systems,'' Task Group 18 (Madison, WI, April 2005)]. Results: For quantitative parameters, target values and tolerance limits were established. Test results exceeding the limits were registered. Most systems exhibited stable mAs values, indicating that the tolerance limit of {+-}10% was readily achievable. The SNR also showed little variation, indicating that the tolerance limit of {+-}20% was too wide. At one site, a defective grid caused artifacts that were visible in the test images. The monitor controls proved more difficult to implement due to both difficulties importing and displaying the test image, and the radiographic technologists not getting necessary access to the reading stations. Conclusions: The proposed tests could easily be performed by trained radiographic technologists and within a time frame comparable to similar programs for analog systems. Tests with quantitative measures were more readily performed than procedures that required a subjective evaluation. Several of the proposed tests revealed equipment performance that required intervention, and which would otherwise have gone unnoticed. They therefore defend a place in a vendor-independent constancy control protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The EURISOL Multi-MW Target Unit: Neutronics, Dose Rate, Shielding and Activation Calculations

The EURISOL (The EURopean Isotope Separation On-Line Radioactive Ion Beam) project aims at designing a facility for producing high intensity radioactive ion beams, with unprecedented (two to three orders of magnitude higher) intensities, compared to the majority of the worldwide existing RIB facilities. For this purpose, a proton beam of energy 1 GeV and intensity up to 4 mA impinges on a liquid mercury target (the converter). The high neutron fluxes (in excess of 10{sup 15} n cm{sup -2} s{sup -1}) produced by spallation nuclear reactions in the converter induce fission on {sup 235}U targets surrounding the liquid mercury converter. In order to attain the intended high intensity radioactive ion beams, the appropriate configuration (geometry and materials) of the target unit components (converter, fission targets, moderators, reflectors) must be determined, to attain the highest possible fission rates in the uranium targets (in excess of 10{sup 15} fissions per second). The extremely high neutron and photon fluxes resulting from the operation of the target unit impose, for radiological protection and safety purposes, a careful assessment of the dose rates in the surrounding areas. Activation of the structural components must be studied. Thick shielding barriers must be designed. In this work, the so-called MAFF inspired target configuration, allowing a versatile operation, maintenance, remote control and storage of the fission targets is considered. The results obtained using the state-of-the-art Monte Carlo codes MCNPX and FLUKA are presented. The neutronics, dose rate, shielding and activation calculations, needed for radiological protection and safety assessment purposes are discussed.

43 PARTICLE ACCELERATORS↗

Film thickness measurement techniques applied to micro-scale two-phase flow systems

Recently semi-empirical models to estimate flow boiling heat transfer coefficient, saturated CHF and pressure drop in micro-scale channels have been proposed. Most of the models were developed based on elongated bubbles and annular flows in the view of the fact that these flow patterns are predominant in smaller channels. In these models, the liquid film thickness plays an important role and such a fact emphasizes that the accurate measurement of the liquid film thickness is a key point to validate them. On the other hand, several techniques have been successfully applied to measure liquid film thicknesses during condensation and evaporation under macro-scale conditions. However, although this subject has been targeted by several leading laboratories around the world, it seems that there is no conclusive result describing a successful technique capable of measuring dynamic liquid film thickness during evaporation inside micro-scale round channels. This work presents a comprehensive literature review of the methods used to measure liquid film thickness in macro- and micro-scale systems. The methods are described and the main difficulties related to their use in micro-scale systems are identified. Based on this discussion, the most promising methods to measure dynamic liquid film thickness in micro-scale channels are identified. (author)

42 ENGINEERING↗

The Metallicity Distribution Functions of SEGUE G and K dwarfs: Constraints for Disk Chemical Evolution and Formation

