Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Ionization Balance and Data Surveys

A review is given of the most commonly used databases for electron-impact ionization and recombination data. A brief description is given of the theoretical methods used to calculate ionization and recombination cross sections, and the role of metastable fractions in experimental measurements is discussed. Some of the remaining challenges are described for both ionization and recombination data and examples of the impact of new atomic data on fractional abundance calculations are given. The impact of new atomic data on generalized collisional-radiative coefficients is also discussed, and the importance of these density- and temperature-dependent coefficients on plasma modeling is shown.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exact results for ionization of model atomic systems

We review recent rigorous results concerning the ionization of model quantum systems by time-periodic external fields. The systems we consider consist of a single particle (electron) with a reference Hamiltonian H{sub 0}=-{delta}+V{sub 0}(x) (x is an element of R{sup d}) having both bound and continuum states. Starting from an initially localized state {psi}{sub 0}(x) is an element of L{sup 2}(R{sup d}), the system is subjected for t{>=}0 to an arbitrary strength time-periodic potential V{sub 1}(x,t)=V{sub 1}(x,t+2{pi}/{omega}). We prove that for a large class of V{sub 0}(x) and V{sub 1}(x,t), the wave function {psi}(x,t) will delocalize as t{yields}{infinity}, i.e., the system will ionize. The only exceptions are cases where there are time-periodic bound states of the Floquet operator associated with H{sub 0}+V{sub 1}. These do occur (albeit rarely) when V{sub 1} is not small. For spatially rapidly decaying V{sub 0} and V{sub 1}, {psi}(x,t) is generally given, for very long times, by a power series in t{sup -1/2} which we prove in some cases to be Borel summable. For the Coulomb potential V{sub 0}(x)=-b|x|{sup -1} in R{sup 3}, we prove ionization for V{sub 1}(x,t)=V{sub 1}(|x|)sin({omega}t-{theta}), V{sub 1}(|x|)=0 for |x|>R and V{sub 1}(x)>0 for |x|{<=}R. For this model, if {psi}{sub 0} is compactly supported both in x and in angular momentum, L, we obtain that {psi}(x,t){approx}O(t{sup -5/6}) as t{yields}{infinity}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optical phase and the ionization-dissociation dynamics of excited H{sub 2}

We investigate the influence of optical phase on the dynamics of hydrogen molecules excited to a spectral region with competition between predominantly rotational ionization, and dissociation. We show that an appropriate choice of optical phase changes the relative timing of the ionization and dissociation. Furthermore, the temporal width of the ionization and dissociation fluxes can also be controlled, in a matter-wave analogy of transform-limited optical pulses. The close link between the optical phase and the photoinduced electronic and molecular dynamics has important implications for femtochemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A requirement for diagnosis of the ionization state in opacity measurements

An accurate independent diagnosis of the temperature and the ionization state of the sample plasmas is important to get a set of well-characterized opacity data in experiment. An analysis of using x-ray scattering was presented for this purpose. Information of the ionization state of the sample plasmas could only be clearly detected when both the Compton and Rayleigh features of the scattering spectra are detectable in one laser shot. Only those plasmas with a few bounded electrons left can provide such kind of scattering spectra. The requirements for using the x-ray scattering as diagnosis are rigorous. Under a radiation field produced by laser-heated hohlraum, only limited number of sample elements can be heated to the ionization state required. Careful design is needed to achieve an x-ray scattering experiment. This work can be helpful to establish a diagnostic flattop for the opacity experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved hydrogen ionization rate in enhanced glow discharge plasma immersion ion implantation by enlarging the interaction path using an insulating tube

A small pointed hollow anode and large tabular cathode are used in enhanced glow discharge plasma immersion ion implantation (EGD-PIII). Electrons are repelled from the substrate by the electric field formed by the negative voltage pulses and concentrate in the vicinity of the anode to enhance the self-glow discharge process. To extend the application of EGD-PIII to plasma gases with low ionization rates, an insulating tube is used to increase the interaction path for electrons and neutrals in order to enhance the discharge near the anode. Results obtained from numerical simulation based on the particle-in-cell code, finite element method, and experiments show that this configuration enhances the ionization rate and subsequent ion implant fluence. The process is especially suitable for gases that have low ionization rates such as hydrogen and helium.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of high power impulse magnetron sputtering plasma ionization on the microstructure of TiN thin films

