Search NASA⌕ Search

SEARCH · Search NASA

Results for “environmental sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Development of a large-scale, outdoor, ground-based test capability for evaluating the effect of rain on airfoil lift

A large-scale, outdoor, ground-based test capability for acquiring aerodynamic data in a simulated rain environment was developed at the Langley Aircraft Landing Dynamics Facility (ALDF) to assess the effect of heavy rain on airfoil performance. The ALDF test carriage was modified to transport a 10-ft-chord NACA 64210 wing section along a 3000-ft track at full-scale aircraft approach speeds. An overhead rain simulation system was constructed along a 525-ft section of the track with the capability of producing simulated rain fields of 2, 10, 30, and 40 in/hr. The facility modifications, the aerodynamic testing and rain simulation capability, the design and calibration of the rain simulation system, and the operational procedures developed to minimize the effect of wind on the simulated rain field and aerodynamic data are described in detail. The data acquisition and reduction processes are also presented along with sample force data illustrating the environmental effects on data accuracy and repeatability for the 'rain-off' test condition.

Bezos, Gaudy M.↗

Terrain tracking for lander guidance using binary phase-only spatial filters

We demonstrate the use of binary phase-only spatial filters (BPOFs) for tracking target sites through a sequence of gray-scale terrain images. The filters are demonstrated in a closed loop guidance system for a laboratory lander mockup. Images of a 3D terrain board taken by the lander's video camera are preprocessed to produce binary intensity contour maps of a simulated planetary surface. A BPOF is made from a section of the current preprocessed image centered on the exact desired landing site. After the lander has descended to a lower altitude, the BPOF is correlated with a new image. The position of the correlation peak is used in making the next filter and to guide the lander so as to recenter the landing site in the camera's view. We present testbed results of the accuracy with which a site may be tracted from orbit to landing, and the maximum scale, translation, and rotation which can be tolerated between subsequent images. Application of the results to NASA's proposed Mars Rover Sample Return (MRSR) and Mars Environmental Survey (MESUR) missions is discussed.

Reid, Max B.↗

Planetary lander guidance using binary phase-only filters

We demonstrate the use of binary phase-only filters (BPOFs) in a closed loop guidance system for a laboratory lander mockup. Images of a 3-D terrain board taken by the lander's video camera are preprocessed to produce 128 x 128 binary intensity contour maps of the simulated planetary surface. A BPOF is made from a section of the current preprocessed image centered on the exact desired landing site. After the lander has descended to a lower altitude, the BPOF is correlated with a new image. The position of the correlation peak is used in making the next filter and to guide the lander so as to recenter the landing site in the camera's view. We present results of the accuracy with which a site may be tracked from orbit to landing, and the maximum scale, translation, and rotation which can be tolerated between subsequent images. The tolerable scale distortion is quite critical, as it determines the maximum filter update time available at a given descent rate. Application of the results to NASA's proposed Mars Rover Sample Return (MRSR) and Mars Environmental Survey (MESUR) missions is discussed. In both cases, electronic implementations of the algorithm may be sufficient to provide the required guidance system performance.

