Search NASA⌕ Search

SEARCH · Search NASA

Results for “computational imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Patterns of Recurrence After Low-Dose-Rate Prostate Brachytherapy: A Population-Based Study of 2223 Consecutive Low- and Intermediate-Risk Patients

Objectives: This study examined patterns of recurrence after low–dose-rate prostate brachytherapy (LDR-PB), estimated local recurrence rate and compared that rate to the estimated local recurrence rate after radical prostatectomy (RP). Methods and Materials: A prospective database was maintained with clinical, dosimetric, and outcome data for all LDR-PB implantation procedures performed at our institution. From 1998 to 2008, 2223 patients with prostate cancer received LDR-PB without supplemental external beam radiation therapy. Patients who developed Phoenix-defined biochemical failure were reviewed for sites of relapse and investigations completed. Results: At a median follow-up of 5 years, 108 of 2223 patients (4.8%) developed biochemical relapse. In 1 additional patient, local relapse was found on transurethral prostate resection, but his prostate-specific antigen concentration was well short of triggering Phoenix-defined failure. Of the 109 patients with disease relapse, 18 of 2223 (0.8%) had a proven local recurrence, and 30 of 2223 (1.3%) had a proven distant recurrence. The remaining 61 of 2223 patients (2.7%) had unidentified sites of recurrence; of these, 57 patients (93%) had digital rectal examinations (DREs), 18 (30%) had post-treatment biopsies, 45 (74%) had bone scans, and 34 (56%) had computed tomography imaging of the abdomen and pelvis. If every biochemical failure were local, the local recurrence rate would be as high as 4.9%; however, by excluding those with proven distant failure and those with both a negative DRE and biopsy, we estimate that the local recurrence rate is 2.7% or less. Conclusions: In the context of limitations of the study design, our population-based analysis indicates that the local recurrence rate after LDR-PB is as low or lower than that after RP in our jurisdiction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mapping Patterns of Ipsilateral Supraclavicular Nodal Metastases in Breast Cancer: Rethinking the Clinical Target Volume for High-risk Patients

Purpose: To map the location of metastatic supraclavicular (SCV) lymph nodes (LNMs) in breast cancer patients with SCV node involvement and determine whether and where the radiation therapy clinical target volume (CTV) of this region could be modified in high-risk subsets. Methods and Materials: Fifty-five patients with metastatic SCV LNMs were eligible for geographic mapping and atlas coverage analysis. All LNMs and their epicenters were registered proportionally by referencing the surrounding landmarks onto simulation computed tomography images of a standard patient. CTVs based on selected SCV atlases, including the one by the Radiation Therapy Oncology Group (RTOG) were contoured. A modified SCV CTV was tried and shown to have better involved-node coverage and thus theoretically improved prophylaxis in this setting. Results: A total of 50 (91%) and 45 (81.8%) patients had LNMs in the medial and lateral SCV subregions, respectively. Also, 36 patients (65.5%) had LNMs located at the junction of the jugular-subclavian veins. All nodes were covered in only 25.5% to 41.8% of patients by different atlases. The RTOG atlas covered all nodes in 25.5% of patients. Stratified by the nodes in all the patients as a whole, 49.2% to 81.3% were covered, and the RTOG atlas covered 62.6%. The lateral and posterior borders were the most overlooked locations. Modification by extending the borders to natural anatomic barriers allowed the new CTV to cover all the nodes in 81.8% of patients and encompass 96.1% of all the nodes. Conclusions: According to the distribution of SCV LNMs, the extent of existing atlases might not be adequate for potential metastatic sites in certain groups of patients. The extension of the lateral and posterior CTV borders in high-risk or recurrent patients might be a reasonable approach for increasing coverage. However, additional data in more homogeneous populations with localized disease are needed before routine application.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Focal Radiation Therapy Dose Escalation Improves Overall Survival in Locally Advanced Pancreatic Cancer Patients Receiving Induction Chemotherapy and Consolidative Chemoradiation

