Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Tail Dependence as a Measure of Teleconnected Warm and Cold Extremes of North American Wintertime Temperatures

Current models for spatial extremes are concerned with the joint upper (or lower) tail of the distribution at two or more locations. Such models cannot account for teleconnection patterns of 2-m surface air temperature ( T 2m ) in North America, where very low temperatures in the contiguous United States may coincide with very high temperatures in Alaska in the wintertime. This dependence between warm and cold extremes motivates the need for a model with opposite-tail dependence in spatial extremes. This work develops a statistical modeling framework that has flexible behavior in all four pairings of high and low extremes at pairs of locations. In particular, we use a mixture of rotations of common Archimedean copulas to capture various combinations of four-corner tail dependence. We study teleconnected T 2m extremes using ERA5 of daily average 2-m temperature during the boreal winter. Further, the estimated mixture model quantifies the strength of opposite-tail dependence between warm temperatures in Alaska and cold temperatures in the midlatitudes of North America, as well as the reverse pattern. These dependence patterns are shown to correspond to blocked and zonal patterns of midtropospheric flow. This analysis extends the classical notion of correlation-based teleconnections to considering dependence in higher quantiles.

54 ENVIRONMENTAL SCIENCES↗

X-Band Radar and Surface-Based Observations of Cold-Season Precipitation in Western Colorado’s Complex Terrain

Abstract Hydrologic processes associated with intermountain cold-season precipitation in the Upper Colorado River basin have important impacts on avalanche forecasting and water resource management. However, traditional weather radar networks struggle with observations in this complex terrain. Data collected during the Study of Precipitation, the Lower Atmosphere, and the Surface for Hydrometeorology (SPLASH) and its sister campaign, Surface Atmosphere Integrated Field Laboratory (SAIL) in the East River watershed of western Colorado, are used to examine a multistorm period from 23 December 2021 to 1 January 2022 that contributed 35% of the total winter precipitation in this watershed. Dual-polarization X-band radar and disdrometer measurements show ∼30-mm differences in precipitation amount at two sites in proximity over four distinct storm events within the period. Wind patterns, synoptic forcings, microphysical characteristics of precipitation, and surface meteorology are analyzed to explain the observed spatial variability of cold-season precipitation in complex mountainous terrain. Analysis shows that differences over time within this event are mainly accounted for by synoptic forcings, such as frontal passages; differences between sites are accounted for by the impact of variations in local wind patterns on precipitation microphysics. Patterns of surface precipitation intensity are compared and found to be correlated with X-band radar signatures; a relationship between a strong dendritic growth stage and intense low-density surface precipitation is reinforced by this study. This relationship demonstrates the importance of particle growth mechanisms on surface snowfall patterns in high-altitude complex terrain, underscoring the importance of realistic microphysical parameterizations. Significance Statement The amount and density of snowpack from western Colorado winter storms have significant impacts on water resources in the Upper Colorado River basin. Snowpack characteristics are affected by small-scale differences in how snow forms in the atmosphere. These differences are hard to study in the complex terrain of the Rockies, but data from the SPLASH and SAIL field campaigns allows us to investigate how snow crystal formation and mountain-driven wind patterns affect snow near the surface. Our study finds that snow crystal growth varies over small space and time scales and is likely controlled by the terrain beneath a given location and resultant local wind patterns. These results imply that predicting snowpack in the Rockies requires properly representing local wind patterns and crystal growth processes in models.

Heflin, Stella↗

Data from: "Moisture rivals temperature in limiting photosynthesis by trees establishing beyond their cold-edge range limit under ambient and warmed conditions"

