Stochastic template placement algorithm for gravitational wave data analysis

This paper presents an algorithm for constructing matched-filter template banks in an arbitrary parameter space. The method places templates at random, then removes those which are 'too close' together. The properties and optimality of stochastic template banks generated in this manner are investigated for some simple models. The effectiveness of these template banks for gravitational wave searches for binary inspiral waveforms is also examined. The properties of a stochastic template bank are then compared to the deterministically placed template banks that are currently used in gravitational wave data analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Artificial Intelligence Designer of Materials and Processes for Advanced Power Generation

In this presentation, ‘deep-freeze’ graphs, ‘convoluted filtering’ networks, ‘mirror-image’ graphs, and adversarial ensemble methods are utilized to support inversion modeling for optimization of the complex compositions and complex processes in design of high-performing alloys, with their properties tailored to the energy application specifications.

Romanov, Vyacheslav↗

The Thermal Expansion, Elastic and Fracture Properties of Porous Cordierite at Elevated Temperatures

The properties that determine the thermal shock resistance in materials are reported for porous cordierite, a leading candidate material for the fabrication of diesel particulate filters. Fracture toughness and slow crack growth tests were performed on test specimens obtained from the walls of diesel particulate filter monolithic substrates using the double-torsion test method at temperatures between 20 C and 900 C. The thermal expansion and elastic properties were characterized between 20 C and 1000 C. The role of the microstructure of porous cordierite in determining its unusual thermal expansion and elevated temperature Young's modulus and fracture toughness are discussed.

36 MATERIALS SCIENCE↗

SU-E-T-131: Dosimetric Impact and Evaluation of Different Heterogenity Algorithm in Volumetric Modulated Arc Therapy Plan for Stereotactic Ablative Radiotherapy Lung Treatment with the Flattening Filter Free Beam

Purpose: The present study aimed to investigate the dosimetric impacts of the anisotropic analytic algorithm (AAA) and the Acuros XB (AXB) plan for lung stereotactic ablative radiation therapy using flattening filter-free (FFF) beam. We retrospectively analyzed 10 patients. Methods: We retrospectively analyzed 10 patients. The dosimetric parameters for the target and organs at risk (OARs) from the treatment plans calculated with these dose calculation algorithms were compared. The technical parameters, such as the computation times and the total monitor units (MUs), were also evaluated. Results: A comparison of DVHs from AXB and AAA showed that the AXB plan produced a high maximum PTV dose by average 4.40% with a statistical significance but slightly lower mean PTV dose by average 5.20% compared to the AAA plans. The maximum dose to the lung was slightly higher in the AXB compared to the AAA. For both algorithms, the values of V5, V10 and V20 for ipsilateral lung were higher in the AXB plan more than those of AAA. However, these parameters for contralateral lung were comparable. The differences of maximum dose for the spinal cord and heart were also small. The computation time of AXB was found fast with the relative difference of 13.7% than those of AAA. The average of monitor units (MUs) for all patients was higher in AXB plans than in the AAA plans. These results indicated that the difference between AXB and AAA are large in heterogeneous region with low density. Conclusion: The AXB provided the advantages such as the accuracy of calculations and the reduction of the computation time in lung stereotactic ablative radiotherapy (SABR) with using FFF beam, especially for VMAT planning. In dose calculation with the media of different density, therefore, the careful attention should be taken regarding the impacts of different heterogeneity correction algorithms. The authors report no conflicts of interest.

60 APPLIED LIFE SCIENCES↗

SU-E-T-359: Measurement of Various Metrics to Determine Changes in Megavoltage Photon Beam Energy

