Search NASA⌕ Search

SEARCH · Search NASA

Results for “acceptance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Challenges in spatial metabolomics and proteomics for functional tissue unit and single-cell resolution

While transcriptomics is the most broadly applied technology for global spatial and single cell measurements in healthy and diseased tissues. Transcripts are often used as a proxy for protein and even metabolite measurements, but it has become commonly accepted that extrapolating this kind of information is a poor proxy and not a substitute for direct measurement. Within the last decade advanced developments of mass spectrometry-based assays have made these direct measurements not only possible, but routine. Where mass spectrometry has become an enabling technology, and various methods can now detect hundreds of metabolites and thousands of proteins from samples. Not only can this be performed within bulk measurements, but much effort has been directed into translating these measurements to single cells and tissues at cellular resolution. The information obtained from mass spectrometry is now able to trace metabolic events and decipher feedback loops across anatomical regions, connecting genetic and metabolic networks that define phenotypes. Herein, we will broadly overview developments in the field over the past decade, leading into several case studies which highlight the direct measurement of metabolites, proteins, and proteoforms from thinly sliced tissues. Much of this work is feasible due to multidisciplinary team science, and we offer brief perspective on paths forward and the challenges that persist with adoption and application of spatial omics.

59 BASIC BIOLOGICAL SCIENCES↗

Fabrication of Sr silicate buffer layer on Si(100) substrate by pulsed laser deposition using a SrO target

The authors fabricated 2 × 1 Sr-reconstructed Si(100) substrates using thin SrO layers, and used them to direct growth of crystalline perovskite oxide on Si. The SrO layers used to reconstruct the Si(100) substrates were grown by pulsed laser deposition from a SrO single crystal target, followed by postdeposition-annealing (PDA) of the SrO/Si(100) structure. In situ observations of reflective high-energy electron diffraction during PDA confirmed a 2 × 1 reconstruction of the Si surface and x-ray photoemission spectroscopy of the annealed samples confirmed the existence of Sr atoms in a silicate phase, which indicated that a 2 × 1 Sr-reconstructed Si surface was achieved. The optimal fabrication conditions were annealing at 720 °C for 1 min and an equivalent SrO layer thickness (ML{sub eq}) of 2.5 ML{sub eq}. The temperature condition was very narrow, at 720 ± 20 °C, for an acceptable product. Subsequently, the authors demonstrated the growth of crystalline SrTiO{sub 3} films on the 2 × 1 Sr-reconstructed Si(100) surfaces.

36 MATERIALS SCIENCE↗

Data and Scripts associated with: “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy”

This data package is associated with the publication “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?” submitted to PLOS ONE and accepted for publication (Fulton, S.G. et al. 2023; doi not yet available).Variation in electrical conductivity (EC) of water is important to reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. This data package supports a study addressing the need for a robust performance assessment of open source (OS) EC sensors. We evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. This data package presents the results from the different testing laboratory configurations. It also includes an R script for statistical analysis of the data and an Arduino IDE file used to calibrate and collect data with the OS Atlas EC sensor. File types are .csv, .pdf, .R, and .ino.

54 ENVIRONMENTAL SCIENCES↗

Extraction, scrub, and strip test results for the salt waste processing facility caustic side solvent extraction solvent example

An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 12.9, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction, Scrub, and Strip Test Results for the Salt Waste Processing Facility Caustic Side Solvent Extraction Solvent Sample

An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D( Cs )), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D( Cs ) measured 12.5, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges. This revision was created to correct an error. The previous revision used an incorrect set of temperature correction coefficients which resulted in slight deviations from the correct D( Cs ) results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction, Scrub, and Strip Test Results for the Salt Waste Processing Facility Caustic Side Solvent Extraction Solvent Sample

An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D (Cs) ), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D (Cs) measured 13.2, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Zinc Nucleation and Growth in Microgravity

We report our experiences with zinc nucleation in a microgravity environment aboard NASA's Reduced Gravity Research Facility. Zinc vapor is produced by a heater in a vacuum chamber containing argon gas. Nucleation is induced by cooling and its onset is easily detected visually by the appearance of a cloud of solid, at least partially crystalline zinc particles. Size distribution of these particles is monitored in situ by photon correlation spectroscopy. Samples of particles are also extracted for later analysis by SEM. The initially rapid increase in particle size is followed by a slower period of growth. We apply Scaled Nucleation Theory to our data and find that the derived critical temperature of zinc, the critical cluster size at nucleation, and the surface tension values are all in reasonably good agreement with their accepted literature values.

