Search NASA⌕ Search

SEARCH · Search NASA

Results for “channel coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Transformational challenge reactor analysis to inform preconceptual core design decisions: Sensitivity study of transient analysis in a hydride-moderated microreactor

The Transformational Challenge Reactor (TCR) program aims to demonstrate a revolutionary design approach enabled by advanced manufacturing and data analytics in the design of nuclear reactors. This article discusses scoping analyses of preconceptual designs to inform TCR design decisions and the evaluation of sensitivities and uncertainties on postulated transient scenarios. The applicability of the systems codes TRACE and RELAP5-3D to TCR transient analysis are examined, and RELAP5-3D models are used to examine the transient response of two candidate core designs at multiple power levels. Then, the uncertainty quantification code RAVEN is used to quantify the effect of several design parameters on reactivity-initiated accident (RIA) progression at hot zero power (HZP) and hot full power (HFP) as well as to assess the impact of uncertainties in transient parameters for the pressurized loss of forced cooling (PLOFC).When results were compared, TRACE and RELAP5-3D showed good agreement in their ability to predict system behavior, but RELAP5-3D calculations were closer to analytical predictions for the RIA. Furthermore, models for a PLOFC accident in two designs (a UO2 and TRISO core) at multiple power levels showed greater temperature margins for the TRISO core at all power levels. Using this information, along with other scoping analyses and constraints, the TCR design team selected a power level of 3 MWth and a TRISO-based core design. For this design RAVEN was applied to vary RIA parameters in RELAP5-3D models at HZP and HFP to understand the effect on figures of merit such as peak power, fuel and coolant temperature, and energy deposition. This sensitivity study found that the inserted reactivity worth was the most important parameter controlling all figures of merit, but for insertion up to 1.5$ no failure of TCR fuel is anticipated. For constant reactivity insertions, the magnitude of the fuel temperature coefficient was found to have the greatest effect on all figures of merit under most circumstances. These results not only demonstrate the anticipated robust safety of the proposed TCR fuel form but also provide a reference for future metal-hydride moderated systems to understand RIA behavior. In the PLOFC, the impact of heat transfer enhancement due to wavy flow channel effects dominated the variance in peak temperatures, and variations in heat exchanger elevation provided the greatest control on natural circulation flow rate. Additionally, no fuel particle failure is anticipated in the PLOFC.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of, and defense against, spurious actuations and other incorrect behaviors of digital control systems - 390

Modern digital instrumentation and control (I and C) systems offer nearly unlimited functional capability. However, the complexity of their design (including their system software and application software) is significantly higher than that of conventional, hardwired systems, to the point that it is generally impossible to demonstrate that there are no residual design errors, even when the best development and verification techniques have been applied. When activated by specific conditions, design errors could result in systematic failures, i.e., failures that occur deterministically each time and wherever an activating condition is present. Redundancy could be defeated when the same design error affects multiple channels or systems, and the activating condition affects several of these channels or systems. In the case of safety I and C systems, most of the functions are poised protection functions that must be actuated when and only when a demand situation occurs in the plant. In nuclear power plants, the most dangerous failure mode for such functions generally is failure to actuate, and many measures are taken to protect from such failure mode. This paper considers the other failure modes of safety I and C functions, and also the failure modes of the other I and C functions that are less important to safety. It is not limited to poised functions, and considers other types of functions such as regulation functions or human interface functions. It proposes a framework for analyzing and providing defense against spurious actuations and other incorrect behaviors from digital I and C systems directly interacting with the plant process or with operators: these might be useful for example to justify that design bases for reactor protection are adequate, or to ensure plant performance and availability. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gyro-fluid and two-fluid theory and simulations of edge-localized-modes

