Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron probe data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Study plasma interactions in the auroral ionosphere

Analyzed data from rocket flight, 29.007UE is presented. In a discrete electron arc the measured upward moving electrons are well accounted for by secondaries produced in collisional scattering of the measured downcoming electrons. No collective mechanisms need to invoke. The low energy downcoming electrons are accounted for by thermal plasma accelerated through a potential drop of a few kV that specularly reflects upward-moving lower energy electrons. No low altitude collective effects need to invoke in the arc. Simultaneous measurements of electric field by double probes on 29.007 and the Chatanika Radar allow one to infer that there are upward drifting ions above the discrete electron arc, and there is a westward neutral wind in the discrete arc. Two rocket payloads were built to investigate plasma effects in the pulsating aurora.

Anderson, H. R.↗

Characterizing Surfaces of the Wide Bandgap Semiconductor Ilmenite with Scanning Probe Microcopies

Ilmenite (FeTiO3) is a wide bandgap semiconductor with an energy gap of about 2.5eV. Initial radiation studies indicate that ilmenite has properties suited for radiation tolerant applications, as well as a variety of other electronic applications. Two scanning probe microscopy methods have been used to characterize the surface of samples taken from Czochralski grown single crystals. The two methods, atomic force microscopy (AFM) and scanning tunneling microscopy (STM), are based on different physical principles and therefore provide different information about the samples. AFM provides a direct, three-dimensional image of the surface of the samples, while STM give a convolution of topographic and electronic properties of the surface. We will discuss the differences between the methods and present preliminary data of each method for ilmenite samples.

Wilkins, R.↗

Water-Rock Interactions in Outer Solar System Bodies: Evidence from the Coordinated Analysis of Interplanetary Dust

NASA has an ongoing program of collecting interplanetary dust particles (IDPs) in the stratosphere using high altitude research aircraft. The collected IDPs are derived from asteroids and comets and here we report studies of a subset of hydrated IDPs rich in carbonaceous matter that are proposed to have a cometary origin. Our studies are aimed at understanding the evolution of oxygen reservoirs in the Solar System and their interaction with cometary minerals and organic matter. The small size (<20 μm) and fragility of these IDPs present a number of analytical challenges. We have pioneered techniques for performing chemical, mineralogical, isotopic, and spectroscopic measurements on the same sample in a carefully coordinated sequence. Coordinated analyses of nanogram-size samples is made possible by several delicate sample preparation techniques. To avoid organic contamination, we embed IDPs in elemental sulfur and use ultramicrotomy to partly section the particles (the first few micrometers). Multiple thin sections (50-70 nm thick) are placed on different substrates depending on the analysis technique. We use a JEOL 2500SE scanning, transmission electron microscope (STEM) to determine the mineralogy, microstructure, and elemental compositions of constituent minerals in the thin sections through a combination of high resolution imaging, electron diffraction, quantitative energy-dispersive x-ray mapping, and electron energy-loss spectroscopy. Following the STEM analyses, we use a NanoSIMS 50L for high spatial resolution isotopic measurements of H, C, N, and O to search for presolar grains and to understand the origin of the indigenous organic matter. The isotopic analyses are performed on the same sections analyzed in the STEM in order to correlate isotopic properties with the elemental and mineralogical data. We reserve other thin sections for non-destructive analyses utilizing synchrotron-based techniques including Fourier-transform infrared (FTIR) micro-spectroscopy and X-ray absorption near-edge structure (XANES) analyses, especially for functional group analysis of organic matter in the particles. The remainder of the IDP is extracted from the sulfur bead that was used for microtomy and is pressed into Au foil for quantitative analysis (including light elements) using a JEOL 8530F field emission electron probe microanalyzer (EPMA). After the EPMA measurements, high precision oxygen isotopic analyses are obtained using Cameca IMS1270/1290 instruments at UCLA. The hydrated IDPs in this study are dominated by saponitic clays, with minor magnetite, carbonate and abundant organic matter. The remarkable oxygen isotopic compositions, high carbon contents, and the abundance of isotopically anomalous organic matter, together suggest that the high carbon, hydrated IDPs are derived from primitive sources not yet represented in meteorite collections such as outer main belt P- and D-type asteroids or comets.

Keller, Lindsay P.↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

Opto-Electronic Characterization CdTe Solar Cells from TCO to Back Contact with Nano-Scale CL Probe

We used cathodoluminescence (CL) (spectrum-per-pixel) imaging on beveled CdTe solar cell sections to investigate the opto-electronic properties of these devices from the TCO to the back contact. We used a nano-scale CL probe to resolve luminescence from grain boundary (GB) and grain interior (GI) locations near the CdS/CdTe interface where the grains are very small. As-deposited, CdCl2-treated, Cu-treated, and (CdCl2+Cu)-treated cells were analyzed. Color-coded CL spectrum imaging maps on bevels illustrate the distribution of the T=6 K luminescence transitions through the depth of devices with unprecedented spatial resolution. The CL at the GBs and GIs is shown to vary significantly from the front to the back of devices and is a sensitive function of processing. Supporting D-SIMS depth profile, TRPL lifetime, and C-V measurements are used to link the CL data to the J-V performance of devices.