Reid, Max B.↗

Automated Test Systems for Toxic Vapor Detectors

The NASA Toxic Vapor Detection Laboratory (TVDL) at the Kennedy Space Center (KSC), Florida, has been using Personal Computer based Data Acquisition and Control Systems (PCDAS) for about nine years. These systems control the generation of toxic vapors of known concentrations under controlled conditions of temperature and humidity. The PCDAS also logs the test conditions and the test article responses in data files for analysis by standard spreadsheets or custom programs. The PCDAS was originally developed to perform standardized qualification and acceptance tests in a search for a commercial off-the-shelf (COTS) toxic vapor detector to replace the hydrazine detectors for the Space Shuttle launch pad. It has since become standard test equipment for the TVDL and is indispensable in producing calibration standards for the new hydrazine monitors at the 10 part per billion (ppb) level. The standard TVDL PCDAS can control two toxic vapor generators (TVG's) with three channels each and two flow/temperature/humidity (FIFH) controllers and it can record data from up to six toxic vapor detectors (TVD's) under test and can deliver flows from 5 to 50 liters per minute (L/m) at temperatures from near zero to 50 degrees Celsius (C) using an environmental chamber to maintain the sample temperature. The concentration range for toxic vapors depends on the permeation source installed in the TVG. The PCDAS can provide closed loop control of temperature and humidity to two sample vessels, typically one for zero gas and one for the standard gas. This is required at very low toxic vapor concentrations to minimize the time required to passivate the sample delivery system. Recently, there have been several requests for information about the PCDAS by other laboratories with similar needs, both on and off KSC. The purpose of this paper is to inform the toxic vapor detection community of the current status and planned upgrades to the automated testing of toxic vapor detectors at the Kennedy Space Center.

Mattson, C. B.↗

Automated Test Systems for Toxic Vapor Detectors

The NASA Toxic Vapor Detection Laboratory (TVDL) at the Kennedy Space Center (KSC), Florida, has been using Personal Computer based Data Acquisition and Control Systems (PCDAS) for about nine years. These systems control the generation of toxic vapors of known concentrations under controlled conditions of temperature and humidity. The PCDAS also logs the test conditions and the test article responses in data files for analysis by standard spreadsheets or custom programs. The PCDAS was originally developed to perform standardized qualification and acceptance tests in a search for a commercial off-the-shelf (COTS) toxic vapor detector to replace the hydrazine detectors for the Space Shuttle launch pad. It has since become standard test equipment for the TVDL and is indispensable in producing calibration standards for the new hydrazine monitors at the 10 part per billion (ppb) level. The standard TVDL PCDAS can control two toxic vapor generators (TVG's) with three channels each and two flow/ temperature / humidity (FTH) controllers and it can record data from up to six toxic vapor detectors (TVD's) under test and can deliver flows from 5 to 50 liters per minute (L/m) at temperatures from near zero to 50 degrees Celsius (C) using an environmental chamber to maintain the sample temperature. The concentration range for toxic vapors depends on the permeation source installed in the TVG. The PCDAS can provide closed loop control of temperature and humidity to two sample vessels, typically one for zero gas and one for the standard gas. This is required at very low toxic vapor concentrations to minimize the time required to passivate the sample delivery system. Recently, there have been several requests for information about the PCDAS by other laboratories with similar needs, both on and off KSC. The purpose of this paper is to inform the toxic vapor detection community of the current status and planned upgrades to the automated testing of toxic vapor detectors at the Kennedy Space Center.

Mattson, C. B.↗

Printable Spacecraft: Flexible Electronic Platforms for NASA Missions

Atmospheric confetti. Inchworm crawlers. Blankets of ground penetrating radar. These are some of the unique mission concepts which could be enabled by a printable spacecraft. Printed electronics technology offers enormous potential to transform the way NASA builds spacecraft. A printed spacecraft's low mass, volume and cost offer dramatic potential impacts to many missions. Network missions could increase from a few discrete measurements to tens of thousands of platforms improving areal density and system reliability. Printed platforms could be added to any prime mission as a low-cost, minimum resource secondary payload to augment the science return. For a small fraction of the mass and cost of a traditional lander, a Europa flagship mission might carry experimental printed surface platforms. An Enceladus Explorer could carry feather-light printed platforms to release into volcanic plumes to measure composition and impact energies. The ability to print circuits directly onto a variety of surfaces, opens the possibility of multi-functional structures and membranes such as "smart" solar sails and balloons. The inherent flexibility of a printed platform allows for in-situ re-configurability for aerodynamic control or mobility. Engineering telemetry of wheel/soil interactions are possible with a conformal printed sensor tape fit around a rover wheel. Environmental time history within a sample return canister could be recorded with a printed sensor array that fits flush to the interior of the canister. Phase One of the NIAC task entitled "Printable Spacecraft" investigated the viability of printed electronics technologies for creating multi-functional spacecraft platforms. Mission concepts and architectures that could be enhanced or enabled with this technology were explored. This final report captures the results and conclusions of the Phase One study. First, the report presents the approach taken in conducting the study and a mapping of results against the proposed Phase One objectives. Then an overview of the general field of printed electronics is provided, including manufacturing approaches, commercial drivers, and the current state of integrated systems. The bulk of the report contains the results and findings of Phase One organized into four sections: a survey of components required for a printable spacecraft, technology roadmaps considerations, science mission and engineering applications, and potential risks and challenges of the technology.