Purpose: To review outcomes of locally advanced pancreatic cancer (LAPC) patients treated with dose-escalated intensity modulated radiation therapy (IMRT) with curative intent. Methods and Materials: A total of 200 patients with LAPC were treated with induction chemotherapy followed by chemoradiation between 2006 and 2014. Of these, 47 (24%) having tumors >1 cm from the luminal organs were selected for dose-escalated IMRT (biologically effective dose [BED] >70 Gy) using a simultaneous integrated boost technique, inspiration breath hold, and computed tomographic image guidance. Fractionation was optimized for coverage of gross tumor and luminal organ sparing. A 2- to 5-mm margin around the gross tumor volume was treated using a simultaneous integrated boost with a microscopic dose. Overall survival (OS), recurrence-free survival (RFS), local-regional and distant RFS, and time to local-regional and distant recurrence, calculated from start of chemoradiation, were the outcomes of interest. Results: Median radiation dose was 50.4 Gy (BED = 59.47 Gy) with a concurrent capecitabine-based (86%) regimen. Patients who received BED >70 Gy had a superior OS (17.8 vs 15.0 months, P=.03), which was preserved throughout the follow-up period, with estimated OS rates at 2 years of 36% versus 19% and at 3 years of 31% versus 9% along with improved local-regional RFS (10.2 vs 6.2 months, P=.05) as compared with those receiving BED ≤70 Gy. Degree of gross tumor volume coverage did not seem to affect outcomes. No additional toxicity was observed in the high-dose group. Higher dose (BED) was the only predictor of improved OS on multivariate analysis. Conclusion: Radiation dose escalation during consolidative chemoradiation therapy after induction chemotherapy for LAPC patients improves OS and local-regional RFS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Limited Impact of Setup and Range Uncertainties, Breathing Motion, and Interplay Effects in Robustly Optimized Intensity Modulated Proton Therapy for Stage III Non-small Cell Lung Cancer

Purpose: To investigate the impact of setup and range uncertainties, breathing motion, and interplay effects using scanning pencil beams in robustly optimized intensity modulated proton therapy (IMPT) for stage III non-small cell lung cancer (NSCLC). Methods and Materials: Three-field IMPT plans were created using a minimax robust optimization technique for 10 NSCLC patients. The plans accounted for 5- or 7-mm setup errors with ±3% range uncertainties. The robustness of the IMPT nominal plans was evaluated considering (1) isotropic 5-mm setup errors with ±3% range uncertainties; (2) breathing motion; (3) interplay effects; and (4) a combination of items 1 and 2. The plans were calculated using 4-dimensional and average intensity projection computed tomography images. The target coverage (TC, volume receiving 95% of prescribed dose) and homogeneity index (D{sub 2} − D{sub 98}, where D{sub 2} and D{sub 98} are the least doses received by 2% and 98% of the volume) for the internal clinical target volume, and dose indexes for lung, esophagus, heart and spinal cord were compared with that of clinical volumetric modulated arc therapy plans. Results: The TC and homogeneity index for all plans were within clinical limits when considering the breathing motion and interplay effects independently. The setup and range uncertainties had a larger effect when considering their combined effect. The TC decreased to <98% (clinical threshold) in 3 of 10 patients for robust 5-mm evaluations. However, the TC remained >98% for robust 7-mm evaluations for all patients. The organ at risk dose parameters did not significantly vary between the respective robust 5-mm and robust 7-mm evaluations for the 4 error types. Compared with the volumetric modulated arc therapy plans, the IMPT plans showed better target homogeneity and mean lung and heart dose parameters reduced by about 40% and 60%, respectively. Conclusions: In robustly optimized IMPT for stage III NSCLC, the setup and range uncertainties, breathing motion, and interplay effects have limited impact on target coverage, dose homogeneity, and organ-at-risk dose parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Repeatability and Reproducibility of Radiomic Features: A Systematic Review