This paper reports on the theoretical and simulation results of a gyro-Landau-fluid extension of the BOUT++ code, which contributes to increasing the physics understanding of edge-localized-modes (ELMs). Large ELMs with low-to-intermediate-n peeling-ballooning (P-B) modes are significantly suppressed due to finite Larmor radius (FLR) effects when the ion temperature increases. For type-I ELMs, it is found from linear simulations that retaining complete first order FLR corrections as resulting from the incomplete “gyroviscous cancellation” in Braginskii's two-fluid model is necessary to obtain good agreement with gyro-fluid results for high ion temperature cases (T{sub i}≽3 keV) when the ion density has a strong radial variation, which goes beyond the simple local model of ion diamagnetic stabilization of ideal ballooning modes. The maximum growth rate is inversely proportional to T{sub i} because the FLR effect is proportional to T{sub i}. The FLR effect is also proportional to toroidal mode number n, so for high n cases, the P-B mode is stabilized by FLR effects. Nonlinear gyro-fluid simulations show results that are similar to those from the two-fluid model, namely that the P-B modes trigger magnetic reconnection, which drives the collapse of the pedestal pressure. Due to the additional FLR-corrected nonlinear E × B convection of the ion gyro-center density, for a ballooning-dominated equilibrium the gyro-fluid model further limits the radial spreading of ELMs. In six-field two fluid simulations, the parallel thermal diffusivity is found to prevent the ELM encroachment further into core plasmas and therefore leads to steady state L-mode profiles. The simulation results show that most energy is lost via ion channel during an ELM event, followed by particle loss and electron energy loss. Because edge plasmas have significant spatial inhomogeneities and complicated boundary conditions, we have developed a fast non-Fourier method for the computation of Landau-fluid closure terms based on an accurate and tunable approximation. The accuracy and the fast computational scaling of the method have been demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FY22 Status Report on the ART-GCR CMVB and CNWG International Collaborations

This work presents the numerical model for the high temperature test reactor (HTTR) loss of forced cooling (LOFC) experiment with the INL codes Griffin, BISON, and RELAP-7, based on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Promising results were obtained, with the overall behavior of the reactor successfully captured. Changes in the heat transfer coupling, as compared to the fiscal year (FY)-21 model, enabled drastic improvement of the steady-state solution, both in terms of computational time and global energy discrepancies. The former was reduced by a factor of roughly 60, whereas the latter decreased from 11% to less than 2%. Furthermore, the discrepancy in the steady-state multiplication factor was improved from +2,300 and +2,900 pcm (for the 30 and 9 MW cases) to -700 and +1,200 pcm, respectively, and now falls well within the large measurement uncertainties stemming from graphite impurities. Validation of the Monte Carlo model used to generate cross sections was also performed against available measurements. Though significant, the discrepancies remain acceptable overall in light of the large uncertainty. Numerous improvements are still needed to better compare with the experiment involving the 9 MW case and to instill greater confidence in the model’s ability to accurately predict the 30 MW behavior. Specifically, the power levels predicted by the 9 MW transient simulation following re-criticality remain low, pointing to an underestimation of the passive cooling of the core. A key aspect of future work will be to better understand the flow pattern during the LOFC event, particularly to determine if natural or forced convection is occurring inside the reactor pressure vessel (RPV). More generally, additional validation data would be immensely useful for further enhancing the numerical model and better matching the experiments. In addition, a more sophisticated thermal-hydraulics model that simulates all the channels as a single system model should be considered to take into account the rest of the primary loop. Finally, even if the results are in better agreement with the experiments, sensitivity analysis and uncertainty quantification will be necessary to evaluate the model uncertainty.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improving deep learning-based protein distance prediction in CASP14

Abstract Motivation Accurate prediction of residue–residue distances is important for protein structure prediction. We developed several protein distance predictors based on a deep learning distance prediction method and blindly tested them in the 14th Critical Assessment of Protein Structure Prediction (CASP14). The prediction method uses deep residual neural networks with the channel-wise attention mechanism to classify the distance between every two residues into multiple distance intervals. The input features for the deep learning method include co-evolutionary features as well as other sequence-based features derived from multiple sequence alignments (MSAs). Three alignment methods are used with multiple protein sequence/profile databases to generate MSAs for input feature generation. Based on different configurations and training strategies of the deep learning method, five MULTICOM distance predictors were created to participate in the CASP14 experiment. Results Benchmarked on 37 hard CASP14 domains, the best performing MULTICOM predictor is ranked 5th out of 30 automated CASP14 distance prediction servers in terms of precision of top L/5 long-range contact predictions [i.e. classifying distances between two residues into two categories: in contact (<8 Angstrom) and not in contact otherwise] and performs better than the best CASP13 distance prediction method. The best performing MULTICOM predictor is also ranked 6th among automated server predictors in classifying inter-residue distances into 10 distance intervals defined by CASP14 according to the precision of distance classification. The results show that the quality and depth of MSAs depend on alignment methods and sequence databases and have a significant impact on the accuracy of distance prediction. Using larger training datasets and multiple complementary features improves prediction accuracy. However, the number of effective sequences in MSAs is only a weak indicator of the quality of MSAs and the accuracy of predicted distance maps. In contrast, there is a strong correlation between the accuracy of contact/distance predictions and the average probability of the predicted contacts, which can therefore be more effectively used to estimate the confidence of distance predictions and select predicted distance maps. Availability and implementation The software package, source code and data of DeepDist2 are freely available at https://github.com/multicom-toolbox/deepdist and https://zenodo.org/record/4712084#.YIIM13VKhQM. Supplementary information Supplementary data are available at Bioinformatics online.

