Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization potential”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Analysis of Inter-Moss Loops in the Solar Region with IRIS and SDO AIA: Automatic Event Detection and Characterization

The Interface Region Imaging Spectrograph (IRIS), launched in the summer of 2013, is designed specifically to observe and investigate the transition region and adjacent layers of the solar atmosphere, obtaining images in high spatial, temporal, and spectral resolution. Our particular work is focused on the evolution of inter-moss loops, which have been detected in the lower corona by the Atmospheric Imaging Assembly (AIA) and the High-Resolution Coronal Imager (Hi- C), but are known to have foot points below the transition region. With the high-resolution capabilities of IRIS and its Si IV pass band, which measures activity in the upper chromosphere, we can study these magnetic loops in detail and compare their characteristic length and time scales to those obtained from several AIA image sets, particularly the 171, 193, and 211 pass bands. By comparing the results between these four data sets, one can potentially establish a measure of the ionization equilibrium for the location in question. To explore this idea, we found a large, sit-and-stare observation within the IRIS database that fit our specifications. This data set contained a number of well-defined inter-moss loops (by visual inspection) with a cadence less than or equal to that of AIA (approximately 12 seconds). This particular data set was recorded on October 23, 2013 at 07:09:30, lasting for 3219 seconds with a field of view of 120.6 by 128.1 arcseconds, centered on -53.9 by 59.1 arcseconds from disk center. For ease of comparison, the AIA data has been interpolated to match the IRIS cadence and resolution. In the main portion of the poster, we demonstrate the detection of events, the information collected, and the immediate results to the right, showing the progress of an event with green as the start, blue as the peak, and red as the end. Below here, we demonstrate how pixels are combined to form groups. The 3D results are shown to the right

IRIS↗

Simulated Space Environment Effects on a Candidate Solar Sail Material

For long duration missions of solar sails, the sail material needs to survive harsh space environments and the degradation of the sail material controls operational lifetime. Therefore, understanding the effects of the space environment on the sail membrane is essential for mission success. In this study, we investigated the effect of simulated space environment effects of ionizing radiation, thermal aging and simulated potential damage on mechanical, thermal and optical properties of a commercial off the shelf (COTS) polyester solar sail membrane to assess the degradation mechanisms on a feasible solar sail. The solar sail membrane was exposed to high energy electrons (about 70 keV and 10 nA/cm2), and the physical properties were characterized. After about 8.3 Grad dose, the tensile modulus, tensile strength and failure strain of the sail membrane decreased by about 20 ~ 95%. The aluminum reflective layer was damaged and partially delaminated but it did not show any significant change in solar absorbance or thermal emittance. The effect on mechanical properties of a pre-cracked sample, simulating potential impact damage of the sail membrane, as well as thermal aging effects on metallized PEN (polyethylene naphthalate) film will be discussed.

Kang, Jin Ho↗

Effect of the annular region on the performance of a cylindrical Hall plasma thruster

Performance characteristics of a cylindrical Hall thruster depending on the depth of the annular region (L{sub a}) in front of the anode were investigated. The effect of the annular region was examined by operating thrusters corresponding to four different values of L{sub a} (0, 4, 6, and 10 mm) and a fixed length of the cylindrical region (25 mm). Various measurements such as electron and ion currents, thrust, anode efficiency, current and propellant utilizations, and ion energy distribution functions were performed. Such measurements lead to an interpretation that (1) a considerable potential difference may exist between the anode and the ionization region, which is presumably located near the end of the annular region where magnetic field lines converge; (2) this potential difference increases with respect to increasing L{sub a}; and (3) the presence of the annular region near the anode reduces the specific impulse and anode efficiency for the examined thrusters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solvent effects on differentiation of mouse brain tissue using laser microdissection ‘cut and drop’ sampling with direct mass spectral analysis

