Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

The imaging of extra-galactic low-energy gamma-ray sources prospects, techniques, and instrumentation

Improved understanding of the nature of active galaxies will require detailed observations of 10 to 20 sources, while understanding of their gamma ray luminosity function and its evolution will require the detection of approximately 100 sources. Instruments capable of detecting 100 active galaxies at low-energy, gamma ray energies are achievable. The angular resolution of an instrument, as well as its sensitivity, can limit the number of sources it can observe. An investigation of the angular resolution requirements for future low-energy gamma ray instruments is presented. It was found that the strictest requirements arise not from the need to resolve detectable sources, but from the need to control the level of direction-to-direction fluctuations in the diffuse background level. It was concluded that gamma-ray instruments capable of detecting 100 active galaxies must have sub-degree angular resolution. The use of the coded aperture imaging technique is proposed as a method of achieving accurate control of systematic errors and fine angular resolution without unduly increasing the time needed to conduct full sky surveys. An analysis of coded aperture imaging is presented for instruments that employ masks based on hexagonal uniformly redundant arrays. An instrument, the gamma-ray imaging payload, was built that employs these imaging techniques. The design and testing of the instrument is described in detail. Preliminary results from a balloon flight of the instruments are shown, demonstrating its imaging performance.

Finger, Mark Harold↗

Optical Design of the RAISE Sounding Rocket Instrument

The Rapid Acquisition Imaging Spectrograph Experiment (RAISE) is a recently selected sounding rocket program to investigate the dynamics and heating of the outer solar atmosphere on time scales as short as looms. Its optical design represents the first in a new class of two-reflection W / E W imaging spectrometers with Toroidal Varied-Line Space (TVLS) gratings. Due to the remarkable imaging properties of such gratings, RAISE will measure spectra simultaneously over four different wavelength bands (1205-1243 & 1524-1559 A in first order, 602.5-621.5 & 762.0-779.5 A in second), with an unprecedented combination of spatial, spectral, and temporal resolutions. These spectral regions include many bright, well-resolved lines covering the temperature range from the low chromosphere up to the 2 MK Fe XI1 corona. The RAISE optical design features an extremely fast beam (f/7.0) and a minimum number of reflections, which together allow enough throughput to provide high quality spectral data even at its very short exposure times. Moreover, by operating with high magnification (x4.25), the RAISE spectrometer can most effectively utilize the full length and width available in the sounding rocket payload. First launch of this exciting new instrument is scheduled for 2006 June 21.

Thomas, Roger J.↗

Uncertainty identification in mass estimation applications with imaging detectors

Mass quantification using standoff gamma imaging techniques is a boon to the special nuclear material holdup monitoring community, but before the method is deemed acceptable as a replacement for historical gamma detection-based methods, there are several considerable sources of uncertainty that must be addressed. These uncertainty sources have received sparse coverage in the literature, but provide the bulk of the uncertainty estimated in practice outside of standard counting statistics. For imaging, there is a fundamental difference between detection/localization and mass estimation operating modalities, where detection/localization can tolerate significantly larger uncertainty because the goal is detection of a distant source, rather than the quantification of that source. Historically, quantification requires a known geometry between source and detector, as well as a calibrated efficiency correction curve, which is well suited to laboratory practice for a stationary detector; however, this requires some corrections and assumptions (e.g., generalized geometry) for field applications, since additional degrees of freedom are present in the source-to-detector position, intervening materials, and non-uniform source distributions, when compared against the laboratory case. Use of an imaging detector during holdup measurements would address these issues by calculating the spatial geometry of the distant source as seen by the detector, with efficiency corrected according to the source-to-detector angle. While this aim promises a better estimation accuracy than generalized geometry assumptions, additional uncertainties are added from the imaging mechanism itself. Of these uncertainties, some are readily mitigated and methods to do so are included in the discussion, while some uncertainties are specific to the imaging class of instruments and are investigated and discussed in detail. Uncertainties are categorized into two general areas: instrument design and algorithmic. Instrument design-based uncertainties include basic detector characteristics for timing and energy resolution, handling of list mode data for coincidence detection, and geometric layout of and propagation of spatial uncertainty into imaging uncertainty. Algorithmic-based uncertainties discussed herein pertain to image reconstruction, the weight assignment problem from cone interactions, and the effects of spatial discretization on mass estimation. With these major sources of uncertainty identified, the path towards acceptance of imaging as a holdup monitoring method becomes clearer.

