Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Electronic angle focusing for neutron time-of-flight powder diffractometers

A neutron time-of-flight (TOF) powder diffractometer with a continuous wide-angle array of detectors can be electronically focused to make a single pseudo-constant wavelength diffraction pattern, thus facilitating angle-dependent intensity corrections. The resulting powder diffraction peak profiles are affected by the neutron source emission profile and resemble the function currently used for TOF diffraction.

electronic focusing↗

Passive Neutron Detection at Borders

Radiation portal monitor systems have been deployed to screen for illicit trafficking of radioactive materials at international border crossings. This report reviews some of the neutron detection requirements and capabilities of passive detection systems used for such applications. Simulations show the effects of cargo materials on neutron spectra, different detector geometries, using a large-array of neutron detectors, and the effects of backgrounds including “ship effect” neutrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental evaluation of an online gamma-camera imaging of permanent seed implantation (OGIPSI) prototype for partial breast irradiation

Previously, our team used Monte Carlo simulation to demonstrate that a gamma camera could potentially be used as an online image guidance device to visualize seeds during permanent breast seed implant procedures. This could allow for intraoperative correction if seeds have been misplaced. The objective of this study is to describe an experimental evaluation of an online gamma-camera imaging of permanent seed implantation (OGIPSI) prototype. The OGIPSI device is intended to be able to detect a seed misplacement of 5 mm or more within an imaging time of 2 min or less. The device was constructed by fitting a custom built brass collimator (16 mm height, 0.65 mm hole pitch, 0.15 mm septal thickness) on a 64 pixel linear array CZT detector (eValuator-2000, eV Products, Saxonburg, PA). Two-dimensional projection images of seed distributions were acquired by the use of a digitally controlled translation stage. Spatial resolution and noise characteristics of the detector were measured. The ability and time needed for the OGIPSI device to image the seeds and to detect cold spots was tested using an anthropomorphic breast phantom. Mimicking a real treatment plan, a total of 52 {sup 103}Pd seeds of 65.8 MBq each were placed on three different layers at appropriate depths within the phantom. The seeds were reliably detected within 30 s with a median error in localization of 1 mm. In conclusion, an OGIPSI device can potentially be used for image guidance of permanent brachytherapy applications in the breast and, possibly, other sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-438: Commissioning of An In-Vivo Quality Assurance Method Using the Electronic Portal Imaging Device

Purpose: Patient specific pre-treatment quality assurance (QA) using arrays of detectors or film have been the standard approach to assure the correct treatment is delivered to the patient. This QA approach is expensive, labor intensive and does not guarantee or document that all remaining fractions were treated properly. The purpose of this abstract is to commission and evaluate the performance of a commercially available in-vivo QA software using the electronic portal imaging device (EPID) to record the daily treatments. Methods: The platform EPIgray V2.0.2 (Dosisoft), which machine model compares ratios of TMR with EPID signal to predict dose was commissioned for an Artiste (Siemens Oncology Care Systems) and a Truebeam (Varian medical systems) linear accelerator following the given instructions. The systems were then tested on three different phantoms (homogeneous stack of solid water, anthropomorphic head and pelvis) and on a library of patient cases. Simple and complex fields were delivered at different exposures and for different gantry angles. The effects of the table attenuation and the EPID sagging were evaluated. Gamma analysis of the measured dose was compared to the predicted dose for complex clinical IMRT cases. Results: Commissioning of the EPIgray system for two photon energies took 8 hours. The difference between the dose planned and the dose measured with EPIgray was better than 3% for all phantom scenarios tested. Preliminary results on patients demonstrate an accuracy of 5% is achievable in high dose regions for both 3DCRT and IMRT. Large discrepancies (>5%) were observed due to metallic structures or air cavities and in low dose areas. Flat panel sagging was visible and accounted for in the EPIgray model. Conclusion: The accuracy achieved by EPIgray is sufficient to document the safe delivery of complex IMRT treatments. Future work will evaluate EPIgray for VMAT and high dose rate deliveries. This work is supported by Dosisoft, Cachan, France.

