Search NASA⌕ Search

SEARCH · Search NASA

Results for “biomedical data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Radiation-induced aging of PDMS Elastomer TR-55: a summary of constitutive, mesoscale, and population-based models

Filled and cross-linked elastomeric rubbers are versatile network materials with a multitude of applications ranging from artificial organs and biomedical devices to cushions, coatings, adhesives, interconnects, and seismic-isolation-, thermal-, and electrical barriers. External factors like mechanical stress, temperature fluctuations, or radiation are known to create chemical changes in such materials that can directly affect the molecular weight distribution (MWD) of the polymer between cross-links and alter the structural and mechanical properties. From a Materials Science point of view it is highly desirable to understand, effect, and manipulate such property changes in a controlled manner. In this report we summarize our modeling efforts on a polysiloxane elastomer TR-55, which is an important component in several of our systems, and representative of a wide class of filled rubber materials. The primary aging driver in this work has been γ-radiation, and a variety of modeling approaches have been employed, including constitutive, mesoscale, and population-based models. The work utilizes diverse experimental data, including mechanical stress-strain and compression set measurements, as well as MWD measurements using multiquantum NMR.

36 MATERIALS SCIENCE↗

Evidence of pathogenic microbes in the International Space Station drinking water: reason for concern?

Molecular analyses were carried out on four preflight and six postflight International Space Station (ISS)-associated potable water samples at various stages of purification, storage, and transport, to ascertain their associated microbial diversities and overall microbial burdens. Following DNA extraction, PCR amplification, and molecular cloning procedures, rDNA sequences closely related to pathogenic species of Acidovorax, Afipia, Brevundimonas, Propionibacterium, Serratia, and others were recovered in varying abundance. Retrieval of sequences arising from the iodine (biocide)-reducing Delftia acidovorans in postflight waters is also of concern. Total microbial burdens of ISS potable waters were derived from data generated by an ATP-based enumeration procedure, with results ranging from 0 to 4.9 x 10(4) cells/ml. Regardless of innate biases in sample collection and analysis, such circumstantial evidence for the presence of viable, intact pathogenic cells should not be taken lightly. Implementation of new cultivation approaches and/or viability-based assays are requisite to confirm such an occurrence.

STS-113 Shuttle Project↗

Palonosetron-A Single-Dose Antiemetic Adjunct for Hepatic Artery Radioembolization: A Feasibility Study

Nausea and vomiting may occur in a significant minority of patients following hepatic artery embolization with yttrium-90 spheres (K. T. Sato et al. Radiology 247:507-515, 2008). This encumbers human and economic resources and undercuts the assertion that it is as a well-tolerated outpatient treatment. A single intravenous dose of palonosetron HCl was administered before hepatic artery embolization with yttrium-90 spheres to ameliorate posttreatment nausea and vomiting, in 23 consecutive patients. The patients were discharged the day of procedure on oral antiemetics, steroids, and blockers of gastric acid release. All patients had clinical and laboratory evaluation at 2 weeks after the procedure. The data were gathered and reviewed retrospectively. At 2-week follow-up, none reported significant nausea, vomiting, additional antiemetic use, need for parenteral therapy, hospital readmission, or palonosetron-related side effects. All patients recovered from postembolization symptoms within a week after treatment. In conclusion, this retrospective study suggests that single-dose palonosetron is feasible, safe, and effective for acute and delayed nausea and vomiting in this group of patients. The added cost may be offset by benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differential elastic responses to barrier-altering agonists in two types of human lung endothelium