61 RADIATION PROTECTION AND DOSIMETRY↗

An Overview of MODIS On-orbit Operation, Calibration, and Lessons

Two nearly identical copies of the Moderate Resolution Imaging Spectroradiometer (MODIS) have successfully operated onboard the Terra and Aqua spacecraft for more than II years and 9 years since their launch in December 1999 and May 2002, respectively. MODIS is a key instrument for the NASA's Earth Observing System (EOS) missions. MODIS observations have produced an unprecedented amount and a broad range of data products and significantly benefited the science and user community. Its follow-on instrument, the Visible/Infrared Imager Radiometer Suite (VIIRS) on-board the NPOESS Preparatory Project (NPP) spacecraft, is currently scheduled for launch in late October, 2011. The NPP serves as a bridge mission between EOS and the Joint Polar Satellite System (JPSS). MODIS collects data in 36 spectral bands, covering spectral regions from visible (VIS) to long-wave infrared (L WIR), and at three different spatial resolutions. Because of its stringent design requirements, MODIS was built with a complete set of onboard calibrators, including a solar diffuser (SO), a solar diffuser stability monitor (SDSM), a blackbody (BB), a spectroradiometric calibration assembly (SRCA), and a space view (SV) port. Except for tbe SRCA, VIlRS carries the same set of onboard calibrators as MODIS. The SD/SDSM system is used together to calibrate tbe reflective solar bands (RSB). The BB is designed for the thermal emissive bands (TEB) calibration. Similar to Terra and Aqua MODIS, VIlRS will also make regular lunar observations to monitor RSB radiometric calibration stability. In this paper, we provide an overview of MODIS on-orbit operation and calibration activities and present issues identified and lessons learned from mission-long instrument operations and implementation of various calibration and characterization strategies. Examples of both Terra and Aqua MODIS instrument on-orbit performance, including their similarities and unique characteristics, are discussed in tbe context of what might be expected from and benefited to tbe NPP VIlRS operation and calibration. It is anticipated that MODIS experience and lessons will also provide valuable information for other earth observing missions/sensors.

Xiong, Jack↗

Astronomy and astrophysics with the Advanced X-ray Astrophysics Facility

The optics and instruments of the Advanced X-ray Astrophysics Facility (AXAF) are described. The instrument capabilities are reviewed so that potential users of AXAF may plan supporting research in the years prior to launch. The AXAF is to be built around a large-area high-resolution grazing-incidence X-ray telescope, with a complement of imaging and spectroscopic instruments which can be maintained and/or replaced in orbit. An important feature of the AXAF is the aspect system. It utilizes solid state star cameras and fiducial lights to permit both image reconstruction (on the ground) with minimal blurring due to spacecraft and internal motions, and placement of the X-ray image on the sky to an accuracy of 1 arcsec.

Weisskopf, Martin C.↗

Development and Characterization of a High-Energy Neutron Time-of-Flight Imaging System

We present that Los Alamos National Laboratory has developed a prototype of a high-energy neutron time-of-flight imaging system for the non-destructive evaluation of dense, massive, and/or high atomic number objects. High-energy neutrons provide the penetrating power, and thus the high dynamic range necessary to image internal features and defects of such objects. The addition of the time gating capability allows for scatter rejection when paired with a pulsed monoenergetic beam, or neutron energy selection when paired with a pulsed broad-spectrum neutron source. The Time Gating to Reject Scatter and Select Energy (TiGReSSE) system was tested at the Los Alamos Neutron Science Center’s (LANSCE) Weapons Nuclear Research (WNR) facility, a spallation neutron source, to provide proof of concept measurements and to characterize the instrument response. This paper will show results of several objects imaged during this run cycle. In addition, results from system performance metrics such as the Modulation Transfer Function and the Detective Quantum Efficiency measured as a function of neutron energy, characterize the current system performance and inform the next generation of neutron imaging instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fundamentals of Materials, Techniques, and Instrumentation for OSL and FNTD Dosimetry