HIPIMS (High Power Impulse Magnetron Sputtering) discharge is a new PVD technology for the deposition of high-quality thin films. The deposition flux contains a high degree of metal ionization and nitrogen dissociation. The microstructure of HIPIMS-deposited nitride films is denser compared to conventional sputter technologies. However, the mechanisms acting on the microstructure, texture and properties have not been discussed in detail so far. In this study, the growth of TiN by HIPIMS of Ti in mixed Ar and N{sub 2} atmosphere has been investigated. Varying degrees of metal ionization and nitrogen dissociation were produced by increasing the peak discharge current (I{sub d}) from 5 to 30 A. The average power was maintained constant by adjusting the frequency. Mass spectrometry measurements of the deposition flux revealed a high content of ionized film-forming species, such as Ti{sup 1+}, Ti{sup 2+} and atomic nitrogen N{sup 1+}. Ti{sup 1+} ions with energies up to 50 eV were detected during the pulse with reducing energy in the pulse-off times. Langmuir probe measurements showed that the peak plasma density during the pulse was 3 x 10{sup 16} m{sup -3}. Plasma density, and ion flux ratios of N{sup 1+}: N{sub 2}{sup 1+} and Ti{sup 1+}: Ti{sup 0} increased linearly with peak current. The ratios exceeded 1 at 30 A. TiN films deposited by HIPIMS were analyzed by X-ray diffraction, and transmission electron microscopy. At high I{sub d}, N{sup 1+}: N{sub 2}{sup 1+} > 1 and Ti{sup 1+}: Ti{sup 0} > 1 were produced; a strong 002 texture was present and column boundaries in the films were atomically tight. As I{sub d} reduced and N{sup 1+}: N{sub 2}{sup 1+} and Ti{sup 1+}: Ti{sup 0} dropped below 1, the film texture switched to strong 111 with a dense structure. At very low I{sub d}, porosity between columns developed. The effects of the significant activation of the deposition flux observed in the HIPIMS discharge on the film texture, microstructure, morphology and properties are discussed.

36 MATERIALS SCIENCE↗

Solitary wave evolution in a magnetized inhomogeneous plasma under the effect of ionization

A modified form of Korteweg-deVries (KdV) equation appropriate to nonlinear ion acoustic solitary waves in an inhomogeneous plasma is derived in the presence of an external magnetic field and constant ionization in the plasma. This equation differs from usual version of the KdV equation because of the inclusion of two terms arising due to ionization and density gradient present in the plasma. In this plasma, only the compressive solitary waves are found to propagate corresponding to the fast and slow modes. The amplitude of the solitary wave increases with an enhancement in the ionization for the fast mode as well as for the slow mode. The effect of magnetic field is to enhance the width of the solitary structure. The amplitude is found to increase (decrease) with an enhancement in charge number of the ions for the fast (slow) mode. The tailing structure becomes more (less) prominent with the rise in ion drift velocity for the case of fast (slow) mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Equation of state of partially ionized argon plasma

The ionization degree, Hugoniots, and equation of state of partially ionized argon plasma were calculated by using self-consistent fluid variational theory for temperature of 6-50 kK and density of 0.05-4.0 g/cm{sup 3}. The corrections of lowering of ionization energy of fluid argon caused by the interactions among all particles of Ar, Ar{sup +}, Ar{sup 2+}, and e have been taken into consideration in terms of the correlation contributions to the chemical potential which is determined self-consistently by the free energy function. The initial density effects of gas argon under shock compression have been discussed. Comparison is performed with available shock-wave experiments and other theoretical calculations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear Fission Investigation with Twin Ionization Chamber

The purpose of the present paper was to report the recent results, obtained in development of digital pulse processing mathematics for prompt fission neutron (PFN) investigation using twin ionization chamber (TIC) along with fast neutron time-of-flight detector (ND). Due to well known ambiguities in literature (see refs. [4, 6, 9 and 11]), concerning a pulse induction on TIC electrodes by FF ionization, we first presented detailed mathematical analysis of fission fragment (FF) signal formation on TIC anode. The analysis was done using Ramo-Shockley theorem, which gives relation between charged particle motion between TIC electrodes and so called weighting potential. Weighting potential was calculated by direct numerical solution of Laplace equation (neglecting space charge) for the TIC geometry and ionization, caused by FF. Formulae for grid inefficiency (GI) correction and digital pulse processing algorithms for PFN time-of-flight measurements and pulse shape analysis are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of the Resonance Ionization Mass Spectrometer for Precise Identification of Failed Fuel in a Fast Reactor

