Search NASA⌕ Search

SEARCH · Search NASA

Results for “field protocols”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Effect of intermittent standing and walking on physiological changes induced by head-down bed rest

Continuous exposure to gravity may not be necessary to prevent compromised physiological function resulting from exposure to microgravity. However, minimum gravity (G) exposure requirements, effectiveness of passive Gz versus activity in a G field, and optimal G stimulus amplitude, duration, and frequency are unknown. To partially address these questions, a 4-day, 6 degree head-down bed rest (HDBR) study (one ambulatory control day, 4 full HDBR days, one recovery day) was conducted. Nine males, 30-50 yr, were subjected to four different +1 Gz (head-foot) exposure protocols (periodic standing or controlled walking for 2 or 4 h/day in 15 min doses), plus a continuous HDBR (0 Gz) control. Standing 4 h completely prevented and standing 2 h partially prevented post-HDBR orthostatic intolerance. Both walking conditions (2 h and 4 h) attenuated the decrease in peak VO2 and prevented the increased urinary Ca2+ excretion associated with HDBR. Both 4 h conditions (standing and walking) attenuated plasma volume loss during HDBR. It was concluded that various physiological systems benefit differentially from passive +1 Gz or activity in +1 Gz and the duration (2 h vs. 4 h) of the stimulus may be an important moderating factor.

Vernikos, J.↗

Constraining Oceanic Sources and Sinks of CO2 by Inverse Modeling: A First Step Toward Assimilation of In Situ and Remote Data

The primary goal of this collaborative project, lead by Nicholas Gruber at UCLA, is to better quantify the air-sea fluxes of pre-industrial and anthropogenic carbon dioxide CO2 for the global ocean with a newly developed inverse method. The method involves using ocean general circulation models (OGCMs) to characterize the subsurface distribution of tracers injected for different regions of the ocean surface. By linearly combining a series of these basis (or Greens) functions, one should be able to recreate any arbitrary ocean tracer field. In our case, we are using the global database of ocean dissolved inorganic carbon (DIC) from the WOCE/JGOFS global CO2 survey from the 1990s. The observed DIC field has been partitioned into pre-industrial and anthropogenic components using the empirical C* technique. We then solve for an optimal combination of the regional basis functions that best match the two sets observations in a least-squares sense with singular value decomposition. This in turn provides solutions for the regional air-sea CO2 fluxes (pre-industrial and anthropogenic) that are independent of more traditional estimates derived from surface water disequilibria in the partial pressure of CO2 and wind speed gas exchange parameterizations. We are apply the method to a suite of nine different OGCMs to test the robustness of the derived surface fluxes fields to differences in ocean circulation. Together with a collegue Keith Lindsay at NCAR, S. Doney's role in this project was to create the appropriate steady-state and temporally evolving basis functions from the NCAR CSM-1 ocean circulation model. Because of a slow start across the project in defining a common set of experimental protocols, we requested and were given a one year, no cost extension. Both the steady-state and temporally evolving basis functions were delivered to the UCLA group for further analysis. Additional information is included in the original extended abstract.

Doney, Scott↗

The evolution of contact prediction: Evidence that contact selection in statistical contact prediction is changing

Over the last few years, the field of protein structure prediction has been transformed by increasingly-accurate contact prediction software. These methods are based on the detection of coevolutionary relationships between residues from multiple sequence alignments. However, despite speculation, there is little evidence of a link between contact prediction and the physico-chemical interactions which drive amino-acid coevolution. Furthermore, existing protocols predict only a fraction of all protein contacts and it is not clear why some contacts are favoured over others. Using a dataset of 863 protein domains, we assessed the physico-chemical interactions of contacts predicted by CCMpred, MetaPSICOV, and DNCON2, as examples of direct coupling analysis, meta-prediction, and deep learning. We considered correctly-predicted contacts and compared their properties against the protein contacts that were not predicted. Predicted contacts tend to form more bonds than non-predicted contacts, which suggests these contacts may be more important than contacts that were not predicted. Comparing the contacts predicted by each method, we found that metaPSICOV and DNCON2 favour accuracy whereas CCMPred detects contacts with more bonds. This suggests that the push for higher accuracy may lead to a loss of physico-chemically important contacts. These results underscore the connection between protein physico-chemistry and the coevolutionary couplings that can be derived from multiple sequence alignments. This relationship is likely to be relevant to protein structure prediction and functional analysis of protein structure and may be key to understanding their utility for different problems in structural biology. We use publicly-available databases. Our code is available for download at http://opig.stats.ox.ac.uk/.

