Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Three axis vector atomic magnetometer utilizing polarimetric technique

The three axis vector magnetic field measurement based on the interaction of a single elliptically polarized light beam with an atomic system is described. The magnetic field direction dependent atomic responses are extracted by the polarimetric detection in combination with laser frequency modulation and magnetic field modulation techniques. The magnetometer geometry offers additional critical requirements like compact size and large dynamic range for space application. Further, the three axis magnetic field is measured using only the reflected signal (one polarization component) from the polarimeter and thus can be easily expanded to make spatial array of detectors and/or high sensitivity field gradient measurement as required for biomedical application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Readout models for BaFBr 0.85 I 0.15 :Eu image plates

The linearity of the photostimulated luminescence process makes repeated image-plate scanning a viable technique to extract more dynamic range. In order to obtain a response estimate, two semi-empirical models for the readout fading of an image plate are introduced; they relate the depth distribution of activated photostimulated luminescence centers within an image plate to the recorded signal. Model parameters are estimated from image-plate scan series with BAS-MS image plates and the Typhoon FLA 7000 scanner for the hard x-ray image-plate diagnostic over a collection of experiments providing x-ray energy spectra whose approximate shape is a double exponential.

47 OTHER INSTRUMENTATION↗

Fractal diffusion in high temperature polymer electrolyte fuel cell membranes

In this paper, the performance of fuel cells depends largely on the proton diffusion in the proton conducting membrane, the core of a fuel cell. High temperature polymer electrolyte fuel cells are based on a polymer membrane swollen with phosphoric acid as the electrolyte, where proton conduction takes place. We studied the proton diffusion in such membranes with neutron scattering techniques which are especially sensitive to the proton contribution. Time of flight spectroscopy and backscattering spectroscopy have been combined to cover a broad dynamic range. In order to selectively observe the diffusion of protons potentially contributing to the ion conductivity, two samples were prepared, where in one of the samples the phosphoric acid was used with hydrogen replaced by deuterium. The scattering data from the two samples were subtracted in a suitable way after measurement. Thereby subdiffusive behavior of the proton diffusion has been observed and interpreted in terms of a model of fractal diffusion. For this purpose, a scattering function for fractal diffusion has been developed. The fractal diffusion dimension d w and the Hausdorff dimension d f have been determined on the length scales covered in the neutron scattering experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated assignment of rotational spectra using artificial neural networks

Here, a typical broadband rotational spectrum may contain several thousand observable transitions, spanning many species. While these spectra often encode troves of chemical information, identifying and assigning the individual spectra can be challenging. Traditional approaches typically involve visually identifying a pattern. A more modern approach is to apply an automated fitting routine. In this approach, combinations of 3 transitions are searched by trial and error, to fit the A , B , and C rotational constants in a Watson-type Hamiltonian. In this work, we develop an alternative approach-to utilize machine learning to train a computer to recognize the patterns inherent in rotational spectra. Broadband high-resolution rotational spectra are perhaps uniquely suited for pattern recognition, assignment, and species identification using machine learning. Repeating patterns of transition frequencies and intensities are now routinely recorded in broadband chirped-pulse Fourier transform microwave experiments in which both the number of resolution elements and the dynamic range surpass 10 4 . At the same time, these high-resolution spectra are extremely sensitive to molecular geometry with each polar species having a unique rotational spectrum. Here we train the feed forward neural network on thousands of rotational spectra that we calculate, using the rules of quantum mechanics, from randomly generated sets of rotational constants and other Hamiltonian parameters. Reasonable physical constraints are applied to these parameter sets, yet they need not belong to existing species. A trained neural network presented with a spectrum identifies its type (e.g., linear molecule, symmetric top, or asymmetric top) and infers the corresponding Hamiltonian parameters (rotational constants, distortion, and hyperfine constants). The classification and prediction times, about 160 μs and 50 μs, respectively, seem independent of the spectral complexity or the number of molecular parameters. We describe how the network works, provide benchmarking results, and discuss future directions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Environmental influences on autocollimator-based angle and form metrology

Deflectometric profilometers are indispensable tools for the precision form measurement of beam-shaping optics of synchrotrons and x-ray free electron lasers. They are used in metrology labs for x-ray optics worldwide and are crucial for providing measurement accuracy dictated by the form tolerances for modern state-of-the-art x-ray optics. Deflectometric profilometers use surface slope (angle) to assess form, and they utilize commercial autocollimators for the contactless slope measurement. In this contribution, we discuss the influences of environmental parameters, such as temperature and air pressure, including their gradients, on high-accuracy metrology with autocollimators in profilometers. They can cause substantial systematic errors in form measurement, especially in the case of large and strongly curved optical surfaces of high dynamic range. Relative angle and form measuring errors of the order of 10 -4 are to be expected. We characterize environmental influences by extended theoretical and experimental investigations and derive strategies for correcting them. Additionally, we report on the possibility to minimize the contributions of some errors by the application of sophisticated experimental arrangements and methods. We aim at approaching fundamental limits in autocollimator-based slope and form metrology.