This archive contains data files that were used to draw conclusions in “Moisture rivals temperature in limiting photosynthesis by trees establishing beyond their cold-edge range limit under ambient and warmed conditions”, by Moyes et al., 2015. All field research was completed in common garden plots set up as part of the Alpine Treeline Warming Experiment (ATWE) on Niwot Ridge, Colorado, USA.There are two main data file formats in this archive: comma-separated values (.csv), and Microsoft Excel (.xls and .xlsx). .xlsx files can be read using Microsoft Excel and Google Sheets, and .csv files can be read using any simple text editor program, such as TextEdit (Mac) and Notepad (Windows). This .pdf data user’s guide can be read using Adobe Acrobat Reader, or any other compatible software. Seedling photographs and their corresponding leaf area-processed images are available in .jpg/.JPG image format, and can be opened using Preview (Mac) and Photos (Windows). To provide additional spatial context, two types of geospatial files are also published in this data package: ESRI shapefiles (.shp) and .kml files. Shapefiles are compatible with any GIS software able to read the file type (such as QGIS or ESRI’s ArcGIS suite), and .kml files can be opened with Google Earth or Google Maps. Figures 3 and 4 in the publication contain data from Moyes et al. 2013. This publication is cited in the References section in this archive, and data files can be accessed via the Alpine Treeline Warming Experiment project portal on ESS-DIVE. ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Climate change is altering plant species distributions globally, and warming is expected to promote uphill shifts in mountain trees. However, at many cold-edge range limits, such as alpine treelines in the western United States, tree establishment may be colimited by low temperature and low moisture, making recruitment patterns with warming difficult to predict.- We measured response functions linking carbon (C) assimilation and temperature- and moisture-related microclimatic factors for limber pine (Pinus flexilis) seedlings growing in a heating × watering experiment within and above the alpine treeline. We then extrapolated these response functions using observed microclimate conditions to estimate the net effects of warming and associated soil drying on C assimilation across an entire growing season.- Moisture and temperature limitations were each estimated to reduce potential growing season C gain from a theoretical upper limit by 15–30% (c. 50% combined). Warming above current treeline conditions provided relatively little benefit to modeled net assimilation, whereas assimilation was sensitive to either wetter or drier conditions.- Summer precipitation may be at least as important as temperature in constraining C gain by establishing subalpine trees at and above current alpine treelines as seasonally dry subalpine and alpine ecosystems continue to warm.

54 ENVIRONMENTAL SCIENCES↗

Effects of Cold Temperature and Main Compressor Intercooling on Recuperator and Recompression Cycle Performance

<span>This study investigates the effects of cold supercritical CO2 (sCO2) temperatures, compressor inlet pressures, and main compressor intercooling on the efficiency and specific power of recompression sCO2 cycles. Reducing the cold sCO2 temperature increases the compressor inlet density, thus reducing required compression power and increasing cycle thermal efficiency. &nbsp;Similarly, main compressor intercooling improves the specific power of a recompression cycle, reducing sCO2 mass flow, cycle size and cost for a given power output, though it is also shown to lead to an internal pinch point in the low temperature recuperator. Strategies for remediation of internal pinch points for recuperators as well as for the main CO2 cooler and the flue gas cooler are discussed, and apply to recompression cycles for all sCO2 applications.&nbsp; Upfront consideration of these remediation strategies is essential to determine attainable sCO2 cycle operating conditions and component sizing requirements.</span>

Weiland, Nathan↗

MAGNETIC FLUX EXPULSION IN SUPERCONDUCTING RADIO-FREQUENCY NIOBIUM CAVITIES MADE FROM COLD WORKED NIOBIUM

Trapped residual magnetic field during the cool down of superconducting radio frequency (SRF) cavities is one of the primary sources of RF residual losses leading to lower quality factor. Historically, SRF cavities have been fabricated from high purity fine grain niobium with grain size ~50 to 100 µm as well as large grain with grain size of the order of few centimeters. Non-uniform recrystallization of fine-grain Nb cavities after the post fabrication heat treatment leads to higher flux trapping during the cool down, and hence the lower quality factor. We fabricated two 1.3 GHz single cell cavities from cold-worked niobium from different vendors and processed along with cavities made from SRF grade Nb. The flux expulsion and flux trapping sensitivity were measured after successive heat treatments in the range 800 to 1000°C. The flux expulsion from cold-worked fine-grain Nb cavities improves after 800°C/3h heat treatments and it becomes similar to that of standard fine-grain Nb cavities when the heat treatment temperature is higher than 900°C.

Khanal, B. D.↗

Dynamical crossover between the infinite-volume and empty-lattice limits of ultra-cold fermions in 1D optical lattices

Unlike typical condensed-matter systems, ultra-cold atoms loaded into optical lattices allow separate control of both the particle number and system size. As a consequence, there are two distinct "thermodynamic” limits that can be defined for these systems: i) ’’infinite-volume limit” at constant finite density, and ii) "empty-lattice limit” at constant particle number. To probe the difference between these two limits and their crossover, we consider a partially occupied lattice and study the transport into the unoccupied region of non-interacting fermions and fermions interacting at the mean-field level. In the infinite-volume limit, a finite steady-state current emerges. On the other hand, in the empty-lattice limit there is no finite steady-state current. By changing the initial filling, we find a smooth crossover between the two limits. Our predictions may be verified using available experimental tools and demonstrate a fundamental difference between isolated small systems such as ultra-cold atoms and conventional condensed-matter systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

New Analogies Between Extreme QCD and Cold Atoms

Plan of this talk: 1. “Hard probes” in cold atoms - Use of energetic atoms to locally probe strongly-interacting atomic gases; 2. "Quark-hadron continuity" in cold atoms - Smooth crossover from atoms to trimers in 3-component Fermi gases.

