Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

A new sawtooth control mechanism relying on toroidally propagating ion cyclotron resonance frequency waves: Theory and Joint European Torus tokamak experimental evidence

The sawtooth control mechanism in plasmas employing toroidally propagating ion cyclotron resonance waves is extended. The asymmetrically distributed energetic passing ions are shown to modify the ideal internal kink mode when the position of the minority ion cyclotron resonance resides within a narrow region close to the q=1 surface. An analytical treatment of the internal kink mode in the presence of model distribution function with parallel velocity asymmetry is developed. The fast ion mechanism explains the strong sensitivity of sawteeth to resonance position, and moreover is consistent with dedicated Joint European Torus [F. Romanelli, Nucl. Fusion 49, 104006 (2009)] experiments which controlled sawteeth despite negligible current drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hierarchical Power Flow Control in Smart Grids: Enhancing Rotor Angle and Frequency Stability with Demand-Side Flexibility

Large-scale integration of renewables in power systems gives rise to new challenges for keeping synchronization and frequency stability in volatile and uncertain power flow states. To ensure the safety of operation, the system must maintain adequate disturbance rejection capability at the time scales of both rotor angle and system frequency dynamics. This calls for flexibility to be exploited on both the generation and demand sides, compensating volatility and ensuring stability at the two separate time scales. This article proposes a hierarchical power flow control architecture that involves both transmission and distribution networks as well as individual buildings to enhance both small-signal rotor angle stability and frequency stability of the transmission network. The proposed architecture consists of a transmission-level optimizer enhancing system damping ratios, a distribution-level controller following transmission commands and providing frequency support, and a building-level scheduler accounting for quality of service and following the distribution-level targets. Furthermore, we validate the feasibility and performance of the whole control architecture through real-time hardware-in-loop tests involving real-world transmission and distribution network models along with real devices at the Stone Edge Farm Microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An a priori DNS study of the shadow-position mixing model

In this study, the modeling of mixing by molecular diffusion is a central aspect for transported probability density function (tPDF) methods. In this paper, the newly-proposed shadow position mixing model (SPMM) is examined, using a DNS database for a temporally evolving di-methyl ether slot jet flame. Two methods that invoke different levels of approximation are proposed to extract the shadow displacement (equivalent to shadow position) from the DNS database. An approach for a priori analysis of the mixing-model performance is developed. The shadow displacement is highly correlated with both mixture fraction and velocity, and the peak correlation coefficient of the shadow displacement and mixture fraction is higher than that of the shadow displacement and velocity. This suggests that the composition-space localness is reasonably well enforced by the model, with appropriate choices of model constants. The conditional diffusion of mixture fraction and major species from DNS and from SPMM are then compared, using mixing rates that are derived by matching the mixture fraction scalar dissipation rates. Good qualitative agreement is found, for the prediction of the locations of zero and maximum/minimum conditional diffusion locations for mixture fraction and individual species. Similar comparisons are performed for DNS and the IECM (interaction by exchange with the conditional mean) model. The agreement between SPMM and DNS is better than that between IECM and DNS, in terms of conditional diffusion iso-contour similarities and global normalized residual levels. It is found that a suitable value for the model constant c that controls the mixing frequency can be derived using the local normalized scalar variance, and that the model constant a controls the localness of the model. A higher-Reynolds-number test case is anticipated to be more appropriate to evaluate the mixing models, and stand-alone transported PDF simulations are required to more fully enforce localness and to assess model performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of Commercial Building Lighting as a Frequency Regulation Resource

This paper evaluates the potential for automated lighting control as a resource for frequency regulation of the electric grid system in the context of current energy policies, economic incentives, and technological trends. The growing prevalence of renewable energy has increased the need for ancillary services to maintain grid frequency and stability. While demand side resources like heating, ventilating, and air-conditioning systems, as well as water treatment plants are already evaluated as regulation service providers, the potential application to electrical lighting systems has largely been ignored. Yet, aggregations of lighting systems that are retrofitted with intelligent controls could conceivably contribute to frequency regulation services with little impact on user comfort. To further explore the feasibility of lighting potential, this paper explores (1) how lighting control systems are limited by visual comfort perception and acceptability, (2) how such limitations impact the performance of the lighting system as an frequency regulation resource, and (3) how the market potential of lighting systems as demand side resources compares in different regional transmission organizations. Finally, the impact of developing technologies on the application of lighting systems for frequency regulation is discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bounded Universal Droop Control to Enable the Operation of Power Inverters Under Some Abnormal Conditions and Maintain Voltage and Frequency Within Predetermined Ranges