Vascular integrity is primarily determined by endothelial cell (EC) cytoskeletal structure that is differentially regulated by various stimuli. In this study, atomic force microscopy (AFM) was used to characterize structural and mechanical properties in the cytoskeleton of cultured human pulmonary artery EC (HPAEC) and human lung microvascular EC (HLMVEC) by determining elastic properties (Young's modulus) in response to endogenous barrier protective agents sphingosine 1-phosphate (S1P) and hepatocyte growth factor (HGF), or the barrier disruptive molecule thrombin. Initial studies in unstimulated cells indicate higher baseline peripheral elastic modulus values in HPAEC (mean 2.9 KPa) than in HLMVEC (1.8 KPa). After 30 min of stimulation, S1P induced the highest Young's modulus increase (6.1 KPa) compared to the other barrier enhancing stimuli, HGF (5.8 KPa) and the pharmaceutical agent and S1P analog FTY720 (4.1 KPa). In contrast, the barrier disruptive agent thrombin decreased values from 2.5 KPa to 0.7 KPa depending on the cell type and treatment time. AFM topographical imaging supports these quantitative biophysical data regarding differential peripheral elastic properties in EC. Overall, these AFM studies provide novel insights into the biomechanical properties of human lung EC that regulate vascular barrier function and have potential applicability to pathophysiologic vascular leak syndromes such as acute lung injury. - Highlights: • AFM dynamically measures cellular biophysical properties in live endothelial cells. • Macrovascular human lung EC exhibit different biophysical responses than microvascular. • Agonists that promote EC barrier function increase peripheral elastic properties. • Provide insights into potential therapeutic modulation of human lung EC.

60 APPLIED LIFE SCIENCES↗

WE-H-207A-03: The Universality of the Lognormal Behavior of [F-18]FLT PET SUV Measurements

Purpose: Log transforming [F-18]FDG PET standardized uptake values (SUVs) has been shown to lead to normal SUV distributions, which allows utilization of powerful parametric statistical models. This study identified the optimal transformation leading to normally distributed [F-18]FLT PET SUVs from solid tumors and offers an example of how normal distributions permits analysis of non-independent/correlated measurements. Methods: Forty patients with various metastatic diseases underwent up to six FLT PET/CT scans during treatment. Tumors were identified by nuclear medicine physician and manually segmented. Average uptake was extracted for each patient giving a global SUVmean (gSUVmean) for each scan. The Shapiro-Wilk test was used to test distribution normality. One parameter Box-Cox transformations were applied to each of the six gSUVmean distributions and the optimal transformation was found by selecting the parameter that maximized the Shapiro-Wilk test statistic. The relationship between gSUVmean and a serum biomarker (VEGF) collected at imaging timepoints was determined using a linear mixed effects model (LMEM), which accounted for correlated/non-independent measurements from the same individual. Results: Untransformed gSUVmean distributions were found to be significantly non-normal (p<0.05). The optimal transformation parameter had a value of 0.3 (95%CI: −0.4 to 1.6). Given the optimal parameter was close to zero (which corresponds to log transformation), the data were subsequently log transformed. All log transformed gSUVmean distributions were normally distributed (p>0.10 for all timepoints). Log transformed data were incorporated into the LMEM. VEGF serum levels significantly correlated with gSUVmean (p<0.001), revealing log-linear relationship between SUVs and underlying biology. Conclusion: Failure to account for correlated/non-independent measurements can lead to invalid conclusions and motivated transformation to normally distributed SUVs. The log transformation was found to be close to optimal and sufficient for obtaining normally distributed FLT PET SUVs. These transformations allow utilization of powerful LMEMs when analyzing quantitative imaging metrics.

60 APPLIED LIFE SCIENCES↗

Reducing variability in the output of pattern classifiers using histogram shaping

Purpose: The authors present a novel technique based on histogram shaping to reduce the variability in the output and (sensitivity, specificity) pairs of pattern classifiers with identical ROC curves, but differently distributed outputs. Methods: The authors identify different sources of variability in the output of linear pattern classifiers with identical ROC curves, which also result in classifiers with differently distributed outputs. They theoretically develop a novel technique based on the matching of the histograms of these differently distributed pattern classifier outputs to reduce the variability in their (sensitivity, specificity) pairs at fixed decision thresholds, and to reduce the variability in their actual output values. They empirically demonstrate the efficacy of the proposed technique by means of analyses on the simulated data and real world mammography data. Results: For the simulated data, with three different known sources of variability, and for the real world mammography data with unknown sources of variability, the proposed classifier output calibration technique significantly reduced the variability in the classifiers' (sensitivity, specificity) pairs at fixed decision thresholds. Furthermore, for classifiers with monotonically or approximately monotonically related output variables, the histogram shaping technique also significantly reduced the variability in their actual output values. Conclusions: Classifier output calibration based on histogram shaping can be successfully employed to reduce the variability in the output values and (sensitivity, specificity) pairs of pattern classifiers with identical ROC curves, but differently distributed outputs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-FG-207-00: Technological Advances in PET/MR Imaging