The optically stimulated luminescence (OSL) technique has already become a successful commercial tool in personal radiation dosimetry, medical dosimetry, diagnostic imaging, geological and archeological dating. This review briefly describes the history and fundamental principles of OSL materials, methods and instrumentation. The advantages of OSL technology and instrumentation in comparison with thermoluminescent technique are analyzed. Progress in material and detector engineering has allowed new and promising developments regarding OSL applications in the medical field. Special attention is dedicated to Al{sub 2}O{sub 3}:C as a material of choice for many dosimetric applications. Different aspects of OSL theory, materials optical and dosimetric properties, instrumentation, and data processing algorithms are described. The next technological breakthrough was done with Fluorescent Nuclear Track Detectors (FNTD) that have some important advantages in measuring fast neutron and high energy heavy charge particles that have become the latest tool in radiation therapy. New Mg-doped aluminum oxide crystals and novel type of imaging instrumentation for FNTD technology are discussed with regard to application in mixed neutron-gamma fields, medical dosimetry and radiobiological research.

61 RADIATION PROTECTION AND DOSIMETRY↗

System Developed for Bulk Flow Imaging of a Two-Phase Fluid in a Cylindrical Couette

The Microgravity Observation of Bubble Interactions (MOBI) experiment is working to better understand the physics of gas-liquid suspensions. To study such suspensions, researchers generate bubbles in a large cylindrical flow channel. Then, they use various types of instrumentation, including video imaging, to study the bubbly suspension. Scientists will need a camera view of the majority of the gas-liquid suspension inside of the couette in order to gather the information needed from the MOBI experiment. This will provide the scientists with a qualitative picture of the flow that may indicate flow instabilities or imperfect axial mixing inside the couette. These requirements pose a significant challenge because the imaging and lighting system must be confined to a very tight space since the space available on the International Space Station experiment racks is very limited. In addition, because of the large field of view needed and the detail needed to see the gas-liquid suspension behavior in the image, a digital video camera with high resolution (1024 by 1024 pixels) had to be used. Although the high-resolution camera will provide scientists with the image quality they need, it left little space on the experiment rack for the lighting system. Many configurations were considered for the lighting system, including front-lighting and back-lighting, but because of mechanical design limitations with the couette, back-lighting was not an option.

Juergens, Jeffrey R.↗

PE-46 The Design of the Lynx X-Ray Microcalorimeter

Lynx is an x-ray telescope, one of four large satellite mission concepts currently being studied by NASA to be the next astrophysics flagship mission after WFIRST. One of Lynx's three instruments is an imaging spectrometer consisting of an x-ray microcalorimeter behind an X-ray optic with an angular resolution of 0.5 arc-seconds and approximately 3 sq m of area at 1 keV. This instrument will provide unparalleled diagnostics of distant extended structures and in particular will allow the detailed study of the role of cosmic feedback in the evolution of the Universe. We discuss the design and read-out of the of the array configuration including a number of sub-array options for increasing the capabilities to maximize the scientific return of the Lynx observatory.

Bandler, Simon↗

Active wavefront correction in large telescopes

Astronomical progress with the MMT telescope, which attains high-resolution imaging by partial compensation for atmospheric distortion, is discussed. The small tertiary and beam combiner mirrors at the MMT bring six images to a common focus, where there is a TV system for acquisition and guiding. Individual image positions can be controlled by stepper motors driving actuators on the secondaries, each step moving an image 0.05 arc seconds in the focal plane. The instrument's correction for image jiggle due to atmospheric turbulence and drift of the relative positions of the images due to gravitational and thermal effects on the structure are described. A scheme for correcting residual structural errors is discussed. It appears that the telescope can work to about the 17th visual magnitude. For faint sky limited objects comparable performance would require a perfectly rigid single mirror of the same aperture to have 50 percent more collecting area and cost at least 1.5 times more.