Rationale: Laser microdissection-liquid vortex capture/electrospray ionization mass spectrometry (LMD-LVC/ESI-MS) has potential for on-line classification of tissue but an investigation into what analytical conditions provide best spectral differentiation has not been conducted. The effects of solvent, ionization polarity, and spectral acquisition parameters on differentiation of mouse brain tissue regions are described.Methods: Individual 40 × 40 μm microdissections from cortex, white, grey, granular, and nucleus regions of mouse brain tissue were analyzed using different capture/ESI solvents, in positive and negative ion mode ESI, using time-of-flight (TOF)-MS and sequential window acquisitions of all theoretical spectra (SWATH)-MS (a permutation of tandem-MS), and combinations thereof. Principal component analysis-linear discriminant analysis (PCA-LDA), applied to each mass spectral dataset, was used to determine the accuracy of differentiation of mouse brain tissue regions. Results: Mass spectral differences associated with capture/ESI solvent composition manifested as altered relative distributions of ions rather than the presence or absence of unique ions. In negative ion mode ESI, 80/20 (v/v) methanol/water yielded spectra with low signal/noise ratios relative to other solvents. PCA-LDA models acquired using 90/10 (v/v) methanol/chloroform differentiated tissue regions with 100% accuracy while data collected using methanol misclassified some samples. The combination of SWATH-MS and TOF-MS data improved differentiation accuracy.Conclusions: Combined TOF-MS and SWATH-MS data differentiated white, grey, granular, and nucleus mouse tissue regions with greater accuracy than when solely using TOF-MS data. Using 90/10 (v/v) methanol/chloroform, tissue regions were perfectly differentiated. Lastly, these results will guide future studies looking to utilize the potential of LMD-LVC/ESI-MS for tissue and disease differentiation.

47 OTHER INSTRUMENTATION↗

Force generation due to three-dimensional plasma discharge on a conical forebody using pulsed direct current actuators

Understanding the behavior of three-dimensional plasmas around a pulsed dc actuator can be useful for its efficient operation in many applications. The effect of such actuators is studied using a self-consistent multibody system of neutral oxygen species and its plasma. The equations governing the motion of charged species are solved with the drift diffusion approximation. The electrostatic potential is computed from Poisson's equation. The electric field and ionization level are the highest close to the junction of electrodes and dielectric. The plasma body force thus generated also follows a similar characteristic. Results also show some dc corona instabilities. The temporal average of such force shows mostly acceleration from anode to cathode above the actuator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The influence of magnetic field strength in ionization stage on ion transport between two stages of a double stage Hall thruster

It is futile for a double stage Hall thruster to design a special ionization stage if the ionized ions cannot enter the acceleration stage. Based on this viewpoint, the ion transport under different magnetic field strengths in the ionization stage is investigated, and the physical mechanisms affecting the ion transport are analyzed in this paper. With a combined experimental and particle-in-cell simulation study, it is found that the ion transport between two stages is chiefly affected by the potential well, the potential barrier, and the potential drop at the bottom of potential well. With the increase of magnetic field strength in the ionization stage, there is larger plasma density caused by larger potential well. Furthermore, the potential barrier near the intermediate electrode declines first and then rises up while the potential drop at the bottom of potential well rises up first and then declines as the magnetic field strength increases in the ionization stage. Consequently, both the ion current entering the acceleration stage and the total ion current ejected from the thruster rise up first and then decline as the magnetic field strength increases in the ionization stage. Therefore, there is an optimal magnetic field strength in the ionization stage to guide the ion transport between two stages.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reduction of plasma electron density in a gas ionized by an electron beam - Use of a gaseous dielectric

Propagation of an electron beam through a gas creates a secondary electron/ion plasma which can have subsequent deleterious effects on the propagation of the beam. In the case of pulsed electron beams with short micropulse durations, these effects can be greatly reduced through the use of a small doping fraction of an electron attachment gas. We present a model which allows the calculation of the reduction in unbound plasma electron density attainable with a gaseous dielectric dopant. Potential problems with a dopant, including increased ionization, increased scattering, altered refractive index, and dopant saturation and fragmentation, are discussed.

Reid, Max B.↗

Energy distributions of sputtered copper neutrals and ions

Direct quantitative analysis of surfaces by secondary ion mass spectrometry will depend on an understanding of the yield ratio of ions to neutrals. This ratio as a function of the energy of the sputtered particles has been obtained for a clean polycrystalline copper surface sputtered by 1000-3000 eV Ar(+). The energy distributions of both neutral and ionized copper were measured with a retarding potential analyzer using potential modulation differentiation and signal averaging. The maximum for both distributions is identical and occurs near 2.5 eV. The energy distributions of neutrals is more sharply peaked than that of the ions, presumably as a consequence of more efficient nutralization of slow escaping ions by the mobile electrons of copper. The ion-neutral ratio is compared with results from various ionization models.