The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

60 APPLIED LIFE SCIENCES↗

Anniversary Paper: History and status of CAD and quantitative image analysis: The role of Medical Physics and AAPM

The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists' goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities that are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists--as opposed to a completely automatic computer interpretation--focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous--from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects--collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more--from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Specific recommendations for accurate and direct use of PET-CT in PET guided radiotherapy for head and neck sites

Purpose: To provide specific experience-based guidance and recommendations for centers wishing to develop, validate, and implement an accurate and efficient process for directly using positron emission tomography-computed tomography (PET-CT) for the radiotherapy planning of head and neck cancer patients. Methods: A PET-CT system was modified with hard-top couch, external lasers and radiotherapy immobilization and indexing devices and was subject to a commissioning and quality assurance program. PET-CT imaging protocols were developed specifically for radiotherapy planning and the image quality and pathway tested using phantoms and five patients recruited into an in-house study. Security and accuracy of data transfer was tested throughout the whole data pathway. The patient pathway was fully established and tested ready for implementation in a PET-guided dose-escalation trial for head and neck cancer patients. Results: Couch deflection was greater than for departmental CT simulator machines. An area of high attenuation in the couch generated image artifacts and adjustments were made accordingly. Using newly developed protocols CT image quality was suitable to maintain delineation and treatment accuracy. Upon transfer of data to the treatment planning system a half pixel offset between PET and CT was observed and corrected. By taking this into account, PET to CT alignment accuracy was maintained below 1 mm in all systems in the data pathway. Transfer of structures delineated in the PET fusion software to the radiotherapy treatment planning system was validated. Conclusions: A method to perform direct PET-guided radiotherapy planning was successfully validated and specific recommendations were developed to assist other centers. Of major concern is ensuring that the quality of PET and CT data is appropriate for radiotherapy treatment planning and on-treatment verification. Couch movements can be compromised, bore-size can be a limitation for certain immobilization techniques, laser positioning may affect setup accuracy and couch deflection may be greater than scanners dedicated to radiotherapy. The full set of departmental commissioning and routine quality assurance tests applied to radiotherapy CT simulators must be carried out on the PET-CT scanner. CT image quality must be optimized for radiotherapy planning whilst understanding that the appearance will differ between scanners and may affect delineation. PET-CT quality assurance schedules will need to be added to and modified to incorporate radiotherapy quality assurance. Methods of working for radiotherapy and PET staff will change to take into account considerations of both parties. PET to CT alignment must be subject to quality control on a loaded and unloaded couch preferably using a suitable emission phantom, and tested throughout the whole data pathway. Data integrity must be tested throughout the whole pathway and a system included to verify that delineated structures are transferred correctly. Excellent multidisciplinary team communication and working is vital, and key staff members on both sides should be specifically dedicated to the project. Patient pathway should be clearly devised to optimize patient care and the resources of all departments. Recruitment of a cohort of patients into a methodology study is valuable to test the quality assurance methods and pathway.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analytic variance estimates of Swank and Fano factors

Purpose: Variance estimates for detector energy resolution metrics can be used as stopping criteria in Monte Carlo simulations for the purpose of ensuring a small uncertainty of those metrics and for the design of variance reduction techniques. Methods: The authors derive an estimate for the variance of two energy resolution metrics, the Swank factor and the Fano factor, in terms of statistical moments that can be accumulated without significant computational overhead. The authors examine the accuracy of these two estimators and demonstrate how the estimates of the coefficient of variation of the Swank and Fano factors behave with data from a Monte Carlo simulation of an indirect x-ray imaging detector. Results: The authors' analyses suggest that the accuracy of their variance estimators is appropriate for estimating the actual variances of the Swank and Fano factors for a variety of distributions of detector outputs. Conclusions: The variance estimators derived in this work provide a computationally convenient way to estimate the error or coefficient of variation of the Swank and Fano factors during Monte Carlo simulations of radiation imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of surface–solute interactions by diffusioosmosis

