Search NASA⌕ Search

SEARCH · Search NASA

Results for “error reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Homogenizing Advanced Alloys: Thermodynamic and Kinetic Simulations Followed by Experimental Results

Segregation of solute elements occurs in nearly all metal alloys during solidification. The resultant elemental partitioning can severely degrade as-cast material properties and lead to difficulties during post-processing (e.g., hot shorts and incipient melting). Many cast articles are subjected to a homogenization heat treatment in order to minimize segregation and improve their performance. Traditionally, homogenization heat treatments are based upon past practice or time-consuming trial and error experiments. Through the use of thermodynamic and kinetic modeling software, NETL has designed a systematic method to optimize homogenization heat treatments. Use of the method allows engineers and researchers to homogenize casting chemistries to levels appropriate for a given application. The method also allows for the adjustment of heat treatment schedules to fit limitations on in-house equipment (capability, reliability, etc.) while maintaining clear numeric targets for segregation reduction. In this approach, the Scheil module within Thermo-Calc is used to predict the as-cast segregation present within an alloy, and then diffusion controlled transformations is used to model homogenization kinetics as a function of time and temperature. Examples of computationally designed heat treatments and verification of their effects on segregation and properties of real castings are presented.

36 MATERIALS SCIENCE↗

Dosimetric comparison between model 9011 and 6711 sources in prostate implants

The purpose of this work is to evaluate the model 9011 iodine-125 ({sup 125}I) in prostate implants by comparing dosimetric coverage provided by the 6711 vs 9011 source implants. Postimplant dosimetry was performed in 18 consecutively implanted patients with prostate cancer. Two were implanted with the 9011 source and 16 with the 6711 source. For purposes of comparison, each implant was then recalculated assuming use of the other source. The same commercially available planning system was used and the specific source data for both 6711 and 9011 products were entered. The results of these calculations are compared side by side in the terms of the isodose values covering 100% (D100) and 90% (D90) of prostate volume, and the percentages of volumes of prostate, bladder, rectum, and urethra covered by 200% (V200), 150% (V150), 100% (V100), 50% (V50), and 20% (V20) of the prescribed dose as well. The 6711 source data overestimate coverage by 6.4% (ranging from 4.9% to 6.9%; median 6.6%) at D100 and by 6.6% (ranging from 6.2% to 6.8%; median 6.6%) at D90 compared with actual 9011 data. Greater discrepancies of up to 67% are seen at higher dose levels: average reduction for V100 is 2.7% (ranging from 0.6% to 7.7%; median 2.3%), for V150 is 14.6% (ranging from 6.1% to 20.5%; median 15.3%), for V200 is 14.9% (ranging from 4.8% to 19.1%; median 16%); similarly seen in bladder, rectal, and urethral coverage. This work demonstrates a clear difference in dosimetric behavior between the 9011 and 6711 sources. Using the 6711 source data for 9011 source implants would create a pronounced error in dose calculation. This study provides evidence that the 9011 source can provide the same dosimetric quality as the 6711 source, if properly used; however, the 6711 source data should not be considered as a surrogate for the 9011 source implants.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cancer-Associated IDH1 Mutations Produce 2-hydroxyglutarate

Mutations in the enzyme cytosolic isocitrate dehydrogenase 1 (IDH1) are a common feature of a major subset of primary human brain cancers. These mutations occur at a single amino acid residue of the IDH1 active site, resulting in loss of the enzyme's ability to catalyse conversion of isocitrate to {alpha}-ketoglutarate. However, only a single copy of the gene is mutated in tumours, raising the possibility that the mutations do not result in a simple loss of function. Here we show that cancer-associated IDH1 mutations result in a new ability of the enzyme to catalyse the NADPH-dependent reduction of {alpha}-ketoglutarate to R(-)-2-hydroxyglutarate (2HG). Structural studies demonstrate that when arginine 132 is mutated to histidine, residues in the active site are shifted to produce structural changes consistent with reduced oxidative decarboxylation of isocitrate and acquisition of the ability to convert {alpha}-ketoglutarate to 2HG. Excess accumulation of 2HG has been shown to lead to an elevated risk of malignant brain tumours in patients with inborn errors of 2HG metabolism. Similarly, in human malignant gliomas harbouring IDH1 mutations, we find markedly elevated levels of 2HG. These data demonstrate that the IDH1 mutations result in production of the onco-metabolite 2HG, and indicate that the excess 2HG which accumulates in vivo contributes to the formation and malignant progression of gliomas.