59 BASIC BIOLOGICAL SCIENCES↗

Steady detonation propagation in thin channels with strong confinement

We examine asymptotically the dynamics of two-dimensional, steady detonation wave propagation and failure for a strongly confined high explosive (HE), in which the width of the explosive is small relative to the reaction zone length. An energy balance equation is derived, which shows how the longitudinal acceleration of subsonic flow behind the detonation shock is influenced both by chemical reaction and by the effects of HE boundary streamline deflection, specifically via the induced rate of change of mass flux through the detonation wave. The latter serves to either counteract or reinforce the acceleration of longitudinal flow, depending on the sign of the gradient of the boundary streamline deflection at the detonation shock. The analysis is valid for general equations of state and chemical reaction rates in the HE. The asymptotically derived form of the energy equation represents an eigenvalue problem for the determination of the steady detonation propagation speed, solved via a shooting method. We explore specific results for ideal and stiffened equations of state, along with a pressure-dependent reaction rate for which changes in the pressure exponent and reaction order are also studied. We consider the influences of both straight and curved HE boundary streamline shapes. The asymptotic analysis reveals significant physical insights into how detonation propagation and failure are affected by strong confinement.

42 ENGINEERING↗

SU-E-T-171: Characterization of the New Xoft Axxent Electronic Brachytherapy Source Using PRESAGE Dosimeters

Purpose: To characterize the Xoft Axxent electronic brachytherapy source using PRESAGE™ dosimeters to obtain independent confirmation of TG-43U1 dosimetry values from previous studies and ascertain its reproducibility in HDR brachytherapy. Methods: PRESAGE™ dosimeters are solid, polyurethane-based dosimeters doped with radiochromic leucodyes that produce a linear optical-density response when exposed to radiation. Eight 1-kg dosimeters were scanned prior to irradiation on an optical-CT scanner to eliminate background signal and any optical imperfections from each dosimeter. To quantify potential imaging artifacts due to oversaturated responses in the immediate range of the source, half of the eight dosimeters were cast with a smaller channel diameter of 5.4 mm, and the other half were cast with a larger channel diameter of 15mm. During irradiation, the catheters were placed in the center of each channel. Catheters fit the 5.4mm diameters channels whereas polyurethane plugs were inserted into the larger channels to create a sturdy, immobile catheter which allowed uniform dose distributions. Two dosimeters of each 5.4mm and 15mm were irradiated at either 1517.3 cGy or 2017.5 cGy. Post-irradiation scans were performed within 48 hours of irradiation. A 3D reconstruction based on subtraction of these two images and the relative dose measurements were made using in-house software. Results: Comparing measured radial dose rates with previous results revealed smaller percent errors when PRESAGE™ irradiations were at lower maximum dose. The dosimeters showed small deviations in radial dose function, g{sub p} (r), from previous studies. Among the dosimeters irradiated at 1517.3 cGy, the g{sub p}(r) compared to previous studies fluctuated from 0.0043 to 0.3922. This suggests small fluctuations can drastically change radial dose calculations. Conclusion: The subtraction of pre-irradiation and post-irradiation scans of PRESAGE™ dosimeters using an optical-CT scanner shows promising results in determining 3D dosimetry for Xoft Axxent devices; however, further research is recommended. NIH Grant#: 5-U24-CA081647-13; ROI Grant#: 5R01CA100835.

60 APPLIED LIFE SCIENCES↗

SU-E-T-348: Effect of Treatment Table and Immobilization Devices On Surface Dose When Using a GRID Technique