Angel, J. R. P.↗

Lineshape spectroscopy with a very high resolution, very high signal-to-noise crystal spectrometer

We have developed a high-resolution x-ray spectrometer for measuring the shapes of spectral lines produced from laser-irradiated targets on the Orion laser facility. The instrument utilizes a spherically bent crystal geometry to spatially focus and spectrally analyze photons from foil or microdot targets. The high photon collection efficiency resulting from its imaging properties allows the instrument to be mounted outside the Orion chamber, where it is far less sensitive to particles, hard x-rays, or electromagnetic pulses than instruments housed close to the target chamber center in ten-inch manipulators. Moreover, Bragg angles above 50° are possible, which provide greatly improved spectral resolution compared to radially viewing, near grazing-incidence crystal spectrometers. These properties make the new instrument an ideal lineshape diagnostic for determining plasma temperature and density. We describe its calibration on the Livermore electron beam ion trap facility and present spectral data of the K-shell emission from highly charged sulfur produced by long-pulse as well as short-pulse beams on the Orion laser in the United Kingdom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Integrated Optimal Estimation Approach to Spitzer Space Telescope Focal Plane Survey

This paper discusses an accurate and efficient method for focal plane survey that was used for the Spitzer Space Telescope. The approach is based on using a high-order 37-state Instrument Pointing Frame (IPF) Kalman filter that combines both engineering parameters and science parameters into a single filter formulation. In this approach, engineering parameters such as pointing alignments, thermomechanical drift and gyro drifts are estimated along with science parameters such as plate scales and optical distortions. This integrated approach has many advantages compared to estimating the engineering and science parameters separately. The resulting focal plane survey approach is applicable to a diverse range of science instruments such as imaging cameras, spectroscopy slits, and scanning-type arrays alike. The paper will summarize results from applying the IPF Kalman Filter to calibrating the Spitzer Space Telescope focal plane, containing the MIPS, IRAC, and the IRS science Instrument arrays.

optimal estimations↗

NASA Tech Briefs, November 2004

Topics include: Multifunction Imaging and Spectroscopic Instrument; Position-Finding Instrument Built Around a Magnetometer; Improved Measurement of Dispersion in an Optical Fiber; Probe for Sampling of Interstitial Fluid From Bone; Neuropsychological Testing of Astronauts; Method of Calibration for a Large Cathetometer System; Four-Channel PC/104 MIL-STD-1553 Circuit Board; Improved Method of Locating Defects in Wiring Insulation; Strobe Traffic Lights Warn of Approaching Emergency Vehicles; Improved Timing Scheme for Spaceborne Precipitation Radar; Concept for Multiple-Access Free-Space Laser Communications; Variable Shadow Screens for Imaging Optical Devices; Verifying Diagnostic Software; Initial Processing of Infrared Spectral Data; Activity-Centric Approach to Distributed Programming; Controlling Distributed Planning; New Material for Surface-Enhanced Raman Spectroscopy; Treated Carbon Nanofibers for Storing Energy in Aqueous KOH; Advanced Infant Car Seat Would Increase Highway Safety; Development of Biomorphic Flyers; Second-Generation Six-Limbed Experimental Robot; Miniature Linear Actuator for Small Spacecraft; Process for Making Single-Domain Magnetite Crystals; A New Process for Fabricating Random Silicon Nanotips; Resin-Transfer-Molding of a Tool Face; Improved Phase-Mask Fabrication of Fiber Bragg Gratings; Tool for Insertion of a Fiber-Optic Terminus in a Connector; Nanofluidic Size-Exclusion Chromatograph; Lightweight, Low-CTE Tubes Made From Biaxially Oriented LCPs; Using Redundancy To Reduce Errors in Magnetometer Readings; Compact Instrument for Measuring Profile of a Light Beam; Multilayer Dielectric Transmissive Optical Phase Modulator; Second-Generation Multi-Angle Imaging Spectroradiometer; Real-Time Adaptive Color Segmentation by Neural Networks; Research and Development in Optical Communications; Tests of Multibeam Scintillation Mitigation on Laser Uplinks; and Spaceborne Infrared Atmospheric Sounder.