Michael, B. Patrick↗

Particle Filter Based Inference Testing

The primary intent of PAR-FIT (Particle Filter based Inference Testing) is to provide hard inductive evidence that a machine learning model is capable and proven for an individual test input. By examining training data used to form the underlying model functional correlation, an estimate of the reliability that a model will make the correct prediction can be made. The Sequential Probability Ratio Test is used to derive a qualitative evaluation for reliability based on hypothesis testing. The PAR-FIT framework achieves this by implementing a particle filter and the sequential probability ratio test algorithms on the machine learning model training data to determine relevancy of new individual test samples to the training dataset. The kernel function evaluates the local proximity and density of training data used to derive a prediction outcome. Particles are used to probabilistically determine which training data to evaluate for proximity. For test samples that are within a close proximity to and surrounded by multiple training data points, the evaluated reliability of the prediction is high. For test samples that are anomalies not represented by the training dataset, in low density data clusters, or are far from existing data points, the evaluated reliability is low as insufficient training evidence exists to suggest the model is capable of making the correct prediction. Sequential Probability Ratio Test is further used to determine when a hypothesis on whether a signal can be rejected or accepted for use. The ratio test collects sequence information from the particle filter to test whether the signal is anomalous or normal via hypothesis testing of the underlying distributions.

Chen, Edward [Idaho National Laboratory (INL), Ida↗

VADER: A Tool for Criticality Safety Validation

The purpose of criticality safety is to prevent any inadvertent criticality from occurring during the handling or storage of fissile material. Calculations are frequently used to demonstrate that a sufficient subcritical margin exists. Validation is a key aspect of the evaluation process, establishing the suitability, accuracy, and associated uncertainty of the computational method and data to be used for the intended application. The validation process is performed by comparing the results of critical experiments with the calculated results from models of the experiments using the computational method to be validated. Laboratory critical experiments are controlled systems that achieve a k eff of approximately 1 in order to investigate the parameters at which such a critical condition is achieved. The validation parameters that are traditionally applied to safety analysis calculations are the bias and the bias uncertainty . The bias is the deviation of the average k eff of the validation suite from unity. The bias uncertainty accounts for the statistical uncertainty in the bias based on the standard deviation, sample size, and distribution of k eff values of the validation suite. The values of bias and bias uncertainty ensure that the systems predicted to be subcritical by the computational method will indeed be subcritical. The bias and bias uncertainty are often combined to determine an upper subcritical limit (USL) or computational margin that can then be applied to safety analysis calculations. Many methods have been developed by different organizations to calculate the bias and bias uncertainty for various types of criticality analyses. Each of these methods typically requires that the validity of various underpinning statistical assumptions be confirmed to demonstrate that the method is appropriate for the analysis of a given validation suite. An example of the validation decision making flow is shown in Fig.1. As shown in Fig. 1, the analyst performing the validation fits a trend line to the data and performs a test to determine if the trend was a statistically better representation of the data than if it were treated as an uncorrelated sample. If the trend line is a better representation of the data, then the analyst uses any one of a number of trending techniques to determine the bias and bias uncertainty. If a trend is not an appropriate representation of the data, then the analyst proceeds to perform a normality assessment for the data. If the normal assumption can be shown to be acceptable, then the analyst calculates the bias and bias uncertainty with the parametric technique. If the assumption of normality cannot be justified, then the nonparametric technique is used. Once the decision flow has been followed and the appropriate technique has been selected, the bias and bias uncertainty is typically combined with an administrative margin to determine a USL below which calculated values of k eff for safety analysis models can be considered subcritical. The calculations used in each decision are often performed with spreadsheets or with small programs available at various sites performing criticality analyses. Expertise in understanding and interpreting the results must be maintained to perform these calculations. This can often be an error-prone process. Oak Ridge National Laboratory (ORNL) is currently developing the Validation and Data Evaluation Resource (VADER) to simplify and automate the criticality safety validation process and to provide a software quality assurance pedigree to the calculational methods used. This paper discusses the use of the Fulcrum user interface with VADER, the anticipated initial capabilities of VADER to perform validation analyses, and the output from the code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bibliography on contaminants and solubility of organic compounds in oxygen

