Search NASA⌕ Search

SEARCH · Search NASA

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Measurement of low energy characteristic X-rays emitted present in U-10Mo HALEU alloy fuel

Advance high density monolithic alloy HALEU fuels have been scanned with a silicon drift detector scanning system to measure low-energy characteristic X-rays emitted by uranium daughters, as well as zirconium present as a foil diffusion barrier. Four peaks were measured across the surfaces of three plates, and are consistent with other thorium and protactinium peaks present in depleted uranium samples that are induced by the decay of 235 U and 238 U. Of the four peaks detected, three are dominated by the decay of 235 U, and one peak at 15.70 keV covers two characteristic X-rays from the zirconium diffusion barrier (Kα 1 ) and from a 231 Th 15.62 keV X-ray induced by 235 U α-decay. The low energies of these lines suggest that they are mostly emitted from the fuel meat surface, and the poor counting statistics caused by strong self-attenuation make these data a poor candidate for 235 U/ 238 U ratio analysis. We suggest, then, that these X-rays could be used for passive measurement of variations in the cladding thickness of these fuels to complement manual thickness measurement methods.

HALEU↗

Prediction of Transition-State Energies of Hydrodeoxygenation Reactions on Transition-Metal Surfaces Based on Machine Learning

Computational catalyst discovery involves identification of a meaningful model and suitable descriptors that determine the catalyst properties. We study the impact of combining various descriptors (e.g., reaction energies, metal descriptors, and bond counts) for modeling transition-state energies (TS) based on a database of adsorption and TS energies across transition-metal surfaces for the decarboxylation and decarbonylation of propionic acid, a chemistry characteristic for biomass conversion. Results of different machine learning models for more than 1572 descriptor combinations suggest that there is no statistically significant difference between linear and nonlinear models when using the right combination of reactant energies, metal descriptors, and bond counts. However, linear models are inferior when not including bond count and metal descriptors. In conclusion, when there are missing data for reaction steps on all metals, conventional linear scaling is inferior to linear and nonlinear models with proper choice of descriptors that are surprisingly robust.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accurate small and wide angle x-ray scattering profiles from atomic models of proteins and nucleic acids

A new method is introduced to compute X-ray solution scattering profiles from atomic models of macromolecules. The three-dimensional version of the Reference Interaction Site Model (RISM) from liquid-state statistical mechanics is employed to compute the solvent distribution around the solute, including both water and ions. X-ray scattering profiles are computed from this distribution together with the solute geometry. We describe an efficient procedure for performing this calculation employing a Lebedev grid for the angular averaging. The intensity profiles (which involve no adjustable parameters) match experiment and molecular dynamics simulations up to wide angle for two proteins (lysozyme and myoglobin) in water, as well as the small-angle profiles for a dozen biomolecules taken from the BioIsis.net database. The RISM model is especially well-suited for studies of nucleic acids in salt solution. Use of fiber-diffraction models for the structure of duplex DNA in solution yields close agreement with the observed scattering profiles in both the small and wide angle scattering (SAXS and WAXS) regimes. In addition, computed profiles of anomalous SAXS signals (for Rb{sup +} and Sr{sup 2+}) emphasize the ionic contribution to scattering and are in reasonable agreement with experiment. In cases where an absolute calibration of the experimental data at q = 0 is available, one can extract a count of the excess number of waters and ions; computed values depend on the closure that is assumed in the solution of the Ornstein–Zernike equations, with results from the Kovalenko–Hirata closure being closest to experiment for the cases studied here.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The high intensity diffractometer for residual stress analysis (HIDRA), a third generation residual stress mapping neutron diffractometer at the high flux isotope reactor

