Search NASA⌕ Search

SEARCH · Search NASA

Results for “device packaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Heat flux estimates of power balance on Proto-MPEX with IR imaging

The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) at Oak Ridge National Laboratory (ORNL) is a precursor linear plasma device to the Material Plasma Exposure eXperiment (MPEX), which will study plasma material interactions (PMIs) for future fusion reactors. This paper will discuss the initial steps performed towards completing a power balance on Proto-MPEX to quantify where energy is lost from the plasma, including the relevant diagnostic package implemented. Machine operating parameters that will improve Proto-MPEX’s performance may be identified, increasing its PMI research capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiphysics modeling of accelerators through code integration

This work aims to improve the ability of particle accelerator researchers to develop high-performance accelerator cavity designs by creating an overall multiphysics framework that integrates and couples existing application codes. This framework will allow accelerator researchers to build multiphysics models that will optimize cavity design, improve understanding of whole-device performance, and reduce the development and fabrication costs of accelerator research. We utilize the open-source VizSchema data standard as an intermediate data structure interface layer to standardize interfaces between individual application codes. VizScema is extensively documented online, and plugins for VizSchema are available for popular visualization packages, including VisIt and ParaView. Currently, the work focuses on coupling the EM field solver COMSOL and the electron gun code MICHELLE to allow COMSOL field-solve results to be seamlessly used by MICHELLE for particle-solve. Later work will extend this integration to include other fields, particles, and thermodynamics simulation codes.

43 PARTICLE ACCELERATORS↗

An active nutation damper for spacecraft

An active nutation damping device, consisting of an angular accelerometer, a dc-motor-driven flywheel, and associated electronics, developed for spacecraft use is described. This damping system was used on the LAGEOS spacecraft to control nutation buildup during the long coast period (approximately 75 minutes) after the third stage separation. The damper package was evaluated and proven on a three-axis gas-bearing simulator that duplicated the LAGEOS spacecraft critical flight dynamics. In addition, a failure analysis of the damper assembly was performed. Performance of the damper during the LAGEOS flight has confirmed the preflight evaluation and analysis.

Abercrombie, R. A.↗

Environmental Stress Testing of the Single Sample Cylinder: A Proven Consensus Standard for Internal Gas Analysis (IGA) or Residual Gas Analysis (RGA)

In August 2008, Schuessler Consulting was contracted by NASA GSFC in support of the NASA Electronic Parts and Packaging (NEPP) program to perform two separate studies on moisture laden air in a stainless steel cylinder that had been designed to become a consensus standard for Test Method 1018. This Test Method was originally released for hybrids under Mil. Std. 883 but was quickly utilized on other microelectronic devices under the auspice of Mil. Std. 750. The cylinder had subsequently been fabricated for the 750 community. It was back-filled with moist air and subsequently analyzed over a period of time under a previous NASA contract. It had been shown that moisture in the 4000 - 5000 ppm range could be analyzed rather precisely with a mass spectrometer, commonly referred to as a Residual Gas Analyzer (RGA). The scope of this study was to ascertain if the composition and precision varied as a function of thermal shock at sub-zero temperatures and whether there was consensus when the standard was submitted to other RGA units. It was demonstrated and published that the consensus standard would yield precise RGA data for moisture within +/- 1% when optimized for a given RGA unit. It has been subsequently shown in this study at Oneida Research Services, that sub-zero storage did not affect that precision when a well-defined protocol for the analysis was followed. The consensus standard was taken to a second facility for analysis where it was found that moisture adsorption on the transfer lines caused precision to drop to +/- 12%. The Single Sample Cylinder (SSC) is a one liter stainless steel cylinder with associated sampling valves and has considerable weight and volume. But this considerable size allows for approximately 300 gas samples of the same composition to be delivered to any RGA unit. Lastly, a smaller cylinder, approximately 75 cc, of a second consensus standard was fabricated and tested with a different mix of fixed gases where moisture was kept in the 100 ppm range. This second standard has the potential of providing 30 gaseous samples and can be readily shipped to any analytical facility that desires to generate comparison RGA data. A series of comparison residual gas analyses was performed at the Honeywell Federal Manufacturing & Technologies facility in the National Nuclear Facility Administration s plant in Kansas City to complete this project. It was shown that improvements in the precision of a given RGA unit can be done by controlling the cycle time for each analysis and increasing analysis temperatures to minimize moisture adsorption. It was also found that a "one time event" in the subzero storage of the large SSC did not effect the units ability to continuously supply precise samples of the same chemistry, however the "event" caused a permanent +8% shift in the reported value of the moisture content. Lastly, a set of SSC RGA results was plotted on a common graph with DSCC "correlation study" RGA data. The result demonstrates the ability of the SSC to remove many of the individual variances that single, individual samples introduce. The consensus standards are now in storage at Oneida Research Services, one of the DSCC certified houses that does RGA to Military Standards, where they await future studies. The analytical data and the operational parameters of the instruments used are provided in the following discussion. Limitations and suggested means for improvement of both precision and accuracy are provided.