An ever-growing number of predictive models used to inform clinical decision making have included quantitative, computer-extracted imaging biomarkers, or “radiomic features.” Broadly generalizable validity of radiomics-assisted models may be impeded by concerns about reproducibility. We offer a qualitative synthesis of 41 studies that specifically investigated the repeatability and reproducibility of radiomic features, derived from a systematic review of published peer-reviewed literature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microstructural Characterization and Pore Structure Analysis of Nuclear Graphite

Graphite will be used as a structural and moderator material in next-generation nuclear reactors. While the overall nature of the production of nuclear graphite is well understood, the historic nuclear grades of graphite are no longer available. This paper reports the virgin microstructural characteristics of filler particles and macro-scale porosity in virgin nuclear graphite grades of interest to the Next Generation Nuclear Plant program. Optical microscopy was used to characterize filler particle size and shape as well as the arrangement of shrinkage cracks. Computer aided image analysis was applied to optical images to quantitatively determine the variation of pore structure, area, eccentricity, and orientation within and between grades. The overall porosity ranged between {approx}14% and 21%. A few large pores constitute the majority of the overall porosity. The distribution of pore area in all grades was roughly logarithmic in nature. The average pore was best fit by an ellipse with aspect ratio of {approx}2. An estimated 0.6-0.9% of observed porosity was attributed to shrinkage cracks in the filler particles. Finally, a preferred orientation of the porosity was observed in all grades.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Titanium porous-transport layers for PEM water electrolysis prepared by tape casting

While the porous-transport layer (PTL) is a key component in PEM electrolyzers, it is one of the most underexplored due to limited available structures. In this work, we present a novel PTL design for PEM water electrolyzers enabled by a cost-effective, scalable tape-casting technique. Here, a precise control of the PTL pore structure is achieved by incorporating poreformers of various sizes, and by varying the titanium and poreformer ratio. The structures are characterized with SEM and synchrotron X-ray computed tomography imaging techniques. Comprehensive electrochemical performance analysis demonstrates that higher titanium loading provides improved contact at the catalyst-layer/PTL interface but suffers from severe mass-transport losses due to gas bubbles. We solve this mass-transport problem by mixing in large poreformer beads that produce a highly porous structure with excellent gas removal properties yet still maintaining mechanical integrity. The PTL fabricated with 60:40 Ti:PMMA ratio and 60 μm PMMA bead size outperformed the standard commercial Ti powder-based PTL by 62 mV at 4 A/cm 2 .

25 ENERGY STORAGE↗

Insight into the deformation features and capacity loss mechanisms of lithium-ion pouch cells under spherical indentation conditions

Mechanical deformation under extreme conditions is one of the important reasons for the failure of lithium-ion batteries in automotive application. However, the deformation features and component failure of lithium-ion cells to external loading has never been a design consideration. Here, in this study, we conduct spherical indentation tests on a dozen of lithium-ion cells with different capacities under different control mode conditions to investigate their deformation features and capacity loss mechanisms. The experimental results show that, under mechanical deformation conditions, internal faults of cells occur in stages, and energy accumulation and sudden release are two key processes of cell's mechanical failure. The cells' state of charge is the main factor affecting their thermal runaway behaviors. In addition, a finite element model is developed to simulate the deformation features and the failure mechanism of key components of lithium-ion pouch cells; the 3D x-ray computed tomography is employed to demonstrate its internal configuration. With this model, the force-strain response, the deformation features as well as the size of the failure area of lithium-ion cells under spherical indentation conditions are accurately predicted. In 3D x-ray computed tomography images, unique mud cracks in cooper current collector are observed, and the influence mechanisms of the isolated fragments on the cell capacities are revealed. These results may provide useful information for the mechanical structure design of the components of lithium-ion pouch cells.

25 ENERGY STORAGE↗

Segmentation, statistical analysis, and modelling of the wall system in ceramic foams

Closed walls in otherwise open foam structures may have a great impact on macroscopic properties of the materials. In this paper, we present two algorithms for the segmentation of such closed walls from micro-computed tomography images of the foam structure. The techniques are compared on simulated data and applied to tomographic images of ceramic filters. This allows for a detailed statistical analysis of the normal directions and sizes of the walls. Finally, we explain how the information derived from the segmented wall system can be included in a stochastic microstructure model for the foam.