Purpose: To examine the relationship between photon beam energy and various metrics for energy on the flattened and flattening filter free (FFF) beams generated by the Varian TrueBeam. Methods: Energy changes were accomplished by adjusting the bending magnet current ±10% from the nominal value for the 4, 6, 8, and 10 MV flattened and 6 and 10 MV FFF beams. Profiles were measured for a 30×30 cm{sup 2} field using a 2D ionization chamber array and a 3D water Scanner which was also used to measure PDDs. For flattened beams we compared several energy metrics; PDD at 10 cm depth in water (PDD(10)); the variation over the central 80% of the field (Flat); and the average of the highest reading along each diagonal divided by the CAX value, diagonal normalized flatness (FDN). For FFF beams we examined PDD(10), FDN, and the width of a chosen isodose level in a 30×30 cm{sup 2} field (W(d%)). Results: Changes in PDD(10) were nearly linear with changes in energy for both flattened and FFF beams as were changes in FDN. Changes in W(d%) were also nearly linear with energy for the FFF beams. PDD(10) was not as sensitive to changes in energy compared to the other metrics for either flattened or FFF beams. Flat was not as sensitive to changes in energy compared to FDN for flattened beams and its behavior depends on depth. FDN was the metric that had the highest sensitivity to the changes in energy for flattened beams while W(d%) was the metric that had highest sensitivity to the changes in energy for FFF beams. Conclusions: The metric FDN was found to be most sensitive to energy changes for flattened beams, while the W(d%) was most sensitive to energy changes for FFF beams.

07 ISOTOPE AND RADIATION SOURCES↗

Poster — Thur Eve — 01: The effect of the number of projections on MTF and CNR in Compton scatter tomography

Purpose: To investigate the dependence of the reconstructed image quality on the number of projections in multi-projection Compton scatter tomography (MPCST). The conventional relationship between the projection number used for reconstruction and reconstructed image quality pertained to CT does not necessarily apply to MPCST, which can produce images from a single projection if the detectors have sufficiently high energy and spatial resolution. Methods: The electron density image was obtained using filtered-backprojection of the scatter signal over circular arcs formed using Compton equation. The behavior of the reconstructed image quality as a function of the projection number was evaluated through analytical simulations and characterized by CNR and MTF. Results: The increase of the projection number improves the contrast with this dependence being a function of fluence. The number of projections required to approach the asymptotic maximum contrast decreases as the fluence increases. Increasing projection number increases the CNR but not spatial resolution. Conclusions: For MPCST using a 500eV energy resolution and a 2×2mm{sup 2} size detector, an adequate image quality can be obtained with a small number of projections provided the incident fluence is high enough. This is conceptually different from conventional CT where a minimum number of projections is required to obtain an adequate image quality. While increasing projection number, even for the lowest dose value, the CNR increases even though the number of photons per projection decreases. The spatial resolution of the image is improved by increasing the sampling within a projection rather than by increasing the number of projections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solute chemistry for streams draining geomorphic features and varying land cover gradients in the East River watershed, Colorado

This dataset contains solute chemistry data and GPS coordinates for surface water samples collected in the East River watershed in the Elk and West Elk Ranges of Colorado from August 3rd through August 11th, 2022. Samples were collected from streams and groundwater seeps as part of a comprehensive analysis within the watershed of how different geomorphic features (such as landslides and rock glaciers) along with variations in land cover (such as the presence of vegetation) affect stream water quality in this Rocky Mountain headwater environment. This dataset includes concentrations of the following in a single csv file: fluoride, chloride, sulfate, nitrate, calcium, potassium, magnesium, sodium, silicon, and total organic carbon (TOC). All concentrations are reported in mg/L. The sulfate data in this version have been updated to account for an earlier ion chromatograph instrument method error whereby sulfate and bromide peaks overlapped in calibration solution samples, biasing calculated sulfate concentrations low by 30-50%. Sulfate data reported herein are from a re-run of the samples performed in December 2024 using a corrected instrument method. All samples were stored under refrigerated conditions and filtered on initial collection.

54 ENVIRONMENTAL SCIENCES↗

Application of a Trapezoidal Filter to Waveforms from Silicone and Germanium Detectors

Application of a trapezoidal filter to data from a benchtop measurement and an experiment at DANCE is reported. The measurements were performed with a 252Cf source and sets of two and four Si detectors, respectively, recording the detectors waveforms for offline analysis. In addition, the trapezoidal filter was applied to data from an HPGe detector installed at DANCE. The parameters of the filter were optimized to provide the best energy resolution. The results of the trapezoidal filter are evaluated against the standard waveform-integration method.