This paper describes the hardware and software upgrades, operation, and performance of the high intensity diffractometer for residual stress analysis (HIDRA) instrument, a residual stress mapping neutron diffractometer located at the High Flux Isotope Reactor at Oak Ridge National Laboratory in Oak Ridge Tennessee, USA. Following a major upgrade in 2018, the new instrument has a single 3 He multiwire 2D 30 × 30 cm 2 position sensitive detector, yielding a field of view of 17° 2θ. Further, the increase in the field of view (from 4° 2θ) from the previous model instrument has contributed to the tremendous improvement in the out of plane solid angle such that the 3D count rate could be obtained easily. Accordingly, the hardware, software, Data Acquisition System (DAS), and so on have also been updated. Finally, all these enhanced features of HIDRA have been ably demonstrated by conducting multi directional diffraction measurements in the quenched 750-T74 aluminum, and the evolved and improved strain/stress mappings are presented.

3D printing↗

Characterizing Tradeoffs in Memory, Accuracy, and Speed for Chemistry Tabulation Techniques

Chemistry tabulation is a common approach in practical simulations of turbulent combustion at engineering scales. Linear interpolants have traditionally been used for accessing precomputed multidimensional tables but suffer from large memory requirements and discontinuous derivatives. Higher-degree interpolants address some of these restrictions but are similarly limited to relatively low-dimensional tabulation. Artificial neural networks (ANNs) can be used to overcome these limitations but cannot guarantee the same accuracy as interpolants and introduce challenges in reproducibility and reliable training. These challenges are enhanced as the physics complexity to be represented within the tabulation increases. Here, we assess the efficiency, accuracy, and memory requirements of Lagrange polynomials, tensor product B-splines, and ANNs as tabulation strategies. We analyze results in the context of nonadiabatic flamelet modeling where higher dimension counts are necessary. While ANNs do not require structuring of data, providing benefits for complex physics representation, interpolation approaches often rely on some structuring of the table. Interpolation using structured table inputs that are not directly related to the variables transported in a simulation can incur additional query costs. This is demonstrated in the present implementation of heat losses. We show that ANNs, despite being difficult to train and reproduce, can be advantageous for high-dimensional, unstructured datasets relevant to nonadiabatic flamelet models. Furthermore we demonstrate that Lagrange polynomials show significant speedup for similar accuracy compared to B-splines.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

IDCS J1426.5+3508: DISCOVERY OF A MASSIVE, INFRARED-SELECTED GALAXY CLUSTER AT z = 1.75

We report the discovery of an IR-selected massive galaxy cluster in the IRAC Deep Cluster Survey (IDCS). We present new data from the Hubble Space Telescope and the W. M. Keck Observatory that spectroscopically confirm IDCS J1426.5+3508 at z = 1.75. Moreover, the cluster is detected in archival Chandra data as an extended X-ray source, comprising 53 counts after the removal of point sources. We calculate an X-ray luminosity of L{sub 0.5-2keV} = (5.4 {+-} 1.2) Multiplication-Sign 10{sup 44} erg s{sup -1} within r = 60 arcsec ({approx}1 Mpc diameter), which implies M{sub 200,L{sub x}}= (5.3{+-}1.6) Multiplication-Sign 10{sup 14} M{sub Sun }. IDCS J1426.5+3508 appears to be an exceptionally massive cluster for its redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

The mass and galaxy distribution around SZ-selected clusters

ABSTRACT We present measurements of the radial profiles of the mass and galaxy number density around Sunyaev–Zel’dovich (SZ)-selected clusters using both weak lensing and galaxy counts. The clusters are selected from the Atacama Cosmology Telescope Data Release 5 and the galaxies from the Dark Energy Survey Year 3 data set. With signal-to-noise ratio of 62 (45) for galaxy (weak lensing) profiles over scales of about 0.2–20 h−1 Mpc, these are the highest precision measurements for SZ-selected clusters to date. Because SZ selection closely approximates mass selection, these measurements enable several tests of theoretical models of the mass and light distribution around clusters. Our main findings are: (1) The splashback feature is detected at a consistent location in both the mass and galaxy profiles and its location is consistent with predictions of cold dark matter N-body simulations. (2) The full mass profile is also consistent with the simulations. (3) The shapes of the galaxy and lensing profiles are remarkably similar for our sample over the entire range of scales, from well inside the cluster halo to the quasilinear regime. We measure the dependence of the profile shapes on the galaxy sample, redshift, and cluster mass. We extend the Diemer & Kravtsov model for the cluster profiles to the linear regime using perturbation theory and show that it provides a good match to the measured profiles. We also compare the measured profiles to predictions of the standard halo model and simulations that include hydrodynamics. Applications of these results to cluster mass estimation, cosmology, and astrophysics are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