47 OTHER INSTRUMENTATION↗

Absolute calibration of GafChromic film for very high flux laser driven ion beams

We report on the calibration of GafChromic HD-v2 radiochromic film in the extremely high dose regime up to 100 kGy together with very high dose rates up to 7 × 10 11 Gy/s. The absolute calibration was done with nanosecond ion bunches at the Neutralized Drift Compression Experiment II particle accelerator at Lawrence Berkeley National Laboratory (LBNL) and covers a broad dose dynamic range over three orders of magnitude. We then applied the resulting calibration curve to calibrate a laser driven ion experiment performed on the BELLA petawatt laser facility at LBNL. Here, we reconstructed the spatial and energy resolved distributions of the laser-accelerated proton beams. The resulting proton distribution is in fair agreement with the spectrum that was measured with a Thomson spectrometer in combination with a microchannel plate detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-high-bandwidth polarization interferometry and optimal quadratic phase detection

A novel homodyne interferometer and analysis method are described which use orthogonal polarization components to measure large rapid changes in interferometric phase, in quadrature, in the presence of strong time-dependent attenuation of the scene beam. Here, this approach overcomes the major sources of error associated with homodyne interferometry (sensitivity nulls, ambiguity in the direction of phase change when passing through a sensitivity null, and intolerance to beam power variations) while maintaining its intrinsic simplicity and speed, enabling extremely high-bandwidth, high-dynamic range measurements limited only by available detector technology. Using this technique, electron density in a magnetized plasma shock was measured with unprecedented bandwidth and resolution, revealing short-timescale features not previously observed.

47 OTHER INSTRUMENTATION↗

Heterodyne Detection of Radio-Frequency Electric Fields Using Point Defects in Silicon Carbide.

Sensing electric fields with high sensitivity, high spatial resolution, and at radio frequencies can be challenging to realize. Recently, point defects in silicon carbide have shown their ability to measure local electric fields by optical conversion of their charge state. Here, we report the combination of heterodyne detection with charge-based electric field sensing, solving many of the previous limitations of this technique. Owing to the nonlinear response of the charge conversion to electric fields, the application of a separate pump electric field results in a detection sensitivity as low as 1.1(V/cm)/ Hz , with a near-diffraction limited spatial resolution and tunable control of the sensor dynamic range. In addition, we show both incoherent and coherent heterodyne detection, allowing measurements of either unknown random fields or synchronized fields with higher sensitivities. Finally, we demonstrate in-plane vector measurements of the electric field by combining orthogonal pump electric fields. Overall, this work establishes charge-based measurements as highly relevant for solid-state defect sensing.

Wolfowicz, Gary↗

Inferred UV fluence focal-spot profiles from soft x-ray pinhole-camera measurements on OMEGA

A method was developed with laser-irradiated Au planar foils to characterize the focal spot of UV laser beams on target at full energy from soft x-ray emission. A pinhole camera with a back-thinned charge-coupled–device detector and filtration with thin Be and Al foil filters provides images of the x-ray emission at photon energies <2 keV. This method requires a careful measurement of the relation between the applied UV fluence and the x-ray signal, which can be described by a power-law dependence. The measured exponent γ ~ 2 provides a dynamic range of ~25 for the inferred UV fluence. UV fluence profiles of selected beams were measured for 100-ps and 1-ns laser pulses and were compared to directly measured profiles from an UV equivalent-target-plane diagnostic. The inferred spot size and super-Gaussian order from the x-ray technique agree within several percent with the values measured with the direct UV measurements.