Using the G and K dwarfs from the Sloan Extension for Galactic Understanding and Exploration (SEGUE) survey, we determine the metallicity distributions of cool stars in the Milky Way disk system. This portion of the Sloan Digital Sky Survey (SDSS) contains spectra for approximately 41,500 G and 23,800 K dwarfs, a significantly larger sample, both numerically and spatially, than previous spectroscopic analyses. Comparison of these two spectral types, and their variation in metallicity with respect to Galactic position, provides important guidance for models of the formation and chemical evolution of the Milky Way's thick-disk component. SEGUE has a well-defined, quantitative target-selection algorithm, based on ugriz photometry and proper motions; this allows us to adjust our spectroscopic sample such that it accurately represents the underlying Milky Way populations.Combining atmospheric parameters, determined by an optimized version of the SEGUE Stellar Parameter Pipeline, with various isochrones, we calculate the distance to each star, accurate to {approx}12%. We then quantify the variation in metallicity with respect to spatial position from the Galactic center (R) and the plane of the Galaxy (|Z|). Our unbiased observations of G and K dwarfs provide valuable constraints for chemical and dynamical Galaxy evolution models, with particular utility for thin- and thick-disk formation theory. Although our uncertainties in the radial metallicity gradient are large, we are consistent with the results from Cheng et al., estimating a negative gradient below |Z| of 1 kpc that flattens above this height. Both spectral types also exhibit a consistent decrease in [Fe/H] with increasing |Z|, approximately -0.3 dex/kpc. Comparison with the sample of Lee et al., which distinguishes between the thin and thick disk using [{alpha}/Fe], suggests that this gradient reflects the transition in G and K dwarfs from a thin-disk dominated sample at small |Z| to a sample consisting primarily of thick-disk stars above |Z| of 1 kpc. We compare our distributions to those of two different models of the Galaxy: the population synthesis model TRILEGAL (Girardi et al. 2004) and that of Schoenrich & Binney which simulates chemical and dynamical evolution. Both models show little change in [Fe/H] with respect to |Z| and are unable to replicate the metallicity distributions we observe above |Z| of 0.5 kpc. This result is not surprising, as the existing chemical constraints on Galaxy models are limited to the solar neighborhood, which is thin-disk dominated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser deposition of large-area thin films

A new method for fabricating large-area thin films of uniform thickness on a rotating substrate is proposed. Its distinctive features are (i) the presence of a diaphragm, partially transmitting the evaporated material, between the target and substrate and (ii) the translatory motion of the rotating substrate with respect to the target at a certain velocity. The method proposed makes it possible to obtain thin films of uniform thickness on substrates with sizes limited by only the deposition chamber size. The method is experimentally verified by depositing thin CuO films on silicon substrates placed over the radius of a disk 300 mm in diameter. The deviation of the film thickness from the average value does not exceed {+-}3% throughout the entire radius, which confirms good prospects of this method for microelectronics, optical industry, and other modern technologies. (laser technology)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of sub-picosecond laser-produced fast electrons by modeling angularly resolved bremsstrahlung measurements with 3D hybrid particle-in-cell code

Hard x-rays produced by intense laser-produced fast electrons interacting with solids are a vital source for producing radiographs of high-density objects and implosion cores for inertial confinement fusion. Accurate calculation of hard x-ray sources requires a three-dimensional (3D) simulation geometry that fully models the electron transport dynamics, including electron recirculation and the generation of absolute photon yields. To date, 3D simulations of laser-produced bremsstrahlung photons over tens of picoseconds and code benchmarking have not been performed definitively. In this study, we characterize sub-picosecond laser-produced fast electrons by modeling angularly resolved bremsstrahlung measurements for refluxing and non-refluxing targets using the 3D hybrid particle-in-cell (PIC), Large Scale Plasma code. Bremsstrahlung radiation and escaped electron data were obtained by focusing a 50-TW Leopard laser (15 J, 0.35 ps, 2 × 10 19 W/cm 2 ) on a 100-μm-thick Cu foil and a Cu with a large plastic backing (Cu–CH target). Data for both the Cu and Cu–CH targets were reproduced for simulations with a given set of electron parameters. Comparison of the simulations revealed that the hard x-ray emission from the Cu target was significantly longer in duration than that from the Cu–CH target. Here, the benchmarked hybrid PIC code could prove to be a powerful tool in the design and optimization of time- and angular-dependent bremsstrahlung sources for flash x-ray and gamma-ray radiography.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extreme ultraviolet source at 6.7 nm based on a low-density plasma