The accurate measurement of wall zeta potentials and solute–surface interaction length scales for electrolyte and non-electrolyte solutes, respectively, is critical to the design of many biomedical and microfluidic applications. We present a novel microfluidic approach using diffusioosmosis for measuring either the zeta potentials or the characteristic interaction length scales for surfaces exposed to, respectively, electrolyte or non-electrolyte solutes. When flows containing different solute concentrations merge in a junction, local solute concentration gradients can drive diffusioosmotic flow due to electrokinetic, steric, and other interactions between the solute molecules and solid surfaces. We demonstrate a microfluidic system consisting of a long, narrow pore connecting two large side channels in which solute concentration gradients drive diffusioosmosis within the pore, resulting in predictable fluid velocity/pressure and solute profiles. Furthermore, we present analytical results and a methodology to determine the zeta potential or interaction length scale for the pore surfaces based on the solute concentrations in the main side channels, the flow rate in the pore, and the pressure drop across the pore. We apply this method to the experimental data of Lee et al. to predict the zeta potentials of their system, and we use 3D numerical simulations to validate the theory and show that end effects caused by the junctions are negligible for a wide range of parameters. Because the dynamics in the proposed system are driven by diffusioosmosis, this technique does not suffer from certain disadvantages associated with the use of sensitive electronics in traditional zeta potential measurement approaches such as streaming potential, streaming current, or electroosmosis. As a result, to the best of our knowledge this is the first flow-based approach to characterize surface/solute interactions with non-electrolyte solutes.

42 ENGINEERING↗

Reduction of ocular counter-rolling by adaptation to space

We studied the three-dimensional vestibulo-ocular reflex (VOR) of rhesus monkeys before and after the COSMOS Biosatellite 2229 Mission of 1992-1993. This included tests of ocular counter-rolling (OCR), the gain of the vestibulo-ocular reflex (VOR), and spatial orientation of velocity storage. A four-axis vestibular and oculomotor stimulator was transported to the Institute of Biomedical Problems in Moscow for the pre- and postflight ground-based testing. Twelve normal juvenile male rhesus monkey were implanted surgically with eye coils and tested 60-90 days before spaceflight. Two monkey (7906 and 6151), selected from the twelve as flight animals, flew from 12/29/92 to 1/10/93. Upon recovery, they were tested for 11 days postflight along with three control animals. Compensatory ocular torsion was produced in two ways: (1) Lateral head tilts evoked OCR through otolith-ocular reflexes. OCR was also measured dynamically during off-vertical axis rotation (OVAR). (2) Rotation about a naso-occipital axis that was either vertical of horizontal elicited torsional nystagmus through semicircular canal-ocular reflexes (roll VOR). OCR from the otoliths was substantially reduced (70 percent) for 11 days after reentry on both modes of testing. The gain of the roll VOR was also decreased, but less than OCR. These data demonstrate that there was a long-lasting depression of torsional or roll eye movements after adaptation to microgravity in these monkeys, especially those movements produced by the otolith organs.

Dai, Mingjia↗

Neutron, fluorescence, and optical imaging: An in situ combination of complementary techniques

An apparatus which enables the simultaneous combination of three complementary imaging techniques, optical imaging, fluorescence imaging, and neutron radiography, is presented. While each individual technique can provide information on certain aspects of the sample and their time evolution, a combination of the three techniques in one setup provides a more complete and consistent data set. The setup can be used in transmission and reflection modes and thus with optically transparent as well as opaque samples. Its capabilities are illustrated with two examples. A polymer hydrogel represents a transparent sample and the diffusion of fluorescent particles into and through this polymer matrix is followed. In reflection mode, the absorption of solvent by a nile red-functionalized mesoporous silica powder and the corresponding change in fluorescent signal are studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-D-BRE-01: A Sr-90 Irradiation Device for the Study of Cutaneous Radiation Injury