47 OTHER INSTRUMENTATION↗

Inorganic vacancy-ordered perovskite Cs 2 SnCl 6 :Bi/GaN heterojunction photodiode for narrowband, visible-blind UV detection

In this work, a heterojunction photodiode was fabricated from Bi doped Cs 2 SnCl 6 nanoparticles (Cs 2 SnCl 6 :Bi NPs) spin-coated on an epitaxially grown GaN substrate. With the back illumination configuration, the heterojunction photodiode demonstrated excellent narrow-band UV sensing capability with a full wavelength of half maximum of 18 nm and a maximum detectivity of 1.2 × 10 12 jones, which is promising for biomedical applications. In addition to the excellent narrow band UV sensitivity, the device also demonstrated a large linear dynamic range of 71 decibels (dB) and a fast photoresponse speed (a rise time of 0.75 μs and a fall time of 0.91 μs). The excellent performance is attributed to excellent carrier separation efficiency at the heterojunction interface and improved carrier collection efficiency through the multi-walled carbon nanotube (MWCNT) network. All the above advantages are of great importance for commercial deployment of perovskite-based photodetectors.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MPRAD: A Monte Carlo and ray-tracing code for the proton radiography in high-energy-density plasma experiments

Proton radiography is used in various high-energy-density (HED) plasma experiments. In this paper, we describe a Monte Carlo and raytracing simulation tool called multimegaelectronvolt proton radiography (MPRAD) that can be used for modeling the deflection of proton beams in arbitrary three dimensional electromagnetic fields as well as the diffusion of the proton beams by Coulomb scattering and stopping power. Specifically, the Coulomb scattering and stopping power models in cold matter and fully ionized plasma are combined using interpolation. We discuss the application of MPRAD in a few setups relevant to HED plasma experiments where the plasma density can play a role in diffusing the proton beams and affecting the prediction and interpretation of the proton images. It is shown how the diffusion due to plasma density can affect the resolution and dynamical range of the proton radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The five line-of-sight neutron time-of-flight (nToF) suite on the National Ignition Facility (NIF)

Measurement of the neutron spectrum from inertial confinement fusion implosions is one of the primary diagnostics of implosion performance. Analysis of the spectrum gives access to quantities such as neutron yield, hot-spot velocity, apparent ion temperature, and compressed fuel ρr through measurement of the down-scatter ratio. On the National Ignition Facility, the neutron time-of-flight suite has been upgraded to include five independent, collimated lines of sight, each comprising a high dynamic range bibenzyl/diphenylacetylene-stilbene scintillator [R. Hatarik et al., Plasma Fusion Res. 9, 4404104 (2014)] and high-speed fused silica Cherenkov detectors [A. S. Moore et al., Rev. Sci. Instrum. 89, 10I120 (2018)].

Moore, A. S. (ORCID:0000000221258882)↗

Comparing the shock sensitivity of insensitive energetic materials

We present a tabletop method to study the shock sensitivity of plastic-bonded explosives that are considered shock insensitive using high dynamic range optical emission spectroscopy with laser-launched km/s flyer plate impacts (2, 3, and 4 km/s), which measures the spectral radiance (the emission spectrum vs a calibrated intensity standard) every 0.8 ns in the nanosecond and microsecond regimes. The explosives were TATB (1,3,5 trinitro, 2,4,6 triamino benzene), FOX-7 (1,1-diamino-2,2-dinitroethylene), LLM-105 (2,6-diamino-3,5-dinitropyrazine-1-oxide), and NTO (nitrotriazolone), all with 20% Sylgard 182 binder. Time resolving emission from shocked explosives produces a unique fingerprint at each shock pressure, and the emission temporal profile can be used to understand each material's shock response and the underlying mechanisms within the framework of the well-known shock ignition and growth models. Ignition was characterized by the emission intensity during nanosecond hot spot ignition. The growth process, which occurs after the shock has unloaded, was characterized by the time derivative of microsecond emission intensity. Singular-value decomposition was used to determine a characteristic spectral radiance over the entire time range, and this radiance was fit to a graybody model to determine a characteristic temperature Tc. Even though these insensitive explosives have similar shock sensitivities, our method can clearly distinguish their shock response. FOX-7 and NTO were the most sensitive, with FOX-7 having the greatest shock ignition sensitivity, growth rate, and Tc. LLM-105 was much less sensitive than FOX-7 and NTO, and TATB consistently showed the lowest sensitivity by any measure.