47 OTHER INSTRUMENTATION↗

Machine Reading at Scale: A Search Engine for Scientific and Academic Research

The Internet, much like our universe, is ever-expanding. Information, in the most varied formats, is continuously added to the point of information overload. Consequently, the ability to navigate this ocean of data is crucial in our day-to-day lives, with familiar tools such as search engines carving a path through this unknown. In the research world, articles on a myriad of topics with distinct complexity levels are published daily, requiring specialized tools to facilitate the access and assessment of the information within. Recent endeavors in artificial intelligence, and in natural language processing in particular, can be seen as potential solutions for breaking information overload and provide enhanced search mechanisms by means of advanced algorithms. As the advent of transformer-based language models contributed to a more comprehensive analysis of both text-encoded intents and true document semantic meaning, there is simultaneously a need for additional computational resources. Information retrieval methods can act as low-complexity, yet reliable, filters to feed heavier algorithms, thus reducing computational requirements substantially. In this work, a new search engine is proposed, addressing machine reading at scale in the context of scientific and academic research. It combines state-of-the-art algorithms for information retrieval and reading comprehension tasks to extract meaningful answers from a corpus of scientific documents. The solution is then tested on two current and relevant topics, cybersecurity and energy, proving that the system is able to perform under distinct knowledge domains while achieving competent performance.

Sousa, Norberto (ORCID:0000000329194817)↗

Optimal Matched Filter in the Low-number Count Poisson Noise Regime and Implications for X-Ray Source Detection

Detection of templates (e.g., sources) embedded in low-number count Poisson noise is a common problem in astrophysics. Examples include source detection in X-ray images, γ-rays, UV, neutrinos, and search for clusters of galaxies and stellar streams. However, the solutions in the X-ray-related literature are sub-optimal in some cases by considerable factors. Using the lemma of Neyman–Pearson, we derive the optimal statistics for template detection in the presence of Poisson noise. We demonstrate that, for known template shape (e.g., point sources), this method provides higher completeness, for a fixed false-alarm probability value, compared with filtering the image with the point-spread function (PSF). In turn, we find that filtering by the PSF is better than filtering the image using the Mexican-hat wavelet (used by wavdetect). For some background levels, our method improves the sensitivity of source detection by more than a factor of two over the popular Mexican-hat wavelet filtering. This filtering technique can also be used for fast PSF photometry and flare detection; it is efficient and straightforward to implement. We provide an implementation in MATLAB. The development of a complete code that works on real data, including the complexities of background subtraction and PSF variations, is deferred for future publication.

79 ASTRONOMY AND ASTROPHYSICS↗

Low-dose preview for patient-specific, task-specific technique selection in cone-beam CT

Purpose : A method is presented for generating simulated low-dose cone-beam CT (CBCT) preview images from which patient- and task-specific minimum-dose protocols can be confidently selected prospectively in clinical scenarios involving repeat scans. Methods : In clinical scenarios involving a series of CBCT images, the low-dose preview (LDP) method operates upon the first scan to create a projection dataset that accurately simulates the effects of dose reduction in subsequent scans by injecting noise of proper magnitude and correlation, including both quantum and electronic readout noise as important components of image noise in flat-panel detector CBCT. Experiments were conducted to validate the LDP method in both a head phantom and a cadaveric torso by performing CBCT acquisitions spanning a wide dose range (head: 0.8–13.2 mGy, body: 0.8–12.4 mGy) with a prototype mobile C-arm system. After injecting correlated noise to simulate dose reduction, the projections were reconstructed using both conventional filtered backprojection (FBP) and an iterative, model-based image reconstruction method (MBIR). The LDP images were then compared to real CBCT images in terms of noise magnitude, noise-power spectrum (NPS), spatial resolution, contrast, and artifacts. Results : For both FBP and MBIR, the LDP images exhibited accurate levels of spatial resolution and contrast that were unaffected by the correlated noise injection, as expected. Furthermore, the LDP image noise magnitude and NPS were in strong agreement with real CBCT images acquired at the corresponding, reduced dose level across the entire dose range considered. The noise magnitude agreed within 7% for both the head phantom and cadaveric torso, and the NPS showed a similar level of agreement up to the Nyquist frequency. Therefore, the LDP images were highly representative of real image quality across a broad range of dose and reconstruction methods. On the other hand, naïve injection ofuncorrelated noise resulted in strong underestimation of the true noise, which would lead to overly optimistic predictions of dose reduction. Conclusions : Correlated noise injection is essential to accurate simulation of CBCT image quality at reduced dose. With the proposed LDP method, the user can prospectively select patient-specific, minimum-dose protocols (viz., acquisition technique and reconstruction method) suitable to a particular imaging task and to the user's own observer preferences for CBCT scans following the first acquisition. The method could provide dose reduction in common clinical scenarios involving multiple CBCT scans, such as image-guided surgery and radiotherapy.