We demonstrate an efficient extreme ultraviolet (EUV) source for operation at {lambda} = 6.7 nm by optimizing the optical thickness of gadolinium (Gd) plasmas. Using low initial density Gd targets and dual laser pulse irradiation, we observed a maximum EUV conversion efficiency (CE) of 0.54% for 0.6% bandwidth (BW) (1.8% for 2% BW), which is 1.6 times larger than the 0.33% (0.6% BW) CE produced from a solid density target. Enhancement of the EUV CE by use of a low-density plasma is attributed to the reduction of self-absorption effects.

07 ISOTOPE AND RADIATION SOURCES↗

Proton Distribution Radii of 16–24 O: Signatures of New Shell Closures and Neutron Skin

The root mean square radii of the proton density distribution in 16–24 O derived from measurements of charge changing cross sections with a carbon target at ~900A MeV together with the matter radii portray thick neutron skin for 22–24 O despite 22,24 O being doubly magic. Imprints of the shell closures at N=14 and 16 are reflected in local minima of their proton radii that provide evidence for the tensor interaction causing them. The radii agree with ab initio calculations employing the chiral NNLO sat interaction, though skin thickness predictions are challenged. Furthermore, shell model predictions agree well with the data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Properties of thin N-type Yb{sub 0.14}Co{sub 4}Sb{sub 12} and P-type Ce{sub 0.09}Fe{sub 0.67}Co{sub 3.33}Sb{sub 12} skutterudite layers prepared by laser ablation

The properties of thin thermoelectric layers (about 60 nm in thickness) prepared by pulsed laser deposition are presented. Hot pressed targets were made from ''middle'' temperature range thermoelectric bulk materials with the potential high figure of merit ZT. P-type and N-type layers were prepared from Yb{sub 0.19}Co{sub 4}Sb{sub 12} and Ce{sub 0.1}Fe{sub 0.7}Co{sub 3.3}Sb{sub 12} targets, respectively. The thin films were deposited on quartz glass substrates using KrF excimer laser. The individual layers were prepared by applying different laser beam energy densities (2 or 3 J cm{sup -2}) at several substrate temperatures (200, 250, or 300 deg. C). Crystallinity and composition of the layers were examined by x-ray diffraction and wavelength dispersive analysis, respectively. Homogeneity of Yb across a surface of the Yb filled film was explored by secondary ion mass spectrometry. The thermoelectric properties, the Seebeck coefficient, the electrical resistivity, and the power factor, for the best prepared P and N layer are presented in the temperature range from 300 to 500 K.

36 MATERIALS SCIENCE↗

SU-F-T-671: Effects of Collimator Material On Proton Minibeams

Purpose: To investigate the dosimetric effects of collimator material on spatially modulated proton minibeams (pMBRT). Methods: pMBRT holds promise to exhibit shallow depth normal-tissue sparing effects similar to synchrotron based microbeams while also retaining potential for uniform dose distributions for tumor targets. TOPAS Monte Carlo simulations were performed for a 5cm thick multislit collimator with 0.3mm slits and 1mm center-to-center spacing for a 50.5MeV proton minibeam while varying collimator material between brass, tungsten, and iron. The collimator was placed both “flush” at the water phantom surface and at 5cm distance to investigate the effects on surface dose, peak-to-valley-dose-ratio (PVDR) and neutron contribution. Results: For flush placement, the neutron dose at the phantom surface for the tungsten collimator was approximately 20% higher than for brass and iron. This was not reflected in the overall surface dose, which was comparable for all materials due to the relatively low neutron contribution of <0.1%. When the collimator was retracted, the overall neutron contribution was essentially identical for all three collimators. Surface dose dropped by ∼40% for all collimator materials with air gap compared to being flush with the phantom surface. This surface dose reduction was at the cost of increase in valley dose for all collimator materials due to increased angular divergence of the mini-beams at the surface and their consequent geometric penumbra at depth. When the collimator was placed at distance from the phantom surface the PVDR decreased. The peak-to-entrance-dose ratio was highest for the iron collimator with 5cm air gap. Conclusion: The dosimetric difference between the collimator materials is minimal despite the relatively higher neutron contribution at the phantom surface for the tungsten collimator when placed flush. The air gap between the collimator and phantom surface strongly influences all dosimetry parameters due to the influence of scatter on the narrow spatial modulation.

