Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Traveling wakefield tube: THz source powered by nonrelativistic electron beam

High peak power, tunable, narrowband terahertz emitters are becoming sought after given their portability, efficiency, and ability to be deployed in the field for industrial, medical, and military applications. The use of accelerator systems producing THz frequencies via Cherenkov radiation, generated by passing an electron beam through a slow-wave wakefield structure, is a promising method to meet future THz requirements. To date, efforts have been dedicated to analysis and design of sources utilizing laser seeded bunched electron beam drivers with relativistic energies beyond 5 MeV. Presented here is a wakefield THz generation scheme based on passing a long quasi-dc nonrelativistic beam (200 keV) through a dielectric loaded travelling wave structure. Reduced energy allows for compactness and portability of the accelerator as the size and weight of the dielectric slow wave structure is vanishingly small compared to the accelerator unit. The presented scheme can serve as a tunable high peak power THz source operated between 0.4-1.6 THz and produces power gain by a factor of five with an average efficiency of 6.8%

43 PARTICLE ACCELERATORS↗

Effect of electron cyclotron resonance ion source frequency tuning on ion beam intensity and quality at Department of Physics, University of Jyvaeskylae

Ion beam intensity and quality have a crucial effect on the operation efficiency of the accelerator facilities. This paper presents the investigations on the ion beam intensity and quality after the mass separation performed with the Department of Physics, University of Jyvaeskylae 14 GHz electron cyclotron resonance ion source by sweeping the microwave in the 14.05-14.13 GHz range. In many cases a clear variation in the ion beam intensity and quality as a function of the frequency was observed. The effect of frequency tuning increased with the charge state. In addition, clear changes in the beam structure seen with the beam viewer were observed. The results confirmed that frequency tuning can have a remarkable effect on ion beam intensity and quality especially in the case of highly charged ion beams. The examples presented here represent the typical charge state behavior observed during the measurements.

43 PARTICLE ACCELERATORS↗

The electron cyclotron resonance ion source with arc-shaped coils concept (invited)

The main limitation to further improve the performance of ECR ion sources is set by the magnet technology related to the multipole magnet field used for the closed minimum-B structure. The JYFL ion source group has sought different approaches to improve the strength of the minimum-B structure required for the production of highly charged ion beams. It was found out that such a configuration can be realized with arc shaped coils. The first prototype, electron cyclotron resonance ion source with arc-shaped coils (ARC-ECRIS), was constructed and tested at JYFL in 2006. It was confirmed that such an ion source can be used for the production of highly charged ion beams. Regardless of several cost-driven compromises such as extraction mirror ratio of 1.05-1.2, microwave frequency of 6.4 GHz, and beam line with limited capacity, Ar{sup 4+} beam intensity of up to 2 {mu}A was measured. Subsequent design study has shown that the ARC-ECRIS operating at the microwave frequency above 40 GHz could be constructed. This specific design would be based on NbTi-wires and it fulfills the experimental magnetic field scaling laws. In this article, the ARC-ECRIS concept and its potential applications will be described.

43 PARTICLE ACCELERATORS↗

The compact electron cyclotron resonance ion source KeiGM for the carbon ion therapy facility at Gunma University

A high-energy carbon-ion radiotherapy facility is under construction at Gunma University Heavy Ion Medical Centre (GHMC). Its design was based on a study of the heavy ion radiotherapy at the National Institute of Radiological Sciences (NIRS) in order to reduce the size and construction cost of the facility. A compact electron cyclotron resonance ion source (ECRIS) for Gunma University, called KeiGM, was installed in 2008. It is almost a copy of the prototype ECRIS Kei2 which was developed by NIRS; meanwhile this prototype produced over 1 e mA of C{sup 4+} using C{sub 2}H{sub 2} gas (660 W and 40 kV). The beam intensity of C{sup 4+} was 600 e {mu}A with CH{sub 4} gas (250 W and 30 kV). The beam intensity satisfies the required value of 300 e {mu}A.