Spacecraft↗

Natural Gas/Oxygen Burner Rig at The NASA Glenn Materials Research Laboratory

This technical memorandum describes the development of a new natural gas/oxygen (NG/O2) fueled burner rig to be used for high-temperature environmental durability studies of advanced materials and components at atmospheric pressure. The burner simulates the high-temperature, high-heat flux, and high-velocity thermal environments encountered in aerospace applications. It will be used to study environmental effects such as water vapor interactions relevant to advanced gas turbine engine materials such as ceramic matrix composites with protective environmental barrier coatings. The highest sample temperature achieved to date in a study of the oxidation and recession of monolithic silicon carbide is 3000 °F.

Burner Rig↗

Stop Codon Reassignment in the Wild

Since the discovery of the genetic code and protein translation mechanisms (1), a limited number of variations of the standard assignment between unique base triplets (codons) and their encoded amino acids and translational stop signals have been found in bacteria and phages (2-3). Given the apparent ubiquity of the canonical genetic code, the design of genomically recoded organisms with non-canonical codes has been suggested as a means to prevent horizontal gene transfer between laboratory and environmental organisms (4). It is also predicted that genomically recoded organisms are immune to infection by viruses, under the assumption that phages and their hosts must share a common genetic code (5). This paradigm is supported by the observation of increased resistance of genomically recoded bacteria to phages with a canonical code (4). Despite these assumptions and accompanying lines of evidence, it remains unclear whether differential and non-canonical codon usage represents an absolute barrier to phage infection and genetic exchange between organisms. Our knowledge of the diversity of genetic codes and their use by viruses and their hosts is primarily derived from the analysis of cultivated organisms. Advances in single-cell sequencing and metagenome assembly technologies have enabled the reconstruction of genomes of uncultivated bacterial and archaeal lineages (6). These initial findings suggest that large scale systematic studies of uncultivated microorganisms and viruses may reveal the extent and modes of divergence from the canonical genetic code operating in nature. To explore alternative genetic codes, we carried out a systematic analysis of stop codon reassignments from the canonical TAG amber, TGA opal, and TAA ochre codons in assembled metagenomes from environmental and host-associated samples, single-cell genomes of uncultivated bacteria and archaea, and a collection of phage sequences

09 BIOMASS FUELS↗

Interactive automated Bragg peak identification with 3D neutron scattering data

Neutron scattering experiments have undergone significant technological development through large area detectors with concurrent enhancements in neutron transport and electronic functionality. Data collected for neutron events include detector pixel location in 3D, time and associated metadata, such as, sample orientation, neutron wavelength, and environmental conditions. RadiaSoft and Oak Ridge National Laboratory personnel are considering single-crystal diffraction data from the TOPAZ instrument. We are leveraging a new method for rapid, interactive analysis of neutron data using NVIDIA’s IndeX 3D volumetric visualization framework. We have implemented machine learning techniques to automatically identify Bragg peaks and separate them from diffuse backgrounds and analyze the crystalline lattice parameters for further analysis. The implementation of automatic peak identification into IndeX allows scientists to visualize and analyze data in real-time. Our methods include a robust comparison with current analysis techniques which show improvement in a variety of aspects. These improvements will be incorporated into IndeX for visualization to allow scientists an interactive tool for crystal analysis.