59 BASIC BIOLOGICAL SCIENCES↗

TH-C-BRD-11: Robustness of Pencil Beam Scanning Proton Therapy for Pelvic Cancer Under Anatomical Changes

Purpose: Pencil beam scanning (PBS) proton therapy provides excellent dosimetric benefits in pelvic cancer treatment, yet day-to-day anatomical variations in pelvic region tend to cause range uncertainties. This study evaluates the dosimetric robustness under anatomical changes for three PBS intensity-modulated proton therapy (IMPT), IMPT using worstcase robust optimization (thereafter ‘Robust IMPT’), and single-field uniform dose (SFUD), in cervical cancer treatment. Methods: IMPT, Robust IMPT, and SFUD plans using the same beam directions and the same prescription (Rx) were generated on computed tomography (CT) images acquired on the simulation day. The dose from each plan was then recomputed on CT images acquired in subsequent two to five weeks using the same protocol. The weekly CTs were registered to the planning CT based on bony anatomy. Target coverage was considered adequate on each weekly CT if dose to 99% of the internal target volume (D-ITV99%) reached at least 95% of the Rx dose. Statistical analysis was then performed on the 21 weekly CT images available for the 7 enrolled patients. Results: Statistically, IMPT was unable to maintain target coverage (mean D-ITV99% = 90.5% Rx, p = 0.004), and SFUD was able to maintain target coverage (mean D-ITV99% = 98.0% Rx, p = 0.0064), in the weeks following simulation. Robust IMPT was able to improve the robustness of IMPT significantly (p < 0.0001), though its maintenance of target coverage was not statistically significant by the 95% Rx criteria (mean D-ITV99% = 96.0%, p = 0.1677). Conclusion: During the multi-week treatment course with anatomical variations, SFUD is robust in terms of maintaining target coverage while IMPT is not. The worst-case optimized Robust IMPT, assuming ±3.5% range uncertainties, improves the robustness of IMPT under anatomical changes significantly, even though it was not designed to account for anatomical changes by mechanism.

60 APPLIED LIFE SCIENCES↗

SU-F-J-48: Effect of Scan Length On Magnitude of Imaging Dose in KV CBCT

Purpose: To study effect of scan length on magnitude of imaging dose deposition in Varian kV CBCT for head & neck and pelvis CBCT. Methods: To study effect of scan length we measured imaging dose at depth of 8 cm for head and neck Cone Beam Computed Tomography (CBCT) acquisition ( X ray beam energy is used 100kV and 200 degree of gantry rotation) and at 16 cm depth for pelvis CBCT acquisition ( X ray beam energy used is 125 kV and 360 degree of gantry rotation) in specially designed phantom. We used farmer chamber which was calibrated in kV X ray range for measurements .Dose was measured with default field size, and reducing field size along y direction to 10 cm and 5 cm. Results: As the energy of the beam decreases the scattered radiation increases and this contributes significantly to the dose deposited in the patient. By reducing the scan length to 10 Cm from default 20.6 cm we found a dose reduction of 14% for head and neck CBCT protocol and a reduction of 26% for pelvis CBCT protocol. Similarly for a scan length of 5cm compared to default the dose reduction in head and neck CBCT protocol is 36% while in the pelvis CBCT protocol the dose reduction is 50%. Conclusion: By limiting the scan length we can control the scatter radiation generated and hence the dose to the patient. However the variation in dose reduction for same length used in two protocols is because of the scan geometry. The pelvis CBCT protocol uses a full rotation and head and neck CBCT protocol uses partial rotation.