59 BASIC BIOLOGICAL SCIENCES↗

AI/ML-Enhanced Wind Forecasts for Reducing Uncertainty in Prescribed Fire Planning

Prescribed fire is a vital tool for ecosystem management and wildfire risk reduction but its escalation is constrained by overly conservative burn windows because of uncertainties, for instance, in wind forecasts. This review describes the state of the art in weather product use by fire/smoke models and identifies three priority research gaps that artificial intelligence/machine learning (AI/ML) is well positioned to address: (1) spatial and temporal downscaling to meter-scale, sub-hourly wind fields; (2) bias correction for systematic model errors in complex terrain; and (3) robust uncertainty quantification to inform ensemble-based simulations. Emerging AI/ML techniques offer promising frameworks to address all three challenges. By providing high-resolution, bias-corrected, and probabilistic wind fields, AI/ML-enhanced forecasts will allow for expanded burn windows, improved ignition strategy design and a reduced reliance on expert intuition, especially when a prescribed fire is introduced into new areas.

54 ENVIRONMENTAL SCIENCES↗

AGC-2 Specimen Position Adjustment

This engineering calculations and analysis report (ECAR) calculates the Advanced Graphite Creep (AGC)-2 specimen position adjustments that result from (1) as-built dimension corrections of the Advanced Test Reactor (ATR) reactor, experiment, and specimens, (2) thermal growth of the capsule wall and graphite components, and (3) variable specimen elevations as the specimen stacks shrink due to radiation -induced shrinkage and axial load- induced creep. The specimen elevations listed in the experiment assembly documents do not accurately represent the actual specimen positions in relation to the reactor core mid-plane. Prior experiment insertion difficulties have shown that the distance from the reactor top head closure plate to the core is greater than the nominal elevations shown on the ATR facility drawings. Drawing 600001 lists the measured difference between the closure plate and the gearbox support beam as 0.313 in.ches greater than the facility drawings. Thus, the height of the specimens in relation to the core mid-plane is 0.313 in.ches higher than the nominal dimensions. AlsoIn addition, the overall dimension of the experiment is 0.084 in. shorter than the nominal drawing dimension on Drawing 601266 [1]. As a further adjustment, the average weld shrinkage of the three capsule welds is 0.035 each, which affects the as-built position of the lower isolation weld plate (i.e., Part #601266-9) onto which all graphite components are stacked. In addition to the as-built adjustments mentioned above, the specimens also are subject to a stack up error, which is due to their the thickness difference from nominal. This effect is most apparent in the center S-7 stack which that has a large number of specimens (i.e., 170 specimens). Per post-irradiation examination (PIE) measurements, the average S-7 specimen is about 0.0008 in. smaller than nominal. Even though this difference is small, when multiplied by the number specimens, the top specimen experiences an elevation reduction of 0.14 inches. Although dimensional changes were less pronounced in S-1 through S-6, specimen elevations were adjusted based on pre-irradiation length measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Machine Learning Techniques for Data Reduction of Climate Applications

Scientists conduct large-scale simulations to compute derived quantities-of-interest (QoI) from primary data. Often, QoI are linked to specific features, regions, or time intervals, such that data can be adaptively reduced without compromising the integrity of QoI. For many spatiotemporal applications, these QoI are binary in nature and represent presence or absence of a physical phenomenon. We present a pipelined compression approach that first uses neural-network-based techniques to derive regions where QoI are highly likely to be present. Then, we employ a Guaranteed Autoencoder (GAE) to compress data with differential error bounds. GAE uses QoI information to apply low-error compression to only these regions. This results in overall high compression ratios while still achieving downstream goals of simulation or data collections. Experimental results are presented for climate data generated from the E3SM Simulation model for downstream quantities such as tropical cyclone and atmospheric river detection and tracking. These results show that our approach is superior to comparable methods in the literature.