Kilpatrick, Matthew↗

Mercury Speciation via Direct Mercury Analyzer

Mercury has no known biological role, but is present in every living thing and widespread in the environment. As mercury enters an aqueous system, it is subject to methylation or demethylation. Methylmercury selectively partitions into biota and biomagnifies through the food chain. Nearly all methylmercury exposures in the U.S. occur through eating fish and shellfish that contain higher levels of methylmercury. Methyl mercury and other organomercury compounds are more toxic than inorganic mercury. Thus, monitoring and understanding mercury speciation are key to effective environmental management. It is particularly important to be able to separate and measure bioaccumulative-toxic species of mercury such as methyl mercury. We are developing a protocol for utilizing the Direct Mercury Analyzer (DMA-80) for mercury speciation of water samples and to monitor methylmercury (meHg). Objectives: - Advance the understanding of the performance of the direct mercury analysis (DMA) under a range of DOE relevant water chemistry conditions to quantify total mercury: - Demonstrate the applicability of DMA to analysis of typical DOE high level liquid 'tank' waste samples using nonradioactive simulants; Test innovative sorbents to extend the range of the direct mercury analyzer to environmental concentration levels. - Perform scoping tests to demonstrate proof of principle for the chemical reduction amalgamation modular microcolumns for mercury speciation: Examine various microcolumn configurations and document speciation performance for typical DOE high level liquid 'tank' waste samples using nonradioactive simulants; Perform tests to examine extending the speciation paradigm to environmental concentration levels. General Method: all samples analyzed using a direct mercury analyzer (DMA 80) which automates the following steps: 1) pyrolysis to release the mercury, 2) catalysis to convert all mercury to elemental, 3) amalgamation to trap the mercury, 4) desorption to release the mercury as a pulse and 5) spectroscopy to detect the mercury.. Instrument analyzes all mercury species in solids and liquids. The DMA 'eliminates' sample preparation, reduces labor, decreases waste, and results in more practical and cost effective methods. To test the performance of the DMA for DOE relevant conditions, we analyzed samples representative of at high (mg/L) tank waste concentrations in water and in diluted tank waste simulant and analyzed samples representative of environmental (ng/L levels) in water. High concentration samples were analyzed directly in the instrument. Low concentration samples were analyzed by concentrating the mercury onto sorbents such as silica thiol or a mixture of silica thiol and copper. The concentration was performed using microcolumns and placing the columns into the DMA (see below) or by mixing the sorbent into the bulk sample and then filtering ad analyzing the filter in the DMA. Speciation Methods: The speciation tests were based on the selective reduction of inorganic mercury ions - Hg{sup (+} {sup or} {sup 2+)} - to elemental mercury - Hg(0). The elemental mercury is then trapped by amalgamation into the metal. These reactions do not impact methyl mercury allowing for separation. All reactions were performed using powdered elemental copper. To demonstrate proof-of-principle for the selective collection of inorganic mercury, samples were exposed to different amounts of powdered copper (and a control with no copper). This was done using microcolumns and a vacuum box. The columns were placed directly on the DMA for analysis. All materials and conditions were tested using solutions of both inorganic mercury and methyl mercury and all trials were in triplicate. Results and Observations: Validated DMA for high concentration Hg samples such as DOE tank waste: - Liquid inHg - samples were stable on autosampler carousel and results were accurate; - Liquid meHg - samples required a stabilizer. Si-Thiol (0.02 g) in the sample boat generated reliable meHg results. Stabilizer can be added for routine operations. Successful 'proof of principal' in extending DMA range to near environmental levels - using both microcolumns and filtration; - Filtration - Adding Si-Thiol (0.5 g) to sample extracted both inHg and meHg and preserved sample. Handling filters was labor intensive. - Microcolumns - best performance using a combination of copper and Si-Thiol - columns clogged and flowed slowly in some cases; - Practical limit may be in the range of 1 to 5 ng/L due to blanks; - Path Forward - Test additional packing materials and methods to improve flow and consistency, and approaches to minimize blanks. Successful 'proof of principal' for Hg speciation using chemical reduction and amalgamation; - Copper microcolumns (0.5 g Cu) selectively trapped inHg for high concentration mercury samples; - Copper microcolumns (0.5 g Cu selectively trapped inHg for large volume samples at environmental concentrations; - Some sorption of me Hg so that separations not quantitative; - Path Forward - test additional packing materials and alternate eluents to better trap inHg and minimize meHg retention in column.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A portable molecular-sieve-based CO{sub 2} sampling system for radiocarbon measurements