14 SOLAR ENERGY↗

Ultrafast Triplet Pair Separation and Triplet Trapping following Singlet Fission in Amorphous Pentacene Films

In this work, ultrafast infrared and electronic spectroscopy are used to examine the dynamics of triplet pair separation following singlet fission in amorphous and crystalline films of the model singlet fission chromophore, 6,13-bis(triisopropylsilylethynyl)pentacene (TIPS-Pn). Direct probing of correlated triplet pair intermediates through their unique vibrational frequencies, infrared electronic transitions, and indirectly through their visible triplet absorptions reveals that triplet pair separation occurs on similar picosecond timescales in both amorphous and crystalline films despite their markedly different average intermolecular coupling strengths. Although triplet pair separation occurs on similar timescales in both environments, measurements of diffusion-controlled triplet-triplet annihilation reveal that the diffusivity of triplet excited states is an order of magnitude lower in amorphous films. The data reveal the presence of sparse triplet traps in the amorphous environment that inhibit the transport of triplet excitons in comparison to crystalline films. These observations inform recent efforts to develop disordered and polymeric singlet fission sensitizers that contain amorphous regions. In particular, the data suggest that it may be possible to nanostructure amorphous or polymeric singlet fission sensitizers to allow ultrafast triplet pair separation and harvesting in photovoltaic and light emitting applications despite their low triplet exciton diffusivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast heat transfer in single palladium nanocrystals seen with an X-ray free-electron laser

We report transient highly strained structural states in individual palladium (Pd) nanocrystals, electronically heated using an optical laser, which precede their uniform thermal expansion. Using an X-ray free-electron laser probe, the evolution of individual 111 Bragg peaks is measured as a function of delay time at various laser fluences. Above a laser fluence threshold at a sufficient pump-probe delay, the Bragg peak splits into multiple peaks, indicating heterogeneous strain, before returning to a single peak, corresponding to even heat distribution throughout the lattice expanded crystal. Our findings are supported by a lattice displacement and strain model of a single nanocrystal at different delay times, which agrees with the experimental data. Our observations have implications for understanding femtosecond laser interactions with metals and the potential photo-catalytic performance of Pd.

36 MATERIALS SCIENCE↗

Communication: Coherences observed in vivo in photosynthetic bacteria using two-dimensional electronic spectroscopy

Energy transfer through large disordered antenna networks in photosynthetic organisms can occur with a quantum efficiency of nearly 100%. This energy transfer is facilitated by the electronic structure of the photosynthetic antennae as well as interactions between electronic states and the surrounding environment. Coherences in time-domain spectroscopy provide a fine probe of how a system interacts with its surroundings. In two-dimensional electronic spectroscopy, coherences can appear on both the ground and excited state surfaces revealing detailed information regarding electronic structure, system-bath coupling, energy transfer, and energetic coupling in complex chemical systems. Numerous studies have revealed coherences in isolated photosynthetic pigment-protein complexes, but these coherences have not been observed in vivo due to the small amplitude of these signals and the intense scatter from whole cells. Here, we present data acquired using ultrafast video-acquisition gradient-assisted photon echo spectroscopy to observe quantum beating signals from coherences in vivo. Experiments were conducted on isolated light harvesting complex II (LH2) from Rhodobacter sphaeroides, whole cells of R. sphaeroides, and whole cells of R. sphaeroides grown in 30% deuterated media. A vibronic coherence was observed following laser excitation at ambient temperature between the B850 and the B850{sup ∗} states of LH2 in each of the 3 samples with a lifetime of ∼40-60 fs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrostatic potential mapping at ferroelectric domain walls by low-temperature photoemission electron microscopy

Low-temperature X-ray photoemission electron microscopy (X-PEEM) is used to measure the electric potential at domain walls in improper ferroelectric Er 0.99 Ca 0.01 MnO 3 . Here, by combining X-PEEM with scanning probe microscopy and theory, we develop a model that relates the detected X-PEEM contrast to the emergence of uncompensated bound charges, explaining the image formation based on intrinsic electronic domain-wall properties. In contrast to previously applied low-temperature electrostatic force microscopy (EFM), X-PEEM readily distinguishes between positive and negative bound charges at domain walls. Finally, our study introduces an X-PEEM-based approach for low-temperature electrostatic potential mapping, facilitating nanoscale spatial resolution and data acquisition times on the order of 0.1-1 s.