The Effects of Radiation and Emitted Light Transport on the Positional Response of 11 cm × 42.5 cm × 5.5 cm NaI(Tl) Detectors

Experiments were performed with 30 11 cm x 42.5 x cm 5.5 cm NaI(Tl) detectors to better understand their positional response. Spectra were collected using 0.02 to 0.15 MBq point sources of 241 Am, 137 Cs, 60 Co, and 133 Ba positioned on lines parallel and perpendicular to the long axis of the crystal along both the narrow and wide detector faces as well as at different distances from them. A greater density of positions was sampled at the ends of the detector, and repeated measurements were made to examine potential gain drifts during the experiment. Spectroscopic peak counts, spectroscopic pulse heights, and net counts were analyzed. Empirical equations were fit to the aforementioned data for each specific source energy as a function of source position. In addition, a Monte Carlo radiation transport code was used to simulate the expected positionally variable response based solely upon radiation absorption. The simulated radiation transport efficiency functions were compared to the experimental data. The effects of the geometric radiation efficiency, the attenuation and scattering of emitted light within the scintillation crystal, and combined effects such as non-uniformity of the photomultiplier tube photocathode response and crystal irregularities were then distinguished. Functions describing each effect were derived. The results suggest potential new corrections to data obtained with large scintillation detectors as well as a novel approach to partial positional gamma-ray detection with minimal collimation, given that the energy resolution is within reason for particular photopeaks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving results on transverse double spin asymmetries in the CNI region at STAR

Double spin effects in polarized pp-elastic scattering in the Coulomb nuclear interference (CNI) region are sensitive to small contributions to the nuclear amplitude in addition to Pomeron exchange dominating at high energies. Measurements of double spin asymmetries require external luminosity normalization using collision counts for all spin combinations. Several possible sources of such data from various STAR subsystems were thoroughly analyzed to make the best choice. BBC arrays were found to be free of double spin effects to the level of ∼ 2 × 10{sup −4} thus leading to the systematic uncertainty ∼10{sup −3} in the value of (A {sub NN }+ A {sub SS })/2.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NEWTS Well Summary by Hydrologic Regions and Subbasins in the U.S.

Oil and gas well production data (2000-2022), including water production and injection, as well as summary information (e.g., well count by status, total vertical depth statistics, etc.) spatially summarized by Watershed Boundary Dataset's (WBD) region (Hydrologic Unit Code (HUC) 2) and subbasin (HUC8). Energy-related produced waters data were acquired and summarized in support of the development of the National Energy Technology Laboratory's NEWTS (National Energy Water Treatment and Speciation Database). Due to the proprietary nature of the wellbore data, this derived product has been spatially compiled by key areas to support research and stakeholder needs.

Energy Infrastructure↗

On-Site Inspection RadioIsotopic Spectroscopy (Osiris) System-Integration and Field-Testing Report