Atomic & Molecular Physics(74)↗

2012 Radiological Monitoring Results Associated with the Advanced Test Reactor Complex Cold Waste Pond

This report summarizes radiological monitoring performed of the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (#LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

99 GENERAL AND MISCELLANEOUS↗

Development and Implementation of 3-D, High Speed Capacitance Tomography for Imaging Large-Scale, Cold-Flow Circulating Fluidized Bed

A detailed understanding of multiphase flow behavior inside a Circulating Fluidized Bed (CFB) requires a 3-D technique capable of visualizing the flow field in real-time. Electrical Capacitance Volume Tomography (ECVT) is a newly developed technique that can provide such measurements. The attractiveness of the technique is in its low profile sensors, fast imaging speed and scalability to different section sizes, low operating cost, and safety. Moreover, the flexibility of ECVT sensors enable them to be designed around virtually any geometry, rendering them suitable to be used for measurement of solid flows in exit regions of the CFB. Tech4Imaging LLC has worked under contract with the U.S. Department of Energy's National Energy Technology Laboratory (DOE NETL) to develop an ECVT system for cold flow visualization and install it on a 12 inch ID circulating fluidized bed. The objective of this project was to help advance multi-phase flow science through implementation of an ECVT system on a cold flow model at DOE NETL. This project has responded to multi-phase community and industry needs of developing a tool that can be used to develop flow models, validate computational fluid dynamics simulations, provide detailed real-time feedback of process variables, and provide a comprehensive understating of multi-phase flow behavior. In this project, a complete ECVT system was successfully developed after considering different potential electronics and sensor designs. The system was tested at various flow conditions and with different materials, yielding real-time images of flow interaction in a gas-solid flow system. The system was installed on a 12 inch ID CFB of the US Department of Energy, Morgantown Labs. Technical and economic assessment of Scale-up and Commercialization of ECVT was also conducted. Experiments conducted with larger sensors in conditions similar to industrial settings are very promising. ECVT has also the potential to be developed for imaging multi-phase flow systems in high temperature and high pressure conditions, typical in many industrial applications.

42 ENGINEERING↗

Assessing Foundation Insulation Strategies for the 2012 International Energy Conservation Code in Cold Climate New Home Construction

Even though the International Energy Conservation Code 2012 (International Code Council 2012) is a model code now available for adoption by individual states, only two cold-climate states have adopted it as their new home energy code. Understanding the resistance to adoption is important in assisting more states to accept the code and engage in deep energy strategies nationwide. This three-part assessment by the NorthernSTAR Building America Partnership was focused on foundation insulation R-values for cold climates and the design, construction, and performance implications. In Section 1, a literature review and attendance at stakeholder meetings held in Minnesota were used to assess general stakeholder interest and concerns about proposed code changes. Section 2 includes drawings of robust foundation insulation systems that were presented at one Minnesota stakeholder meeting to address critical issues and concerns for adopting best practice strategies. In Section 3, a sampling of builders participated in a telephone interview to gain baseline knowledge on insulation systems used to meet the current energy code and how the same builders intend to meet the new proposed code. In general, most builders expressed interest in being able to deliver greater energy efficiency to their customers. Concerns were voiced, however, about the costs compared to the energy savings, constructability, and durability risk resulting from increased foundation insulation R-values. When solutions for building robust foundation wall systems were presented to stakeholders, they did express interest in learning the details of the strategies. There was, however, continued interest in proof of cost, payback, and hygrothermal performance. Builders who participated in the interview were more confident in being able to meet the new requirements. This might have been a result of these respondents already using more advanced techniques for foundation insulation. This insight gives Building America an opportunity to engage the industry with existing research and practice measures that can address constructability and durability concerns at the proposed code levels. It also indicates that builders are interested in more specific information on cost, energy savings, and overall hygrothermal performance. Filling these voids could yield the supportive data needed to enhance building industry confidence and engage more states in the adoption of 2012 International Energy Conservation Code for new homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Airtightness Results of Roof-Only Air Sealing Strategies on 1-1/2 Story Homes in Cold Climates

In this second study on solutions to ice dams in 1-1/2 story homes, five test homes located in both cold and very cold climates were analyzed for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. The reason for choosing this house type was they are very common in our area and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR Building America industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled us to compare air tightness data from over 220 homes using similar air seal methods.

