Search NASA⌕ Search

SEARCH · Search NASA

Results for “iterative method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Implications of CT noise and artifacts for quantitative {sup 99m}Tc SPECT/CT imaging

Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI{sub vol} = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in {sup 99m}Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI{sub vol} = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ{sub 140} {sub keV} on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed {sup 99m}Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect SPECT quantification is low (CTDI{sub vol} ∼ 4 μGy), the low dose limit for the CT exam as part of SPECT/CT will be guided by CT image quality requirements for anatomical localization and artifact reduction. A CT technique with higher kVp in combination with lower mAs is recommended when low-dose CT images are used for AC to minimize beam-hardening artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the Reversibility of Newton-Raphson Root-Finding Method

Reversibility of a computational method is the ability to execute the method forward as well as backward. Reversible computational methods are generally useful in undoing incorrect computation in a speculative execution setting designed for efficient parallel processing. Here, reversibility is explored of a common component in scientific codes, namely, the Newton-Raphson root-finding method. A reverse method is proposed that is aimed at retracing the sequence of points that are visited by the forward method during forward iterations. When given the root, along with the number of iterations, of the forward method, this reverse method is aimed at backtracking along the reverse sequence of points to finally recover the original starting point of the forward method. The operation of this reverse method is illustrated on a few example functions, serving to highlight the method's strengths and shortcomings.

97 MATHEMATICS AND COMPUTING↗

The preprocessed doacross loop

Dependencies between loop iterations cannot always be characterized during program compilation. Doacross loops typically make use of a-priori knowledge of inter-iteration dependencies to carry out required synchronizations. A type of doacross loop is proposed that allows the scheduling of iterations of a loop among processors without advance knowledge of inter-iteration dependencies. The method proposed for loop iterations requires that parallelizable preprocessing and postprocessing steps be carried out during program execution.

Saltz, Joel H.↗

Helicopter trim analysis by shooting and finite element methods with optimally damped Newton iterations

Helicopter trim settings of periodic initial state and control inputs are investigated for convergence of Newton iteration in computing the settings sequentially and in parallel. The trim analysis uses a shooting method and a weak version of two temporal finite element methods with displacement formulation and with mixed formulation of displacements and momenta. These three methods broadly represent two main approaches of trim analysis: adaptation of initial-value and finite element boundary-value codes to periodic boundary conditions, particularly for unstable and marginally stable systems. In each method, both the sequential and in-parallel schemes are used, and the resulting nonlinear algebraic equations are solved by damped Newton iteration with an optimally selected damping parameter. The impact of damped Newton iteration, including earlier-observed divergence problems in trim analysis, is demonstrated by the maximum condition number of the Jacobian matrices of the iterative scheme and by virtual elimination of divergence. The advantages of the in-parallel scheme over the conventional sequential scheme are also demonstrated.

Achar, N. S.↗

CMFD and coarse-mesh DSA

The Coarse Mesh Finite Difference (CMFD) and Diffusion Synthetic Acceleration (DSA) methods are two widely-used, independently-developed acceleration methods for iteratively solving deterministic particle transport simulations. In this paper we show that these methods are related in the following way: if the standard notion of DSA as a 'fine mesh' method is generalized to that of a coarse mesh method, then the linearized form of CMFD is algebraically equivalent to a coarse mesh form of DSA. Also, we demonstrate theoretically (via Fourier analysis) and computationally that CMFD and coarse mesh DSA have nearly the same convergence properties. (authors)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Control Effector Unsaturation Modification to the Cascading Generalized Inverse Control Allocation Algorithm

Control allocation has sufficiently progressed such that it is used in front-line fighter aircraft such as the F-18Superhornet and the F-35 Joint Strike Fighter. Published literature shows the F-35 utilizes Nonlinear Dynamic Inversion in conjunction with an Effector Blender that incorporates the Cascading Generalized Inverse control allocation algorithm. While the Cascading Generalized Inverse algorithm is one of the premier generalized inverse methods, it does suffer from three deficiencies. In particular, it suffers from an inability to achieve some desired outcomes, it intermittently provides non-optimal solutions and generally fails to preserve moment direction near maximal achievable moments. An effector unsaturation method based on a Scalar Difference Quadratic was first introduced and implemented on the iterative Prediction Method control allocation algorithm which was shown to consistently achieve optimal (weighted) control allocation solutions throughout the entire Attainable Moment Set while preserving desired moment direction. In this paper, the shortcomings of the Cascading Generalized Inverse algorithm are addressed by augmenting the baseline algorithm with Scalar Difference Quadratic unsaturation identification and location at each iteration. Numerical case studies demonstrate that the Modified Cascading Generalized Inverse algorithm resolves the aforementioned deficiencies.