We have designed a system for the acquisition and analysis of high-resolution gamma-ray spectra during on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The On-Site Inspection RadioIsotopic Spectroscopy—OSIRIS —gamma-ray spectrometer is a mechanically-cooled, battery-powered ORTEC IDM-200V, chosen to avoid the need for liquid nitrogen during on-site inspections. The spectrometer is controlled and the spectral data analyzed by a Panasonic Toughbook notebook computer. Spectral data analysis is similar to that performed by traditional gamma-ray spectrometers, except the OSIRIS gamma-ray spectral data are filtered to display only radioisotopic information relevant to CTBT on-site inspections, for example, the fission-product isotope Zr-95 and its daughter isotope Nb-95. The OSIRIS software assists the user during operation with software checklists for startup and shutdown, and menu-selected display windows during energy calibration and data acquisition. OSIRIS can be operated in either sample-counting mode or the in-situ mode. In this report, the extensive system-integration tests of the OSIRIS system carried out in 2015-2017 are described, including tests at Idaho National Laboratory, at the Nevada National Security Site (formerly, the Nevada Test Site), and at Pacific Northwest National Laboratory in Richland, Washington. We also note recent software enhancements and the steps to our successful commercialization of OSIRIS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Filtration Performance Results: Sierra Peaks Material No. 4

Sandia National Laboratories (SNL) assessed the filtration performance of materials from Sierra Peaks to identify alternatives which may perform similarly to materials used in FDA-approved N95 respirators. This work is meant to characterize the aerosol performance of materials to give Sierra Peaks information for them to determine if they elect to submit masks made using these materials for follow-on N95 certification testing at an accredited facility. The R&D testbed used is a large-scale filtration system designed to test commercial filter boxes. System modifications were performed to simulate, where possible, parameters defined by the National Institute for Occupational Safety and Health (NIOSH) for certification of filter materials for N95 respirators (NIOSH 2019). The system is a pull-through design. Air enters through a Laminar Flow Element (LFE) and the volumetric flow is measured based on the pressure drop across the LFE. Pressure is measured via a Pressure Transducer (PT). The air then passes through a High Efficiency Particulate Air (HEPA) filter to purge the air of ambient airborne particulates. Test aerosol is injected into the flow shortly after and mixing is induced via a coarse mesh. The airflow is allowed to fully develop prior to arriving at the test section. The aerosol then passes through the test material mounted in a box in the test section. Pressure drop across the test article is measured and aerosol sampling probes measure the aerosol concentrations upstream and downstream of the sample. The air passes through a second HEPA filter prior to being exhausted to ambient by a blower. A Topas aerosol generator is used to produce the test aerosol from Sodium Chloride (NaC1) dissolved in deionized (DI) water. Generated aerosol passes through a heated mixing chamber and a desiccant dryer to produce nanosized solid-state particulates. A dilution loop allows for the aerosol concentration to be regulated. The aerosol sampling probes upstream and downstream of the test section are aligned with the flow path. These are ducted directly to the aerosol sizing and counting instruments. A Laser Aerosol Spectrometer (LAS) was used for data collection in the original configuration of the system and was also used for initial testing in this project. Because the lower measurement range for the LAS is 90 nanometers (nm), the LAS was switched out for a more complicated Scanning Mobility Particle Sizer (SMPS) spectrometer system. The SMPS is comprised of an Electrostatic Classifier (EC), Differential Mobility Analyzer (DMA), and a Condensation Particle Counter (CPC). This enabled data collection at 75 nm, the particle size called out in the NIOSH guidelines.

36 MATERIALS SCIENCE↗

Studying the Effects of Overlapping Objects in Dark Energy

Observing the clustering of galaxies allows us to calculate cosmological parameters necessary for understanding dark energy. However, as the density of observed objects increases, the probability of these objects blending likewise increases, causing multiplegalaxies to be observed as one. This affects the calculated values of parameters such as the galaxy bias (b) and the matter energy density (ΩM). To see whether the bias from incorrectly inferring the galaxy count is significant, we compare the correlation functions in simulated data for “observed” and “true” data sets with one-to-one andmultiple-to-one correspondences.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Capabilities of an Acoustic Camera to Inform Fish Collision Risk with Current Energy Converter Turbines