Isotopic analysis of krypton (Kr) and xenon (Xe) by resonance ionization mass spectrometry (RIMS) is an effective tool for identification of failed fuel in fast reactors to achieve their safety operation and high plant availability. Reliability of the failed fuel detection and location (FFDL) system depends on the precise determination of {sup 78}Kr/{sup 80}Kr, {sup 82}Kr/{sup 80}Kr and {sup 126}Xe/{sup 129}Xe isotopic ratios, which is mainly hampered by statistical errors for detection of the corresponding isotopes except {sup 82}Kr generated in large amounts during operation of fast reactors. In this paper, we report on improvements of the laser optical system of our spectrometer to increase the resonance ionization efficiency of Kr and Xe atoms, focusing on (i) utilization of the uniform YAG laser beam to improve the wavelength conversion efficiency of sum frequency generation and (ii) reflection of the ultraviolet light by a concave mirror to increase the photon density. The results indicate that our upgraded resonance ionization mass spectrometer has enough performance for isotopic analysis of Kr and Xe required in the Monju FFDL system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of ionization distribution on plasma beam focusing characteristics in Hall thrusters

The relationship between ionization distribution and divergence of plasma beam in a Hall thruster is investigated using spectrum and probe methods. Experimental results indicate that the shift of ionization region towards the exit of channel causes the reduction of accelerating field and the enhancement of electron thermal pressure effect, which result in further deviation of equipotential lines to magnetic field lines and further increase in divergence of plasma beam. It is, therefore, suggested that to put the ionization region deep inside the channel and separate it from the acceleration region at the design, and development stage is helpful to improve the plasma beam focusing characteristics of a Hall thruster.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Isotope fractionation in surface ionization ion source of alkaline-earth iodides

The relationship between the isotope fractionation of alkaline-earth elements in the surface ionization ion source and the evaporation filament current, i.e., filament temperature, was studied. It was confirmed that the isotope fractionation depends on the evaporation filament temperature; the isotope fractionation in the case of higher temperature of filament becomes larger. The ionization and evaporation process in the surface ionization ion source was discussed, and it was concluded that the isotope fractionation is suppressed by setting at the lower temperature of evaporation filament because the dissociations are inhibited on the evaporation filament.

07 ISOTOPE AND RADIATION SOURCES↗

Highly ionized physical vapor deposition plasma source working at very low pressure

Highly ionized discharge for physical vapor deposition at very low pressure is presented in the paper. The discharge is generated by electron cyclotron wave resonance (ECWR) which assists with ignition of high power impulse magnetron sputtering (HiPIMS) discharge. The magnetron gun (with Ti target) was built into the single-turn coil RF electrode of the ECWR facility. ECWR assistance provides pre-ionization effect which allows significant reduction of pressure during HiPIMS operation down to p = 0.05 Pa; this is nearly more than an order of magnitude lower than at typical pressure ranges of HiPIMS discharges. We can confirm that nearly all sputtered particles are ionized (only Ti{sup +} and Ti{sup ++} peaks are observed in the mass scan spectra). This corresponds well with high plasma density n{sub e} {approx} 10{sup 18} m{sup -3}, measured during the HiPIMS pulse.

43 PARTICLE ACCELERATORS↗

Role of ionization and electron drift velocity profile to Rayleigh instability in a Hall thruster plasma

Role of ionization to Rayleigh instability is clarified in a Hall thruster plasma under the variety of profiles of electron drift velocity, namely, step-like profile (SLP) and two different super-Gaussian profiles (SGP1 and SGP2). For this, a relevant Rayleigh equation is derived and solved numerically using fourth-order Runge-Kutta method. Interestingly, an upper cutoff frequency of oscillations {omega}{sub max} is realized for the occurrence of the instability that shows dependence on the ionization rate {alpha}, electron drift velocity u{sub 0}, electron cyclotron frequency {Omega}, azimuthal wave number k{sub y}, plasma density n{sub 0}, density gradient {partial_derivative}n{sub 0}/{partial_derivative}x, ion (electron) thermal speed V{sub thI}(V{sub thE}), and ion (electron) plasma frequency {omega}{sub pi}({omega}{sub pe}). The frequency {omega}{sub max} follows the trend {omega}{sub max} (for SGP2) >{omega}{sub max} (for SLP) >{omega}{sub max} (for SGP1) and shows a similar behaviour with ionization for all types of the velocity profiles. The instability is found to grow faster for the higher {alpha} and the ion temperature but it acquires lower rate under the effect of the higher electron temperature; the perturbed potential also varies in accordance with the growth rate. The electron temperature influences the growth rate and cutoff frequency less significantly in comparison with the ion temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of magnetic field strength on potential well in the ionization stage of a double stage Hall thruster