43 PARTICLE ACCELERATORS↗

Experimental results of an electron cyclotron resonance oxygen source and a low energy beam transport system for 1 MeV integral split ring radio frequency quadruple accelerator upgrade project

To meet the requirements of developing separated function radio frequency quadruple (rfq) and upgrading the 1 MeV integral split ring rfq accelerator, an electron cyclotron resonance O{sup +} ion source and low energy beam transport (LEBT) system have been developed. Using two Einzel lenses to focus the beam, more than 6 mA O{sup +} peak beam current with energy of 22 keV can be easily obtained at the end of LEBT when the duty faction is at 1/6. The normalized root-mean-square emittance of 90% of the beam is about 0.12{pi} mm mrad. By changing the focusing power of lenses, the beam waist can be shifted from 80 mm before the beam diaphragm 2 to 80 mm after it. The experimental results will be presented in this article.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ELECTRON-CAPTURE SUPERNOVAE AS SOURCES OF {sup 60}Fe

We investigate the nucleosynthesis of the radionuclide {sup 60}Fe in electron-capture supernovae (ECSNe). The nucleosynthetic results are based on a self-consistent, two-dimensional simulation of an ECSN as well as models in which the densities are systematically increased by some factors (low-entropy models). {sup 60}Fe is found to be appreciably made in neutron-rich ejecta during the nuclear quasi-equilibrium phase with greater amounts being produced in the lower-entropy models. Our results, combining them with the yields of core-collapse supernovae in the literature, suggest that ECSNe account for at least 4%-30% of live {sup 60}Fe in the Milky Way. ECSNe co-produce neutron-rich isotopes, {sup 48}Ca, {sup 50}Ti, {sup 54}Cr, some light trans-iron elements, and possibly weak r-process elements including some radionuclides such as {sup 93}Zr, {sup 99}Tc, and {sup 107}Pd, whose association with {sup 60}Fe might have been imprinted in primitive meteorites or in the deep ocean crust on the Earth.

79 ASTRONOMY AND ASTROPHYSICS↗

An overview on TRIUMF's developments on ion source for radioactive beams (invited)

The ISAC facility at TRIUMF utilizes up to 100 {mu}A from the 500 MeV H{sup -} cyclotron to produce the radioactive ion beam (RIB) using the isotopic separation on line method. The ISAC-I facility comprised the RIB production target stations, the mass separator, and the beam delivery to low energy area and to a room temperature linear accelerator composed of a four-rod radio frequency quadrupole and an interdigital H-type structure drift tube LINAC. ISAC-I linear accelerator can provide beam from A=3 to 30 amu with an energy range from 0.15 to 1.5 A MeV. Since the beginning of operations target development program has been to increase proton beam currents on targets. Now we routinely operate our target at 50-85 {mu}A and recently we have operated our target at 100 {mu}A. Other developments are in place to add other ion sources, laser, force electron beam induced are discharge and electron cyclotron resonance ion source to the actual surface ion source. The last two five year plans were mainly devoted to the construction of a heavy ion superconducting LINAC (ISAC-II) that will upgrade the mass and the energy range from 30 to 150 and from 1.5 to 6.5 A MeV, respectively. The intermediate stage E{<=}4.2 A MeV is already completed and commissioned; three experiments using {sup 11}Li, {sup 9}Li, and {sup 29}Na have been completed this summer.

43 PARTICLE ACCELERATORS↗

Multiturn injection of EBIS ions in booster

Ions from EBIS are injected into Booster after acceleration by an RFQ and a Linac. The velocity of the ions at Booster injection is c{beta} where c is the velocity of light and (1) {beta} = 0.0655. The kinetic energy is (2) W = mc{sup 2}({gamma}-1) where m is the ion mass and (3) {gamma} = (1-{beta}{sup 2}){sup -1/2}. Putting in numbers one gets a kinetic energy of approximately 2 MeV per nucleon for each ion. The revolution period at injection is 10.276 {micro}s. The ions in the EBIS trap are delivered in a beam pulse that ranges from 10 to 40 {micro}s in length. This amounts to 1 to 4 turns around the machine. The transverse emittance (un-normalized) of EBIS beams just prior to injection into Booster is 11{pi} mm milliradians in both planes. This is an order of magnitude larger than the nominal 1{pi} mm milliradians for Tandem beams. Injection proceeds by means of an electrostatic inflector in the C3 straight section and four programmable injection dipoles in the C1, C3, C7, and D1 straights. These devices have been in use for many years for the injection of ions from Tandem as described in [1] and [2]. The inflector brings the incoming beam to the edge of the Booster acceptance and the dipoles produce a closed orbit bump that initially places the closed orbit near the septum at the in ector exit. During injection the orbit bump must be collapsed at a rate that keeps the injected beam from hitting the septum while continuing to allow beam to be injected into the machine acceptance. The process is discussed in [2] and [3]. There it is assumed that the injected beam moves with the closed orbit as the bump collapses. In the present report this is shown to be a valid approximation if the bump collapses sufficiently slowly. It is also shown that by judiciously choosing the horizontal tune and the initial distance of the closed orbit from the septum one can inject up to 4 turns of EBIS beams without loss on the septum. The reason for wanting to inject over a period of 4 rather than fewer turns is that this allows the beam to be distributed over a larger area of the Booster acceptance, thereby reducing the space charge force on the beam particles.