Lundquist, T. R.↗

Photoelectron angular distributions from polar molecules probed by intense femtosecond lasers

We present numerical calculations of molecular-frame photoelectron angular distributions in strong-field ionization of oriented polar HF and LiF molecules by linearly polarized laser pulses with durations of about 20 fs (seven cycles at 800 nm). The calculations are performed within the single-active-electron and frozen-nuclei approximations. Our analysis shows that for the HF and LiF molecules, anisotropies in the molecular potential and the probed orbital lead to enhanced ionization during laser half cycles with the field pointing antiparallel to the permanent dipole of the dipole term in a multipolar expansion of the anisotropic molecular potential. This is manifested as a strong asymmetry in the computed photoelectron angular distributions: The photoelectrons are preferentially detected opposite to the permanent dipole of the molecular potential. This phenomenon is very sensitive to the probed system (the probed orbital and the molecular potential) and the orientation angle between the molecular axis and the laser polarization.

74 ATOMIC AND MOLECULAR PHYSICS↗

Orientation-dependent enhanced ionization in acetylene revealed by ultrafast cross-polarized pulse pairs

We investigate the orientation dependence of enhanced ionization (EI) during strong-field-driven nuclear motion in acetylene (C 2 ⁢H 2 ). Here, we both initiate and probe molecular dynamics in acetylene with intense 6-fs cross-polarized pulse pairs, separated by a variable delay. Following multiple ionization by the first pulse, acetylene undergoes simultaneous elongation of the carbon-carbon and carbon-hydrogen bonds, enabling further ionization by the second pulse and the formation of a very highly charged state, [C 2 ⁢H 2 ] 6+ . At small interpulse delays (< 20 fs), this enhancement occurs when the molecule is aligned to the probe pulse. Conversely, at large delays (> 40 fs), formation of [C 2 ⁢H 2 ] 6+ occurs when the molecule is aligned to the pump pulse. By analyzing the polarization and time dependence of sequentially ionized [C 2 ⁢H 2 ] 6+ , we resolve two transient alignments that both contribute to a large increase in the multiple ionization yield. In conclusion, this cross-polarized pulse pair scheme uniquely enables selective probing of deeply bound orbitals, providing new insights on orientation-dependent EI in highly charged hydrocarbons.

Atomic & molecular clusters↗

Quantifying Uranium Isotope Ratios Using Resonance Ionization Mass Spectrometry: The Influence of Laser Parameters on Relative Ionization Probability

Resonance Ionization Mass Spectrometry (RIMS) has been developed as a method to measure relative uranium isotope abundances. In this approach, RIMS is used as an element-selective ionization process to provide a distinction between uranium atoms and potential isobars without the aid of chemical purification and separation. We explore the laser parameters critical to the ionization process and their effects on the measured isotope ratio. Specifically, the use of broad bandwidth lasers with automated feedback control of wavelength was applied to the measurement of 235 U/ 238 U ratios to decrease laser-induced isotopic fractionation. By broadening the bandwidth of the first laser in a 3-color, 3-photon ionization process from a bandwidth of 1.8 GHz to about 10 GHz, the variation in sequential relative isotope abundance measurements decreased from >10% to less than 0.5%. This procedure was demonstrated for the direct interrogation of uranium oxide targets with essentially no sample preparation. A rate equation model for predicting the relative ionization probability has been developed to study the effect of variation in laser parameters on the measured isotope ratio. This work demonstrates that RIMS can be used for the robust measurement of uranium isotope ratios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fragmentation dynamics of CS 2 dications and trications following S 2p ionization

Here, we present the results from a detailed study of the fragmentation dynamics of CS$_2^{2+}$ and CS$_2^{3+}$, formed in intense femtosecond soft x-ray pulses above the sulfur 2p edge, primarily through single core photoionization from the S 2p site, and subsequent Auger–Meitner decay(s). By combining three-dimensional velocity map imaging with covariance analysis, we determine the relative momenta of the ions produced in each two- and three-body fragmentation channel, at significantly higher ion count rates than conventional coincidence measurements. We shed new light on the wide range of fragmentation channels observed from the CS 2 dication and trication, including channels that involve ionization-induced bond formation and fragmentations producing undetected neutral cofragments. In the latter case, a “native frames” approach is used to isolate contributions from concerted and sequential fragmentations and extract dynamical information about each step of a concerted fragmentation process. While dications often fragment sequentially, the trication is dominated by concerted fragmentation. The main trication fragmentation channel into S + + C + + S + can be well-approximated by classical Coulombic simulations of the ground-state geometry distribution, reflecting both the nature of the trication potential energy surface and the rapid multiple ionization prior to substantial structural dynamics. This study demonstrates ways in which fundamental insights into the fragmentation dynamics of polycations following x-ray ionization may be extracted, which will be beneficial to future studies that employ time-resolved x-ray Coulomb explosion imaging to study ultrafast photochemistry.