Michael J Acheson↗

Clinical application and validation of an iterative forward projection matching algorithm for permanent brachytherapy seed localization from conebeam-CT x-ray projections

Purpose: To experimentally validate a new algorithm for reconstructing the 3D positions of implanted brachytherapy seeds from postoperatively acquired 2D conebeam-CT (CBCT) projection images. Methods: The iterative forward projection matching (IFPM) algorithm finds the 3D seed geometry that minimizes the sum of the squared intensity differences between computed projections of an initial estimate of the seed configuration and radiographic projections of the implant. In-house machined phantoms, containing arrays of 12 and 72 seeds, respectively, are used to validate this method. Also, four {sup 103}Pd postimplant patients are scanned using an ACUITY digital simulator. Three to ten x-ray images are selected from the CBCT projection set and processed to create binary seed-only images. To quantify IFPM accuracy, the reconstructed seed positions are forward projected and overlaid on the measured seed images to find the nearest-neighbor distance between measured and computed seed positions for each image pair. Also, the estimated 3D seed coordinates are compared to known seed positions in the phantom and clinically obtained VariSeed planning coordinates for the patient data. Results: For the phantom study, seed localization error is (0.58{+-}0.33) mm. For all four patient cases, the mean registration error is better than 1 mm while compared against the measured seed projections. IFPM converges in 20-28 iterations, with a computation time of about 1.9-2.8 min/iteration on a 1 GHz processor. Conclusions: The IFPM algorithm avoids the need to match corresponding seeds in each projection as required by standard back-projection methods. The authors' results demonstrate {approx}1 mm accuracy in reconstructing the 3D positions of brachytherapy seeds from the measured 2D projections. This algorithm also successfully localizes overlapping clustered and highly migrated seeds in the implant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiscale modeling of the influence of Fe content in a Al-Si-Cu alloy on the size distribution of intermetallic phases and micropores

A multiscale model was developed to simulate the formation of Fe-rich intermetallics and pores in quaternary Al-Si-Cu-Fe alloys. At the microscale, the multicomponent diffusion equations were solved for multiphase (liquid-solid-gas) materials via a finite difference framework to predict microstructure formation. A fast and robust decentered plate algorithm was developed to simulate the strong anisotropy of the solid/liquid interfacial energy for the Fe-rich intermetallic phase. The growth of porosity was controlled by local pressure drop due to solidification and interactions with surrounding solid phases, in addition to hydrogen diffusion. The microscale model was implemented as a subroutine in a commercial finite element package, producing a coupled multiscale model. This allows the influence of varying casting conditions on the Fe-rich intermetallics, the pores, and their interactions to be predicted. Synchrotron x-ray tomography experiments were performed to validate the model by comparing the three-dimensional morphology and size distribution of Fe-rich intermetallics as a function of Fe content. Large platelike Fe-rich {beta} intermetallics were successfully simulated by the multiscale model and their influence on pore size distribution in shape castings was predicted as a function of casting conditions.

36 MATERIALS SCIENCE↗

Active space selection with self-healing diffusion Monte Carlo algorithms for periodic solids

Multideterminant Diffusion Monte Carlo (DMC) displays improved accuracy over single determinant DMC. Self-Healing Diffusion Monte Carlo (SHDMC) is a DMC based method that iteratively improves a multideterminant trial wavefunction. Although configuration interaction or complete active space (CAS) methods are very accurate and computationally feasible for many systems, they are not optimal for application to solids. SHDMC is accurate and designed for application to solids, so developing SHDMC based active space selection algorithms is a worthy endeavor. Here, we present and compare active space selection algorithms that are designed for use in conjunction with SHDMC, without relying on external approaches. For benchmarking, we calculated the ground state energy of a small unit cell of graphene and compared the results with a complete basis set extrapolated selected CI and a reference SHDMC trajectory. We found that systematically expanding the active space using an “auto-branching” algorithm optimally balances accuracy with computational practicality. To the best of our knowledge, this is the first work that demonstrates completely self-contained DMC-based active space selection algorithms that do not depend on external methods for determinant selection.

