Search NASA⌕ Search

SEARCH · Search NASA

Results for “activation volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Integrated Analysis of Multiple User Metrics - A “Sequel”; and Introducing the Google Analytic

For decades, the Goddard Earth Sciences Data and Information Services Center (GES DISC) has archived and distributed enormous volumes of NASA Earth science data (accompanied with many developed tools and services) to various research/applications communities and the general public. Being “immersed” in the Big Data era, we have inevitably faced the challenges of our continually increasing archived data in both volume and variety, as well as enhanced user needs and demands. In recent years, we have actively analyzed different types of user metrics, such as operational distribution metrics (recording numbers of distinct users and downloaded data files, size of distributed data volume): user publication metrics (mining info from our Giovanni users’ publications): and Bugzilla metrics (collecting info from user questions or feedback from user assistance tickets). Such metrics have helped us achieve a better understanding of user needs, demands, characteristics, and behaviors, which has then helped us improve our user services. Now we will present a “Sequel” of integrated analysis of multiple metrics at the GES DISC by introducing and adding one new kind of metrics acquired via utilizing our recently implemented Google Analytic 360 suite. Several “newer” reports, e.g., “What web site features and links are the most popular (and least)?” and “What are the top 25 dataset Keyword searches?” retrieved from this new metrics set will be presented, along with the aforementioned “traditional” metrics results.

Shie, Chung-Lin↗

Stacked Cu 1.8 S nanoplatelets as Counter Electrode for Quantum Dot-Sensitized Solar Cell

It is found that electrocatalytic activity of Cu 2-x S thin films used in quantum dots sensitized solar cells (QDSSC) as countner electrode (CE) for the reduction of polysulfide electrolyte depends on the the surface active sulfur species and defficiency of Cu. The preferential bonding between Cu 2+ and S 2- leading to the selective formation of Cu 1.8 S stacked platelets like morphology is determined by Cetyl Trimethyl Ammonium Bromide surfactant with temperature and crab like Cu-S coordination bond formed dictates the surface area to volume ratio of the Cu 1.8 S thin films and the electrocatalytic activity. The Cu deficiency enhances the conductivity of the Cu 1.8 S thin films and exhibits near- infrared localized surface plasmon resonanc due to free carrier intraband absorption and UV-VIS absorption spectra shows excitonic effect due to quantum size effect. When these Cu 1.8 S thin films were employed as CE in QDSSC, robust photoconversion efficiency of 5.2 % is yielded by the film deposited at 60°C by a sinlge step chemical bath deposition method.

Environmental Molecular Sciences Laboratory↗

Flat-plate solar array project. Volume 6: Engineering sciences and reliability

The Flat-Plate Solar Array (FSA) Project activities directed at developing the engineering technology base required to achieve modules that meet the functional, safety, and reliability requirements of large scale terrestrial photovoltaic systems applications are reported. These activities included: (1) development of functional, safety, and reliability requirements for such applications; (2) development of the engineering analytical approaches, test techniques, and design solutions required to meet the requirements; (3) synthesis and procurement of candidate designs for test and evaluation; and (4) performance of extensive testing, evaluation, and failure analysis of define design shortfalls and, thus, areas requiring additional research and development. A summary of the approach and technical outcome of these activities are provided along with a complete bibliography of the published documentation covering the detailed accomplishments and technologies developed.