Li, Xiao [University of Florida]↗

The Use of the Active Breathing Coordinator Throughout Radical Non-Small-Cell Lung Cancer (NSCLC) Radiotherapy

Purpose: To assess feasibility and reproducibility of an Active Breathing Coordinator (ABC) used throughout radical radiotherapy for non-small-cell lung cancer, and compare lung dosimetric parameters between free-breathing and ABC plans. Methods and Materials: A total of 18 patients, recruited into an approved study, had free-breathing and ABC breath-hold treatment plans generated. Lung volume, the percentage volume of lung treated to a dose of {>=}20 Gy (V{sub 20}), and mean lung dose (MLD) were compared. Treatment (64 Gy in 32 fractions, 5 days/week) was delivered in breath-hold. Repeat breath-hold computed tomography scans were used to assess change in gross tumor volume (GTV) size and position. Setup error was also measured and potential GTV-planning target volume (PTV) margins calculated. Results: Seventeen of 18 patients completed radiotherapy using ABC daily. Intrafraction tumor position was consistent, but interfraction variation had mean (range) values of 5.1 (0-25), 3.6 (0-9.7), and 3.5 (0-16.6) mm in the superoinferior (SI), right-left (RL), and anteroposterior (AP) directions, respectively. Tumor moved partially outside the PTV in 5 patients. Mean reduction in GTV from planning to end of treatment was 25% (p = 0.003). Potentially required PTV margins were 18.1, 11.9, and 11.9 mm in SI, RL, and AP directions. ABC reduced V{sub 20} by 13% (p = 0.0001), V{sub 13} by 12% (p = 0.001), and MLD by 13% (p < 0.001) compared with free-breathing; lung volume increased by 41% (p < 0.001). Conclusions: Clinically significant movements of GTV were seen during radiotherapy for non-small-cell lung cancer using ABC. Image guidance is recommended with ABC. The use of ABC can reduce dose volume parameters determining lung toxicity, and might allow for equitoxic radiotherapy dose escalation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trajectory sampling and finite-size effects in first-principles stopping power calculations

Abstract Real-time time-dependent density functional theory (TDDFT) is presently the most accurate available method for computing electronic stopping powers from first principles. However, obtaining application-relevant results often involves either costly averages over multiple calculations or ad hoc selection of a representative ion trajectory. We consider a broadly applicable, quantitative metric for evaluating and optimizing trajectories in this context. This methodology enables rigorous analysis of the failure modes of various common trajectory choices in crystalline materials. Although randomly selecting trajectories is common practice in stopping power calculations in solids, we show that nearly 30% of random trajectories in an FCC aluminum crystal will not representatively sample the material over the time and length scales feasibly simulated with TDDFT, and unrepresentative choices incur errors of up to 60%. We also show that finite-size effects depend on ion trajectory via “ouroboros” effects beyond the prevailing plasmon-based interpretation, and we propose a cost-reducing scheme to obtain converged results even when expensive core-electron contributions preclude large supercells. This work helps to mitigate poorly controlled approximations in first-principles stopping power calculations, allowing 1–2 order of magnitude cost reductions for obtaining representatively averaged and converged results.

36 MATERIALS SCIENCE↗

Global Sensitivity Analysis of Bulk Properties of an Atomic Nucleus

We perform a global sensitivity analysis of the binding energy and the charge radius of the nucleus 16 O to identify the most influential low-energy constants in the next-to-next-to-leading order chiral Hamiltonian with two- and three-nucleon forces. For this purpose, we develop a subspace-projected coupled-cluster method using eigenvector continuation [Frame D. et al., Phys. Rev. Lett. 121, 032501 (2018)]. With this method, we compute the binding energy and charge radius of 16 O at more than 106 different values of the 16 low-energy constants in one hour on a standard laptop computer. For relatively small subspace projections, the root-mean-square error is about 1% compared to full-space coupled-cluster results. We find that 58(1)% of the variance in energy can be apportioned to a single contact term in the 3 S 1 wave, whereas the radius depends sensitively on several low-energy constants and their higher-order correlations. The results identify the most important parameters for describing nuclear saturation and help prioritize efforts for uncertainty reduction of theoretical predictions. The achieved acceleration opens up an array of computational statistics analyses of the underlying description of the strong nuclear interaction in nuclei across the Segrè chart.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Large-Scale Uncertainty and Error Analysis for Time-dependent Fluid/Structure Interactions in Wind Turbine Applications