60 APPLIED LIFE SCIENCES↗

Recording of ultrahigh-energy astrophysical neutrinos

This review is devoted to the problems of recording ultrahigh-energy neutrinos produced in distant astrophysical sources and during the decay of supermassive particles. Prospects for the detection of neutrino fluxes are considered based on peculiarities of the propagation and interaction of ultrahigh-energy neutrinos. The operating and planned facilities designed to investigate neutrinos from various sources are described: neutrino telescopes recording neutrino interactions in natural water and ice volumes; ground-based arrays of detectors and optical telescopes onboard orbital space stations capable of detecting neutrino-triggered horizontal air showers. Instruments based on new principles of recording neutrinos with extremely high energies are considered: radio telescopes designed to observe Cherenkov radio emission from neutrino cascades originating in such radio-transparent natural environments as the atmosphere, salt domes, ice packs, and lunar regolith; underwater acoustic detectors. It is shown that putting new facilities into operation will allow neutrinos from most of the known astrophysical sources with energies differing by more than ten orders of magnitude, from 10{sup 12} to 10{sup 22}–10{sup 24} eV, to be recorded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reply to “Comment on ‘The Reduced Detection Rate of Signals That Are Hidden by Earthquakes: Case Studies with Spotlight Detectors That Operate at Seismic Arrays,’ by Joshua D. Carmichael, Brent G. Delbridge, and Richard Alfaro-Diaz” by Paul G. Richards

We reply to a comment that Paul G. Richards (Richards, 2026) directed to an article by Carmichael et al. (2025). Richards expressed concern over two issues. The first issue relates to the size of the explosions discussed in the article. The second relates to the probability that earthquakes and explosions sourced near the same location coincide in time, by chance. We do not address the first issue because the original article does not assign significance to the size of the explosions from the point of view of an experimental party. We do respond to Richards’ comment on the second issue and claim that it can be explained through a clarification about conditional versus joint probabilities. Our present discussion, therefore, describes the difference between the conditional probability that a correlator fails, given that an explosion and earthquake coincidently occur in the same place, and the joint probability that a correlator fails while an earthquake and explosion also coincidentally occur in the same place. This latter, joint probability appears to be rare. We clarify that our original article did not treat the joint probability, only the conditional probability.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Microseismic Event Detection Using Multiple Geophone Arrays in Southwestern Utah

We conducted four geophone array experiments in southwestern Utah between July 2016 and October 2017 to characterize regional levels of microseismicity. Each experiment comprised between 48 and 93 geophones and recorded continuously for ~30 days. Using a new frequency domain array-based detector and a traditional STA/LTA detector, we identified 242 earthquakes. We were able to precisely locate 203 of these earthquakes using HYPOINVERSE. During the same time period the University of Utah Seismograph Stations (UUSS) catalog contained 68 earthquakes in the study area, therefore, we were able to locate 135 additional events. We estimate local magnitudes for events using maximum peak-to-trough amplitude and epicentral distance. As expected, our detection threshold becomes lower with higher station density. We find sparse seismicity across the study area apart from two areas that contain clustered and more frequent activity (Dog Valley and Cove Fort), which together account for roughly 70% of the recorded seismicity. A third prominent cluster in the central Mineral Mountains contains about 15% of the recorded seismicity. Lastly, the remainder of the detected seismicity is spread across the study area.

58 GEOSCIENCES↗

Passive Heterodyne Detection Using Multiple Spatial Modes

We investigated the utility of passive heterodyne detection for the remote sensing of chemicals. We performed sensor simulations for a heterodyne receiver that operates with multiple spatial modes of radiation. We find that the heterodyne signals associated with distinct spatial modes of radiation can be detected in combination. We compare this to the well-known concept referred to as the “Siegman antenna theorem”, which is usually interpreted as limiting heterodyne receivers to a single spatial mode. We show that the heterodyne signal/noise ratio does not improve beyond the single-mode SNR. We discuss the possibility of performing imaging in the multi-mode configuration, using a multi-mirror array or an array heterodyne detector. We conclude that multiple-mode passive heterodyne sensing requires a bright source of radiation, since the combination of the modes does not boost the SNR. We discuss why passive heterodyne imaging is potentially feasible.