Ross, R. G., Jr.↗

Volume 35, AMT-1 Cruise Report and Preliminary Results

This report documents the scientific activities on board the Royal Research Ship (RRS) 'James Clark Ross' during the irst Atlantic Meridional Transect (AMT-1), 21 September to 24 October 1995. The ship sailed from Grimsby (England) for Montevideo (Uruguay) and then continued on to Stanley (Falkland Islands). The primary objective of the AMT program is to investigate basic biological processes in the open Atlantic Ocean over very broad spatial scales. For AMT-1, the meridional range covered was approximately 50 deg N to 50 deg S or nearly 8,000 nmi. The measurements to be taken during the AMT cruises are fundamental for the calibration, validation, and continuing understanding of remotely sensed observations of biological oceanography. They are also important for understanding plankton community structure over latitudinal scales and the role of the world ocean in global carbon cycles. During AMT-1 a variety of instruments were used to map the physical, chemical, and biological structure of the upper 200 m of the water column. Ocean color measurements were made using state-of-the-art sensors, whose calibration was traceable to the highest international standards. New advances in fluorometry were used to measure photosynthetic activity, which was then used to further interpret primary productivity. A unique set of samples and data were collected for the planktonic assemblages that vary throughout the range of the transect. These data will yield new interpretations on community composition and their role in carbon cycling. While the various provinces of the Atlantic Ocean were being crossed, the partial pressure of CO2 was related to biological productivity. This comparison revealed the areas of drawdown of atmospheric CO2 and how these areas relate to the surrounding biological productivity. These data, plus the measurements of light attenuation and phytoplankton optical properties, will be used as a primary input for basin-scale biological productivity models to help develop ecosystem dynamics models which will be important for improving the forecasting abilities of modelers. The AMT program is also attempting to meet the needs of international agencies in their implementation of Sensor Intercomparison and Merger for Biological and Interdisciplinary Ocean Studies (SIMBIOS), a program to develop a methodology and operational capability to combine data products from the various ocean color satellite missions.

Hooker, Stanford B.↗

Application of activity pencil beam algorithm using measured distribution data of positron emitter nuclei for therapeutic SOBP proton beam

Purpose: Recently, much research on imaging the clinical proton-irradiated volume using positron emitter nuclei based on target nuclear fragment reaction has been carried out. The purpose of this study is to develop an activity pencil beam (APB) algorithm for a simulation system for proton-activated positron-emitting imaging in clinical proton therapy using spread-out Bragg peak (SOBP) beams.Methods: The target nuclei of activity distribution calculations are {sup 12}C nuclei, {sup 16}O nuclei, and {sup 40}Ca nuclei, which are the main elements in a human body. Depth activity distributions with SOBP beam irradiations were obtained from the material information of ridge filter (RF) and depth activity distributions of compounds of the three target nuclei measured by BOLPs-RGp (beam ON-LINE PET system mounted on a rotating gantry port) with mono-energetic Bragg peak (MONO) beam irradiations. The calculated data of depth activity distributions with SOBP beam irradiations were sorted in terms of kind of nucleus, energy of proton beam, SOBP width, and thickness of fine degrader (FD), which were verified. The calculated depth activity distributions with SOBP beam irradiations were compared with the measured ones. APB kernels were made from the calculated depth activity distributions with SOBP beam irradiations to construct a simulation system using the APB algorithm for SOBP beams.Results: The depth activity distributions were prepared using the material information of RF and the measured depth activity distributions with MONO beam irradiations for clinical therapy using SOBP beams. With the SOBP width widening, the distal fall-offs of depth activity distributions and the difference from the depth dose distributions were large. The shapes of the calculated depth activity distributions nearly agreed with those of the measured ones upon comparison between the two. The APB kernels of SOBP beams were prepared by making use of the data on depth activity distributions with SOBP beam irradiations that were made from the depth activity distributions with MONO beam irradiations and sorted in terms of energy, SOBP width, and thickness of FD. The data on APB kernels of SOBP beams were determined as installment data for the simulation system using the APB algorithm for SOBP beam irradiations.Conclusions: A method of obtaining the depth activity distributions and the APB algorithm for clinical use of SOBP beams have been developed. It is suggested that the simulation system for imaging the clinical irradiated volume with the APB algorithm can be used in clinical proton therapy using SOBP beams by preparing and investigating the data on APB kernels of SOBP beams.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide↗