Source record↗

Sunspot observations from the SOUP instrument on Spacelab 2

A series of white light images obtained by the SOUP instrument on Spacelab 2 of active region 4682 on August 5, 1985 were analyzed in the area containing sunspots. Although the umbra of the spot is underexposed, the film is well exposed in the penumbral regions. These data were digitally processed to remove noise and to separate p-mode oscillations from low velocity material motions. The results of this preliminary investigation include: (1) proper motion measurements of a radial outflow in the photospheric granulation pattern just outside the penumbra; (2) discovery of occasional bright structures (streakers) that appear to be ejected outward from the penumbra; (3) broad dark clouds moving outward in the penumbra in addition to the well known bright penumbral grains moving inward; (4) apparent extensions and contractions of penumbral filaments over the photosphere; and (5) observation of a faint bubble or loop-like structure which seems to expand from two bright penumbral filaments into the photosphere.

Shine, R. A.↗

Retrievals of Aerosol Optical and Microphysical Properties from Imaging Polar Nephelometer Scattering Measurements

A method for the retrieval of aerosol optical and microphysical properties from in situ light-scattering measurements is presented and the results are compared with existing measurement techniques. The Generalized Retrieval of Aerosol and Surface Properties (GRASP) is applied to airborne and laboratory measurements made by a novel polar nephelometer. This instrument, the Polarized Imaging Nephelometer (PI-Neph), is capable of making high-accuracy field measurements of phase function and degree of linear polarization, at three visible wavelengths, over a wide angular range of 3 to 177°. The resulting retrieval produces particle size distributions (PSDs) that agree, within experimental error, with measurements made by commercial optical particle counters (OPCs). Additionally, the retrieved real part of the refractive index is generally found to be within the predicted error of 0.02 from the expected values for three species of humidified salt particles, with a refractive index that is well established. The airborne measurements used in this work were made aboard the NASA DC-8 aircraft during the Studies of Emissions and Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys (SEAC4RS) field campaign, and the inversion of this data represents the first aerosol retrievals of airborne polar nephelometer data. The results provide confidence in the real refractive index product, as well as in the retrieval's ability to accurately determine PSD, without assumptions about refractive index that are required by the majority of OPCs.

Espinosa, W. Reed↗

Imaging x-ray sources at a finite distance in coded-mask instruments

We present a method for the correction of beam divergence in finite distance sources imaging through coded-mask instruments. We discuss the defocusing artifacts induced by the finite distance showing two different approaches to remove such spurious effects. We applied our method to one-dimensional (1D) coded-mask systems, although it is also applicable in two-dimensional systems. We provide a detailed mathematical description of the adopted method and of the systematics introduced in the reconstructed image (e.g., the fraction of source flux collected in the reconstructed peak counts). The accuracy of this method was tested by simulating pointlike and extended sources at a finite distance with the instrumental setup of the SuperAGILE experiment, the 1D coded-mask x-ray imager onboard the AGILE (Astro-rivelatore Gamma a Immagini Leggero) mission. We obtained reconstructed images of good quality and high source location accuracy. Finally we show the results obtained by applying this method to real data collected during the calibration campaign of SuperAGILE. Our method was demonstrated to be a powerful tool to investigate the imaging response of the experiment, particularly the absorption due to the materials intercepting the line of sight of the instrument and the conversion between detector pixel and sky direction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