60 APPLIED LIFE SCIENCES↗

Tests of microstructure reconstruction by forward modeling of high energy X-ray diffraction microscopy data

Verification tests of the forward modeling technique for near-field high energy X-ray diffraction microscopy are conducted using two simulated microstructures containing uniformly distributed orientations. Comparison between the simulated and reconstructed microstructures is examined with consideration to both crystallographic orientation and spatial geometric accuracy. To probe the dependence of results on experimental parameters, simulated data sets use two different detector configurations and different simulated experimental protocols; in each case, the parameters mimic the experimental geometry used at Advanced Photon Source beamline 1-ID. Results indicate that element orientations are distinguishable to less than 0.1{sup o}, while spatial geometric accuracy is limited by the detector resolution.

36 MATERIALS SCIENCE↗

NASA Tech Briefs, December 2012

The topics include: Pattern Generator for Bench Test of Digital Boards; 670-GHz Down- and Up-Converting HEMT-Based Mixers; Lidar Electro-Optic Beam Switch with a Liquid Crystal Variable Retarder; Feedback Augmented Sub-Ranging (FASR) Quantizer; Real-Time Distributed Embedded Oscillator Operating Frequency Monitoring; Software Modules for the Proximity-1 Space Link Interleaved Time Synchronization (PITS) Protocol; Description and User Instructions for the Quaternion to Orbit v3 Software; AdapChem; Mars Relay Lander and Orbiter Overflight Profile Estimation; Extended Testability Analysis Tool; Interactive 3D Mars Visualization; Rapid Diagnostics of Onboard Sequences; MER Telemetry Processor; pyam: Python Implementation of YaM; Process for Patterning Indium for Bump Bonding; Archway for Radiation and Micrometeorite Occurrence Resistance; 4D Light Field Imaging System Using Programmable Aperture; Device and Container for Reheating and Sterilization; Radio Frequency Plasma Discharge Lamps for Use as Stable Calibration Light Sources; Membrane Shell Reflector Segment Antenna; High-Speed Transport of Fluid Drops and Solid Particles via Surface Acoustic Waves; Compact Autonomous Hemispheric Vision System; A Distributive, Non-Destructive, Real-Time Approach to Snowpack Monitoring; Wideband Single-Crystal Transducer for Bone Characterization; Numerical Simulation of Rocket Exhaust Interaction With Lunar Soil; Motion Imagery and Robotics Application (MIRA): Standards-Based Robotics; Particle Filtering for Model-Based Anomaly Detection in Sensor Networks; Ka-band Digitally Beamformed Airborne Radar Using SweepSAR Technique; Composite With In Situ Plenums; Multi-Beam Approach for Accelerating Alignment and Calibration of HyspIRI-Like Imaging Spectrometers; JWST Lifting System; Next-Generation Tumbleweed Rover; Pneumatic System for Concentration of Micrometer-Size Lunar Soil.

Source record↗

Effects of spectral entanglement in polarization-entanglement swapping and type-I fusion gates

We examine how spectral entanglement in polarization-entangled photon states generated from bulk-crystal, spontaneous parametric down-conversion affects the success of entanglement swapping and type-I fusion gates. We quantify the success of the entanglement swapping and fusion gates by calculating the bipartite concurrence and residual tangle, respectively, in terms of the joint spectral probability amplitudes of the initial broad-bandwidth polarization-entangled states. We find that both polarization-entanglement measures depend strongly on the initial spectral entanglement, as well as on the configuration of the independent sources. Specifically, when spectral differences correlate with polarization, the optimal source configuration is different for the two protocols. We conclude that this distinction is founded in how the underlying Bell-state measurement and quantum-erasure techniques respond differently to distinguishing spectral information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Methodology for Extracting High-Molecular-Weight DNA from Field Collections of Macrofungi

Many macrofungi are impractical or impossible to culture. Consequently, DNA for long-read sequencing required for the assembly of high-quality genomes must be isolated from samples taken from the environment. Collection is often in remote locations, limiting the options for stabilising samples to methods that do not require refrigeration. Fungi contain species-specific arrays of metabolites that may complicate purification techniques and call for judgement to be made to apply appropriate modifications to the DNA extraction protocol in specific cases. The protocols and commentary we describe are informed by the preparation of DNA from a range of Australasian ectomycorrhizal and saprotrophic macrofungi. We collect samples into isopropanol at ambient temperature and employ a strategy of chromatin isolation followed by the sequential removal of unwanted molecular components to purify DNA.