Schuessler, Philipp WH↗

Laser-based Sensors for Chemical Detection

Stand-off detection of hazardous materials ensures that the responder is located at a safe distance from the suspected source. Remote detection and identification of hazardous materials can be accomplished using a highly sensitive and portable device, at significant distances downwind from the source or the threat. Optical sensing methods, in particular infrared absorption spectroscopy combined with quantum cascade lasers (QCLs), are highly suited for the detection of chemical substances since they enable rapid detection and are amenable for autonomous operation in a compact and rugged package. This talk will discuss the sensor systems developed at Pacific Northwest National Laboratory and will discuss the progress to reduce the size and power while maintaining sensitivity to enable stand-off detection of multiple chemicals.

47 OTHER INSTRUMENTATION↗

The development of a population of 4D pediatric XCAT phantoms for imaging research and optimization

Purpose: We previously developed a set of highly detailed 4D reference pediatric extended cardiac-torso (XCAT) phantoms at ages of newborn, 1, 5, 10, and 15 yr with organ and tissue masses matched to ICRP Publication 89 values. In this work, we extended this reference set to a series of 64 pediatric phantoms of varying age and height and body mass percentiles representative of the public at large. The models will provide a library of pediatric phantoms for optimizing pediatric imaging protocols. Methods: High resolution positron emission tomography-computed tomography data obtained from the Duke University database were reviewed by a practicing experienced radiologist for anatomic regularity. The CT portion of the data was then segmented with manual and semiautomatic methods to form a target model defined using nonuniform rational B-spline surfaces. A multichannel large deformation diffeomorphic metric mapping algorithm was used to calculate the transform from the best age matching pediatric XCAT reference phantom to the patient target. The transform was used to complete the target, filling in the nonsegmented structures and defining models for the cardiac and respiratory motions. The complete phantoms, consisting of thousands of structures, were then manually inspected for anatomical accuracy. The mass for each major tissue was calculated and compared to linearly interpolated ICRP values for different ages. Results: Sixty four new pediatric phantoms were created in this manner. Each model contains the same level of detail as the original XCAT reference phantoms and also includes parameterized models for the cardiac and respiratory motions. For the phantoms that were 10 yr old and younger, we included both sets of reproductive organs. This gave them the capability to simulate both male and female anatomy. With this, the population can be expanded to 92. Wide anatomical variation was clearly seen amongst the phantom models, both in organ shape and size, even for models of the same age and sex. The phantoms can be combined with existing simulation packages to generate realistic pediatric imaging data from different modalities. Conclusions: This work provides a large cohort of highly detailed pediatric phantoms with 4D capabilities of varying age, height, and body mass. The population of phantoms will provide a vital tool with which to optimize 3D and 4D pediatric imaging devices and techniques in terms of image quality and radiation-absorbed dose.