1 1/2 STORY BUNGALOW↗

High-Current Cold Cathode Employing Diamond and Related Materials

The essence of this project was for diamond films to be deposited on cold cathodes to improve their emission properties. Films with varying morphology, composition, and size of the crystals were deposited and the emission properties of the cathodes that utilize such films were studied. The prototype cathodes fabricated by the methods developed during Phase I were tested and evaluated in an actual high-power RF device during Phase II. These high-power tests used the novel active RF pulse compression system and the X-band magnicon test facility at US Naval Research Laboratory. In earlier tests, plasma switches were employed, while tests under this project utilized electron-beam switching. The intense electron beams required in the switches were supplied from cold cathodes embodying diamond films with varying morphology, including uncoated molybdenum cathodes in the preliminary tests. Tests with uncoated molybdenum cathodes produced compressed X-band RF pulses with a peak power of 91 MW, and a maximum power gain of 16.5:1. Tests were also carried out with switches employing diamond coated cathodes. The pulse compressor was based on use of switches employing electron beam triggering to effect mode conversion. In experimental tests, the compressor produced 165 MW in a ~ 20 ns pulse at ~18× power gain and ~ 140 MW at ~ 16× power gain in a 16 ns pulse with a ~ 7 ns flat-top. In these tests, molybdenum blade cathodes with thin diamond coatings demonstrated good reproducible emission uniformity with a 100 kV, 100 ns high voltage pulse. The new compressor does not have the limitations of earlier types of active pulse compressors and can operate at significantly higher electric fields without breakdown.

36 MATERIALS SCIENCE↗

2014 Radiological Monitoring Results Associated with the Advanced Test Reactor Complex Cold Waste Pond

This report summarizes radiological monitoring performed of the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (#LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cold Mass Issues in the MICE Coupling Magnet

I have identified two potential issues in the design of the attachments to the MICE coupling magnet cold mass. One of these attachment issues may extend into the cold mass. Both issues came to light during the analysis of what happened to the spectrometer solenoids. We must not make the same mistakes that were made on the spectrometer solenoids. The two questions that result from the identified issues are; 1) Are the superconducting low temperature superconducting leads between the coupling coil and the lower end of the high temperature superconducting (LTS) leads robust enough not quench and burn out? In the spectrometer solenoid one part of the LTS lead was not robust enough to prevent quenching and a burn out of the LTS lead and ; 2) Will there be problems with the quench protection resistors and diodes when the magnet quenches as a result of an HTS lead burning out or a disconnect of the magnet from its power supply? The second question is very important because the coupling coil has a large stored energy and inductance. As result, when current flows through the diodes and the resistors, both can be over heated. We observed resistor overheating in spectrometer magnet 2. This heating probably happened when the HTS lead the LTS lead burned out during the tests of magnet 2A and 2B respectively. (See MICE Note 324.) The answer to the first question is simple and straightforward. This is the issue that is primarily dealt with in MICE Note 324. If the resistance across the coil sub-divisions is high enough, the whole magnet will turn normal through quench-back. Making the resistance across a coil sub-division high enough is not simple.

43 PARTICLE ACCELERATORS↗

Assessing Foundation Insulation Strategies for the 2012 International Energy Conservation Code in Cold Climate New Home Construction

While the International Energy Conservation Code 2012 (IECC 2012) has been adopted at a national level, only two cold climate states have adopted it as their new home energy code. Understanding the resistance to adoption is important in assisting more states accept the code and engage deep energy strategies nationwide. This three-part assessment by the NorthernSTAR Building America Partnership was focused on foundation insulation R-values for cold climates and the design, construction, and performance implications. In Part 1 a literature review and attendance at stakeholder meetings held in Minnesota were used to assess general stakeholder interest and concerns regarding proposed code changes. Part 2 includes drawings of robust foundation insulation systems that were presented at one Minnesota stakeholder meeting to address critical issues and concerns for adopting best practice strategies. In Part 3 a sampling of builders participated in a telephone interview to gain baseline knowledge on insulation systems used to meet the current energy code and how the same builders propose to meet the new proposed code.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Airtightness Results of Roof-Only Air Sealing Strategies on 1 ½-Story Homes in Cold Climates

In this second study on solutions to ice dams in 1-1/2 story homes, the NorthernSTAR Building America Partnership team analyzed five test homes located in both cold and very cold climates for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. These homes were chosen for testing as they are common in Minnesota and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled the team to compare air tightness data from over 220 homes using similar air seal methods.