36 MATERIALS SCIENCE↗

Nuclear structure functions at a future electron-ion collider

The quantitative knowledge of heavy nuclei's partonic structure is currently limited to rather large values of momentum fraction x { robust experimental constraints below x ~ 10 -2 at low resolution scale Q 2 are particularly scarce. This is in sharp contrast to the free proton's structure which has been probed in deep inelastic scattering (DIS) measurements down to x ~ 10 -5 at perturbative resolution scales. The construction of an Electron-Ion Collider (EIC) with a possibility to operate with a wide variety of nuclei, will allow one to explore the low-x region in much greater detail. In the present paper we simulate the extraction of the nuclear structure functions from measurements of inclusive and charm reduced cross sections at an EIC. The potential constraints are studied by analyzing simulated data directly in a next-to-leading order global fit of nuclear parton distribution functions based on the recent EPPS16 analysis. A special emphasis is placed on studying the impact an EIC would have on extracting the nuclear gluon PDF, the partonic component most prone to non-linear e ects at low Q 2 . In comparison to the current knowledge, we find that the gluon PDF can be measured at an EIC with significantly reduced uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electronic Production Control System News Note

The CMD subprogram develops and deploys multi-application weapon component manufacturing capabilities needed to replace sunset technologies, upgrade existing technologies, and introduce new technologies that support the nuclear weapons stockpile. Sandia National Laboratories (SNL) is currently developing an Electronic Production Control System (EPCS) for ASIC production in the back end of line (BEOL) flow. A pre-production version of EPCS has been released and is operating as intended. We are currently processing all ASIC products, including CVV validation ASICs. The BEOL flow includes wafer probe, packaging, quality inspection, initial electrical test, dynamic burn-in, final electrical test, quality inspection, final visual inspection, radiation testing, SNL acceptance, DOE SSO acceptance, and qualification testing steps. EPCS will execute this production workflow (initiate, control, and electronically track each product); it will implement defect prevention strategies; it will create an electronic inventory control system that is accountable for all ASIC material from inception to delivery; it will electronically collect and store any and all required quality evidence and most of the electronic BEOL data; and it will create a management reporting module with production statistics and timelines. The defect prevention strategies include the use of 2D marks on our ASICs with 2D scanners so that there will be no manual entry of part numbers (scanners), will not allow testing the wrong parts in Test and Burn-in. Other defect prevention strategies will negate the possibility of neither using the wrong test or burn-in program for any part nor the use of BEOL machines or boards that are out of calibration. In summary, EPCS is being implemented and it will greatly improve the product acceptance through full electronic data collection and quality control and defect prevention through bar codes, scanners, tracking training of personnel, and tracking tool availability.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Middle atmosphere measurements of small-scale electron density irregularities and ion properties during the MAC/Epsilon campaign

Rocket payloads designed to measure small scale electron density irregularities and ion properties in the middle atmosphere were flown with each of the three main salvos of the MAC/Epsilon campaign conducted at the Andoya Rocket Range, Norway, during October to November 1987. Fixed bias, hemispheric nose tip probes measured small scale electron density irregularities, indicative of neutral air turbulence, during the rocket's ascent; and subsequently, parachute-borne Gerdien condensers measured the region's polar electrical conductivity, ion mobility and density. One rocket was launched during daylight (October 15, 1052:20 UT), and the other two launches occurred at night (October 21, 2134 UT: November 12, 0021:40 UT) under moderately disturbed conditions which enhanced the detection and measurement of turbulence structures. A preliminary analysis of the real time data displays indicates the presence of small scale electron density irregularities in the altitude range of 60 to 90 km. Ongoing data reduction will determine turbulence parameters and also the region's electrical properties below 90 km.

Blood, S. P.↗

Determination of plasma density from data on the ion current to cylindrical and planar probes

To improve probe methods of plasma diagnostics, special probe measurements were performed and numerical models describing ion transport to a probe with allowance for collisions were developed. The current–voltage characteristics of cylindrical and planar probes were measured in an RF capacitive discharge in argon at a frequency of 81 MHz and plasma densities of 10{sup 10}–10{sup 11} cm{sup –3}, typical of modern RF reactors. 1D and 2D numerical models based on the particle-in-cell method with Monte Carlo collisions for simulating ion motion and the Boltzmann equilibrium for electrons are developed to describe current collection by a probe. The models were used to find the plasma density from the ion part of the current–voltage characteristic, study the effect of ion collisions, and verify simplified approaches to determining the plasma density. A 1D hydrodynamic model of the ion current to a cylindrical probe with allowance for ion collisions is proposed. For a planar probe, a method to determine the plasma density from the averaged numerical results is developed. A comparative analysis of different approaches to calculating the plasma density from the ion current to a probe is performed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Differentiating Thermal Conductances at Semiconductor Nanocrystal/Ligand and Ligand/Solvent Interfaces in Colloidal Suspensions