A compilation of a number of document citations is presented which contains information on contaminants in oxygen. Topics covered include contaminants and solubility of organic compounds in oxygen, reaction characteristics of organic compounds with oxygen, and sampling and detection limits of impurities. Each citation in the data bank contains many items of information about the document. Some of the items are title, author, abstract, corporate source, description of figures pertinent to hazards or safety, key references, and descriptors (keywords) by which the document can be retrieved. Each citation includes an evaluation of the technical contents as to being good/excellent, acceptable, or poor. The descriptors used to define the contents of the documents and subsequently used in the computerized search operations were developed for the cryogenic fluid safety by experts in the cryogenics field.

Ordin, P. M.↗

Breadboard Signal Processor for Arraying DSN Antennas

A recently developed breadboard version of an advanced signal processor for arraying many antennas in NASA s Deep Space Network (DSN) can accept inputs in a 500-MHz-wide frequency band from six antennas. The next breadboard version is expected to accept inputs from 16 antennas, and a following developed version is expected to be designed according to an architecture that will be scalable to accept inputs from as many as 400 antennas. These and similar signal processors could also be used for combining multiple wide-band signals in non-DSN applications, including very-long-baseline interferometry and telecommunications. This signal processor performs functions of a wide-band FX correlator and a beam-forming signal combiner. [The term "FX" signifies that the digital samples of two given signals are fast Fourier transformed (F), then the fast Fourier transforms of the two signals are multiplied (X) prior to accumulation.] In this processor, the signals from the various antennas are broken up into channels in the frequency domain (see figure). In each frequency channel, the data from each antenna are correlated against the data from each other antenna; this is done for all antenna baselines (that is, for all antenna pairs). The results of the correlations are used to obtain calibration data to align the antenna signals in both phase and delay. Data from the various antenna frequency channels are also combined and calibration corrections are applied. The frequency-domain data thus combined are then synthesized back to the time domain for passing on to a telemetry receiver

Jongeling, Andre↗

Progress Towards Treating the Sludges Produced During Spent Fuel Processing - 19546

As a consequence of over 50 years of Magnox reprocessing, Sellafield site is in possession of significant quantities of Magnox sludge. This sludge material is the by-product of corrosion of the magnesium based Magnox metal that clads the Magnox fuel elements. Retrievals and processing of this material poses a significant challenge as corrosion of Magnox metal has occurred under a variety of conditions and over a significant period of time, in a variety of locations. Devising processes to treat heterogeneous materials offers a significant challenge to identify technologies with robust envelopes of acceptance, to effectively operate together. This is further compounded by difficulties defining test programmes and materials for testing that will provide assurance that nonradioactive testing is suitably representative or bounding. An overview of the significant body of work undertaken to process Sellafield's Magnox sludge is provided, from the thousands of commercially sensitive reports generated over the past five decades. This covers the sampling, characterisation, strategy and process evolution, technology development and test materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Correcting evaluation bias of relational classifiers with network cross validation

Recently, a number of modeling techniques have been developed for data mining and machine learning in relational and network domains where the instances are not independent and identically distributed (i.i.d.). These methods specifically exploit the statistical dependencies among instances in order to improve classification accuracy. However, there has been little focus on how these same dependencies affect our ability to draw accurate conclusions about the performance of the models. More specifically, the complex link structure and attribute dependencies in relational data violate the assumptions of many conventional statistical tests and make it difficult to use these tests to assess the models in an unbiased manner. In this work, we examine the task of within-network classification and the question of whether two algorithms will learn models that will result in significantly different levels of performance. We show that the commonly used form of evaluation (paired t-test on overlapping network samples) can result in an unacceptable level of Type I error. Furthermore, we show that Type I error increases as (1) the correlation among instances increases and (2) the size of the evaluation set increases (i.e., the proportion of labeled nodes in the network decreases). Lastly, we propose a method for network cross-validation that combined with paired t-tests produces more acceptable levels of Type I error while still providing reasonable levels of statistical power (i.e., 1–Type II error).