60 APPLIED LIFE SCIENCES↗

A universal metasurface transfer technique for heterogeneous integration

Metasurfaces offer a versatile platform for engineering the wavefront of light using nanostructures with subwavelength dimensions and hold great promise for dramatically miniaturizing conventional optical elements due to their small footprint and broad functionality. However, metasurfaces so far have been mainly demonstrated on bulky and planar substrates that are often orders of magnitude thicker than the metasurface itself. Conventional substrates not only nullify the reduced footprint advantage of metasurfaces, but also limit their application scenarios. The bulk substrate also determines the metasurface dielectric environment, with potentially undesired optical effects that undermine the optical performance. Here we develop a universal polymer-assisted transfer technique to tackle this challenge by decoupling the substrate employed on the fabrication of metasurfaces from that used for the target application. As an example, Huygens’ metasurfaces with 120 nm thickness in the visible range (532 nm) are demonstrated to be transferred onto a 100 nm thick freestanding SiN x membrane while maintaining excellent structural integrity and optical performance of diffraction-limited focusing. This transfer method not only enables the thinnest dielectric metalens to the best of our knowledge, but also opens up new opportunities in integrating cascaded and multilayer metasurfaces, as well as the heterogeneous integration with nonconventional substrates and various electronic/photonic devices.

42 ENGINEERING↗

T-1075: Large Area Fast Timing Beam Time of Flight (LAFTBToF) for ProtoDUNE

Large-area Picosecond Photodetectors (LAPPDs), developed at Argonne National Laboratory (ANL), present an opportunity to provide identification of charged particles in the 2-10 GeV/c range. Traditional methods using ionization or Cherenkov detectors require large amounts of material or pathlength for the particle to traverse in order to get a clean measurement, and are ill suited for particle beam identification in fixed-target experiments. The 6x6 cm 2 LAPPD uses mm-thick borosilicate glass micro-channel plates with a resistive surface coating added via atomic layer deposition. An electrical connection schematic of the LAPPD is shown in Figure 1. Electrons emitted by the photocathode are accelerated through the MCPs, which have µm-sized capillaries, and an avalanche of electrons is created as the electrons collide against the walls of the capillaries of the MCPs. The resulting electron avalanche is collected on anode strip lines and the signal may be read out on both ends of the stipline. The resistive coating of the thin MCPs and the short path length of the electrons to the readout results in fast rise times, gains of greater than 10 6 and typical timing resolutions of 50 ps. Differential timing on the ends of the strip lines can provide mm-level position measurements. The material of the bare LAPPD presents less than 0.05 of an interaction length and approximately 0.12 of a radiation length for a charged particle of I GeV/c. In our application, two large-area photodetectors separated by 5-10 meters can be used in a time-of-flight (ToF) measurement for 3σ separation of2-7 GeV/c charged pions, kaons and protons with minimal impact on the particle's trajectory and momentum.