Purpose: To determine dosimetric character for a custom-built Sr-90 beta irradiator designed for the study of Cutaneous Radiation Injury (CRI) in a porcine animal model. In the event of a radiological accident or terrorist event, Sr-90, a fission by-product, will likely be produced. CRI is a main concern due to the low energy and superficial penetration in tissue of beta particles from Sr-90. Seven 100 mCi plaque Sr-90 radiation sources within a custom-built irradiation device create a 40 mm diameter region of radiation-induced skin injury as part of a larger project to study the efficacy of a topical keratin-based product in CRI healing. Methods: A custom-built mobile irradiation device was designed and implemented for in vivo irradiations. Gafchromic™ EBT3 radiochromic film and a PTW Markus chamber type 23343 were utilized for dosimetric characterization of the beta fluence at the surface produced by this device. Films were used to assess 2-dimensional dose distribution and percent depth dose characteristics of the radiation field. Ion chamber measurements provided dose rate data within the field. Results: The radiation field produced by the irradiation device is homogeneous with high uniformity (∼5%) and symmetry (∼3%) with a steep dose fall-off with depth from the surface. Dose rates were determined to be 3.8 Gy/min and 3.3 Gy/min for film and ion chamber measurements, respectively. A dose rate of 3.4 Gy/min was used to calculate irradiation times for in vivo irradiations. Conclusion: The custom-built irradiation device enables the use of seven Sr-90 beta sources in an array to deliver a 40 mm diameter area of homogeneous skin dose with a dose rate that is useful for research purposes and clinically relevant for the induction of CRI. Doses of 36 and 42 Gy successfully produce Grade III CRI and are used in the study of the efficacy of KeraStat™. This project has been funded in whole or in part with Federal funds from the Biomedical Advanced Research and Development Authority, Office of the Assistant Secretary for Preparedness and Response, Office of the Secretary, Department of Health and Human Services, under Contract No. HHSO100201200007C.

07 ISOTOPE AND RADIATION SOURCES↗

MO-FG-207-01: Technological Advances and Challenges: Experience with the First Integrated Whole-Body PET/MRI

The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

60 APPLIED LIFE SCIENCES↗

MO-FG-207-02: Technological Advances and Challenges: Experience with Time-Of-Flight PET Combined with 3-Tesla MRI

The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

60 APPLIED LIFE SCIENCES↗

MO-FG-207-03: Maximizing the Utility of Integrated PET/MRI in Clinical Applications

The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

60 APPLIED LIFE SCIENCES↗

SU-F-J-184: Proton Computed Tomography Using 1D Silicon Diode Array

Purpose: Proton radiography and proton computed tomography (PCT) can be used to measure proton stopping power directly. However, practical and cost effective proton imaging detectors are not widely available. In this study, the authors investigated the feasibility of proton imaging using a silicon diode array. Methods: A one-dimensional silicon-diode detector array (1DSDA) was aligned with the central axis (CAX) of the proton beam. Polymethyl methacrylate (PMMA) slabs were used to find the correspondence between the water equivalent thickness (WET) and 1DSDA channel number. 2D proton radiographs (PR) were obtained by translation and rotation of a phantom relative to CAX while the proton nozzle and 1DSDA were kept stationary. A PCT image of one slice of the phantom was reconstructed using filtered backprojection. Results: PR and PCT images of the PMMA cube were successfully acquired using the 1DSDA. The WET of the phantom was measured using PR data with an accuracy of 4.2% or better. Structures down to 1 mm in size could be resolved. Reconstruction of a PCT image showed very good agreement with simulation. Limitations in spatial resolution are attributed to limited spatial sampling, beam collimation, and proton scatter. Conclusion: The results demonstrate the feasibility of using silicon diode arrays for proton imaging. Such a device can potentially offer fast image acquisition, high spatial and energy resolution for PR and PCT.

60 APPLIED LIFE SCIENCES↗