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD↗

Virus-Like Particles (VLPs) as a Platform for Hierarchical Compartmentalization

Hierarchically self-assembled structures are common in biology, but it is often challenging to design and fabricate synthetic analogs. The archetypal cell is defined by hierarchically organized multicompartmentalized structures with boundaries that delineate the interior from exterior environments and is an inspiration for complex functional materials. Here, we have demonstrated an approach to the design and construction of a nested protein cage system that can additionally incorporate the packing of other functional macromolecules and exhibit some of the features of a minimal synthetic cell-like material. We have demonstrated a strategy for controlled co-packaging of subcompartments, ferritin (Fn) cages, together with active cellobiose-hydrolyzing β-glycosidase enzyme macromolecules, CelB, inside the sequestered volume of the bacteriophage P22 capsid. Using controlled in vitro assembly, we were able to modulate the stoichiometry of Fn cages and CelB encapsulated inside the P22 to control the degree of compartmentalization. The co-encapsulated enzyme CelB showed catalytic activity even when packaged at high total macromolecular concentrations comparable to an intracellular environment. Here, this approach could be used as a model to create synthetic protein-based protocells that can confine smaller functionalized proto-organelles and additional macromolecules to support a range of biochemical reactions.

59 BASIC BIOLOGICAL SCIENCES↗

The Characterization of Thermal Properties of Intumescent Foams for D and D Activities

DOE-EM, SRNL, and sites across the complex have identified an operational requirement for a fire resistant fixative technology that is intended to immobilize and/or fixate residual radioactive contamination within a 3-dimensional void of varying volumes that might result from anticipated to unanticipated events to include normal operating conditions, D and D activities, and radiological release. Foaming fixative shall not generate heat sufficient to compromise any of the components within the enclosure to which it is applied, The foaming fixative shall not generate heat sufficient to self-ignite the foaming fixative material. (as per ASTM Standard E3191- 18, Section 7.10 and 7.11). Introduction to Intumescent Technologies: Intumesce: to grow and to increase in volume against heat, or to show an expanding effect by bubbling. The fundamental processes involved in polymer flammability include: preheating, decomposition, ignition, and combustion and propagation. When heated beyond its critical temperature, an intumescent foam will swell 50-100 times its original size. Goals: To explore the feasibility of applying intumescent foams to fill symmetrical and asymmetrical 3-dimensional large void areas. Use a thermodynamics approach to develop viable nondestructive evaluation methods to determining anomalies and inconsistencies in the application and foam curing process. Intumescent foams as a permanent foaming fixative: ASTM foam standard was developed (ASTM E3191-18 Standard Specification for Permanent Foaming Fixatives Used to Mitigate Spread of Radioactive Contamination). Test objective: To determine a possible correlation between temperature profile during curing and inconsistencies in application or curing. Hypothesis: There is a correlation between temperature profile and curing/application. Future Work: Adapting intumescent foams to serve as a radioactive/radiological fixative.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of in vivo quantification accuracy of the Ingenuity-TF PET/MR

Purpose: The quantitative accuracy of standardized uptake values (SUVs) and tracer kinetic uptake parameters in patient investigations strongly depends on accurate determination of regional activity concentrations in positron emission tomography (PET) data. This determination rests on the assumption that the given scanner calibration is valid in vivo. In a previous study, we introduced a method to test this assumption. This method allows to identify discrepancies in quantitative accuracy in vivo by comparison of activity concentrations of urine samples measured in a well-counter with activity concentrations extracted from PET images of the bladder. In the present study, we have applied this method to the Philips Ingenuity-TF PET/MR since at the present stage, absolute quantitative accuracy of combined PET/MR systems is still under investigation. Methods: Twenty one clinical whole-body F18-FDG scans were included in this study. The bladder region was imaged as the last bed position and urine samples were collected afterward. PET images were reconstructed including MR-based attenuation correction with and without truncation compensation and 3D regions-of-interest (ROIs) of the bladder were delineated by three observers. To exclude partial volume effects, ROIs were concentrically shrunk by 8–10 mm. Then, activity concentrations were determined in the PET images for the bladder and for the urine by measuring the samples in a calibrated well-counter. In addition, linearity measurements of SUV vs singles rate and measurements of the stability of the coincidence rate of “true” events of the PET/MR system were performed over a period of 4 months. Results: The measured in vivo activity concentrations were significantly lower in PET/MR than in the well-counter with a ratio of the former to the latter of 0.756 ± 0.060 (mean ± std. dev.), a range of 0.604–0.858, and a P value of 3.9 ⋅ 10{sup −14}. While the stability measurements of the coincidence rate of “true” events showed no relevant deviation over time, the linearity scans revealed a systematic error of 8%–11% (avg. 9%) for the range of singles rates present in the bladder scans. After correcting for this systematic bias caused by shortcomings of the manufacturers calibration procedure, the PET to well-counter ratio increased to 0.832 ± 0.064 (0.668 –0.941), P = 1.1 ⋅ 10{sup −10}. After compensating for truncation of the upper extremities in the MR-based attenuation maps, the ratio further improved to 0.871 ± 0.069 (0.693–0.992), P = 3.9 ⋅ 10{sup −8}. Conclusions: Our results show that the Philips PET/MR underestimates activity concentrations in the bladder by 17%, which is 7 percentage points (pp.) larger than in the previously investigated PET and PET/CT systems. We attribute this increased underestimation to remaining limitations of the MR-based attenuation correction. Our results suggest that only a 2 pp. larger underestimation of activity concentrations compared to PET/CT can be observed if compensation of attenuation truncation of the upper extremities is applied. Thus, quantification accuracy of the Philips Ingenuity-TF PET/MR can be considered acceptable for clinical purposes given the ±10% error margin in the EANM guidelines. The comparison of PET images from the bladder region with urine samples has proven a useful method. It might be interesting for evaluation and comparison of the in vivo quantitative accuracy of PET, PET/CT, and especially PET/MR systems from different manufacturers or in multicenter trials.