97 MATHEMATICS AND COMPUTING↗

Vivianite oxidation is not photocatalyzed

Vivianite is a hydrous Fe2+ phosphate mineral found in anoxic environments that plays an integral role in P cycling and environmental biogeochemistry. Imbued in the vivianite literature dating as far back as 1918 is the notion that vivianite is light-sensitive and susceptible to rapid photooxidation induced entirely by solar light. However, despite an exhaustive search, to our knowledge this conventionally accepted assumption has never been directly tested, nor has the band gap ever been measured. Resolving this question of photochemical control of vivianite redox chemistry is important for performing and interpreting experiments involving vivianite reactivity with contaminants, and potentially iron and phosphate cycling in the photic zone of aquatic systems. The present study was specifically designed to add¬ress this question. Pure synthetic vivianite samples were irradiated in aqueous suspensions with a Xe lamp at conditions mimicking the solar spectrum and compared to dark controls. Particles stirred in anoxic suspensions for up to 66 days showed no detectable oxidation irrespective of light exposure, according to colorimetric Fe2+/Fe3+ assays, micro X-ray diffraction, and Raman spectroscopy. In contrast, the same experiment performed using air-equilibrated suspensions showed systematic oxidation of up to ~80% mol% Fe(II) at 66 days, but again with no detectable light exposure effect. To test for UV reactivity, further experiments on vivianite powders under air versus N2 atmosphere were performed using a Hg lamp with a longpass filter. In contrast to oxidation in air where no effect of light was detected, after 24 hrs irradiation anoxically, 0.78% Fe was oxidized compared to dark controls, and after 13 days only an additional 0.3% Fe was oxidized. The band gap of pure vivianite was measured by the Tauc method to be 3.5 eV. Contrary to previous reports, solar light has minimal impact on the oxidation of pure vivianite, insignificant in particular when compared to its relatively fast oxidation by oxygen exposure. As such, light does not need to be excluded when running typical vivianite laboratory experiments. Long-term storage of natural vivianite in museums or private collections should continue protective measures given that a possible photocatalytic role of impurities cannot yet be ruled out. Nonetheless, at all depths in natural aquatic systems it appears that the primary abiotic control on the reactivity and half-life of vivianite particles should be the dissolved oxygen concentration, not light exposure.

Vivianite, photochemistry, oxidation↗

Antiferromagnetic order and the structural order-disorder transition in the Cd 6 Ho quasicrystal approximant

It has generally been accepted that the orientational ordering of the Cd 4 tetrahedron within the Cd 6 R quasicrystal approximants is kinetically inhibited for R = Ho, Er, Tm and Lu by steric constraints. Our high-resolution X-ray scattering measurements of the Cd 6 Ho quasicrystal approximant, however, reveal an abrupt (first-order) transition to a monoclinic structure below T S = 178 K for samples that have ‘aged’ at room temperature for approximately one year, reopening this question. Using X-ray resonant magnetic scattering at the Ho L 3 -edge we have elucidated the nature of the antiferromagnetic ordering below T N = 8.5 K in Cd 6 Ho. The magnetic Bragg peaks are found at the charge forbidden H + K + L = 2n + 1 positions, referenced to the high-temperature body-centred cubic structure. In general terms, this corresponds to antiferromagnetic arrangements of the Ho moments on adjacent clusters in the unit cell as previously found for Cd 6 Tb.