43 PARTICLE ACCELERATORS↗

Absolute energy calibration of FD by an electron linear accelerator for Telescope Array

The primary energy of the ultra-high energy cosmic rays(UHECR) are measured with the number of fluorescence photons which are detected with fluorescence detectors(FD) in the Telescope Array experiment(TA). Howevery since there is large uncertinty as 19% in the measurement of the energy scale, the most important theme is improvement of the energy calibration. The electron light source(ELS) is a small electron linear accelerator for new energy calibration. The ELS is located 100 m far from the FD station, and injects electron beam which is accelerated to 40 MeV energy into the sky. We can calibrate the FD energy scale by detection the air shower directly which is generated by the electron beam. The ELS was developed in KEK Japan, and moved to the TA site in March 2009. We started the beam operation in September 2010, in consequence we detected the air shower which was generated by electron beam in the air. The output kinetic energy of the electron beam was 41.1 MeV, we adjusted the output charge from 40 to 140 pC/pulse. We expect that we can improve the uncertinty of the energy scale to about 10% with the ELS, futhermore ELS will be a very useful apparatus for R and D of future UHECR observation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research Activities At The RCNP Cyclotron Facility

The Research Center for Nuclear Physics (RCNP) cyclotron cascade system has been operated to provide high quality beams for various experiments. In order to increase the physics research opportunities, the Azimuthally Varying Field (AVF) cyclotron facility was upgraded recently. A flat-topping system and an 18-GHz superconducting Electron Cyclotron Resonance (ECR) ion source were introduced to improve the beam's quality and intensity. A new beam line was installed to diagnose the characteristics of the beam to be injected into the ring cyclotron and to bypass the ring cyclotron and directly transport low energy beams from the AVF cyclotron to experimental halls. A separator is equipped to provide RI beams produced by fusion reactions at low energy and by projectile fragmentations at high energy. Development has continued to realize the designed performance of these systems.

43 PARTICLE ACCELERATORS↗

The development of a combined effects space simulation facility

An overview of the development of a facility to study the combined effects of the space environment on spacecraft is presented. The characterization of a magnetic filter plasma source and a low energy electron flood source for the simulation of the low Earth orbit plasma environment is discussed. Plasma diagnostics show that the magnetic filter plasma source provides streaming ion energies of approximately 5eV and can supply the appropriate density for LEO simulation. Additionally the low energy flood gun is shown to provide the appropriate density for LEO simulation as a function of altitude and solar activity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Methods for producing hydrogen using nanoparticle-catalyst mixtures

Provided are compositions for and methods of producing hydrogen. For example, the compositions comprise nanocrystals, a catalyst, a source of electrons, and an aqueous medium. The nanocrystals, catalyst, aqueous medium, and, optionally, the source of electrons are present as a mixture. The methods produce hydrogen by exposing the compositions to electromagnetic radiation (e.g., solar flux).