Akhtar, Meysam (ORCID:0000000243897837)↗

CHESS: The future direct geometry spectrometer at the second target station

CHESS, chopper spectrometer examining small samples, is a planned direct geometry neutron chopper spectrometer designed to detect and analyze weak signals intrinsic to small cross sections (e.g., small mass, small magnetic moments, or neutron absorbing materials) in powders, liquids, and crystals. CHESS is optimized to enable transformative investigations of quantum materials, spin liquids, thermoelectrics, battery materials, and liquids. The broad dynamic range of the instrument is also well suited to study relaxation processes and excitations in soft and biological matter. The 15 Hz repetition rate of the Second Target Station at the Spallation Neutron Source enables the use of multiple incident energies within a single source pulse, greatly expanding the information gained in a single measurement. Furthermore, the high flux grants an enhanced capability for polarization analysis. This enables the separation of nuclear from magnetic scattering or coherent from incoherent scattering in hydrogenous materials over a large range of energy and momentum transfer. This paper presents optimizations and technical solutions to address the key requirements envisioned in the science case and the anticipated uses of this instrument.

47 OTHER INSTRUMENTATION↗

Bias-free terahertz generation from a silicon-compatible photoconductive emitter operating at telecommunication wavelengths

Here, we present a telecommunication-compatible bias-free photoconductive terahertz emitter composed of a bilayer InAs structure directly grown on a high-resistivity silicon substrate. The bilayer InAs structure includes p + -doped and undoped InAs layers, inducing a strong built-in electric field that enables terahertz generation without requiring any external bias voltage. A large-area plasmonic nanoantenna array is used to enhance and confine optical generation inside the photoconductive region with the highest built-in electric field, leading to the generation of a strong ultrafast photocurrent and broadband terahertz radiation. Thanks to a higher terahertz transmission through the silicon substrate and a shorter carrier lifetime in the InAs layers grown on silicon, higher signal-to-noise ratios are achieved at high terahertz frequencies compared with previously demonstrated bias-free terahertz emitters realized on GaAs. In addition to compatibility with silicon integrated optoelectronic platforms, the presented bias-free photoconductive emitter provides more than a 6 THz radiation bandwidth with more than 100 dB dynamic range when used in a terahertz time-domain spectroscopy system.

42 ENGINEERING↗

Characterization of the hardened single line of sight camera at the National Ignition Facility

The hardened single line of sight camera has been recently characterized in preparation for its deployment on the National Ignition Facility. The latest creation based on the pulse-dilation technology leads to many new features and improvements over the previous-generation cameras to provide better quality measurements of inertial confinement fusion experiments, including during high neutron yield implosions. Here, we present the characterization data that illustrate the main performance features of this instrument, such as extended dynamic range and adjustable internal magnification, leading to improved spatial resolution.

Trosseille, C. (ORCID:0000000289430482)↗

X-ray-imaging spectrometer (XRIS) for studies of residual kinetic energy and low-mode asymmetries in inertial confinement fusion implosions at OMEGA (invited)

A system of x-ray imaging spectrometer (XRIS) has been implemented at the OMEGA Laser Facility and is capable of spatially and spectrally resolving x-ray self-emission from 5 to 40 keV. The system consists of three independent imagers with nearly orthogonal lines of sight for 3D reconstructions of the x-ray emission region. The distinct advantage of the XRIS system is its large dynamic range, which is enabled by the use of tantalum apertures with radii ranging from 50 μm to 1 mm, magnifications of 4 to 35×, and image plates with any filtration level. In addition, XRIS is capable of recording 1–100’s images along a single line of sight, facilitating advanced statistical inference on the detailed structure of the x-ray emitting regions. Properties such as P0 and P2 of an implosion are measured to 1% and 10% precision, respectively. Furthermore, T e can be determined with 5% accuracy.

Adrian, P. J.↗

Measurements of fusion reaction history in inertially confined burning plasmas

Direct evidence of inertially confined fusion ignition appears in the abrupt temperature increase and consequent rapid increase in the thermonuclear burn rate as seen in the reaction history. The Gamma Reaction History (GRH) and Gas Cherenkov Detector (GCD) diagnostics are γ-based Cherenkov detectors that provide high quality measurements of deuterium–tritium fusion γ ray production and are, thus, capable of monitoring the thermonuclear burn rate. Temporal shifts in both peak burn time and burn width have been observed during recent high-yield shots (yields greater than 1017 neutrons) and are essential diagnostic signatures of the ignition process. While the current GRH and GCD detectors are fast enough to sense the changes of reaction history due to alpha heating, they do not have enough dynamic range to capture the onset of alpha heating. The next generation of instrumentation, GRH-15m, is proposed to increase the yield-rate coverage to measure the onset of alpha-heating.

42 ENGINEERING↗