36 MATERIALS SCIENCE↗

Dosimetric Study and Verification of Total Body Irradiation Using Helical Tomotherapy and its Comparison to Extended SSD Technique

The American College of Radiology practice guideline for total body irradiation (TBI) requires a back-up treatment delivery system. This study investigates the development of helical tomotherapy (HT) for delivering TBI and compares it with conventional extended source-to-surface distance (X-SSD) technique. Four patients' head-to-thigh computed tomographic images were used in this study, with the target defined as the body volume without the left and right lungs. HT treatment plans with the standard TBI prescription (1.2 Gy/fx, 10 fractions) were generated and verified on phantoms. To compare HT plans with X-SSD treatment, the dose distribution of X-SSD technique was simulated using the Eclipse software. The average dose received by 90% of the target volume was 12.3 Gy (range, 12.2-12.4 Gy) for HT plans and 10.3 Gy (range, 10.08-10.58 Gy) for X-SSD plans (p < 0.001). The left and right lung median doses were 5.44 Gy and 5.40 Gy, respectively, for HT plans and 8.34 Gy and 8.95 Gy, respectively, for X-SSD treatment. The treatment planning time was comparable between the two methods. The beam delivery time of HT treatment was longer than X-SSD treatment. In conclusion, HT-based TBI plans have better dose coverage to the target and better dose sparing to the lungs compared with X-SSD technique, which applies dose compensators, lung blocks, and electron boosts. This study demonstrates that HT is possible for delivering TBI. Clinical validation of the feasibility of this approach would be of interest in the future.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Evaluation of a 3D Diode Array Dosimeter for Helical Tomotherapy Delivery QA

The Delta4 biplanar diode array dosimeter was validated for helical tomotherapy delivery QA. The basic detector characteristics were found to be satisfactory in terms of short-term reproducibility (0.1%), linearity (<0.1%), dose rate dependence (0.4%), and absolute calibration accuracy (0.4% in the center of the phantom compared with the independently calibrated diode). Relative calibration of the arrays was verified by comparison with film and by rotating the detector 180{sup o}. The dosimeter response to rotational irradiation changed by no more than 0.2% when one of the detector boards was replaced by the homogeneous phantom material. The daily output correction factor can be derived from a Delta4 measurement in a uniform cylindrical field. The {gamma}(3%, 3 mm) passing rate (absolute dose) was above 90% for all 9 evaluated clinical plans, and above 96% for all but one. The mean passing rate was 97 {+-} 2.7%. The plans varied in modulation factor, pitch, and calculation grid size. For best results, the phantom needs to be aligned carefully, preferably by megavoltage computed tomography imaging.