60 APPLIED LIFE SCIENCES↗

KATRIN background due to surface radioimpurities

The goal of the KArlsruhe TRItrium Neutrino (KATRIN) experiment is the determination of the effective electron antineutrino mass with a sensitivity of 0.2 eV/c 2 at 90 % C.L. 1 . This goal can only be achieved with a very low background level in the order of 10 mcps 2 in the detector region of interest. A possible background source are α-decays on the inner surface of the KATRIN Main Spectrometer. Rydberg atoms, produced in sputtering processes accompanying the α-decays, are not influenced by electric or magnetic fields and freely propagate inside the vacuum of the Main Spectrometer. Here, they can be ionized by thermal radiation and the released electrons directly contribute to the KATRIN background. Two α-sources, 223 Ra and 228 Th, were installed at the Main Spectrometer with the purpose of temporarily increasing the background in order to study α-decay induced background processes. In this paper, we present a possible background generation mechanism and measurements performed with these two radioactive sources. Our results show a clear correlation between α-activity on the inner spectrometer surface and background from the volume of the spectrometer. Two key characteristics of the Main Spectrometer background – the dependency on the inner electrode offset potential, and the radial distribution – could be reproduced with this artificially induced background. These findings indicate a high contribution of α-decay induced events to the residual KATRIN background.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cell diameter measurements obtained with a handheld cell counter could be used as a surrogate marker of G2/M arrest and apoptosis in colon cancer cell lines exposed to SN-38

Highlights: •Chemo-sensitivity to SN-38 was assayed by the automated cell counter. •Colon cancer cell line, HCT116 cells were more sensitive to SN-38 than HT29 cells. •Increase of cell size reflects G2/M arrest. •Appearance of small particles indicates cell apoptosis. -- Abstract: In vitro assessment of chemosensitivity are important for experiments evaluating cancer therapies. The Scepter 2.0 cell counter, an automated handheld device based on the Coulter principle of impedance-based particle detection, enables the accurate discrimination of cell populations according to cell size and volume. In this study, the effects of SN-38, the active metabolite of irinotecan, on the colon cancer cell lines HCT116 and HT29 were evaluated using this device. The cell count data obtained with the Scepter counter were compared with those obtained with the {sup 3}H-thymidine uptake assay, which has been used to measure cell proliferation in many previous studies. In addition, we examined whether the changes in the size distributions of these cells reflected alterations in the frequency of cell cycle arrest and/or apoptosis induced by SN-38 treatment. In our experiments using the Scepter 2.0 cell counter, the cell counts were demonstrated to be accurate and reproducible measure and alterations of cell diameter reflected G2/M cell cycle arrest and apoptosis. Our data show that easy-to-use cell counting tools can be utilized to evaluate the cell-killing effects of novel treatments on cancer cells in vitro.