We have developed a field-capable sampling system for the collection of CO{sub 2} samples for radiocarbon-concentration measurements. Most target systems in environmental research are limited in volume and CO{sub 2} concentration, making conventional flask sampling hard or impossible for radiocarbon studies. The present system captures the CO{sub 2} selectively to cartridges containing 13X molecular sieve material. The sampling does not introduce significant under-pressures or significant losses of moisture to the target system, making it suitable for most environmental targets. The system also incorporates a significantly larger sieve container for the removal of CO{sub 2} from chambers prior to the CO{sub 2} build-up phase and sampling. In addition, both the CO{sub 2} and H{sub 2}O content of the sample gas are measured continuously. This enables in situ estimation of the amount of collected CO{sub 2} and the determination of CO{sub 2} flux to a chamber. The portable sampling system is described in detail and tests for the reliability of the method are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of odour on multisensory environmental evaluations of road traffic

This study investigated the effect of odour on multisensory environmental evaluations of road traffic. The study aimed to answer: (1) Does odour have any effect on evaluations on noise, landscape and the overall environment? (2) How different are participants' responses to odour stimuli and are these differences influential on the evaluations? Experimental scenarios varied in three Traffic levels, three Tree screening conditions and two Odour presence conditions were designed, and presented to participants in virtual reality. Perceived Loudness, Noise Annoyance, Landscape Quality and Overall Pleasantness of each scenario were evaluated and the results were analysed. It shows that Odour presence did not have significant main effect on any of the evaluations, but has significant interactions with Traffic level on Noise Annoyance and with Tree screening on Landscape Quality, indicating the potential of odour to modulate noise and visual landscape perceptions in specific environmental content. Concerning participants' responses to odour stimuli, large differences were found in this study. However, the differences did not seem to be influential on environmental evaluations in this study. Larger samples of participants may benefit this study for more significant results of odour effect.

54 ENVIRONMENTAL SCIENCES↗

Implicit sampling combined with reduced order modeling for the inversion of vadose zone hydrological data

Bayesian inverse modeling techniques are computationally expensive because many forward simulations are needed when sampling the posterior distribution of the parameters. Here, in this paper, we combine the implicit sampling method and generalized polynomial chaos expansion (gPCE) to significantly reduce the computational cost of performing Bayesian inverse modeling. There are three steps in this approach: (1) find the maximizer of the likelihood function using deterministic approaches; (2) construct a gPCE-based surrogate model using the results from a limited number of forward simulations; and (3) efficiently sample the posterior distribution of the parameters using implicit sampling method. The cost of constructing the gPCE-based surrogate model is further decreased by using sparse Bayesian learning to reduce the number of gPCE coefficients that have to be determined. We demonstrate the approach for a synthetic ponded infiltration experiment simulated with TOUGH2. The surrogate model is highly accurate with mean relative error that is < 0.035% in predicting saturation and < 0.25% in predicting the likelihood function. The posterior distribution of the parameters obtained using our proposed technique is nearly indistinguishable from the results obtained from either an implicit sampling method or a Markov chain Monte Carlo method utilizing the full mode.