Kreyssig, Andreas↗

SALTSTONE 3QCY10 TCLP RESULTS

The Saltstone Production Facility (SPF) receives waste from Tank 50H for treatment. In the third quarter of the 2010 calendar year (3QCY10), Tank 50H accepted transfers of approximately 76 kgal from the Effluent Treatment Project (ETP), approximately 7 kgal from Tank 710 - the HCanyon General Purpose Evaporator, approximately 57 kgal from the H-Canyon Super Kukla campaign, approximately 58 kgal from the Modular Caustic Side Solvent Extraction Unit (MCU) Decontaminated Salt Solution Hold Tank (DSS-HT), and approximately 6 kgal from other sources. The Saltstone Grout Sampling plan provides the South Carolina Department of Health and Environmental Control (SCDHEC) with the chemical and physical characterization strategy for the salt solution which is to be disposed of in the Z-Area Solid Waste Landfill (ISWLF). During operation, samples were collected from Tank 50H and grout samples prepared to determine the non-hazardous nature of the grout to meet the requirements of the South Carolina Hazardous Waste Management Regulations (SCHWMR) R.61-79.261.24(b) and R.61-79.268.48(a). Savannah River National Laboratory (SRNL) was asked to prepare saltstone from samples of Tank 50H obtained July 1, 2010 during 3QCY10 to determine the non-hazardous nature of the grout. The samples were cured and shipped to Babcock & Wilcox Technical Services Group-Radioisotope and Analytical Chemistry Laboratory (B&W TSG-RACL) to perform the Toxic Characteristic Leaching Procedure (TCLP) and subsequent extract analysis on saltstone samples for the analytes required for the quarterly analysis saltstone sample. In addition to the eight toxic metals - arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver - analytes included the underlying hazardous constituents (UHC) antimony, beryllium, nickel, and thallium which could not be eliminated from analysis by process knowledge. B&W TSG-RACL provided subsamples to GEL Laboratories, LLC for analysis for the UHCs benzene, phenols and total and amenable cyanide.

36 MATERIALS SCIENCE↗

Spatial variation in microbial processes controlling carbon mineralization within soils and sediments

Soils have a defining role in global carbon cycling, having one of the largest dynamic stocks of C on earth—3300 Pg of C are stored in soils, which is three-times the amount stored in the atmosphere and more than the terrestrial land plants. An important control on soil organic matter (SOM) quantities is the mineralization rate. It is well recognized that the rate and extent of SOM mineralization is affected by climatic factors and mineral-organic matter associations. What remained elusive is to what extent constraints on microbial metabolism induced by the respiratory pathway, and specifically the electron acceptor in respiration, control overall rates of carbon mineralization in soils. Therefore, physical factors limiting oxygen diffusion such as soil texture and aggregate size (soil structure) may therefore be central controls on C mineralization rates. The goal of our research was therefore to determine if variations in microbial metabolic rates induced by anaerobic microsites in soils are a major control on SOM mineralization rates and thus storage. We performed a combination of laboratory experiments and field investigations will be performed to fulfill our research objectives. We used laboratory studies to examine fundamental factors of respiratory constraints (i.e., electron acceptor) on organic matter mineralization rates. We ground our laboratory studies with both manipulation of field samples and in-field measurements. Selection of the field sites is guided by variation in soil texture and structure while having (other environmental/soil factors constant. Our laboratory studies defined redox gradients and variations in microbial metabolism operating at the aggregate-scale (cm-scale) within soils using a novel constructed diffusion reactor. We further examined micro-scale variation in terminal electron accepting processes and resulting C mineralization rates within re-packed soils. A major outcome of our research is the ability to quantitatively place the importance of aggregate-based heterogeneity in microbial redox processes and the resulting lack of oxygen on the rate of carbon mineralization. Collectively, our research shows that anaerobic microsites are prevalent in soils and are important regulators of soil carbon persistence, shifting microbial metabolism to less efficient anaerobic respiration and selectively protecting otherwise bioavailable, reduced organic compounds such as lipids and waxes from decomposition. Further, shifting from anaerobic to aerobic conditions leads to a 10-fold increase in volume-specific mineralization rate, illustrating the sensitivity of anaerobically protected carbon to disturbance. Vulnerability of anaerobically protected carbon to future climate or land use change thus constitutes a yet unrecognized soil carbon-climate feedback that should be incorporated into terrestrial ecosystem models.

54 ENVIRONMENTAL SCIENCES↗

Extreme ultraviolet reflectivity studies of gold on glass and metal substrates

The paper reports measurements of the extreme ultraviolet reflectivity of gold from 44 to 920 A at grazing incidence. Gold was deposited using vacuum evaporation and electroplating on substrates of glass and polished nickel, respectively. Measurements are also presented of the extreme ultraviolet reflectivity of electroless nickel in the same wavelength region, where one of the polished nickel substrates was used as a sample. Derived optical constants for evaporated and electroplated gold and electroless nickel are presented. Additional studies of the effects of various contaminants on the EUV reflectivity are also reported. The variations of the optical constants are discussed in terms of density variations, surface roughness and contamination effects. These results ae reported as part of studies for the Extreme Ultraviolet Explorer satellite program to determine acceptance criteria for the EUV optics, contamination budgets and calibration plans.

Jelinsky, Sharon R.↗