08 HYDROGEN↗

Hybrid quadrupole mass filter/quadrupole ion trap/time-of-flight-mass spectrometer for infrared multiple photon dissociation spectroscopy of mass-selected ions

We present a laboratory-constructed mass spectrometer optimized for recording infrared multiple photon dissociation (IRMPD) spectra of mass-selected ions using a benchtop tunable infrared optical parametric oscillator/amplifier (OPO/A). The instrument is equipped with two ionization sources, an electrospray ionization source, as well as an electron ionization source for troubleshooting. This hybrid mass spectrometer is composed of a quadrupole mass filter for mass selection, a reduced pressure ({approx}10{sup -5} Torr) quadrupole ion trap (QIT) for OPO irradiation, and a reflectron time-of-flight drift tube for detecting the remaining precursor and photofragment ions. A helium gas pulse is introduced into the QIT to temporarily increase the pressure and hence enhance the trapping efficiency of axially injected ions. After a brief pump-down delay, the compact ion cloud is subjected to the focused output from the continuous wave OPO. In a recent study, we implemented this setup in the study of protonated tryptophan, TrpH{sup +}, as well as collision-induced dissociation products of this protonated amino acid [W. K. Mino, Jr., K. Gulyuz, D. Wang, C. N. Stedwell, and N. C. Polfer, J. Phys. Chem. Lett. 2, 299 (2011)]. Here, we give a more detailed account on the figures of merit of such IRMPD experiments. The appreciable photodissociation yields in these measurements demonstrate that IRMPD spectroscopy of covalently bound ions can be routinely carried out using benchtop OPO setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High intensity production of high and medium charge state uranium and other heavy ion beams with VENUS

The next generation, superconducting electron cyclotron resonance (ECR) ion source VENUS (versatile ECR ion source for nuclear science) started operation with 28 GHz microwave heating in 2004. Since then it has produced world record ion beam intensities. For example, 2850 e {mu}A of O{sup 6+}, 200 e {mu}A of U{sup 33+} or U{sup 34+}, and in respect to high charge state ions, 1 e {mu}A of Ar{sup 18+}, 270 e {mu}A of Ar{sup 16+}, 28 e {mu}A of Xe{sup 35+}, and 4.9 e {mu}A of U{sup 47+} have been produced. A brief overview of the latest developments leading to these record intensities is given and the production of high intensity uranium beams is discussed in more detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron cyclotron resonance plasma photos

In order to observe and study systematically the plasma of electron cyclotron resonance (ECR) ion sources (ECRIS) we made a high number of high-resolution visible light plasma photos and movies in the ATOMKI ECRIS Laboratory. This required building the ECR ion source into an open ECR plasma device, temporarily. An 8MP digital camera was used to record photos of plasmas made from Ne, Ar, and Kr gases and from their mixtures. We studied and recorded the effect of ion source setting parameters (gas pressure, gas composition, magnetic field, and microwave power) to the shape, color, and structure of the plasma. The analysis of the photo series gave us many qualitative and numerous valuable physical information on the nature of ECR plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preparation of state purified beams of He, Ne, C, N, and O atoms

The production and guiding of ground state and metastable C, N, and O atoms in a two-meter-long, bent magnetic guide are described. Pure beams of metastable He({sup 3}S{sub 1}) and Ne({sup 3}P{sub 2}), and of ground state N({sup 4}S{sub 3/2}) and O({sup 3}P{sub 2}) are obtained using an Even-Lavie valve paired with a dielectric barrier discharge or electron bombardment source. Under these conditions no electronically excited C, N, or O atoms are observed at the exit of the guide. A general valve with electron impact excitation creates, in addition to ground state atoms, electronically excited C({sup 3}P{sub 2}; {sup 1}D{sub 2}) and N({sup 2}D{sub 5/2}; {sup 2}P{sub 3/2}) species. The two experimental conditions are complimentary, demonstrating the usefulness of a magnetic guide in crossed or merged beam experiments such as those described in Henson et al. [Science 338, 234 (2012)] and Jankunas et al. [J. Chem. Phys. 140, 244302 (2014)].

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a highly-sensitive Penning ionization electron spectrometer using the magnetic bottle effect

This paper reports on a highly-sensitive retarding-type electron spectrometer for a continuous source of electrons, in which the electron collection efficiency is increased by utilizing the magnetic bottle effect. This study demonstrates an application to Penning ionization electron spectroscopy using collisional ionization with metastable He*(2{sup 3}S) atoms. Technical details and performances of the instrument are presented. This spectrometer can be used for studies of functional molecules and assemblies, and exterior electron densities are expected to be selectively observed by the Penning ionization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