The universal droop control (UDC) can be applied to power inverters having an impedance angle between -pi/2 rad and pi/2 rad to achieve voltage and frequency regulation and accurate proportional power sharing without the need of knowing the type or value of impedance. However, there is an increasing need for voltage and frequency regulation within predetermined ranges even under some abnormal conditions, such as overloading, sensor faults, and large set-point changes, etc. In this paper, a bounded nonlinear dynamics is introduced into the UDC to ensure that the voltage and frequency can always stay within predetermined ranges under normal and some abnormal conditions, up to hardware limits when current protection needs to be triggered. As a result, the proposed controller can extend the operational range of power inverters in terms of voltage and frequency regulation to cover different scenarios. More importantly, the ranges for both voltage and frequency can be chosen independently from each other. Since the original structure of the UDC is kept in the proposed controller, the properties of the UDC, such as without the need of knowing the type or value of impedance, are well maintained. Furthermore, the closed-loop stability of the system is established via the Lyapunov method. Extensive simulation and experimental results are presented to validate the effectiveness of the proposed controller.

14 SOLAR ENERGY↗

Advanced Grid Support Functionality Testing for Florida Power and Light

This report describes the results of laboratory testing of advanced photovoltaic (PV) inverter testing undertaken by the National Renewable Energy Laboratory (NREL) on behalf of the Florida Power and Light Company (FPL). FPL recently commissioned a 1.1 MW-AC PV installation on a solar carport at the Daytona International Speedway in Daytona Beach, Florida. In addition to providing a source of clean energy production, the site serves as a live test bed with 36 different PV inverters from eight different manufacturers. Each inverter type has varied support for advanced grid support functions (GSFs) that are becoming increasingly commonplace, and are being required through revised interconnection standards such as UL1741, IEEE1547, and California (CA) Rule 21. FPL is interested in evaluating the trade-offs between different GSFs, their compliance to emerging standards, and their effects on efficiency and reliability. NREL has provided a controlled laboratory environment to undertake such a study. This work covered nine different classes of tests to compare inverter capabilities and performance for four different inverters that were selected by FPL. The test inverters were all three-phase models rated between 24-36 kW, and containing multiple PV input power point trackers. Advanced grid support functions were tested for functional behavior, and included fixed power factor operation, voltage-ride through, frequency ride-through, volt-var control, and frequency-Watt control. Response to abnormal grid conditions with GSFs enabled was studied through anti-islanding, fault, and load rejection overvoltage tests. Finally, efficiency was evaluated across a range of operating conditions that included power factor, output power, and input voltage variations. Test procedures were derived from requirements of a draft revision of UL741, CA Rule 21, and/or previous studies at NREL. This reports summarizes the results of each test case, providing a comparative performance analysis between the four test inverters. Inverters were mostly able to meet the requirements of their stated GSF capabilities, with deviations from expected results discussed throughout the report. There were mixed results across the range of abnormal tests, and results were often dependent on the capability of each test inverter to deploy the GSFs of interest. Detailed test data has been provided to FPL to support future decision making with respect to inverter selection and GSF deployment in the field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling of flexible structures for active control

If a flexible structure has a plane of symmetry, the equations of motion can be split into two uncoupled sets, one for symmetrical motions and one for anti-symmetric motions. If there are m controls, it is often convenient to assign the linear combinations of controls that enter into the m lowest frequency modes and new controls. As an example the feed-support structure of a spacecraft antenna is considered. It is modeled as a tetrahedron made up of flexible bars and connected to the spacecraft by six short flexible legs containing force actuators and displacement sensors. Due to the three-sided symmetry of this structure, both the symmetric and the anti-symmetric equations of motion can be decoupled into two subsystems. The resulting four subsystems are: (1) pitch/fore-aft motions with four degrees of freedom (DOF), two controls, and one output (the fore-aft motion of the feed); (2) vertical motions with three DOF, one control, and one output (the vertical motion of the feed); (3) roll/lateral motions with four DOF, two controls, and one output (the lateral motions of the feed); and (4) yaw motion with one DOF, one control, and no output (the feed does not move during yaw motion).