1 1/2 story bungalow↗

Testing of the Defense Waste Processing Facility Cold Chemical Dissolution Method in Sludge Batch 9 Qualification

For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) tests the applicability of the digestion methods used by the DWPF Laboratory for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) Receipt samples and SRAT Product process control samples. DWPF SRAT samples are typically dissolved using a method referred to as the DWPF Cold Chemical or Cold Chem Method (CC), (see DWPF Procedure SW4- 15.201). Testing indicates that the CC method produced mixed results. The CC method did not result in complete dissolution of either the SRAT Receipt or SRAT Product with some fine, dark solids remaining. However, elemental analyses did not reveal extreme biases for the major elements in the sludge when compared with analyses obtained following dissolution by hot aqua regia (AR) or sodium peroxide fusion (PF) methods. The CC elemental analyses agreed with the AR and PF methods well enough that it should be adequate for routine process control analyses in the DWPF after much more extensive side-by-side tests of the CC method and the PF method are performed on the first 10 SRAT cycles of the Sludge Batch 9 (SB9) campaign. The DWPF Laboratory should continue with their plans for further tests of the CC method during these 10 SRAT cycles.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Aerosol effects on the anvil characteristics, cold pool forcing and stratiform-convective precipitation partitioning and latent heating of mesoscale convective systems

The overarching science goal of this project has been to assess the impacts of aerosols on mesoscale convective systems (MCSs). More specifically we have investigated the impacts of (a) aerosol types, (b) aerosol concentrations, and (c) the vertical and horizontal location of aerosols on the (1) anvil cloud characteristics and feedbacks; (2) total precipitation and the partitioning between convective and stratiform precipitation; (3) the vertical heating structure; (4) hydrometeor size distributions; and (5) the strength and intensity of the cold pools and updrafts. These have been achieved both through observational analyses and high-resolution cloud-resolving model simulations of three MCSs that were observed during the MC3E field campaign (25 April, 20 May and 23 May 2011). The primary findings of these research are the following: Condensation and deposition are the primary contributors to MCS latent warming, when compared to riming and nucleation processes. In terms of MCS latent cooling, sublimation, melting, and evaporation all play significant roles. Throughout the MCS lifecycle, convective regions demonstrate an approximately linear decrease in the magnitudes of latent heating rates, while latent heating within stratiform regions is associated with transitions between MCS flow regimes including the rear inflow jet. Such information regarding the temporal evolution of latent heating within convective and stratiform MCS regions could be useful in developing parameterizations representing convective organization. Increasing aerosol concentration from a clean continental to a highly polluted state produces an increase in the riming rates of cloud water, which results in less lofted cloud water in polluted environments. Aerosol-induced trends in the cloud mixing ratio profiles are, however, nonmonotonic in the mixed phase region, such that a moderate increase in aerosol concentration produces the greatest reduction in cloud water. Less lofted cloud water due to enhanced riming rates leads to reduced anvil ice mixing ratios but to greater numbers of small ice crystals within the anvil. In spite of reduced anvil ice mixing ratio, the anvil clouds exhibit greater areal coverage, increased albedo, reduced cloud top cooling, and reduced net radiative flux, which produces an aerosol-induced warming (reduced cooling) effect in these MCSs. Lower-tropospheric aerosol particles largely influence the MCS precipitation response directly rearward of the leading cold pool boundary. However, further backward in the MCS, the relative impact of lower- versus mid-tropospheric aerosol particles is strongly dependent on the MCS structure and differences in the line-normal wind shear. Mid-tropospheric aerosol particles are able to activate new cloud droplets in the mid-tropospheric levels of convective updrafts and thereby enhance mixed-phase precipitation through increased cloud riming.

54 ENVIRONMENTAL SCIENCES↗