60 APPLIED LIFE SCIENCES↗

Self-equilibrated backstresses induce compensation between hardening and softening: Micromechanical and microstructural features

For crystal plasticity formulation neglecting the strain gradients at the dislocation scale, backstresses are necessary to satisfy the mesoscopic stress equilibrium and strain compatibility requirements. Backstresses in a material point and those between neighboring points are treated separately. Physically backstresses can dynamically induce either hardening or softening effects to adjust the dislocation hardening of slip systems, whereas the sum of the stresses resulting in backstresses in the representative volume element (RVE) is zero. Backstress hardening suppresses certain slip activities, while backstress softening triggers excess dislocations. A two-phase brass is studied. Backstresses make the hard phase deform smaller and the soft phase deform more than those without employing backstresses in a model. In the former, more homogeneous lattice strain and higher yield stress are obtained. Backstress has limited effects on the evolution of the critical resolved shear stress and crystallographic texture. Furthermore, it is a major cause of the banded structures featuring sharp crystallographic contrasts which are not parallel to the slip planes. Tests indicate that backstress induces a serrated behavior at the early stages of deformation and induces the geometrically necessary bands (GNBs), which are parallel to the macroscopic axes.

36 MATERIALS SCIENCE↗

Galaxy Zoo DESI: large-scale bars as a secular mechanism for triggering AGNs

ABSTRACT Despite the evidence that supermassive black holes (SMBHs) co-evolve with their host galaxy, and that most of the growth of these SMBHs occurs via merger-free processes, the underlying mechanisms which drive this secular co-evolution are poorly understood. We investigate the role that both strong and weak large-scale galactic bars play in mediating this relationship. Using 48 871 disc galaxies in a volume-limited sample from Galaxy Zoo DESI, we analyse the active galactic nucleus (AGN) fraction in strongly barred, weakly barred, and unbarred galaxies up to $z = 0.1$ over a range of stellar masses and colours. After controlling for stellar mass and colour, we find that the optically selected AGN fraction is $31.6 \pm 0.9$ per cent in strongly barred galaxies, $23.3 \pm 0.8$ per cent in weakly barred galaxies, and $14.2 \pm 0.6$ per cent in unbarred disc galaxies. These are highly statistically robust results, strengthening the tantalizing results in earlier works. Strongly barred galaxies have a higher fraction of AGNs than weakly barred galaxies, which in turn have a higher fraction than unbarred galaxies. Thus, while bars are not required in order to grow an SMBH in a disc galaxy, large-scale galactic bars appear to facilitate AGN fuelling, and the presence of a strong bar makes a disc galaxy more than twice as likely to host an AGN than an unbarred galaxy at all galaxy stellar masses and colours.

Astronomy & Astrophysics↗

Study of the Heterogeneity of a Mixed-Conducting Electrochemical Electrode

The ionic resistance of membrane–electrode assemblies of oxygen–hydrogen fuel cell electrodes containing platinum nanoparticles on carbon black, carbon nanofibers, and proton-conducting Nafion polymer in a wide range of compositions (10–80 wt %) are studied in situ by the methods of current–voltage characteristics, electrochemical impedance spectroscopy, and simulation of the impedance hodograph. Conditions that make it possible to correctly determine the ionic resistance of the electrode on the basis of an analysis of the linear approximation of the high-frequency region of the impedance hodograph are found. It is shown that the occurrence of inhomogeneities and an anomalous increase in the ionic resistance with an increase in the content of Nafion in the electrode are associated with a decrease in the volume fraction of water-generation centers (particles of electrochemically active platinum), which leads to incomplete wetting of Nafion.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Comparing Experimentally-Measured Sand’s Times with Concentrated Solution Theory Predictions in a Polymer Electrolyte