Purpose: To determine the increase of surface dose of MLC-designed GRID therapy in the presence of immobilization devices and treatment table. Methods: To create a GRID field, our facility utilizes an MLC consisting of four millimeter wide leaves. The field is designed to have aperture sizes of 0.8 cm X 0.8 cm with inter-aperture distance of 3.2 cm. Gafchromic EBT3 film was placed between the surface of a solid water phantom and the immobilization device. The treatment table was also present within the beam path. The devices consist of carbon fiber exterior shell. A piece of film was also placed at maximal depth for the photon energy of 10 MV. Image files were converted to dose per a calibration curve based on the selected red channel. The surface dose to maximum dose was established by comparing the ratio of seven centrally located aperture regions-of-interest and four adjacent inter-aperture regions-of-interest were measured with the available software tools. Results: With no devices present in beam path, the ratio of surface dose to maximum dose was 11.5% ± 0.3% for aperture region and 7.0% ± 0.1% for inter-aperture region. When devices are present, the ratio of surface dose to maximum dose was 45.2% ± 0.5% and 33.8% ± 1.1%, respectively. Due to the presence of devices, the surface dose increases in aperture region by 3.8 times or in the inter-aperture region by 4.7 times. Conclusion: The purpose of using GRID technique is to deliver a single fractional dose in range of 15–20 Gy to a bulky lesion while also preserving skin tolerance. The increase of surface dose due to devices placed in beam path may increase the chance of skin toxicity in GRID therapy. Care should be used to determine best manageable patient immobilization while considering skin dose especially for posteriorly located lesions.

60 APPLIED LIFE SCIENCES↗

Schneider Springs Fire Study 2023 for Ecosystem Respiration Rates: Surface Water Chemistry and Hydrologic Sensor Data across the Yakima River Basin, Washington, USA (v2)

This dataset supports a broader study examining the drivers of spatial variability in wildfire impacts across the Yakima River Basin. Data provided within this dataset were generated from sample collection across 17 total sites (8 sites affected by a recent wildfire, 9 sites unaffected by a recent wildfire) within multiple rivers throughout the Yakima River Basin in Washington, USA from May-July 2023. Fire affected sites are defined as those affected by the 2021 Schneider Springs Fire, based on the drainage area of the streams being within the 2021 Schneider Springs Fire burn perimeter or not (Figure 1, below). The contents include surface water geochemistry data (dissolved organic carbon; total dissolved nitrogen; total suspended solids); short-term sonde data (specific conductivity; turbidity; pH; chlorophyll A; temperature); stream depth data; stream velocity; manual chamber open channel respiration data; sensor time-series data (oxygen; water pressure; barometric pressure); field metadata (including qualitative information on in stream and river corridor characteristics); and environmental context photos taken in the field. The dataset also includes a summary file of the sensor data and plots of the sensor data. Sensors were only recovered at 15 out of the 17 sites, and not all sensors were recovered at all 15 sites (see Methods section for more details), therefore all data does not exist at all sites. Data from a 2022 study at the same sites, as well as additional sites, can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/1969566. The data package was originally published in November 2023. It was updated in June 2025 (v2; modified files). See the change history section in the readme for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset is comprised of one folder with field photos and one main data folder with two subfolders. The main data folder consists of (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) field protocol; (5) readme; (6) international generic sample number (IGSN) mapping file; and (7) stream depth and averages. The sensor data subfolder consists of (1) sensor installation methods summary; (2) stream velocity; and (3) six subfolders. The BarotrollAtm (barometric pressure; temperature), DepthHOBO (water pressure; temperature), MantaRiver (specific conductivity; turbidity; pH; chlorophyll A; temperature), EXO (specific conductivity; pH; temperature), miniDOT (dissolved oxygen; temperature), and miniDOTManualChamber (dissolved oxygen; temperature) contain time-series data, plots, and summary files. The sample data subfolder consists of (1) total suspended solids (TSS) data; (2) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data and averages; (3) total dissolved nitrogen (TN) data and averages; and (4) methods codes. All files are .csv, .pdf, .jpg, .jpeg, or .mov.