Allum, Felix [Deutsches Elektronen-Synchrotron (DE↗

The Spacecraft Potential of Wind Over Time

In a space plasma, exposed to ionizing radiation, a conducting object like a spacecraft will generate a net charge as the relevant currents from the plasma and photoelectrons attempt to reach equilibrium over time. This net charging is measured (or inferred from particle measurements) as an electrostatic potential, called the spacecraft potential. The Wind spacecraft will be 30 years old on November 1, 2023 and as such, has one of the longest baselines of continuous spacecraft potential measurements of any space mission. We determine the spacecraft potential from observations of photoelectrons in the thermal particle data. We examine the variations over time finding oscillations that correlate with solar rotation. This preliminary study examines for other effects but is ultimately for the purpose of generating a properly calibrated velocity moment dataset for the entire Wind mission.

Lynn B. Wilson III↗

Green’s function coupled cluster simulation of the near-valence ionizations of DNA-fragments

Accurate description of the ionization process in DNA is crucial to the understanding of the DNA damage under exposure to ionizing radiation and the exploration of the potential application of DNA strands in nanoelectronics. In this work, by employing our recently developed Green’s function coupled-cluster library on supercomputing facilities, we have studied the spectral functions of several guanine–cytosine (G–C) base pair structures ([G–C]n, n = 1–3) for the first time in a relatively broad near-valence regime ([−25.0, −5.0] eV) in the coupled-cluster with singles and doubles level. Our focus is to give a preliminary many-body coupled-cluster understanding and guideline of the vertical ionization energy (VIE), spectral profile, and ionization feature changes of these systems as the system size expands in this near-valence regime. The results show that, as the system size expands, even though the lowest VIEs keep decreasing, the changes of spectral function profile and the relative peak positions get unexpectedly smaller. Further analysis of the ionized states associated with the most intensive peak in the spectral functions reveals non-negligible |2h, 1p⟩’s in the ionized wave functions of the considered G–C base pair systems. The leading |2h, 1p⟩’s associated with the main ionizations from the cytosine part of the G–C base pairs feature a transition from the intra-base-pair cytosine π → π* excitation to the inter-base-pair electron excitation as the size of G–C base pairs expands, which also indicates the minimum quantum region in the many-body calculations of DNA systems.

Peng, Bo (ORCID:0000000242267294)↗

Use of a microscope stage-mounted Nickel-63 microirradiator for real-time observation of the DNA double-strand break response

Eukaryotic cells begin to assemble discrete, nucleoplasmic repair foci within seconds after the onset of exposure to ionizing radiation. Real-time imaging of this assembly has the potential to further our understanding of the effects of medical and environmental radiation exposure. Here, we describe a micro-irradiation system for targeted delivery of ionizing radiation to individual cells without the need for specialized facilities. The system consists of a 25-micron diameter electroplated Nickel-63 electrode, enveloped in a glass capillary and mounted in a micromanipulator. Because of the low energy of the beta radiation and the minute total amount of isotope present on the tip, the device can be safely handled with minimum precautions. We demonstrate the use of this system for tracking assembly of individual repair foci in real time in live U2OS human osteosarcoma cells. Results indicate that there is a subset of foci that appear and disappear rapidly, before a plateau level is reached 30 min post-exposure. This subset of foci would not have been evident without real-time observation. The development of a micro-irradiation system that is compatible with a standard biomedical laboratory expands the potential for real-time investigation of the biological effects of ionizing radiation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-Pressure, Field-Ionizing Mass Spectrometer