We compare the electrochemically measured Sand’s time, the time required for the cell potential to diverge when the applied current density exceeds the limiting current, with theoretical predictions for a 0.47 M poly(ethylene oxide) (5 kg mol −1 )/LiTFSI electrolyte. The theoretical predictions are made using concentrated solution theory which accounts for both concentration polarization and polymer motion, using independently measured parameters that depend on concentration, c : conductivity ( κ ), salt diffusion coefficient ( D ), cationic transference number with respect to the solvent velocity ( t + 0 ), thermodynamic factor 1 + dln f ± dln c , and partial molar volume of the salt ( V ̅ ); f ± is the mean molar activity coefficient of the salt. We find quantitative agreement between experimental data and theoretical predictions. We derive a generalized analytical expression for Sand’s time for electrolytes based on dilute solution theory. This expression correctly predicts the divergence of the Sand’s time at the limiting current, in agreement with experimental data and concentrated solution theory predictions. When the applied current is large compared to the limiting current, the analytical expression approaches the standard expression for Sand’s time used in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrolyte and Cutoff Potential Effects on Cycle Life of Li4Ti5O12/LiNi0.9Mn0.1O2 Batteries for Behind-the-Meter Storage Applications

Behind-the-Meter Storage (BTMS) is a stationary battery energy storage system that is connected to the electrical distribution system on the customer's side of the utility's service meter. BTMS systems are used to store electrical energy from the grid as well as inconstant, renewable energy, such as local solar and wind generation. A successful BTMS system will allow the customer to pair their energy generation and storage to optimize electrical consumption from the grid, improving reliability and minimizing cost. For BTMS applications, batteries must be designed and optimized with different set of criteria from other leading segments of the Li-ion battery market, like transportation, due the system being stationary and proximal to the residential or commercial building it's benefitting. BTMS applications prioritize safety, cost (low/no-critical materials), reliability (20-year calendar life), and durability (10,000 cycle life), while having the ability to (minimally) compromise energy density and rate capability. Lithium titanate (Li4Ti5O12-, LTO) is a promising anode candidate for BTMS applications due to its high safety and capacity retention, while maintaining a reasonable 160 mAhg-1 reversable capacity and composition of relatively abundant materials. (1) Specifically, LTO has a high working voltage which helps to prevent Li dendrite formation, improving safety. Furthermore, LTO also has negligible lithiation-based volume change, leading to less mechanical pulverization, or loss of active material, upon cycling. For the cathode, materials with little or no Co are of high interest due to the high cost and low abundance of Co. LiMn2O4 (LMO) has been paired with LTO for BTMS applications in the past due to its safety, low cost (abundancy), and reasonably high operating voltage. (2-4) However, the low capacity of LMO limits energy density and specific energy. While not the highest priority for BTMS applications, increasing energy density will enable deployment in space constrained BTMS applications and decrease total cost. LiNi0.9Mn0.1O2 (LN-MO) is a recently developed material with promise due to its high operating voltage and relatively low price. (5) However, Ni-rich layered oxides, including LNMO, tend to struggle with capacity retention during high-voltage cycling due to mechanical pulverization, irreversible phase transitions, and unstable solid-electrolyte interphase. The study presented here focuses on building an understanding of how electrolyte solvent and varied cutoff potentials will impact the cycle life of LTO/LN-MO cells. Specifically, a comparison is provided between ethylene carbonate (EC), ethyl methyl carbonate (EMC), fluoroethylene carbonate (FEC), and Gen2 electrolyte solvents with 1M Lithium hexafluorophosphate (LiPF6) salt, cycling to two upper termination potentials, 2.6V and 2.7V. Electrochemical testing and diagnostics (e.g., differential capacity analysis, area specific impedance, constant voltage hold, and rate capability) and post-mortem characterization will be used to understand the aging behavior and failure mechanisms of the 8 cell combinations (four electrolytes and two voltage cutoffs). Cells with FEC electrolyte showed a lower initial capacity compared to cells with Gen2, EMC, and EC cycling at both voltages; however, the cells with FEC showed consistent trends in capacity retention with 2.6V and 2.7V termination potentials, while the cells with the other electrolytes showed much higher rates of capacity loss when cycling to the higher voltage. These results indicate that FEC may play a role in improving durability of high-voltage, Ni-rich electrode systems for use in high-cycle applications, such as BTMS.

electrolyte↗