54 ENVIRONMENTAL SCIENCES↗

Evaluating an Exterior Insulation and Finish System for Deep Energy Retrofits

This report provides a case study of a deep energy retrofit using a site-applied exterior insulation and finish system (EIFS). Prefabricated EIFS panels are also discussed as a potential wall insulation retrofit solution. EIFSs are common in new and retrofit commercial construction. Such products typically consist of five layers installed over the top of a water resistive barrier as follows: (1) Adhesive (2) Foam insulation (3) Base coat (4) Reinforcing mesh embedded in the base coat (5) Top or finish coat. They can be applied to new or existing buildings that employ wood or masonry construction, and can utilize an insulation thickness of up to 16 in. However, such systems are rarely used in lowrise residential retrofits. Reasons for this might include a lack of demand for or knowledge of the systems in residential retrofit industry, high cost, and/or lack of suitable distribution channels serving the residential market. While the final appearance of an EIFS installation resembles stucco, it is a distinctly different system. Stucco is a generic cementitious-based material, whereas EIFSs are proprietary synthetic formulations distributed by manufacturers to a network of authorized applicators. An EIFS is composed of polymeric (organic) bonded aggregate and cement reinforced with a glass mesh. Stucco is made of inorganic cement, sand, and lime. In this project, a home was retrofitted using a site-applied 4-in.-thick EIFS. Site-specific details were developed as required for the residential retrofit application. Site work and the costs of the EIFS were documented. The case study home was modeled using version 2 of the National Renewable Energy Laboratory-developed Building Energy Optimization (BEopt) energy and cost analysis software. While a package utilizing the 4-in. EIFS is the optimal retrofit of the options analyzed in terms of annualized energy-related costs, it is higher cost than replacing the siding with midrange vinyl alone. However, compared to high-end vinyl, the EIFS package has a lower annualized energy cost. This held true for both the Islip, New York (climate zone 4) and Boston (climate zone 5) case studies. The report discusses the risks, selection criteria, interactions with other building systems, cost, performance, and other aspects of using an EIFS in a deep energy retrofit. EIFSs do not require special site safety precautions beyond general construction site precautions. Moisture design is important. Trapping moisture between two vapor/air barriers is a risk of all wall systems, including EIFS cladding applications if an interior vapor barrier exists and if there is not adequate ventilation through the drainage plane behind the insulation layer. Face-sealed approaches that rely on exposed sealants do not provide acceptable rain control or durability and are very risky. Generally, fire codes permit EIFSs for most building types and conditions.

airtightness↗

WE-FG-BRA-04: A Portable Confocal Microscope to Image Live Cell Damage Response Induced by Therapeutic Radiation

Purpose: To construct a custom and portable fluorescence confocal laser-scanning microscope (FCLSM) that can be placed in the path of therapeutic radiation beams to study real-time radiation-induced damage response in live cells. Methods: We designed and constructed a portable FCLSM with three laser diodes for excitation (405, 488, and 635 nm). An objective lens focuses the excitation light and collects fluorescence from the sample. A pair of galvanometer mirrors scans/collects the laser beam/fluorescence along the focal plane (x/y-directions). A stepper motor stage scans in the axial direction and positions the x/y of the image field. Barrier filters and dichroic mirrors are used to route the spectral emission bands to the appropriate photodetector. An avalanche photodiode collects near-infrared fluorescence; a photodiode collects back-reflected 635 nm light; and a photomultiplier tube collects green fluorescence in the range of eGFP/eYFP. A 200-µm diameter pinhole was used to implement the confocal geometry for near-infrared and red channels and a 150-µm diameter pinhole for the green channel. Data acquisition and system control were achieved using a high-throughput data acquisition card. In-house software developed in LabVIEW was used to control the hardware, collect data from the photodetectors and reconstruct the confocal images. Results: 6 frames/s can be acquired for a 25 µm{sup 2} (128×128 pixels) field of view, visualizing the entire volume of the cell nucleus (∼10 µm depth) in <10 s. To demonstrate the usefulness of our FCLSM, we imaged gold nanoshells in live cells, radiation-induced damage in fibrosarcoma cells expressing eGFP tagged to a DNA repair protein, and neurons expressing eGFP. The system can also image particle tracks in fluorescent nuclear track detectors. Conclusion: We developed a versatile and portable FCLSM that allows radiobiology studies in live cells exposed to therapeutic radiation. The FCLSM can be placed in any vertical beam line for top-to-bottom exposures. This research was supported by the Sister Institution Network Fund and the Center for Radiation Oncology Research at The University of Texas MD Anderson Cancer Center and Cancer Prevention and Research Institute of Texas. Gabriel Sawakuchi has research support from Elekta Inc.