07 ISOTOPE AND RADIATION SOURCES↗

Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance

To compare the doses calculated using the BrainLAB pencil beam (PB) and Monte Carlo (MC) algorithms for tumors located in various sites including the lung and evaluate quality assurance procedures required for the verification of the accuracy of dose calculation. The dose-calculation accuracy of PB and MC was also assessed quantitatively with measurement using ionization chamber and Gafchromic films placed in solid water and heterogeneous phantoms. The dose was calculated using PB convolution and MC algorithms in the iPlan treatment planning system from BrainLAB. The dose calculation was performed on the patient's computed tomography images with lesions in various treatment sites including 5 lungs, 5 prostates, 4 brains, 2 head and necks, and 2 paraspinal tissues. A combination of conventional, conformal, and intensity-modulated radiation therapy plans was used in dose calculation. The leaf sequence from intensity-modulated radiation therapy plans or beam shapes from conformal plans and monitor units and other planning parameters calculated by the PB were identical for calculating dose with MC. Heterogeneity correction was considered in both PB and MC dose calculations. Dose-volume parameters such as V95 (volume covered by 95% of prescription dose), dose distributions, and gamma analysis were used to evaluate the calculated dose by PB and MC. The measured doses by ionization chamber and EBT GAFCHROMIC film in solid water and heterogeneous phantoms were used to quantitatively asses the accuracy of dose calculated by PB and MC. The dose-volume histograms and dose distributions calculated by PB and MC in the brain, prostate, paraspinal, and head and neck were in good agreement with one another (within 5%) and provided acceptable planning target volume coverage. However, dose distributions of the patients with lung cancer had large discrepancies. For a plan optimized with PB, the dose coverage was shown as clinically acceptable, whereas in reality, the MC showed a systematic lack of dose coverage. The dose calculated by PB for lung tumors was overestimated by up to 40%. An interesting feature that was observed is that despite large discrepancies in dose-volume histogram coverage of the planning target volume between PB and MC, the point doses at the isocenter (center of the lesions) calculated by both algorithms were within 7% even for lung cases. The dose distributions measured with EBT GAFCHROMIC films in heterogeneous phantoms showed large discrepancies of nearly 15% lower than PB at interfaces between heterogeneous media, where these lower doses measured by the film were in agreement with those by MC. The doses (V95) calculated by MC and PB agreed within 5% for treatment sites with small tissue heterogeneities such as the prostate, brain, head and neck, and paraspinal tumors. Considerable discrepancies, up to 40%, were observed in the dose-volume coverage between MC and PB in lung tumors, which may affect clinical outcomes. The discrepancies between MC and PB increased for 15 MV compared with 6 MV indicating the importance of implementation of accurate clinical treatment planning such as MC. The comparison of point doses is not representative of the discrepancies in dose coverage and might be misleading in evaluating the accuracy of dose calculation between PB and MC. Thus, the clinical quality assurance procedures required to verify the accuracy of dose calculation using PB and MC need to consider measurements of 2- and 3-dimensional dose distributions rather than a single point measurement using heterogeneous phantoms instead of homogenous water-equivalent phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Implementation and evaluation of modified dynamic conformal arc (MDCA) technique for lung SBRT patients following RTOG protocols

To implement modified dynamic conformal arc (MDCA) technique and Radiation Therapy Oncology Group (RTOG) protocols in our clinic for stereotactic body radiation therapy (SBRT) treatment of patients with Stage I/II non–small cell lung cancer. Five patients with non–small cell lung cancer have been treated with SBRT. All the patients were immobilized using CIVCO Body Pro-Lok system and scanned using GE 4-slice computed tomography. The MDCA technique that was previously published was adopted as our planning technique, and RTOG protocols for the lung SBRT were followed. The patients were treated on Novalis Tx system with cone-beam computed tomography imaging guidance. All the patient plans passed the RTOG criteria. The conformal index ranges from 0.99 to 1.12 for the planning target volume, and the biological equivalent dose for the planning target volume is overall 100 Gy. Critical structures (lung, spinal cord, brachial plexus, skin, and chest wall) also meet RTOG protocols or published data. A 6-month follow-up of one of the patients shows good local disease control. We have successfully implemented the MDCA technique into our clinic for the lung SBRT program. It shows that the MDCA is useful and efficient for the lung SBRT planning, with the plan quality meeting the RTOG protocols.

61 RADIATION PROTECTION AND DOSIMETRY↗

The importance of prostate bed tilt during postprostatectomy intensity-modulated radiotherapy