60 APPLIED LIFE SCIENCES↗

US Hybrid Northeast Demonstration and Deployment of FCRxNV200 (DE-EE0007276 Final Report)

In this project, US Hybrid and other strategic project partners, collaborated to build a fuel cell range extended plug-in hybrid utility vehicle and demonstrate it in real-world operation. The base vehicle platform to be modified to the hybrid platform was the Nissan e-NV200, which is an all-electric version of the NV200 commercial cargo van. This is a Class 1 vehicle with a GVWR of approx. 4,900 lbs., wheelbase of 115 inches, and cargo capacity of approx. 122ft. The 80kW/254N-m electric powertrain is the same as Nissan’s LEAF, but with a revised final drive ratio (9.301 vs. 8.194) to accommodate higher payloads with lower top speed. US Hybrid utilized a purpose built, freeze capable, integrated fuel cell engine FCe™10 to hybridize and range-extend the existing e-NV200 vehicle with OEM drivetrain. The eNV200 has the same size battery as the LEAF with a different rear axle ratio. Fuel cell stack size and balance of plant (BOP) configuration were designed for compact under the hood vehicle packaging. Engine design took into consideration the need for high efficiency (>50% at all loads & up to 62% at partial power), optimal heat recovery for cabin heating, and low maintenance. The technology of the isolated DC-DC converter operating at >100kHz enables extremely high efficiency (ZVS and SIC power devices) and robust performance while reducing system complexity, weight, and volume. This enables an extended vehicle range of up to 250 miles and an operational life that should provide lower total cost of ownership (TCO) to the end user.

33 ADVANCED PROPULSION SYSTEMS↗

Applications of high thermal conductivity composites to electronics and spacecraft thermal design

Recently, high thermal conductivity continuous graphite fiber reinforced metal matrix composites (MMC's) have become available that can save much weight over present methods of heat conduction. These materials have two or three times higher thermal conductivity in the fiber direction than the pure metals when compared on a thermal conductivity to weight basis. Use of these materials for heat conduction purposes can result in weight savings of from 50 to 70 percent over structural aluminum. Another significant advantage is that these materials can be used without the plumbing and testing complexities that accompany the use of liquid heat pipes. A spinoff of this research was the development of other MMC's as electronic device heat sinks. These use particulates rather than fibers and are formulated to match the coefficient of thermal expansion of electronic substrates in order to alleviate thermally induced stresses. The development of both types of these materials as viable weight saving substitutes for traditional methods of thermal control for electronics packaging and also for spacecraft thermal control applications are the subject of this report.

Sharp, G. Richard↗

Standardizing GPU Radiation Test Approaches

While some Graphical Processing Units (GPUs) are discrete components (i.e.GTX1050), others take the form of an IP block or embedded engine within a System on Chip (SoC) device such as the Qualcomm Snapdragon"TM" 820 which contains a Qualcomm Adreno"TM" 530 GPU. Within this device are various functional blocks which can be exercised with software payloads. NVidia's Jetson"TM" TX1 SoC is provided on a System on Module (SOM). Within it are Central Processing Unit (CPU) cores and an nVidia GPU which can be accessed similarly to a discrete GPU coprocessor. While the packaging is different, each one of these GPUs needs to be tested using the same standardized code.

Single Event Effects (SEE)↗

Soft Core/Shell Packages for Stretchable Electronics

This paper presents materials and core/shell architectures that provide optimized mechanical properties in packages for stretchable electronic systems. Detailed experimental and theoretical studies quantitatively connect the geometries and elastic properties of the constituent materials to the overall mechanical responses of the integrated systems, with a focus on interfacial stresses, effective modulus, and maximum extent of elongation. Specific results include core/shell designs that lead to peak values of the shear and normal stresses on the skin that remain less than 10 kPa even for applied strains of up to 20%, thereby inducing minimal somatosensory perception of the device on the human skin. Additional, strain-limiting mesh structures embedded in the shell improve mechanical robustness by protecting the active components from strains that would otherwise exceed the fracture point. Demonstrations in precommercial stretchable electronic systems illustrate the utility of these concepts.