The following is the final report covering the entire period of this aforementioned grant, June 1, 2011 - May 31, 2013 for the portion of the effort corresponding to Stanford University (SU). SU has partnered with Sandia National Laboratories (PI: Mike S. Eldred) and Purdue University (PI: Dongbin Xiu) to complete this research project and this final report includes those contributions made by the members of the team at Stanford. Dr. Eldred is continuing his contributions to this project under a no-cost extension and his contributions to the overall effort will be detailed at a later time (once his effort has concluded) on a separate project submitted by Sandia National Laboratories. At Stanford, the team is made up of Profs. Alonso, Iaccarino, and Duraisamy, post-doctoral researcher Vinod Lakshminarayan, and graduate student Santiago Padron. At Sandia National Laboratories, the team includes Michael Eldred, Matt Barone, John Jakeman, and Stefan Domino, and at Purdue University, we have Prof. Dongbin Xiu as our main collaborator. The overall objective of this project was to develop a novel, comprehensive methodology for uncertainty quantification by combining stochastic expansions (nonintrusive polynomial chaos and stochastic collocation), the adjoint approach, and fusion with experimental data to account for aleatory and epistemic uncertainties from random variable, random field, and model form sources. The expected outcomes of this activity were detailed in the proposal and are repeated here to set the stage for the results that we have generated during the time period of execution of this project: 1. The rigorous determination of an error budget comprising numerical errors in physical space and statistical errors in stochastic space and its use for optimal allocation of resources; 2. A considerable increase in efficiency when performing uncertainty quantification with a large number of uncertain variables in complex non-linear multi-physics problems; 3. A solution to the long-time integration problem of spectral chaos approaches; 4. A rigorous methodology to account for aleatory and epistemic uncertainties, to emphasize the most important variables via dimension reduction and dimension-adaptive refinement, and to support fusion with experimental data using Bayesian inference; 5. The application of novel methodologies to time-dependent reliability studies in wind turbine applications including a number of efforts relating to the uncertainty quantification in vertical-axis wind turbine applications. In this report, we summarize all accomplishments in the project (during the time period specified) focusing on advances in UQ algorithms and deployment efforts to the wind turbine application area. Detailed publications in each of these areas have also been completed and are available from the respective conference proceedings and journals as detailed in a later section.

97 MATHEMATICS AND COMPUTING↗

Progressive construction of a parametric reduced‐order model for PDE‐constrained optimization

Summary An adaptive approach to using reduced‐order models (ROMs) as surrogates in partial differential equations (PDE)‐constrained optimization is introduced that breaks the traditional offline‐online framework of model order reduction. A sequence of optimization problems constrained by a given ROM is defined with the goal of converging to the solution of a given PDE‐constrained optimization problem. For each reduced optimization problem, the constraining ROM is trained from sampling the high‐dimensional model (HDM) at the solution of some of the previous problems in the sequence. The reduced optimization problems are equipped with a nonlinear trust‐region based on a residual error indicator to keep the optimization trajectory in a region of the parameter space where the ROM is accurate. A technique for incorporating sensitivities into a reduced‐order basis is also presented, along with a methodology for computing sensitivities of the ROM that minimizes the distance to the corresponding HDM sensitivity, in a suitable norm. The proposed reduced optimization framework is applied to subsonic aerodynamic shape optimization and shown to reduce the number of queries to the HDM by a factor of 4‐5, compared with the optimization problem solved using only the HDM, with errors in the optimal solution far less than 0.1%. Copyright © 2014 John Wiley & Sons, Ltd.

Zahr, Matthew J.↗

Reduced Order Model of Transactive Bidding Loads

Transactive energy (TE) has been identified to provide better grid efficiency and reliability by market-based transactive exchanges between energy producers and energy consumers. Simulations of TE systems are crucial to evaluate the benefits and impacts of different transactive mechanisms. However, such simulations can be time consuming due to the information exchange between various participants and complex co-simulation environments. In this paper, we develop a reduced order model to speed up the simulation of transactive systems in TE simulation platform (TESP) while achieving very low error between the reduced order and full model results. Specifically, the developed reduced order model consists of an aggregate responsive load agent which utilizes two Recurrent Neural Networks (RNNs) with Long Short-Term Memory units (LSTMs) to enable transactive elements to collectively participate in the TE system. The proposed aggregate responsive load (ARL) agent is able to produce similar transactive behaviors to the full simulation model while achieving significant simulation time reduction. Finally, we also show that the developed model enables generalization of simulation results across different dates and across different number of loads included in the simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The extraction of true profiles for TPS commissioning and its impact on IMRT patient-specific QA