Infrared-pump, electronic-probe (IPEP) spectroscopy is used to measure heat flow into and out of CdSe nanocrystals suspended in an organic solvent, where the surface ligands are initially excited with an infrared pump pulse. Subsequently, the heat is transferred from the excited ligands to the nanocrystals and in parallel to the solvent. Parallel heat transfer in opposite directions uniquely enables us to differentiate the thermal conductances at the nanocrystal/ligand and ligand/solvent interfaces. Using a novel solution to the heat diffusion equation, we fit the IPEP data to find that the nanocrystal/ligand conductances range from 88 to 135 MW m –2 K –1 and are approximately 1 order of magnitude higher than the ligand/solvent conductances, which range from 7 to 26 MW m –2 K –1 . Transient nonequilibrium molecular dynamics (MD) simulations of nanocrystal suspensions agree with IPEP data and show that ligands bound to the nanocrystal by bidentate bonds have more than twice the per-ligand conductance as those bound by monodentate bonds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectrum and Structure of Excited Baryons with CLAS*

In this contribution I discuss recent results in light quark baryon spectroscopy involving CLAS data and higher level analysis results from the partial wave analysis by the Bonn-Gatchina group. New baryon states were discovered largely based on the open strangeness production channels gamma p --> K^+Lambda and gamma p --> K^+Sigma^0. The data illustrate the great potential of the kaon-hyperon channel in the discovery of higher mass baryon resonances in s-channel production. Other channels with discovery potential, such as gamma p --> p omega and gamma p --> phi p are also discussed. In the second part I will demonstrate on data the sensitivity of meson electroproduction to expose the active degrees of freedom underlying resonance transitions as a function of the probed distance scale. For several of the prominent excited states in the lower mass range the short distance behavior is described by a core of three dressed-quarks with running quark mass, and meson-baryon contributions make up significant parts of the excitation strength at large distances. Finally, I give an outlook of baryon resonance physics at the 12 GeV CEBAF electron accelerator.

Burkert, Volker D.↗

The Mariner 10 radio occultation measurements of the ionosphere of Venus

Data from the Mariner 10 radio occultation experiment have been utilized to determine the vertical electron density distribution in the ionosphere of Venus. The ingress measurements, which were made at latitude 1.3 deg N on the nightside of the planet, show two distinct layers. The main layer was located at 142 km altitude and had a peak density of 9000 electrons per cu cm. A secondary layer with a peak density of 7000/cu cm was detected at 124 km altitude. During egress, the ionosphere was probed at latitude 56.0 deg S on the dayside of Venus. The solar zenith angle in this region was 67.0 deg. The dayside ionosphere consisted of a main layer with a peak density of 290,000 per cu cm at 142 km altitude and several minor layers. At the top of the dayside ionosphere, the measurements showed an abrupt drop in the density from 2000 per cu cm at 335 km altitude to below the level of detectability, i.e., less than 200 per cu cm, at 360 km altitude. This abrupt density change may be the ionopause where the solar wind plasma interacts with the ionized components of the atmosphere.

Fjeldbo, G.↗

Satellite measurements of ionic concentrations applied to low altitude incoherent scatter interpretations

The determination of ion and electron temperatures and electron density from incoherent scatter radar data has in the past involved assumptions concerning the ionospheric composition below 250 km. Using a very large data base of measurements of O(+), O2(+), NO(+), and N2(+) made by the Atmosphere Explorer C satellite, a model has been developed of the ionic concentration between 130 and 300 km as a function of solar zenith angle. As the effect of the new model is to increase the radar determinations of the temperature, this may explain previous discrepancies between Langmuir probe and incoherent scatter temperatures, where the comparisons have been made at these low altitudes

Torr, M. R.↗

DE/ISIS conjunction comparisons of high-latitude electron density features

This paper presents a comparison between the ISIS-1 and -2 topside sounder measurements of electron number density, N(e), with the in situ ion and N(e) measurements by the Langmuir probe aboard the Dynamics Explorer 2 (DE 2) during four high-latitude ISIS/DE magnetic field-aligned conjunctions. The ISIS-derived N(e) values, even at the greatest distance from the sounder, were found to agree with the Langmuir probe measurements to within about 30 percent over a density range of more than two decades on three of the four comparisons; the fourth comparison which included data with strong N(e) irregularities, showed a difference of 60 percent.

Hoegy, Walter R.↗