36 MATERIALS SCIENCE↗

Preliminary design report, Large Space Telescope OTA/SI Phase B study: High speed area photometer

A photometer is examined which combines several features from separate instruments into a single package. The design presented has both point and area photometry capability with provision for inserting filters to provide spectral discrimination. The electronics provide for photon counting mode for the point detectors and both photon counting and analog modes for the area detector. The area detector also serves as a target locating device for the point detectors. Topics discussed include: (1) electronic equipment requirements, (2) optical properties, (3) structural housing for the instrument, (4) motors and other mechanical components, (5) ground support equipment, and (6) environment control for the instrument. Engineering drawings and block diagrams are shown.

Source record↗

Planet X probe: A fresh new look at an old familiar place

Planet X Probe utilizes a Get Away Special (GAS) payload to provide a large student population with a remote Earth sensing experimental package. To provide a cooperative as well as a competitive environment, the effort is targeted at all grade levels and at schools in different geographical regions. LANDSAT capability allows students to investigate the Earth, its physical makeup, its resources, and the impact of man. This project also serves as an educational device to get students to stand back and take a fresh look at their home planet. The key element is to treat the familiar Earth as an unknown planet with knowledge based only on what is observable and provable from the images obtained. Through participation, a whole range of experiences will include: (1) mission planning; (2) research and pilot projects to train teams; (3) identification and recruitment of scientific mentors and dialogue; (4) selection of a student advisory team to be available during the mission; (5) analysis of data and compilation of findings; (6) report preparation, constucted along sound scientific principles; and (7) presentation and defense of findings before a meeting of competitive student groups and scientist in the field.

Nicholson, James↗

SiC Field Effect Transistor Technology Demonstrating Prolonged Stable Operation at 500 C

While there have been numerous reports of short-term transistor operation at 500 degree C or above, these devices have previously not demonstrated sufficient long-term operational durability at 500 degree C to be considered viable for most envisioned applications. This paper reports the development of Silicone Carbi field effect transistors capable of long-term electrical operation at 500 degree C. A 6H-SiC MESFET was packaged and subjected to continuous electrical operation while residing in a 500 degree C oven in oxidizing air atmosphere for over 2400 hours. The transistor gain, saturation current (IDSS), and on-resistance (RDS) changed by less than 20% from initial values throughout the duration of the biased 500 degree C test. Another high-temperature packaged 6H-SiC MESFET was employed to form a simple one-stage high-temperature low-frequency voltage amplifier. This single-stage common-source amplifier demonstrated stable continuous electrical operation (negligible changes to gain and operating biases) for over 600 hours while residing in a 500 degree C air ambient oven. In both cases, increased leakage from annealing of the Schottky gate-to-channel diode was the dominant transistor degradation mechanism that limited the duration of 500 degree C electrical operation.

Neudeck, Philip G.↗

Integrated power electronics using a ferrite%3CU%2B2010%3Ebased low%3CU%2B2010%3Etemperature co%3CU%2B2010%3Efired ceramic materials system.

This paper discusses a new approach to making hybrid power electronic circuits by combining a low-temperature (850 C to 950 C) co-fired ceramic (LTCC) substrate, planar LTCC ferrite transformers/inductors and integrated passive components into a multilayer monolithic package using a ferrite-based LTCC material system. A ferrite tape functions as the base material for this LTCC system. The material system includes physically and chemically compatible dielectric paste, dielectric tape and conductor materials which can be co-fired with the base ferrite LTCC tape to create sintered devices with excellent magnetic coupling, high permeability ({approx}400), high resistivity (> 10{sup 12} {Omega} {center_dot} cm) and good saturation ({approx}0.3 T). The co-fired ferrite and dielectric materials can be used as a substrate for attaching or housing semiconductor components and other discrete devices that are part of the power electronics system. Furthermore, the ability to co-fire the ferrite with dielectric and conductor materials allows for the incorporation of embedded passives in the multilayer structure to create hybrid power electronic circuits. Overall this thick film material set offers a unique approach to making hybrid power electronics and could potentially allow a size reduction for many commercial dc-dc converter and other power electronic circuits.