42 ENGINEERING↗

Annual Report FY2013-- A Kinematically Complete, Interdisciplinary, and Co-Institutional Measurement of the 19F(α,n) Cross-section for Nuclear Safeguards Science

The goal of this proposal is to enable neutron detection for precision Non-Destructive Assays (NDAs) of actinide-fluoride samples. Neutrons are continuously generated from a UFx matrix in a container or sample as a result of the interaction of alpha particles from uranium-decay α particles with fluorine nuclei in the matrix. Neutrons from 19F(α,n)22Na were once considered a poorly characterized background for assays of UFx samples via 238U spontaneous fission neutron detection [SMI2010B]. However, the yield of decay-α-driven neutrons is critical for 234,235U LEU and HEU assays, as it can used to determine both the total amount of uranium and the enrichment [BER2010]. This approach can be extremely valuable in a variety of safeguard applications, such as cylinder monitoring in underground uranium storage facilities, nuclear criticality safety studies, nuclear materials accounting, and other nonproliferation applications. The success of neutron-based assays critically depends on an accurate knowledge of the cross section of the (α,n) reaction that generates the neutrons. The 40% uncertainty in the 19F(α,n)22Na cross section currently limits the precision of such assays, and has been identified as a key factor in preventing accurate enrichment determinations [CRO2003]. The need for higher quality cross section data for (α,n) reactions has been a recurring conclusion in reviews of the nuclear data needs to support safeguards. The overarching goal of this project is to enable neutron detection to be used for precision Non- Destructive Assays (NDAs) of actinide-fluoride samples. This will significantly advance safeguards verification at existing declared facilities, nuclear materials accounting, process control, nuclear criticality safety monitoring, and a variety of other nonproliferation applications. To reach this goal, Idaho National Laboratory (INL), in partnership with Oak Ridge National Laboratory (ORNL), Rutgers University (RU), and the University of Notre Dame (UND), will focus on three specific items: (1) making a precision (better than 10 %) determination of the absolute cross section of the 19F(α,n)22Na reaction as a function of energy; (2) determining the spectrum of neutrons and γ-rays emitted from 19F(α,n)22Na over an energy range pertinent to NDA; and (3) performing simulations with this new cross section to extract the neutron yield (neutrons/gram/second) and resulting neutron- and gamma ray-spectra when α particles interact with fluorine nuclei in actinide samples, to aid in the design and reduce uncertainty of future NDA measurements and simulations.

VANDLE, HPGe gamma-ray detector, liquid neutron de↗

The extraction of the spin structure function, g2 (and g1) at low Bjorken x

The Spin Asymmetries of the Nucleon Experiment (SANE) used the Continuous Electron Beam Accelerator Facility at Jefferson Laboratory in Newport News, VA to investigate the spin structure of the proton. The experiment measured inclusive double polarization electron asymmetries using a polarized electron beam, scattered off a solid polarized ammonia target with target polarization aligned longitudinal and near transverse to the electron beam, allowing the extraction of the spin asymmetries A1 and A2, and spin structure functions g1 and g2. Polarized electrons of energies of 4.7 and 5.9 GeV were used. The scattered electrons were detected by a novel, non-magnetic array of detectors observing a four-momentum transfer range of 2.5 to 6.5 GeV*V. This document addresses the extraction of the spin asymmetries and spin structure functions, with a focus on spin structure function, g2 (and g1) at low Bjorken x. The spin structure functions were measured as a function of x and W in four Q square bins. A full understanding of the low x region is necessary to get clean results for SANE and extend our understanding of the kinematic region at low x.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Pierre Auger Observatory Upgrade - Preliminary Design Report

The Pierre Auger Observatory has begun a major Upgrade of its already impressive capabilities, with an emphasis on improved mass composition determination using the surface detectors of the Observatory. Known as AugerPrime, the upgrade will include new 4 m 2 plastic scintillator detectors on top of all 1660 water-Cherenkov detectors, updated and more flexible surface detector electronics, a large array of buried muon detectors, and an extended duty cycle for operations of the fluorescence detectors. This Preliminary Design Report was produced by the Collaboration in April 2015 as an internal document and information for funding agencies. It outlines the scientific and technical case for AugerPrime. We now release it to the public via the arXiv server. We invite you to review the large number of fundamental results already achieved by the Observatory and our plans for the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing Proton Spin Structure: A Measurement of g 2 at Four-momentum Transfer of 2 to 6 GeV 2