A small mass spectrometer utilizing a miniature field ionization source is now undergoing development. It is designed for use in a variety of applications in which there are requirements for a lightweight, low-power-consumption instrument that can analyze the masses of a wide variety of molecules and ions. The device can operate without need for a high-vacuum, carrier-gas feed radioactive ionizing source, or thermal ionizer. This mass spectrometer can operate either in the natural vacuum of outer space or on Earth at any ambient pressure below 50 torr (below about 6.7 kPa) - a partial vacuum that can easily be reached by use of a small sampling pump. This mass spectrometer also has a large dynamic range - from singly charged small gas ions to deoxyribonucleic acid (DNA) fragments larger than 104 atomic mass units - with sensitivity adequate for detecting some molecules and ions at relative abundances of less than one part per billion. This instrument (see figure) includes a field ionizer integrated with a rotating-field mass spectrometer (RFMS). The field ionizer effects ionization of a type characterized as "soft" in the art because it does not fragment molecules or initiate avalanche arcing. What makes the "soft" ionization mode possible is that the distance between the ionizing electrodes is less than mean free path for ions at the maximum anticipated operating pressure, so that the ionizer always operates on the non-breakdown side of the applicable Paschen curve (a standard plot of breakdown potential on the ordinate and pressure electrode separation on the abscissa). The field ionizer in this instrument is fabricated by micromachining a submicron-thick membrane out of an electrically nonconductive substrate, coating the membrane on both sides to form electrodes, then micromachining small holes through the electrodes and membrane. Because of the submicron electrode separation, even a potential of only 1 V applied between the electrodes gives rise to an electric field with a strength of in excess of a megavolt per meter strong enough to ionize any gas molecules passing through the holes. An accelerator grid and an electrostatic deflector focus the ions from the field ionizer into the rotating-field cell of the RFMS. The potentials applied to the electrodes of the cell to generate the rotating electric field typically range from 1 to 13 V. The ions travel in well-defined helices within this cell, after which they are collected in a Faraday cup. The mass of most of the molecules reaching the Faraday cup decreases with increasing frequency of rotation of the electric field in the cell. Therefore, the frequency of rotation of the electric field is made to vary in order to scan through a desired range of ion masses: For example, lightweight gas molecules are scanned at frequencies in the megahertz range, while DNA and other large organic molecules are scanned at kilohertz frequencies.

Hartley, Frank↗

Novel two-step laser ablation and ionization mass spectrometry (2S-LAIMS) of actor-spectator ice layers: Probing chemical composition of D{sub 2}O ice beneath a H{sub 2}O ice layer

In this work, we report for the first time successful analysis of organic aromatic analytes imbedded in D{sub 2}O ices by novel infrared (IR) laser ablation of a layered non-absorbing D{sub 2}O ice (spectator) containing the analytes and an ablation-active IR-absorbing H{sub 2}O ice layer (actor) without the analyte. With these studies we have opened up a new method for the in situ analysis of solids containing analytes when covered with an IR laser-absorbing layer that can be resonantly ablated. This soft ejection method takes advantage of the tenability of two-step infrared laser ablation and ultraviolet laser ionization mass spectrometry, previously demonstrated in this lab to study chemical reactions of polycyclic aromatic hydrocarbons (PAHs) in cryogenic ices. The IR laser pulse tuned to resonantly excite only the upper H{sub 2}O ice layer (actor) generates a shockwave upon impact. This shockwave penetrates the lower analyte-containing D{sub 2}O ice layer (spectator, a non-absorbing ice that cannot be ablated directly with the wavelength of the IR laser employed) and is reflected back, ejecting the contents of the D{sub 2}O layer into the vacuum where they are intersected by a UV laser for ionization and detection by a time-of-flight mass spectrometer. Thus, energy is transmitted from the laser-absorbing actor layer into the non-absorbing spectator layer resulting its ablation. We found that isotope cross-contamination between layers was negligible. We also did not see any evidence for thermal or collisional chemistry of PAH molecules with H{sub 2}O molecules in the shockwave. We call this “shockwave mediated surface resonance enhanced subsurface ablation” technique as “two-step laser ablation and ionization mass spectrometry of actor-spectator ice layers.” This method has its roots in the well-established MALDI (matrix assisted laser desorption and ionization) method. Our method offers more flexibility to optimize both the processes—ablation and ionization. This new technique can thus be potentially employed to undertake in situ analysis of materials imbedded in diverse media, such as cryogenic ices, biological samples, tissues, minerals, etc., by covered with an IR-absorbing laser ablation medium and study the chemical composition and reaction pathways of the analyte in its natural surroundings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of the Chodura sheath on tungsten ionization and emission in tokamak divertors

The decay of the electric potential in the sheath region in tokamak divertors occurs on a scale length on the order of the main ion gyroradius (Chodura sheath) due to magnetic fields lines intersecting the divertor plates at grazing incidence. As a consequence, high-Z impurities like tungsten ionize within the sheath region in attached plasma conditions. The modification of the electron distribution in the sheath region must thus be taken into account to accurately model ionization and emission of impurities within the sheath region. To that end, an analytical expression of the distribution of the vertical ionization path for impurities sputtered from divertor plasma-facing components is derived. This expression is then used to estimate the fraction of neutral impurities ionizing within the sheath and the average vertical ionization path, and to derive an effective SXB (the number of ionizations per emitted photon) coefficient which includes the effects of the variation of the electron distribution in the sheath region. These results are applied to tungsten impurities sputtered from divertor plates. It is shown that the SXB coefficient for neutral tungsten is significantly reduced in high-density attached divertor plasma conditions (n e ≳ 5 × 10 13 cm -3 ) because of the ionization of neutral tungsten well within the sheath region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