60 APPLIED LIFE SCIENCES↗

SU-E-J-224: Multimodality Segmentation of Head and Neck Tumors

Purpose: Develop an algorithm that is able to automatically segment tumor volume in Head and Neck cancer by integrating information from CT, PET and MR imaging simultaneously. Methods: Twenty three patients that were recruited under an adaptive radiotherapy protocol had MR, CT and PET/CT scans within 2 months prior to start of radiotherapy. The patients had unresectable disease and were treated either with chemoradiotherapy or radiation therapy alone. Using the Velocity software, the PET/CT and MR (T1 weighted+contrast) scans were registered to the planning CT using deformable and rigid registration respectively. The PET and MR images were then resampled according to the registration to match the planning CT. The resampled images, together with the planning CT, were fed into a multi-channel segmentation algorithm, which is based on Gaussian mixture models and solved with the expectation-maximization algorithm and Markov random fields. A rectangular region of interest (ROI) was manually placed to identify the tumor area and facilitate the segmentation process. The auto-segmented tumor contours were compared with the gross tumor volume (GTV) manually defined by the physician. The volume difference and Dice similarity coefficient (DSC) between the manual and autosegmented GTV contours were calculated as the quantitative evaluation metrics. Results: The multimodality segmentation algorithm was applied to all 23 patients. The volumes of the auto-segmented GTV ranged from 18.4cc to 32.8cc. The average (range) volume difference between the manual and auto-segmented GTV was −42% (−32.8%–63.8%). The average DSC value was 0.62, ranging from 0.39 to 0.78. Conclusion: An algorithm for the automated definition of tumor volume using multiple imaging modalities simultaneously was successfully developed and implemented for Head and Neck cancer. This development along with more accurate registration algorithms can aid physicians in the efforts to interpret the multitude of imaging information available in radiotherapy today. This project was supported by a grant by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-T-388: Evaluation of Electronic Brachytherapy Dose Distributions in Tissue Equivalent Materials

Purpose: To study the measured and calculated dose distributions for electronic brachytherapy (EBT) in various tissue equivalent homogenous materials. Methods: Calculated dose distributions in water were generated using published TG-43 parameters in Varian BrachyVision software for a 50 kVp, 50 cm Xoft source. Dose distributions were measured within a 3D-scanning tank using dosimeters including: PTW 0.125 cc, pin-point, and parallel-plate ion chambers, Sun Nuclear “Edge” diode and Gafchromic EBT3 film. Multi-channel film dosimetry was used in film analysis. EBT3 film curves were calibrated via radial dose comparison to both independently measured and published data. The resulting film calibration was utilized to measure dose distributions created by titanium filtered source utilized in clinical brachytherapy applications. Data was collected within homogenous PMMA, vinyl, polystyrene, paraffin, and water-equivalent plastic phantoms. Results: Ion-chamber data was corrected to effective points of measurement and normalized prior to comparison between calculated and measured dose distributions. Measurements made in water and water equivalent materials compared well with results from treatment planning software. The maximum percent differences (relative to water) observed between 1 cm and 3.5 cm depth from source for each of the phantom materials are as follows: PMMA 35%, polystyrene 41%, plastic-water 23%, vinyl 115%, and paraffin 46%. Conclusion: The increased probability of photoelectric interactions occurring within the patient during electronic brachytherapy will emphasize the radiological differences between varying human tissues in dose deposition. These differences can Result in clinically significant dose perturbations and it is therefore recommended to move to a model based dose calculation, as outlined in TG-186, to improve the dosimetric accuracy of low energy EBT.

60 APPLIED LIFE SCIENCES↗

NSFnets (Navier-Stokes flow nets): Physics-informed neural networks for the incompressible Navier-Stokes equations

In the last 50 years there has been a tremendous progress in solving numerically the Navier-Stokes equations using finite differences, finite elements, spectral, and even meshless methods. Yet, in many real cases, we still cannot incorporate seamlessly (multi-fidelity) data into existing algorithms, and for industrial-complexity applications the mesh generation is time consuming and still an art. Moreover, solving ill-posed problems (e.g., lacking boundary conditions) or inverse problems is often prohibitively expensive and requires different formulations and new computer codes. Here, we employ physics-informed neural networks (PINNs), encoding the governing equations directly into the deep neural network via automatic differentiation, to overcome some of the aforementioned limitations for simulating incompressible laminar and turbulent flows. We develop the Navier-Stokes flow nets (NSFnets) by considering two different mathematical formulations of the Navier-Stokes equations: the velocity-pressure (VP) formulation and the vorticity-velocity (VV) formulation. Since this is a new approach, we first select some standard benchmark problems to assess the accuracy, convergence rate, computational cost and flexibility of NSFnets; analytical solutions and direct numerical simulation (DNS) databases provide proper initial and boundary conditions for the NSFnet simulations. The spatial and temporal coordinates are the inputs of the NSFnets, while the instantaneous velocity and pressure fields are the outputs for the VP-NSFnet, and the instantaneous velocity and vorticity fields are the outputs for the VV-NSFnet. This is unsupervised learning and, hence, no labeled data are required beyond boundary and initial conditions and the fluid properties. The residuals of the VP or VV governing equations, together with the initial and boundary conditions, are embedded into the loss function of the NSFnets. No data is provided for the pressure to the VP-NSFnet, which is a hidden state and is obtained via the incompressibility constraint without extra computational cost. Unlike the traditional numerical methods, NSFnets inherit the properties of neural networks (NNs), hence the total error is composed of the approximation, the optimization, and the generalization errors. Here, we empirically attempt to quantify these errors by varying the sampling (“residual”) points, the iterative solvers, and the size of the NN architecture. For the laminar flow solutions, we show that both the VP and the VV formulations are comparable in accuracy but their best performance corresponds to different NN architectures. The initial convergence rate is fast but the error eventually saturates to a plateau due to the dominance of the optimization error. For the turbulent channel flow, we show that NSFnets can sustain turbulence at , but due to expensive training we only consider part of the channel domain and enforce velocity boundary conditions on the subdomain boundaries provided by the DNS data base. We also perform a systematic study on the weights used in the loss function for balancing the data and physics components, and investigate a new way of computing the weights dynamically to accelerate training and enhance accuracy. In the last part, we demonstrate how NSFnets should be used in practice, namely for ill-posed problems with incomplete or noisy boundary conditions as well as for inverse problems. We obtain reasonably accurate solutions for such cases as well without the need to change the NSFnets and at the same computational cost as in the forward well-posed problems. As a result, we also present a simple example of transfer learning that will aid in accelerating the training of NSFnets for different parameter settings.