Burgoyne, Leigh A↗

UEMtomaton: A Source-Available Platform to Aid in Start-up of Ultrafast Electron Microscopy Labs

The steady rise in the number of ultrafast electron microscopy (UEM) labs, in addition to the opacity and lack of detailed descriptions of current approaches that would enable point-by-point construction, has created an opportunity for sharing common methods and instrumentation for (for example) automating data acquisition to assist in efficient lab start-up and to learn about common and robust protocols. In the spirit of open sharing of methods, we provide here a description of an entry-level method and user interface (UI) for automating UEM experiments, and we provide access to the source code and scripts (source-available) for ease of implementation or as a starting reference point for those entering or seeking to enter the field (https://github.com/CEMSFlannigan/UEMtomaton/releases/tag/v1.0). Core instrumentation and physical connections in the UEM lab at Minnesota are described. Interface communication schemes consisting of duo server-client pairs between critical components – the optical delay stage and the UEM digital camera – are presented, with emphasis placed on describing the logic and communications sequence designed to conduct automated series acquisitions. An application designed and programmed with C++/CLI as Windows Forms in Microsoft Visual Studio – dubbed UEMtomaton – is also presented. Key to the UI layout is centralization of the automation tasks and establishment of communication within the software rather than by interfacing with each individual workstation. It is our hope that this note provides useful insight for current and future UEM researchers, particularly with respect to generalizability and portability of the approach to emerging labs. Here, we note that while this basic, entry-level approach is certainly not the most sophisticated or comprehensive of those currently in use, we feel there is nevertheless value in clearly communicating a proven straightforward method to hopefully lower the barrier to entry into the field.

47 OTHER INSTRUMENTATION↗

Ambient-pressure 151-K superconductivity in HgBa 2 Ca 2 Cu 3 O 8+δ via pressure quench

Superconductivity has been a vigorously researched topic since its discovery in 1911. Raising the superconducting transition temperature (T c ) has been the main driving force behind such long-sustained efforts due to its potential for impacting humanity and the fundamental knowledge gained from understanding this macroscopic coherent quantum state at high temperatures. The successful development of high-T c superconductivity will make possible extraordinarily efficient generation, delivery, and utilization of energy and could also enable the development of controlled fusion while impacting other burgeoning fields like quantum computation and quantum electronics. However, progress has been hindered by a longstanding plateau in the record ambient-pressure T c , unchanged since 1993. Subsequent significant advancements in T c have been achieved only under high pressures, preventing the realization of superconductivity’s full potential. To directly address this challenge, we developed a pressure-quench protocol (PQP) to stabilize pressure-induced/-enhanced superconducting states at ambient pressure. Here, we achieve a record ambient-pressure T c of 151 K in the cuprate HgBa 2 Ca 2 Cu 3 O 8+δ via PQP. The experimental results are further supported by synchrotron X-ray diffraction measurements and phonon and electronic structure calculations. This breakthrough opens avenues for stabilizing and exploring ambient-pressure high-T c superconducting states and other quantum states that have been previously only accessible under pressure, paving the way for deeper understanding and practical applications of high-T c superconductivity and beyond.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High Throughput WAN Data Transfer with Hadoop-Based Storage

Hadoop distributed file system (HDFS) is becoming more popular in recent years as a key building block of integrated grid storage solution in the field of scientific computing. Wide Area Network (WAN) data transfer is one of the important data operations for large high energy physics experiments to manage, share and process datasets of PetaBytes scale in a highly distributed grid computing environment. In this paper, we present the experience of high throughput WAN data transfer with HDFS-based Storage Element. Two protocols, GridFTP and fast data transfer (FDT), are used to characterize the network performance of WAN data transfer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of two-color EPR-entangled optical beams in macroscopic atomic ensembles