54 ENVIRONMENTAL SCIENCES↗

RAPID SEPARATION METHOD FOR 237NP AND PU ISOTOPES IN LARGE SOIL SAMPLES

A new rapid method for the determination of {sup 237}Np and Pu isotopes in soil and sediment samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used for large soil samples. The new soil method utilizes an acid leaching method, iron/titanium hydroxide precipitation, a lanthanum fluoride soil matrix removal step, and a rapid column separation process with TEVA Resin. The large soil matrix is removed easily and rapidly using this two simple precipitations with high chemical recoveries and effective removal of interferences. Vacuum box technology and rapid flow rates are used to reduce analytical time.

54 ENVIRONMENTAL SCIENCES↗

EMP Attachment 1: DOE-SC PNNL Site Sampling and Analysis Plan

This Sampling and Analysis Plan (SAP) is written for the radiological environmental air surveillance program for the DOE-SC PNNL Site, Richland Washington. It provides the requirements for planning sampling events, and the requirements imposed on the analytical laboratory analyzing the air samples. The actual air sampling process is in procedure EPRP-AIR-029. The rationale for analyte selection, media, and sampling site location has been vetted through the data quality objectives (DQO) process (Barnett et al. 2010). The results from the DQO process have been reviewed and approved by the Washington State Department of Health. The DQO process (Barnett et al. 2010) identified seven specific radionuclides for analysis along with the need for gross alpha and gross beta radiological analyses. The analytes are 241<\sup>Am, 243<\sup>Am, 244<\sup>Cm, 60<\sup>Co, 238<\sup>Pu, 239<\sup>Pu, and 233<\sup>U. The report also determined that air samples for particulates are the only sample matrix required for the monitoring program. These samples are collected on 47-mm glass-fiber filters.

54 ENVIRONMENTAL SCIENCES↗

Prediction of health levels by remote sensing

Measures of the environment derived from remote sensing were compared to census population/housing measures in their ability to discriminate among health status areas in two urban communities. Three hypotheses were developed to explore the relationships between environmental and health data. Univariate and multiple step-wise linear regression analyses were performed on data from two sample areas in Houston and Galveston, Texas. Environmental data gathered by remote sensing were found to equal or surpass census data in predicting rates of health outcomes. Remote sensing offers the advantages of data collection for any chosen area or time interval, flexibilities not allowed by the decennial census.

Rush, M.↗

Long-Term Hydrologic Monitoring Program Sampling and Analysis Results for 2011

The U.S. Department of Energy (DOE) Office of Legacy Management conducted annual sampling at the Rio Blanco site for the LTHMP on May 16 and 17, 2011. The samples were shipped to the U.S. Environmental Protection Agency (EPA) Radiation&Indoor Environments National Laboratory in Las Vegas, Nevada, for analysis. All requested analyses were successfully completed, with the exception of the determination of tritium concentration by the enrichment method, because the laboratory no longer provides that service. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry and tritium using the conventional method. Starting in 2012, DOE will retain a different laboratory that provides the enriched tritium analysis service.

54 ENVIRONMENTAL SCIENCES↗

Long-Term Hydrologic Monitoring Program Sampling and Analysis Results for 2011 at Rulison, Colorado

The U.S. Department of Energy (DOE) Office of Legacy Management conducted annual sampling at the Rulison, Colorado, Site for the Long-Term Hydrologic Monitoring Program (LTHMP) on May 18, 2011. The samples were shipped to the U.S. Environmental Protection Agency (EPA) Radiation and Indoor Environments National Laboratory in Las Vegas, Nevada, for analysis. All requested analyses were successfully completed, with the exception of the determination of tritium concentration by the enrichment method. The laboratory no longer provides that service. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry and for tritium using the conventional method. Starting in 2012, DOE will retain a different laboratory that provides the enriched tritium analysis service.

54 ENVIRONMENTAL SCIENCES↗