97 MATHEMATICS AND COMPUTING↗

A method for evaluating image quality of monochrome and color displays based on luminance by use of a commercially available color digital camera

Purpose: The aim of this study is to propose a method for the quantitative evaluation of image quality of both monochrome and color liquid-crystal displays (LCDs) using a commercially available color digital camera. Methods: The intensities of the unprocessed red (R), green (G), and blue (B) signals of a camera vary depending on the spectral sensitivity of the image sensor used in the camera. For consistent evaluation of image quality for both monochrome and color LCDs, the unprocessed RGB signals of the camera were converted into gray scale signals that corresponded to the luminance of the LCD. Gray scale signals for the monochrome LCD were evaluated by using only the green channel signals of the camera. For the color LCD, the RGB signals of the camera were converted into gray scale signals by employing weighting factors (WFs) for each RGB channel. A line image displayed on the color LCD was simulated on the monochrome LCD by using a software application for subpixel driving in order to verify the WF-based conversion method. Furthermore, the results obtained by different types of commercially available color cameras and a photometric camera were compared to examine the consistency of the authors’ method. Finally, image quality for both the monochrome and color LCDs was assessed by measuring modulation transfer functions (MTFs) and Wiener spectra (WS). Results: The authors’ results demonstrated that the proposed method for calibrating the spectral sensitivity of the camera resulted in a consistent and reliable evaluation of the luminance of monochrome and color LCDs. The MTFs and WS showed different characteristics for the two LCD types owing to difference in the subpixel structure. The MTF in the vertical direction of the color LCD was superior to that of the monochrome LCD, although the WS in the vertical direction of the color LCD was inferior to that of the monochrome LCD as a result of luminance fluctuations in RGB subpixels. Conclusions: The authors’ method based on the use of a commercially available color camera is useful to evaluate and understand the display performances of both monochrome and color LCDs in radiology departments.

60 APPLIED LIFE SCIENCES↗

Investigation of the OECD/NEA PWR MOX/UO{sub 2} core transient benchmark using a coupled whole core pin-by-pin route in WIMS

This paper investigates the new CAMELOT coupling route developed in WIMS, which uses prepared tabulated cross-sections combined with the flux solver MERLIN module and the integrated sub-channel thermal hydraulics solver ARTHUR module to solve for the coupled core state. This coupling route is applied to the OECD/NEA pressurized water reactor (PWR) core transient benchmark exercise, involving 3-D neutronics and thermal-hydraulics analysis of a full-sized PWR core featuring MOX fuel at various core states, as well as simulating a control rod ejection transient. Analysis of the results for each part of the benchmark demonstrate that the high-resolution pin-by-pin analysis used in WIMS closely matches the other participants in the benchmark, with differences of between 20-200 pcm for k-effective, 1-2.5% RMS difference for assembly-averaged powers, 2-8% difference in rod worth calculations, < 200 ppm for calculations of critical boron concentration, zero difference in delayed neutron fraction calculation and a very close match for power response to the rod ejection transient. This is the first application of the WIMS-CAMELOT approach for the transient analysis of a full-sized reactor and as such further improvements such as reducing computational cost through parallelization, optimisation and memory reduction, are currently in active development. This paper demonstrates the accuracy and flexibility of the CAMELOT coupling route, providing a straightforward and consistent user image that can be easily used for a variety of modelling problems involving coupled neutronics and thermal-hydraulics. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-366: Clinical Implementation of MR-Guided Vaginal Cylinder Brachytherapy