Bryson, A. E., Jr.↗

Enabling Grid-Forming Control Under Unbalanced Conditions

Standalone microgrids often experience unbalanced loading and faults, which can cause grid-forming control designed for balanced conditions to produce oscillatory responses. To address this issue, a compact time-domain transformation appropriate for inverter control is proposed, allowing the conversion of unbalanced three-phase signals to positive and negative synchronous reference frames. This transformation supports the development of a grid-forming control with fault ride-through, featuring frequency and voltage droop controllers and nested current and voltage control loops that seamlessly integrate an enhanced current limiter. The effectiveness of the proposed control and transformation is demonstrated through analytical results and electromagnetic transient simulation.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Optimal active vibration absorber: Design and experimental results

An optimal active vibration absorber can provide guaranteed closed-loop stability and control for large flexible space structures with collocated sensors/actuators. The active vibration absorber is a second-order dynamic system which is designed to suppress any unwanted structural vibration. This can be designed with minimum knowledge of the controlled system. Two methods for optimizing the active vibration absorber parameters are illustrated: minimum resonant amplitude and frequency matched active controllers. The Controls-Structures Interaction Phase-1 Evolutionary Model at NASA LaRC is used to demonstrate the effectiveness of the active vibration absorber for vibration suppression. Performance is compared numerically and experimentally using acceleration feedback.

Lee-Glauser, Gina↗

Optimal active vibration absorber - Design and experimental results

An optimal active vibration absorber can provide guaranteed closed-loop stability and control for large flexible space structures with collocated sensors/actuators. The active vibration absorber is a second-order dynamic system which is designed to suppress any unwanted structural vibration. This can be designed with minimum knowledge of the controlled system. Two methods for optimizing the active vibration absorber parameters are illustrated: minimum resonant amplitude and frequency matched active controllers. The Controls-Structures Interaction Phase-1 Evolutionary Model at NASA LaRC is used to demonstrate the effectiveness of the active vibration absorber for vibration suppression. Performance is compared numerically and experimentally using acceleration feedback.

Lee-Glauser, Gina↗

Active control of the forced and transient response of a finite beam

Structural vibrations from a point force are modelled on a finite beam. This research explores the theoretical limit on controlling beam vibrations utilizing another point source as an active controller. Three different types of excitation are considered, harmonic, random, and transient. For harmonic excitation, control over the entire beam length is possible only when the excitation frequency is near a resonant frequency of the beam. Control over a subregion may be obtained even between resonant frequencies at the cost of increasing the vibration outside of the control region. For random excitation, integrating the expected value of the displacement squared over the required interval, is shown to yield the identical cost function as obtained by integrating the cost function for harmonic excitation over all excitation frequencies. As a result, it is always possible to reduce the cost function for random excitation whether controlling the entire beam or just a subregion, without ever increasing the vibration outside the region in which control is desired. The last type of excitation considered is a single, transient pulse. The form of the controller is specified as either one or two delayed pulses, thus constraining the controller to be casual. The best possible control is examined while varying the region of control and the controller location. It is found that control is always possible using either one or two control pulses.