The Spin Asymmetries of the Nucleon Experiment investigated the spin structure of the proton via inclusive electron scattering at the Continuous Electron Beam Accelerator Facility at Jefferson Laboratory in Newport News, VA. A double-polarization measurement of polarized asymmetries was performed using the University of Virginia solid polarized ammonia target with target polarization aligned longitudinal and near transverse to the electron beam, allowing the extraction of the spin asymmetries A 1 and A 2 , and spin structure functions g 1 and g 2 . Polarized electrons of energies of 4.7 and 5.9 GeV were scattered to be viewed by a novel, non-magnetic array of detectors observing a four-momentum transfer range of 2 to 6 GeV 2 . This document addresses the extraction of the spin asymmetries and spin structure functions, with a focus on spin structure function g 2 , which we have measured as a function of x and W in four Q 2 bins.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

24.1.3.1 - Verification of Spent Fuel Inside Dry Storage Casks by Fast/Epi-thermal Neutron Mapping

Development of a spent-fuel verification method based upon positional measurement of fast neutrons emitted from the top surface of the dry storage casks. A proof-of-principle field test on a partially loaded spent-fuel cask will be conducted by measuring the fast neutron flux on the top of the cask as a function of position using a single detector. If a useful verification signature is demonstrated, a multi-detector scanning array will be built and tested in FY2021 to demonstrate a practical rapid verification system in FY2022.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rossi Alpha Measurements – Rapid Organic (n, $\gamma$) Discrimination Detector (RAM-RODD) system capabilities

The Rossi Alpha Measurements–Rapid Organic (n, $\gamma$) Discrimination Detector (RAM-RODD) is an array organic scintillation detectors that has been optimized for use in neutron noise measurements. This report details the capability of the system including the method of energy calibration, pulse shape discrimination, and time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Verification of Spent Fuel Inside Dry Storage Casks Using Neutron Mapping (2022 Midyear Report)

Development of a spent-fuel verification method based upon positional measurement of fast neutrons emitted from the top surface of the dry storage casks. A proof-of-principle field test on a partially loaded spent-fuel cask will be conducted by measuring the fast neutron flux on the top of the cask as a function of position using a single detector. If a useful verification signature is demonstrated, a multi-detector scanning array will be built and tested to demonstrate a practical rapid verification system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Urban Deployment Model: A Toolset for the Simulation and Performance Characterization of Radiation Detector Deployments in Urban Environments

Static and mobile radiation detectors can be deployed in urban environments for a range of nuclear security applications, including radiological source search-and-tracking scenarios. Modeling detector performance for such applications is challenging, as it does not depend solely on the detector capabilities themselves. Many factors must be taken into consideration, including specific source and background signatures, the topology and constraints of the deployment environment, the presence of nuisance sources, and whether detectors are mobile or static. When considering the simultaneous deployment of multiple, heterogeneous detectors, assessment of the system-wide performance requires the simulation of the individual detectors, and a system-level analysis of the detection performance. In radiological source search-and-tracking scenarios, performance is mostly dominated by the probability of encounter, which depends on the specifics of a given deployment, e.g., static vs. mobile detectors or a combination of both modalities, the number of detectors deployed, the dynamic vs. static setting of false alarm rates, and individual vs. networked operation. The Urban Deployment Model (UDM) toolset was specifically developed to cover the gap in the available generic frameworks for the simulation of radiation detector deployments at city scales. UDM provides a unified and modular framework to support the simulation and performance characterization of heterogeneous detector deployments in urban environments. This paper presents the key components along the UDM workflow.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

An inverse source location algorithm for radiation portal monitor applications

Radiation portal monitors are being deployed at border crossings throughout the world to prevent the smuggling of nuclear and radiological materials; however, a tension exists between security and the free-flow of commerce. Delays at ports-of-entry have major economic implications, so it is imperative to minimize portal monitor screening time. We have developed an algorithm to locate a radioactive source using a distributed array of detectors, specifically for use at border crossings. To locate the source, we formulated an optimization problem where the objective function describes the least-squares difference between the actual and predicted detector measurements. The predicted measurements are calculated by solving the 3-D deterministic neutron transport equation given an estimated source position. The source position is updated using the steepest descent method, where the gradient of the objective function with respect to the source position is calculated using adjoint transport calculations. If the objective function is smaller than the convergence criterion, then the source position has been identified. This paper presents the derivation of the underlying equations in the algorithm as well as several computational test cases used to characterize its accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