60 APPLIED LIFE SCIENCES↗

Refining Principal Stress Measurements in Reservoir Underburden in Regions of Induced Seismicity through Seismological Tools, Laboratory Experiments - Final Technical Report

This project developed methodologies to measure the in-situ principal stress in the deep subsurface through use of multiple independent, but complementary, seismic methods, laboratory verification, and development of theoretical frameworks. By leveraging existing regional and local datasets we developed, tested, and refined a set of diagnostic tools for determining the in-situ stress state with reduced uncertainty at and below reservoir depths (1.5-6 km). A set of novel tools was produced that are scale independent, such that their utility is equivalent on regional, field scale, and near borehole monitoring of principal stresses in reservoir underburden for carbon storage projects. During a 4-year Department of Energy (DOE) and Southern Company funded project, carried out by the Electric Power Research Institute (EPRI), Lawrence Livermore National Laboratory (LLNL), the University of Oklahoma (OU), and the U.S. Geological Survey (USGS), the project team developed methodologies to measure the far-field in-situ principal stress in the deep subsurface, leveraging induced seismicity data from waste-water disposal projects. These methodologies consisted in the use of well-established and technically advanced seismic processing methods, such as virtual seismometer method-moment tensor (VSM-MT) and shear wave splitting (SWS), that are adept at recovering the stress orientation and certain components of the stress tensor. These methods were applied to robust seismicity catalogs created with matched filter techniques near sites of active fluid disposal—a proxy for carbon storage sites where such datasets are more limited. Estimates of the stress orientation made with seismic processing tools were considered along with laboratory acoustic emission experiments conducted on rock samples from the region of interest. Stress orientations in the studied region do not vary significantly across distances of ~100 km, nor are they found to rotate through time as a consequence of local wastewater disposal, as previously speculated. Finally, the project team investigated the trade-offs among the different seismic methods and evaluated the range of uncertainty that is generated with these methodologies, which led to a practical use and refinement of the VSM-MT technique when it is applied to field datasets. Understanding the trade-offs between these different methods highlighted the potential benefits of improved quantification of uncertainties on stress field estimations.

58 GEOSCIENCES↗

Biological Removal of Radiocarbon-14 from Irradiated Graphite

This paper reports on the preliminary study on the bioseparation of radiocarbon-14 (C-14) using a mixed-culture of microorganisms. The bioseparation principle is critically analyzed and is benchmarked against existing C-14 separation methods using physical chemical processes. The preliminary study indicated probable bio-separate of C-14 from solution prepared from a nuclear graphite mixture, even though the findings need to be verified. The current experiment consisted of a growth vessel and a bio-filter operated in a closed loop. The bio-filter was not installed for the purpose of treatment but rather as a method of isolation of microorganisms for further processing. Significant amounts of C-14 were detected in the trapped cells in the bio-filter, significantly higher than in controls taken before adding carbon sources containing C-14. The microorganisms were grown under micro-aerobic conditions with graphite carbon and commercially purchased powdered carbon as the predominant supplied carbon sources. Small amounts of sucrose (500 mg/L) were added at 48 hour intervals to maintain culture balance. A proof of concept study is underway to determine the C-14 mass balance, characterize the microorganisms in the reactor, and establish the presence or absence of processes that might have affected the preliminary observations. This research represents an exploration into a new field using a new philosophy for treatment of C-14 in low-level waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DISTANCE DETERMINATION TO 12 TYPE II SUPERNOVAE USING THE EXPANDING PHOTOSPHERE METHOD