A diversified energy portfolio may include marine energy in the form of current energy converters (CECs) such as tidal or in-river turbines. New technology development in the research stage typically requires monitoring for environmental effects. A significant environmental effect of concern for CECs is the risk of moving parts (e.g., turbine blades) colliding with animals such as fishes. CECs are installed in energetic locations in which it is difficult to operate sensors to fulfill monitoring requirements for informing collision risk. Collecting data (i.e., about blade strikes or near-misses) that inform interactions of fishes with CECs is usually attempted using active acoustic sensors or video cameras (VCs). Limitations of low-light conditions or water turbidity that preclude effective use of VCs are overcome by using high-resolution multibeam echosounders (or acoustic cameras (ACs)). We used an AC at two sites to test its ability to detect artificial and real fish targets and determine if strike, near-miss, and near-field behavior could be observed. Interactions with fish and artificial targets with turbines have been documented but strike confirmation with an AC is novel. The first site was in a tidal estuary with a 25 kW turbine and water clarity sufficient to allow VC data to be collected concurrently with AC data showing turbine blade strike on tethered artificial fish targets. The second site was a turbid, debris-laden river with a 5 kW turbine where only AC data were collected due to high water turbidity. Data collection at the second site coincided with downstream Pacific salmon (Oncorhynchus spp.) smolt migration. Physical fish capture downstream of the turbine was performed with an incline plane trap (IPT) to provide context for the AC observations, by comparing fish catches. Discrimination between debris and fishes in the AC data was not possible, because active movement of fishes was not discernable. Nineteen fishes were released upstream of the turbine to provide known times of possible fish/turbine interactions, but detection was difficult to confirm in the AC data. ACs have been used extensively in past studies to count large migratory fish such as Pacific salmon, but their application for small fish targets has been limited. The results from these two field campaigns demonstrate the ability of ACs to detect targets in turbid water and observe blade strikes, as well as their limitations such as the difficulty of distinguishing small fishes from debris in a high-energy turbid river. Recommendations are presented for future applications associated with CEC device testing.

16 TIDAL AND WAVE POWER↗

Electronic strain-level counter

An electronic strain level counter for obtaining structural strain data on in-flight aircraft is described. The device counts the number of times the strain at a point on an aircraft structural member exceeds each of several preset levels. A dead band is provided at each level to prohibit the counting of small strain variations around a given preset level.

Pitts, F. L.↗

A review of the Jovian magnetosphere based upon Pioneer 10 and 11

A review and analysis are presented of data derived from the Pioneer 10 and Pioneer 11 flybys of Jupiter on the Jovian plasma, magnetic field, and energetic particles in circumjovian space. The design of the space probes is described along with the principal experiments flown. Overall features of the Jovian magnetosphere are drawn and contrasted with the earth's magnetosphere. The trajectories of the two space probes are contrasted and their data on Jupiter's plasmasphere are correlated. Isointensity contours and count rates of energetic particles are plotted, flux tubes within the Jovian magnetosphere are mapped, the ring current (plasma torus) encircling the planet is described, and possible effects of solar wind and of the moons immersed in Jupiter's magnetosphere are considered.

Trainor, J. H.↗

The High Resolution Imaging Instrument for HEAO-B

The High Resolution Imaging Instrument for the HEAO-B X-ray Telescope satellite is designed to reproduce images of celestial X-ray sources in the range of 0.2 to 4.0 keV. It provides both imaging and temporal data. The basic detector is a two-stage microchannel plate with a crossed-grid charge detector. Preamplifiers, detector bias supplies, and some processing circuits are colocated with the detector. The remaining electronic circuits are located in a remote central electronic assembly. The processing system is designed for single-photon processing. The imaging data rate is limited to 100 data points per second. Non-imaging total-field count rate is acquired with a maximum dead time of 14 microseconds per event.

Kubierschky, K.↗

A catalog of red stars near L1454

In view of their potential interest as individual objects of study, a catalog is presented of stars noted by the Duerr and Craine (1982) study of the nature of the dark cloud L1454 to have V-I magnitudes greater than about 2.5. Finding charts are given for these 156 stars, with attention to the individual quadrants of the region studied. The original star counts had been made with Near Infrared Photographic Sky Survey data.

Duerr, R.↗