Variations in rectal and bladder filling can create a tilt of the prostate bed, which generates the potential for a geographic miss during postprostatectomy radiotherapy. The aim of this study is to assess the effect that bladder and rectum filling has on planning target volume angle, to determine a method to assess prostate bed tilt leading to potential geographic miss, and to discuss possible implementation issues. The cone-beam computed tomography images (n = 377) of 40 patients who received postprostatectomy radiotherapy with intensity-modulated radiotherapy were reviewed. The amount of tilt in the prostate bed was defined as the angle change between 2 surgical clips, one in the upper prostate bed and another in the lower. A potential geographic miss was defined as movement of any clip of more than 1 cm in any direction or 0.5 cm posteriorly when aligned to bone anatomy. Variations in bladder and rectum size were correlated with the degree of prostate bed tilt, and the rate of potential geographic miss was determined. A possible clinical use of prostate bed tilt was then assessed for different imaging techniques. A tilt of more than 10° was seen in 20.2% of images, which resulted in a 57.9% geographic miss rate of the superior clip. When tilt remained within 10°, there was only a 9% rate of geographic miss. Potential geographic miss of the inferior surgical clip was rare, occurring in only 1.9% of all images reviewed. The most common occurrence when the prostate bed tilt increased by more than 10° was a smaller bladder and larger rectum (6.4% of all images). The most common occurrence when the prostate bed tilt decreased by more than 10° was a larger bladder and smaller rectum (1.3% of all images). Significant prostate bed tilt (>± 10°) occurred in more than 20% of images, creating a 58% rate of geographic miss. Greatest prostate bed tilt occurred when the bladder size increased or reduced by more than 2 cm or the superior rectum size increased by more than 1.5 cm or reduced by more than 1 cm from the planned size. Using prostate bed tilt could be an effective measurement for assessing potential geographic miss on orthogonal images if volumetric imaging is unavailable.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluations of secondary cancer risk in spine radiotherapy using 3DCRT, IMRT, and VMAT: A phantom study

This study evaluated the secondary cancer risk from volumetric-modulated arc therapy (VMAT) for spine radiotherapy compared with intensity-modulated radiotherapy (IMRT) and 3-dimensional conformal radiotherapy (3DCRT). Computed tomography images of an Radiological Physics Center spine anthropomorphic phantom were exported to a treatment planning system (Pinnacle{sup 3}, version 9.4). Radiation treatment plans for spine were prepared using VMAT (dual-arc), 7-field IMRT (beam angles: 110°, 130°, 150°, 180°, 210°, 230°, and 250°), and 4-field 3DCRT technique. The mean and maximum doses, dose-volume histograms, and volumes receiving more than 2 and 4 Gy to organs at risk (OARs) were calculated and compared. The lifetime risk for secondary cancers was estimated according to the National Cancer Registry Programme Report 116. VMAT delivered the lowest maximum dose to the esophagus (4.03 Gy), bone (8.11 Gy), heart (2.11 Gy), spinal cord (6.45 Gy), and whole lung (5.66 Gy) as compared with other techniques (IMRT and 3DCRT). The volumes of OAR (esophagus) receiving more than 4 Gy were 0% for VMAT, 27.06% for IMRT, and up to 32.35% for 3DCRT. The estimated risk for secondary cancer in the respective OAR is considerably lower in VMAT compared with other techniques. The results of maximum doses and volumes of OARs suggest that the risk of secondary cancer induction for the spine in VMAT is lower than IMRT and 3DCRT, whereas VMAT has the best target coverage compared with the other techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

Functional image-guided stereotactic body radiation therapy planning for patients with hepatocellular carcinoma

The aim of the current planning study is to evaluate the ability of gadoxetate disodium-enhanced magnetic resonance imaging (EOB-MRI)–guided stereotactic body radiation therapy (SBRT) planning by using intensity-modulated radiation therapy (IMRT) techniques in sparing the functional liver tissues during SBRT for hepatocellular carcinoma. In this study, 20 patients with hepatocellular carcinoma were enrolled. Functional liver tissues were defined according to quantitative liver-spleen contrast ratios ≥ 1.5 on a hepatobiliary phase scan. Functional images were fused with the planning computed tomography (CT) images; the following 2 SBRT plans were designed using a “step-and-shoot” static IMRT technique for each patient: (1) an anatomical SBRT plan optimization based on the total liver; and (2) a functional SBRT plan based on the functional liver. The total prescribed dose was 48 gray (Gy) in 4 fractions. Dosimetric parameters, including dose to 95% of the planning target volume (PTV D{sub 95%}), percentages of total and functional liver volumes, which received doses from 5 to 30 Gy (V5 to V30 and fV5 to fV30), and mean doses to total and functional liver (MLD and fMLD, respectively) of the 2 plans were compared. Compared with anatomical plans, functional image-guided SBRT plans reduced MLD (mean: plan A, 5.5 Gy; and plan F, 5.1 Gy; p < 0.0001) and fMLD (mean: plan A, 5.4 Gy; and plan F, 4.9 Gy; p < 0.0001), as well as V5 to V30 and fV5 to fV30. No differences were noted in PTV coverage and nonhepatic organs at risk (OARs) doses. In conclusion, EOB-MRI–guided SBRT planning using the IMRT technique may preserve functional liver tissues in patients with hepatocellular carcinoma (HCC).