We use early-time photometry and spectroscopy of 12 Type II plateau supernovae (SNe IIP) to derive their distances using the expanding photosphere method (EPM). We perform this study using two sets of Type II supernova (SN II) atmosphere models, three filter subsets ({l_brace}BV{r_brace}, {l_brace}BVI{r_brace}, and {l_brace}VI{r_brace}), and two methods for the host-galaxy extinction, which leads to 12 Hubble diagrams. We find that systematic differences in the atmosphere models lead to {approx}50% differences in the EPM distances and to a value of H {sub 0} between 52 and 101 km s{sup -1}Mpc{sup -1}. Using the {l_brace}VI{r_brace} filter subset we obtain the lowest dispersion in the Hubble diagram, {sigma}{sub {mu}} = 0.32 mag. We also apply the EPM analysis to the well observed SN IIP 1999em. With the {l_brace}VI{r_brace} filter subset we derive a distance ranging from 9.3 {+-} 0.5 Mpc to 13.9 {+-} 1.4 Mpc depending on the atmosphere model employed.

79 ASTRONOMY AND ASTROPHYSICS↗

Enzyme entrapped nanoporous scaffolds formed through flow induced gelation in microfluidic filter device for sensitive biosensing of organophosphorus compounds

A novel and versatile processing method was developed for the formation of gel scaffolds with in-situ AChE-AuNPs immobilization for biosensing of organophosphorus compounds. The biosensor designed by our new approach shows high sensitivity, selectivity and reactivation efficiency. This flow induced immobilziation technique opens up new pathways for designing simple, fast, biocompatible, and cost-effective process for enhanced sensor performance and on-site testing of a variety of toxic organophosphorus compounds.

47 OTHER INSTRUMENTATION↗

Porous block nanofiber composite filters

Porous block nano-fiber composite (110), a filtration system (10) and methods of using the same are disclosed. An exemplary porous block nano-fiber composite (110) includes a porous block (100) having one or more pores (200). The porous block nano-fiber composite (110) also includes a plurality of inorganic nano-fibers (211) formed within at least one of the pores (200).

36 MATERIALS SCIENCE↗

Toward improving drought monitoring using the remotely sensed soil moisture assimilation: A parallel particle filtering framework

Drought is the costliest hazard among all natural disasters. Despite the significant improvements in drought modeling over the last decade, accurate provisions of drought conditions in a timely manner is still one of the major research challenges. In order to improve the current drought monitoring skills, this study presents a land data assimilation system by merging the remotely sensed surface soil moisture with the use of recently developed particle Markov chain Monte Carlo (PMCMC) method. To cope with the computational complexity, a modular parallel particle filtering framework (PPFF) is developed which allows a large ensemble size in PMCMC applications. The implementation of the proposed system is demonstrated with the 2012 summer flash drought case study over the Contiguous United States (CONUS). Results from both synthetic and real case studies suggest that the land data assimilation system significantly improves the soil moisture predictions and the drought monitoring skills. Compared with the U.S. Drought Monitoring (USDM), the land data assimilation can better capture the drought onset on May 2012 and the drought severity in June and July 2012. Finally, this study recommends that the proposed land data assimilation system under a high-performance computing (HPC) infrastructure can better facilitate the drought preparation and response actions.

42 ENGINEERING↗

A H-infinity Fault Detection and Diagnosis Scheme for Discrete Nonlinear System Using Output Probability Density Estimation

In this paper, a H-infinity fault detection and diagnosis (FDD) scheme for a class of discrete nonlinear system fault using output probability density estimation is presented. Unlike classical FDD problems, the measured output of the system is viewed as a stochastic process and its square root probability density function (PDF) is modeled with B-spline functions, which leads to a deterministic space-time dynamic model including nonlinearities, uncertainties. A weighting mean value is given as an integral function of the square root PDF along space direction, which leads a function only about time and can be used to construct residual signal. Thus, the classical nonlinear filter approach can be used to detect and diagnose the fault in system. A feasible detection criterion is obtained at first, and a new H-infinity adaptive fault diagnosis algorithm is further investigated to estimate the fault. Simulation example is given to demonstrate the effectiveness of the proposed approaches.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