Post, John T.↗

Self-organised aggregation of a pair of particles with different resonant frequencies and electric dipole moments of transitions, controlled by an external quasi-resonant field

The influence of the oscillation phases of the dipole moments induced in metal nanoparticles and quantum dots by an external laser field on their interaction energy is considered. It is shown that a difference in resonant frequencies leads to the formation of additional minima and maxima, which are absent in the spectral dependence of the interaction energy of identical particles at similar orientations of the pair of particles with respect to the plane of polarisation of radiation. These features are due to the fact that the oscillation phase difference of the induced dipole moments of particles reaches values close to {pi}. (interaction of laser radiation with matter. laser plasma)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamic frequency tuning of electric and magnetic metamaterial response

A geometrically modifiable resonator is comprised of a resonator disposed on a substrate, and a means for geometrically modifying the resonator. The geometrically modifiable resonator can achieve active optical and/or electronic control of the frequency response in metamaterials and/or frequency selective surfaces, potentially with sub-picosecond response times. Additionally, the methods taught here can be applied to discrete geometrically modifiable circuit components such as inductors and capacitors. Principally, controlled conductivity regions, using either reversible photodoping or voltage induced depletion activation, are used to modify the geometries of circuit components, thus allowing frequency tuning of resonators without otherwise affecting the bulk substrate electrical properties. The concept is valid over any frequency range in which metamaterials are designed to operate.

42 ENGINEERING↗

A Medium Voltage Three-Stage Power Converter Topology for Distribution Grid Scale Energy Storage Systems

This work proposes a three-stage converter topology with a medium frequency isolation transformer for direct integration of energy storage systems into medium voltage distribution grids. The distributed architecture of the topology, using standard AC/DC converters, has been developed with the aim of plug-and-play capability and voltage and power scalability. The medium frequency transformer facilitates improved power density, while its 20:1 voltage translation capability enables the use of limited voltage level (500 Vdc) of the commercially available batteries. This paper presents the topology structure and details how it can be scaled to reach the full range of the distribution grid voltages and the required power levels. A transformer design for 500 Hz rated frequency is discussed. The control scheme of the converter equipped with voltage support, frequency support, and black start capabilities is also presented. Control hardware-in-the-loop results using OPAL-RT, with converter switching models connected to a weak IEEE-4 node test feeder modified for the aforementioned grid services, are provided to show the topology feasibility.

Chinthavali, Madhu Sudhan↗

Models and Methods for Assessing the Value of HVDC and MVDC Technologies in Mondern Power Grids

Evolution of today’s predominantly alternating current (ac) transmission grid in to mixed ac transmission – high-voltage direct current (HVdc) systems is expected with the decreasing costs of and advancements in power electronics technologies. The recent technological advancements include the development of more efficient and compact voltage source converters (VSCs) that can provide fast response. Because of their controllability and fast response, HVdc systems provide the ability to enhance reliability of the ac transmission grid through frequency support, voltage control, and congestion relief. The HVdc systems can also provide other ancillary services to enhance the economics and reliability of the ac transmission grids, and to optimize their performance. The tools, models, and methods developed to evaluate their benefits will be key enablers to understanding the value proposition introduced by the fast-acting HVdc systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Steering of Frequency Standards by the Use of Linear Quadratic Gaussian Control Theory

Linear quadratic Gaussian control is a technique that uses Kalman filtering to estimate a state vector used for input into a control calculation. A control correction is calculated by minimizing a quadratic cost function that is dependent on both the state vector and the control amount. Different penalties, chosen by the designer, are assessed by the controller as the state vector and control amount vary from given optimal values. With this feature controllers can be designed to force the phase and frequency differences between two standards to zero either more or less aggressively depending on the application. Data will be used to show how using different parameters in the cost function analysis affects the steering and the stability of the frequency standards.

Koppang, Paul↗

PWM Switching Frequency Effects on Eddy Current Sensors for Magnetically Suspended Flywheel Systems

A flywheel magnetic bearing (MB) pulse width modulated power amplifier (PWM) configuration is selected to minimize noise generated by the PWMs in the flywheel position sensor system. Two types of noise are addressed: beat frequency noise caused by variations in PWM switching frequencies, and demodulation noise caused by demodulation of high order harmonics of the switching voltage into the MB control band. Beat frequency noise is eliminated by synchronizing the PWM switch frequencies, and demodulation noise is minimized by selection of a switching frequency which does not have harmonics at the carrier frequency of the sensor. The recommended MB PWM system has five synchronized PWMs switching at a non-integer harmonic of the sensor carrier.

Jansen, Ralph↗

Battery inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 30 kW off-the-shelf grid following battery inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