The aim of this work is to investigate the clinical impact of detector size effect on patient specific intensity-modulated radiation therapy (IMRT) quality assurance (QA). Two photon beam models, BM6 and BM4, were commissioned using photon beam profiles measured with a 6 mm diameter and a 4 mm diameter ion chambers, respectively. A method was developed to extract the ''true'' cross beam profiles, free of volume averaging effect, using analytic fitting/deconvolution. The method was validated using beam profiles measured with a small (0.8 mm) diode detector for small ({<=}10x10 cm{sup 2}) field sizes. These profiles were used to commission a third beam model (BM08). Planar dose distributions for eight IMRT plans (total of 53 fields) were calculated using the three beam models and measured with a two-dimensional detector array. Analysis using percent dose difference and distance-to-agreement criteria between the calculation and measurement was done to benchmark the performance of each beam model. The average passing rates between calculation and measurement were 93.8%, 98.9%, and 99.4% for BM6, BM4, and BM08, respectively, when 3%/3 mm criteria were used. A gradual increase in passing rates was noticed with the decrease in the size of the detector used to collect commissioning data. When 2%/2 mm criteria were used, the average passing rates increased significantly from 81.6% (BM6) to 92.6% (BM4) and 96.8% (BM08). These results quantify the enhancement of IMRT dose calculation accuracy with the reduction in detector size used for photon beam profiles measurement. Our study indicates that volume averaging effect can significantly affect the results of IMRT patient specific QA. By removing the detector size effect in beam commissioning, excellent passing rates can be achieved with more stringent criteria such as 2%/2 mm. The use of more stringent criteria for IMRT patient specific QA would likely result in higher chances of detecting any dosimetric errors arising from the treatment planning or delivery system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Red-QAOA: Efficient Variational Optimization through Circuit Reduction

The Quantum Approximate Optimization Algorithm (QAOA) provides a quantum solution for combinatorial optimization problems. However, the optimal parameter searching process of QAOA is greatly affected by noise, leading to non-optimal solutions. This paper introduces a novel approach to optimize QAOA by exploiting the energy landscape concentration of similar instances via graph reduction, thus addressing the effect of noise. We formalize the notion of similar instances in QAOA and develop a Simulated Annealing-based graph reduction algorithm, called Red-QAOA, to identify the most similar subgraph for efficient parameter optimization. Red-QAOA outperforms state-of-the-art Graph Neural Network (GNN) based graph pooling techniques in performance and demonstrates effectiveness on a diverse set of real-world optimization problems encompassing 3200 graphs. Red-QAOA reduced the node counts and edge counts by 28% and 37%, respectively, while maintaining a low mean square error of 2%. These enable the identification of an optimal parameter set that is closer to the ideal true optimal solution in the presence of noise. By substantially streamlining the search for QAOA parameters, our approach sets the stage for the practical application of quantum algorithms in solving complex optimization problems.

Wang, Meng↗

A general framework and review of scatter correction methods in x-ray cone-beam computerized tomography. Part 1: Scatter compensation approaches

Since scattered radiation in cone-beam volume CT implies severe degradation of CT images by quantification errors, artifacts, and noise increase, scatter suppression is one of the main issues related to image quality in CBCT imaging. The aim of this review is to structurize the variety of scatter suppression methods, to analyze the common structure, and to develop a general framework for scatter correction procedures. In general, scatter suppression combines hardware techniques of scatter rejection and software methods of scatter correction. The authors emphasize that scatter correction procedures consist of the main components scatter estimation (by measurement or mathematical modeling) and scatter compensation (deterministic or statistical methods). The framework comprises most scatter correction approaches and its validity also goes beyond transmission CT. Before the advent of cone-beam CT, a lot of papers on scatter correction approaches in x-ray radiography, mammography, emission tomography, and in Megavolt CT had been published. The opportunity to avail from research in those other fields of medical imaging has not yet been sufficiently exploited. Therefore additional references are included when ever it seems pertinent. Scatter estimation and scatter compensation are typically intertwined in iterative procedures. It makes sense to recognize iterative approaches in the light of the concept of self-consistency. The importance of incorporating scatter compensation approaches into a statistical framework for noise minimization has to be underscored. Signal and noise propagation analysis is presented. A main result is the preservation of differential-signal-to-noise-ratio (dSNR) in CT projection data by ideal scatter correction. The objective of scatter compensation methods is the restoration of quantitative accuracy and a balance between low-contrast restoration and noise reduction. In a synopsis section, the different deterministic and statistical methods are discussed with respect to their properties and applications. The current paper is focused on scatter compensation algorithms. The multitude of scatter estimation models will be dealt with in a separate paper.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Open-Shell Tensor Hypercontraction