Similar to a single stage Hall thruster, the magnetic field, which controls electron trajectory and electric field distribution, is the most important factor determining the performance of a double stage Hall thruster. Especially, a potential well, which is helpful to reduce the ion loss on the thruster walls, is shaped in the ionization stage due to the existence of an annular magnetic field topology there. In this paper, the influence of magnetic field strength in the ionization stage on the potential well is researched with both experiments and particle-in-cell simulations. It is found that the depth of potential well increases with the magnetic field strength as a result of enhanced magnetic confinement and lowered electron conductivity. Consequently, the plasma density as well as the ion current entering the acceleration stage increases. However, an excessive magnetic field strength leads to an excess of ion loss on the walls of the acceleration stage. Therefore, there is an appropriate magnetic field strength in the ionization stage that results in a proper potential well and consequently an optimal performance of a double stage Hall thruster.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preparation of the spacer for narrow electrode gap configuration in ionization-based gas sensor

Carbon nanotubes (CNTs) have started to be developed as the sensing element for ionization-based gas sensors due to the demand for improved sensitivity, selectivity, stability and other sensing properties beyond what can be offered by the conventional ones. Although these limitations have been overcome, the problems still remain with the conventional ionization-based gas sensors in that they are bulky and operating with large breakdown voltage and high temperature. Recent studies have shown that the breakdown voltage can be reduced by using nanostructured electrodes and narrow electrode gap. Nanostructured electrode in the form of aligned CNTs array with evenly distributed nanotips can enhance the linear electric field significantly. The later is attributed to the shorter conductivity path through narrow electrode gap. The paper presents the study on the design consideration in order to realize ionization based gas sensor using aligned carbon nanotubes array in an optimum sensor configuration with narrow electrode gap. Several deposition techniques were studied to deposit the spacer, the key component that can control the electrode gap. Plasma spray deposition, electron beam deposition and dry oxidation method were employed to obtain minimum film thickness around 32 {mu}m. For plasma spray method, sand blasting process is required in order to produce rough surface for strong bonding of the deposited film onto the surface. Film thickness, typically about 39 {mu}m can be obtained. For the electron beam deposition and dry oxidation, the film thickness is in the range of nanometers and thus unsuitable to produce the spacer. The deposited multilayer film consisting of copper, alumina and ferum on which CNTs array will be grown was found to be removed during the etching process. This is attributed to the high etching rate on the thin film which can be prevented by reducing the rate and having a thicker conductive copper film.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Near-coincident K-line and K-edge energies as ionization diagnostics for some high atomic number plasmas

For some high atomic number atoms, the energy of the K-edge is tens of eVs higher than the K-line energy of another atom, so that a few eV increase in the line's energy results in a decreasing transmission of the x-ray through a filter of the matching material. The transmission of cold iridium's Asymptotically-Equal-To 63.287 keV K{alpha}{sub 2} line through a lutetium filter is 7% lower when emitted by ionized iridium, consistent with an energy increase of {Delta}{epsilon} Asymptotically-Equal-To 10{+-}1 eV associated with the ionization. Likewise, the transmission of the K{beta}{sub 1} line of ytterbium through a near-coincident K-edge filter changes depending on plasma parameters that should affect the ionization. Systematic exploration of filter-line pairs like these could become a unique tool for diagnostics of suitable high energy density plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative study of ionization chamber detectors vis-a-vis a CCD detector for dispersive XAS measurement in transmission geometry

We have designed and fabricated parallel plate ionization chamber detectors and voltage vs. current characteristics (V-I curve) of the detectors were recorded with synchrotron radiation to qualify for use in X-ray Absorption Spectroscopy (XAS) measurements. After qualifying the ionization chambers, the detectors were used in the dispersive EXAFS beamline (BL-08) at INDUS-2 SRS in Turbo-XAS geometry. Using the same setup and under the same setting, XAS spectra were also recorded with a CCD detector and the observation on relative performance of the ionization chamber vis-a-vis the CCD detector is presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