We present a protocol for deterministically producing continuous-variable Einstein-Podolsky-Rosen- (EPR-) entangled optical beams in macroscopic atomic ensembles. In contrast to previous cavity-based schemes, our protocol requires only a single pass of two coherent light beams through two spin-polarized free-space atomic vapors, which greatly simplifies the experimental implementation and makes the scheme very efficient. The two entangled modes have a frequency difference of about twice the Zeeman frequency of the atomic vapors, which can be widely tuned via magnetic-field control. Under realistic experimental conditions, we show that large entanglement could be created even with room-temperature atomic vapors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Graphical User Interface for a Biasing Board for the PSEC6

The PSEC6 is an application-specific integrated circuit (ASIC) designed for a readout system for a large area picosecond photodetector (LAPPD). The PSEC6 is currently in fabrication and pending testing. The testing system for the PSEC5, the previous iteration of the ASIC, required expensive and non-portable equipment, because the ASIC needs twelve adjustable reference voltages. The new testing system consists of an low-cost, open-source, cross-platform graphical user interface (GUI), a digital system, and a biasing board. The digital system is the interface between the GUI and biasing board, and can be implemented on a microcontroller or field-programmable gate array (FPGA). The biasing board contains twelve digital-to-analog converters (DACs) that are configurable via the GUI, which gives users the ability to write voltage values to all or specific DACs. The GUI was developed in C on Linux using the widget library GTK4 and cross-compiled for Windows compatibility. I2C and SPI protocols were implemented on an Adafruit Feather ESP32-S3 microcontroller to write commands to the DACs and PSEC6. A hardware implementation of the I2C protocol is in development on an FPGA. Since LAPPDs will be used by the Accelerator Neutrino Neutron Interaction Experiment (ANNIE) at Fermilab, the PSEC6 testing system in this internship project can potentially benefit future neutrino research. The project is relevant to the Department of Energy’s microelectronics mission, because the PSEC6 is an ASIC that will handle fast time signals arriving from the detector for readout. It also provided experience with building a cross-platform user interface, practicing digital design and implementation in hardware description language (HDL), and using simulations to inform new design iterations.

Guerrero, Sasha Camila [North Central Coll.]↗

Virtual Ultrasound Guidance for Inexperienced Operators

Medical ultrasound or echocardiographic studies are highly operator-dependent and generally require lengthy training and internship to perfect. To obtain quality echocardiographic images in remote environments, such as on-orbit, remote guidance of studies has been employed. This technique involves minimal training for the user, coupled with remote guidance from an expert. When real-time communication or expert guidance is not available, a more autonomous system of guiding an inexperienced operator through an ultrasound study is needed. One example would be missions beyond low Earth orbit in which the time delay inherent with communication will make remote guidance impractical. The Virtual Ultrasound Guidance system is a combination of hardware and software. The hardware portion includes, but is not limited to, video glasses that allow hands-free, full-screen viewing. The glasses also allow the operator a substantial field of view below the glasses to view and operate the ultrasound system. The software is a comprehensive video program designed to guide an inexperienced operator through a detailed ultrasound or echocardiographic study without extensive training or guidance from the ground. The program contains a detailed description using video and audio to demonstrate equipment controls, ergonomics of scanning, study protocol, and scanning guidance, including recovery from sub-optimal images. The components used in the initial validation of the system include an Apple iPod Classic third-generation as the video source, and Myvue video glasses. Initially, the program prompts the operator to power-up the ultrasound and position the patient. The operator would put on the video glasses and attach them to the video source. After turning on both devices and the ultrasound system, the audio-video guidance would then instruct on patient positioning and scanning techniques. A detailed scanning protocol follows with descriptions and reference video of each view along with advice on technique. The program also instructs the operator regarding the types of images to store and how to overcome pitfalls in scanning. Images can be forwarded to the ground or other site when convenient. Following study completion, the video glasses, video source, and ultrasound system are powered down and stored. Virtually any equipment that can play back video can be used to play back the program. This includes a DVD player, personal computer, and some MP3 players.