The extension of least-squares tensor hypercontracted second- and third-order Møller–Plesset perturbation theory (LS-THC-MP2 and LS-THC-MP3) to open-shell systems is an important development due to the scaling reduction afforded by THC and the ubiquity of molecular ions, radicals, and other open-shell reactive species. The complexity of wavefunction-based quantum-chemical methods such as Møller–Plesset and coupled cluster theory is reflected in the steep scaling of the computational costs with the molecular size. The least-squares tensor hypercontraction (LS-THC) method is an efficient, single-step factorization for the two-electron integral tensor but can also be used to factorize the double excitation amplitudes, leading to significant scaling reduction. Herein we extend this promising method to open-shell variants of LS-THC-MP2 and -MP3 by using diagrammatic techniques and explicit spin summation. The accuracy of the resulting methods for open-shell species is benchmarked on standard test systems such as regular alkanes as well as realistic systems involving bond breaking, radical stabilization, and other effects. We find that open-shell LS-THC-MPn methods exhibit errors highly comparable to those produced by closed-shell LS-THC-MPn and are highly insensitive to particular chemical interactions, geometries, or even moderate spin contamination.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A path to stable low-torque plasma operation in ITER with test blanket modules

New experiments in the low-torque ITER Q = 10 scenario on DIII-D demonstrate that n = 1 magnetic fields from a single row of ex-vessel control coils enable operation at ITER performance metrics in the presence of applied non-axisymmetric magnetic fields from a test blanket module (TBM) mock-up coil. With n = 1 compensation, operation below the ITER-equivalent injected torque is successful at three times the ITER equivalent toroidal magnetic field ripple for a pair of TBMs in one equatorial port, whereas the uncompensated TBM field leads to rotation collapse, loss of H-mode and plasma current disruption. In companion experiments at high plasma beta, where the n = 1 plasma response is enhanced, uncorrected TBM fields degrade energy confinement and the plasma angular momentum while increasing fast ion losses; however, disruptions are not routinely encountered owing to increased levels of injected neutral beam torque. In this regime, n = 1 field compensation leads to recovery of a dominant fraction of the TBM-induced plasma pressure and rotation degradation, and an 80% reduction in the heat load to the first wall. These results show that the n = 1 plasma response plays a dominant role in determining plasma stability, and that n = 1 field compensation alone not only recovers most of the impact on plasma performance of the TBM, but also protects the first wall from potentially damaging heat flux. Despite these benefits, plasma rotation braking from the TBM fields cannot be fully recovered using standard error field control. Lastly, given the uncertainty in extrapolation of these results to the ITER configuration, it is prudent to design the TBMs with as low a ferromagnetic mass as possible without jeopardizing the TBM mission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic Undervolting to Improve Energy Efficiency on Multicore X86 CPUs

Chip manufacturers introduce redundancy at various levels of CPU design to guarantee correct operation, even for worst-case combinations of non-idealities in process variation and system operating conditions. This redundancy is implemented partly in the form of voltage margins. However, for a wide range of real-world execution scenarios these margins are excessive and merely translate to increased power consumption, hindering the effort towards higher-energy efficiency in both HPC and general purpose computing. Our study on the x86-64 Haswell and Skylake multicore microarchitectures reveals-wide voltage margins, which vary across different microarchitectures, different chip parts of the same microarchitecture, and across different workloads. We find that it is necessary to quantify-voltage margins using multi-threaded and multi-instance workloads, as characterization with single-threaded and single-instance workloads that do not stress the CPU to its full capacity typically identifies overly optimistic margins that lead to errors when applied in realistic program execution scenarios. In addition, we introduce, deploy and evaluate a run-time governor that dynamically reduces the supply voltage of modern multicore x86-64 CPUs. Our governor employs a model that takes as input a set of performance metrics which are directly measurable via performance monitoring counters and have high predictive value for the minimum tolerable supply voltage (V min ), to predict and apply the appropriate reduction for the workload at hand. Compared with the conventional DVFS governor, our approach in this study achieves up to 42 percent energy savings for the Skylake family and 34 percent for the Haswell family for complex, real-world applications.

97 MATHEMATICS AND COMPUTING↗