Purpose: To evaluate the accuracy of MR-based vaginal brachytherapy source localization using an in-house MR-visible marker versus the alignment of an applicator model to MR images. Methods: Three consecutive patients undergoing vaginal HDR brachytherapy with a plastic cylinder were scanned with both CT and MRI (including T1- and T2- weighted images). An MR-visible source localization marker, consisting of a sealed thin catheter filled with either water (for T2 contrast) or Gd-doped water (for T1 contrast), was assembled shortly before scanning. Clinically, the applicator channel was digitized on CT with an x-ray marker. To evaluate the efficacy of MR-based applicator reconstruction, each MR image volume was aligned locally to the CT images based on the region containing the cylinder. Applicator digitization was performed on the MR images using (1) the MR visible marker and (2) alignment of an applicator surface model from Varian's Brachytherapy Planning software to the MRI images. Resulting source positions were compared with the original CT digitization. Results: Although the source path was visualized by the MR marker, the applicator tip proved difficult to identify due to challenges in achieving a watertight seal. This resulted in observed displacements of the catheter tip, at times >1cm. Deviations between the central source positions identified via aligning the applicator surface model to MR and using the xray marker on CT ranged from 0.07 – 0.19 cm and 0.07 – 0.20 cm on T1- weighted and T2-weighted images, respectively. Conclusion: Based on the current study, aligning the applicator model to MRI provides a practical, current approach to perform MR-based brachytherapy planning. Further study is needed to produce catheters with reliably and reproducibly identifiable tips. Attempts are being made to improve catheter seals, as well as to increase the viscosity of the contrast material to decrease fluid mobility inside the catheter.

60 APPLIED LIFE SCIENCES↗

Full 3D Kinetic Modeling and Quantification of Positive Streamer Evolution in an Azimuthally Swept Pin-to-Plane Wedge Geometry

Cathode-directed streamer evolution in near atmospheric air is modeled in 3D pin-to-plane geometries using a 3D kinetic Particle-In-Cell (PIC) code that simulates particle-particle collisions via the Direct Simulation Monte Carlo (DSMC) method. Due to the computational challenges associated with a complete 360° volumetric domain, a practical alternative was achieved using a wedge domain and a range of azimuthal angles was explored (5°, 15°, 30°, and 45°) to study possible effects on the streamer growth and propagation due to the finite wedge angle. A DC voltage of 6 kV is administered to a hemispherical anode of radius 100 μm, with a planar cathode held at ground potential, generating an over-volted state with an electric field of 4 MV/m across a 1500 μm gap. The domain is seeded with an initial ion and electron density of 10 18 m -3 at 1 eV temperature confined to a spherical region of radius 100 μm centered at the tip of the anode. The air chemistry model [1] includes standard Townsend breakdown mechanisms (electron-neutral elastic, excitation, ionization, attachment, and detachment collision chemistry and secondary electron emission) as well as streamer mechanisms (photoionization and ion-neutral collisions) via tracking excited state neutrals which can then either quench via collisions or spontaneously emit a photon based on specific Einstein-A coefficients [2, 3]. In this work, positive streamer dynamics are formally quantified for each wedge angle in terms of electron velocity and density as temporal functions of coordinates r, Φ, and z. Applying a random plasma seed for each simulation, particles of interest are tracked with near femtosecond temporal resolution out to 1.4 ns and spatially binned. This process is repeated six times and results are averaged. Prior 2D studies have shown that the reduced electric field, E/n, can significantly impact streamer evolution [4]. We extend the analysis to 3D wedge geometries, to limit computational costs, and examine the wedge angle’s effect on streamer branching, propagation, and velocity. Results indicate that the smallest wedge angle that produced an acceptably converged solution is 30°. The potential effects that a mesh, when under-resolved with respect to the Debye length, can impart on streamer dynamics and numerical heating were not investigated, and we explicitly state here that the smallest cell size was approximately 10 times the minimum λ D in the streamer channel at late times. This constraint on cell size was the result of computational limitations on total mesh count.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