43 PARTICLE ACCELERATORS↗

Airborne CO2 coherent lidar measurements of cloud backscatter and opacity over the ocean surface

The use of an airborne CO2 lidar to obtain cloud backscatter and extinction data at a thermal infrared wavelength is described. The extinction in this spectral region is proportional to the cloud liquid water content. The use of coherent detection results in high sensitivity and narrow field of view, the latter property greatly reducing multiple-scattering effects. Backscatter measurements in absolute units are obtained through a hard target calibration methodology. For clouds of low to moderate optical thickness at the lidar wavelength, both geometric thickness and optical thickness can be measured. The sea surface reflectance signal is used to obtain estimates of the cloud optical thickness. The utility of this technique results from studies that indicate that the spatial scale of variability of the sea surface reflectance is generally large compared with that of cloud optical thickness. Selected results are presented from data taken during flights over the Pacific Ocean.

Menzies, Robert T.↗

ATIC Experiment: Elemental Spectra from the Flight in 2000

The Advanced Thin Ionization Calorimeter (ATIC) had successful Long Duration Balloon flights from McMurdo, Antarctica in both 2000 and 2002. The instrument consists of a silicon matrix charge detector, a 0.75 nuclear interaction length graphite target, 3 scintillator strip hodoscopes, and an 18 radiation length thick BGO calorimeter to measure the cosmic ray composition and energy spectra from approximately 30 GeV to near 100 TeV. In this paper, we present preliminary results from the first flight, which was a test flight that lasted for 16 days, starting on 12/28/00.

Ahn, H. S.↗

A Residual Mass Ballistic Testing Method to Compare Armor Materials or Components (Residual Mass Ballistic Testing Method)

A statistics based ballistic test method is presented for use when comparing multiple groups of test articles of unknown relative ballistic perforation resistance. The method is intended to be more efficient than many traditional methods for research and development testing. To establish the validity of the method, it is employed in this study to compare test groups of known relative ballistic performance. Multiple groups of test articles were perforated using consistent projectiles and impact conditions. Test groups were made of rolled homogeneous armor (RHA) plates and differed in thickness. After perforation, each residual projectile was captured behind the target and its mass was measured. The residual masses measured for each test group were analyzed to provide ballistic performance rankings with associated confidence levels. When compared to traditional V50 methods, the residual mass (RM) method was found to require fewer test events and be more tolerant of variations in impact conditions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The role of hot electron refluxing in laser-generated K-alpha sources

A study of the contribution of refluxing electrons in the production of K-alpha radiation from high-intensity laser irradiated thin targets has been performed. Thin copper foils both freestanding, and backed by a thick substrate were irradiated with laser pulses of energies around 100 J at intensities ranging from below 10{sup 17} to above 10{sup 19} W/cm{sup 2}. At high laser intensities we find a strong reduction in the K-alpha yield from targets backed by the substrate. The observed yield reduction is in good agreement with a simple model using hot electron spectra from particle-in-cell simulations or directly inferred from the measured bremsstrahlung emission and can therefore be interpreted as due to the suppression of hot electron refluxing. The study shows that refluxing electrons play a dominant role in high-intensity laser driven K- alpha generation and have to be taken into account in designing targets for laser driven high-flux K-alpha sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DAMIC at SNOLAB

We introduce the fully-depleted charge-coupled device (CCD) as a particle detector. We demonstrate its low energy threshold operation, capable of detecting ionizing energy depositions in a single pixel down to 50 eV ee . We present results of energy calibrations from 0.3 keV ee to 60 ke Vee , showing that the CCD is a fully active detector with uniform energy response throughout the silicon target, good resolution (Fano ~0.16), and remarkable linear response to electron energy depositions. We show the capability of the CCD to localize the depth of particle interactions within the silicon target. We discuss the mode of operation and unique imaging capabilities of the CCD, and how they may be exploited to characterize and suppress backgrounds. We present the first results from the deployment of 250 μm thick CCDs in SNOLAB, a prototype for the upcoming DAMIC100. DAMIC100 will have a target mass of 0.1 kg and should be able to directly test the CDMS-Si signal within a year of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