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparative effects of sodium channel blockers in short term rat whole embryo culture

This study was undertaken to examine the effect on the rat embryonic heart of two experimental drugs (AZA and AZB) which are known to block the sodium channel Nav1.5, the hERG potassium channel and the L-type calcium channel. The sodium channel blockers bupivacaine, lidocaine, and the L-type calcium channel blocker nifedipine were used as reference substances. The experimental model was the gestational day (GD) 13 rat embryo cultured in vitro. In this model the embryonic heart activity can be directly observed, recorded and analyzed using computer assisted image analysis as it responds to the addition of test drugs. The effect on the heart was studied for a range of concentrations and for a duration up to 3 h. The results showed that AZA and AZB caused a concentration-dependent bradycardia of the embryonic heart and at high concentrations heart block. These effects were reversible on washout. In terms of potency to cause bradycardia the compounds were ranked AZB > bupivacaine > AZA > lidocaine > nifedipine. Comparison with results from previous studies with more specific ion channel blockers suggests that the primary effect of AZA and AZB was sodium channel blockage. The study shows that the short-term rat whole embryo culture (WEC) is a suitable system to detect substances hazardous to the embryonic heart. - Highlights: • Study of the effect of sodium channel blocking drugs on embryonic heart function • We used a modified method rat whole embryo culture with image analysis. • The drugs tested caused a concentration dependent bradycardia and heart block. • The effect of drugs acting on multiple ion channels is difficult to predict. • This method may be used to detect cardiotoxicity in prenatal development.

60 APPLIED LIFE SCIENCES↗

Three-Dimensional Pore Networks in Miocene Stevens Sandstone of California: Implications for CO 2 Geologic Storage

The Miocene Stevens Sandstone in the San Joaquin Basin of California is increasingly recognized as a promising candidate for CO 2 geological storage due to the enormous storage capacity, proven sealing, and existing infrastructure. In this study, computed microtomography imaging and pore network modeling were employed to investigate the influence of pore geometry and wettability on the CO 2 injectivity and residual trapping. Image analysis revealed that a significant fraction of the cement and matrix consists of microporous regions. The microporosity can substantially increase the overall pore space, yet its contribution to permeability remains modest, particularly in samples with low permeability. The intrinsic heterogeneity of turbidite reservoirs further complicates the reservoir properties among different layers. Two-phase flow simulations under varying wettability conditions (water-wet, weak water-wet, and neutral-wet) demonstrated that the CO 2 injection is predominantly controlled by macropores. CO 2 invades microporous regions only after these larger pores are filled. The presence of microporosity leads to a decrease in both initial and residual CO 2 saturations, with the magnitude of the reduction being influenced by wettability. Neutral-wet scenarios exhibit higher CO 2 mobility and thus lower residual trapping than water-wet scenarios. The results imply that heterogeneity in pore geometry and cement distribution across different layers can result in stratified CO 2 flow pathways, complicating efforts to predict injection performance. Overall, the Stevens Sandstone shows considerable promise for CO 2 geologic storage, but effective implementation will require detailed characterization of the pore structure as well as the integration of reactive fluid flow to account for potential mineral dissolution and fines migration.

fluids↗