Caine, Timothy↗

Graphical User Interface for a Biasing Board for the PSEC6

The PSEC6 is an application-specific integrated circuit (ASIC) designed for a readout system for a large area picosecond photodetector (LAPPD). The PSEC6 is currently in fabrication and pending testing. The testing system for the PSEC5, the previous iteration of the ASIC, required expensive and non-portable equipment, because the ASIC needs twelve adjustable reference voltages. The new testing system consists of an low-cost, open-source, cross-platform graphical user interface (GUI), a digital system, and a biasing board. The digital system is the interface between the GUI and biasing board, and can be implemented on a microcontroller or field-programmable gate array (FPGA). The biasing board contains twelve digital-to-analog converters (DACs) that are configurable via the GUI, which gives users the ability to write voltage values to all or specific DACs. The GUI was developed in C on Linux using the widget library GTK4 and cross-compiled for Windows compatibility. I2C and SPI protocols were implemented on an Adafruit Feather ESP32-S3 microcontroller to write commands to the DACs and PSEC6. A hardware implementation of the I2C protocol is in development on an FPGA. Since LAPPDs will be used by the Accelerator Neutrino Neutron Interaction Experiment (ANNIE) at Fermilab, the PSEC6 testing system in this internship project can potentially benefit future neutrino research. The project is relevant to the Department of Energy’s microelectronics mission, because the PSEC6 is an ASIC that will handle fast time signals arriving from the detector for readout. It also provided experience with building a cross-platform user interface, practicing digital design and implementation in hardware description language (HDL), and using simulations to inform new design iterations.

Guerrero, Sasha Camila [North Central Coll.]↗

Co-optimizing water-alternating-carbon dioxide injection projects using a machine learning assisted computational framework

In this report, a robust machine-learning-based computational framework that couples multi-layer neural network (MLNN) proxies and a multi-objective particle swarm optimizer (MOPSO) to design water-alternating-carbon dioxide injection (CO 2 -WAG) projects is presented. The proposed optimization protocol considers various objectives, including oil recovery and CO 2 storage volume. Expert MLNN systems are trained and employed as surrogate models of the high-fidelity compositional simulator in the optimization workflow. When multiple objective functions are considered, two approaches are employed to treat the objectives: the weighted sum method and the Pareto-front-based scheme. A field-scale implementation focusing on tertiary recovery in the Morrow B formation at Farnsworth Unit (FWU) is presented. The developed Pareto-optimal solutions indicate the maximal available oil production can be 1.64 × 10 7 barrels and maximal carbon storage can achieve 2.35 × 10 7 tons. Trade-offs factor is defined to divide the constructed Pareto front into 4 sections with the trade-off factors’ value ranges from 0.35 to 49.9. This work also compares the optimum solution found by the aggregative objective function and the solution repository covered by the Pareto front that considers the physical and operational constraints and reduces uncertainties involved by the multi-objective optimization process. Our comparison indicates multiple solutions exist to satisfy the objective criteria of the WAG design, and these results cannot be found using the traditional weighted sum method. The Pareto front solution can provide more options for project designers, but decisions regarding necessary trade-offs must be made using the solution repository to balance the project economics and CO 2 storage amount.

10 SYNTHETIC FUELS↗

Rotating crystals of magnetic Janus colloids

Monodisperse magnetic colloids are found to self-assemble into unusual crystals in the presence of rotating magnetic fields. First, we confirm a predicted phase transition, directly coupled to the dynamic transition of single particle motion, from a disordered state to a hexagonal crystal. Next, going beyond what had been predicted, we report how hydrodynamic coupling produces shear melting, dislocations, and periodically mobile domain boundaries. Furthermore, these uniform magnetic colloids, whose structures are modulated in situ using the protocols described here, demonstrate a strategy of stimulus-response in the colloid domain with potential applications.

42 ENGINEERING↗