36 MATERIALS SCIENCE↗

Remote Handling Approach for Whiteshell Laboratories Standpipe and Bunker Legacy Waste Retrieval - 18417

Veolia Nuclear Solutions (VNS) has been contracted by Canadian Nuclear Laboratories (CNL) to design and delivery a system to retrieve and repackage legacy waste on-site. The waste has a variety of forms and conditions and requires a flexible and robust set of remote handling devices to complete the task. The focus of this paper is to highlight the remote handling philosophy being used on the project which can be applicable to other projects. This approach is based on past experience and uses a range of remote handling devices and techniques matched to the variety of tasks in the project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experiment S010: Agena micrometeorite collection

A study was made of the micrometeoroid content of the upper atmosphere and the near-earth space environment. Highly polished collection surfaces attached to the target docking adapter (TDA) were exposed to micrometeorite impact and debris collection during the Gemini 8, 9, and 10 missions. Also, the device was attached to the Gemini Agena target vehicle (GATV) during the Gemini 12 mission. The effects of space environment exposure on viable microorganisms were recorded. No substantive data regarding space environment micrometeorite content were derived from the Gemini 9 or 12 missions. However, some substantive data were obtained from the experiment package that was retrieved from the Gemini 10 mission. The micrometeorite-flux values obtained were in general agreement with values obtained from previous experiments by the use of other experimental equipment. The microorganisms that were retrieved from the Gemini 10 experiment package did not survive. However, the same kinds of specimens inside the package had good survival rates. Upon initial analysis, it appeared that the closed-cover shielding was a contributing factor in the protection and survival of the microorganisms.

Hemenway, C. L.↗

Applications of high thermal conductivity composites to electronics and spacecraft thermal design

Recently, high thermal conductivity graphite fiber-reinforced metal matrix composites (MMCs) have become available that can save weight over present methods of heat conduction. Another significant advantage is that these materials can be used without the plumbing and testing complexities that accompany the use of liquid heat pipes. A spinoff of this research was the development of other MMCs as electronic device heat sinks. These use particulates rather than fibers and are formulated to match the coefficient of thermal expansion of electronic substrates in order to alleviate thermally induced stresses. The development of both types of these materials as viable weight-saving substitutes for the traditional methods of thermal control for electronics packaging and also for spacecraft thermal control applications are the subjects of this report.

Sharp, G. Richard↗

Results of the Quasi-Steady Acceleration Environment from the STS-62 Missions

One of the clear benefits of conducting scientific research in space is to take advantage of the reduced acceleration environment. Many accelerometer packages have proven to accurately measure the acceleration environment at frequency levels above one Hz. However, for particular classes of experiments the quality of science returns is a direct function of the extremely low frequency (less than 0.01 Hz), quasi-steady acceleration environment. One class particularly interested in this acceleration regime is the group of crystal growth experimenters. These scientists are primarily interested in knowing the resultant quasi-steady acceleration vector at their respective crystal growth locations. The objective of many of these scientists is to minimize the amount of convective flow acting in a direction perpendicular to the growth axis of the crystal. Convective flow within the crystal can be induced by the direction and magnitude of the quasi-steady acceleration vector. Convective flows acting perpendicular to the growth axis of the crystal can cause nonuniformity within the crystal, thus reducing the quality of the results. The Orbital Acceleration Research Experiment (OARE), an accelerometer package hardmounted to the bottom of the payload bay of the orbiter Columbia (OV-102), has the capability of monitoring and recording the quasi-steady acceleration environment. This paper will describe the components that make up the on-orbit quasi-steady acceleration environment, detail how results from the OARE device were achieved, and compare modelled acceleration results with actual on-orbit OARE results from the STS-62 and STS-65 flights. A summary of the results will be provided along with possible recommendations of how to combine modelled and realtime quasi-steady accelerometer data for future Shuttle flights.

Matisak, Brian↗