Spanedda, Nicole [ORNL]↗

Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT

Purpose: Image reconstruction and motion model estimation in four-dimensional cone-beam CT (4D-CBCT) are conventionally handled as two sequential steps. Due to the limited number of projections at each phase, the image quality of 4D-CBCT is degraded by view aliasing artifacts, and the accuracy of subsequent motion modeling is decreased by the inferior 4D-CBCT. The objective of this work is to enhance both the image quality of 4D-CBCT and the accuracy of motion model estimation with a novel strategy enabling simultaneous motion estimation and image reconstruction (SMEIR).Methods: The proposed SMEIR algorithm consists of two alternating steps: (1) model-based iterative image reconstruction to obtain a motion-compensated primary CBCT (m-pCBCT) and (2) motion model estimation to obtain an optimal set of deformation vector fields (DVFs) between the m-pCBCT and other 4D-CBCT phases. The motion-compensated image reconstruction is based on the simultaneous algebraic reconstruction technique (SART) coupled with total variation minimization. During the forward- and backprojection of SART, measured projections from an entire set of 4D-CBCT are used for reconstruction of the m-pCBCT by utilizing the updated DVF. The DVF is estimated by matching the forward projection of the deformed m-pCBCT and measured projections of other phases of 4D-CBCT. The performance of the SMEIR algorithm is quantitatively evaluated on a 4D NCAT phantom. The quality of reconstructed 4D images and the accuracy of tumor motion trajectory are assessed by comparing with those resulting from conventional sequential 4D-CBCT reconstructions (FDK and total variation minimization) and motion estimation (demons algorithm). The performance of the SMEIR algorithm is further evaluated by reconstructing a lung cancer patient 4D-CBCT.Results: Image quality of 4D-CBCT is greatly improved by the SMEIR algorithm in both phantom and patient studies. When all projections are used to reconstruct a 3D-CBCT by FDK, motion-blurring artifacts are present, leading to a 24.4% relative reconstruction error in the NACT phantom. View aliasing artifacts are present in 4D-CBCT reconstructed by FDK from 20 projections, with a relative error of 32.1%. When total variation minimization is used to reconstruct 4D-CBCT, the relative error is 18.9%. Image quality of 4D-CBCT is substantially improved by using the SMEIR algorithm and relative error is reduced to 7.6%. The maximum error (MaxE) of tumor motion determined from the DVF obtained by demons registration on a FDK-reconstructed 4D-CBCT is 3.0, 2.3, and 7.1 mm along left–right (L-R), anterior–posterior (A-P), and superior–inferior (S-I) directions, respectively. From the DVF obtained by demons registration on 4D-CBCT reconstructed by total variation minimization, the MaxE of tumor motion is reduced to 1.5, 0.5, and 5.5 mm along L-R, A-P, and S-I directions. From the DVF estimated by SMEIR algorithm, the MaxE of tumor motion is further reduced to 0.8, 0.4, and 1.5 mm along L-R, A-P, and S-I directions, respectively.Conclusions: The proposed SMEIR algorithm is able to estimate a motion model and reconstruct motion-compensated 4D-CBCT. The SMEIR algorithm improves image reconstruction accuracy of 4D-CBCT and tumor motion trajectory estimation accuracy as compared to conventional sequential 4D-CBCT reconstruction and motion estimation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerating and stabilizing the convergence of vibrational self-consistent field calculations via the direct inversion of the iterative subspace (vDIIS) algorithm

The vibrational self-consistent field (VSCF) method yields anharmonic states and spectra for molecular vibrations, and it serves as the starting point for more sophisticated correlated-vibration methods. Convergence of the iterative, non-linear optimization in VSCF calculations can be erratic or altogether unsuccessful, particularly for chemical systems involving low-frequency motions. In this work, a vibrational formulation of the Direct Inversion of the Iterative Subspace method of Pulay is presented and investigated. This formulation accounts for distinct attributes of the vibrational and electronic cases, including the expansion of each single-mode vibrational wavefunction in its own basis set. The resulting Direct Inversion of the Iterative Subspace method is shown to substantially accelerate VSCF convergence in all convergent cases as well as rectify many cases where Roothaan-based methods fail. Performance across systems ranging from small, rigid molecules to weakly bound molecular clusters is investigated in this analysis.

Chemistry↗

PARETO: A novel evolutionary optimization approach to multiobjective IMRT planning

Purpose: In radiation therapy treatment planning, the clinical objectives of uniform high dose to the planning target volume (PTV) and low dose to the organs-at-risk (OARs) are invariably in conflict, often requiring compromises to be made between them when selecting the best treatment plan for a particular patient. In this work, the authors introduce Pareto-Aware Radiotherapy Evolutionary Treatment Optimization (pareto), a multiobjective optimization tool to solve for beam angles and fluence patterns in intensity-modulated radiation therapy (IMRT) treatment planning. Methods: pareto is built around a powerful multiobjective genetic algorithm (GA), which allows us to treat the problem of IMRT treatment plan optimization as a combined monolithic problem, where all beam fluence and angle parameters are treated equally during the optimization. We have employed a simple parameterized beam fluence representation with a realistic dose calculation approach, incorporating patient scatter effects, to demonstrate feasibility of the proposed approach on two phantoms. The first phantom is a simple cylindrical phantom containing a target surrounded by three OARs, while the second phantom is more complex and represents a paraspinal patient. Results: pareto results in a large database of Pareto nondominated solutions that represent the necessary trade-offs between objectives. The solution quality was examined for several PTV and OAR fitness functions. The combination of a conformity-based PTV fitness function and a dose-volume histogram (DVH) or equivalent uniform dose (EUD) -based fitness function for the OAR produced relatively uniform and conformal PTV doses, with well-spaced beams. A penalty function added to the fitness functions eliminates hotspots. Comparison of resulting DVHs to those from treatment plans developed with a single-objective fluence optimizer (from a commercial treatment planning system) showed good correlation. Results also indicated that pareto shows promise in optimizing the number of beams. Conclusions: This initial evaluation of the evolutionary optimization software tool pareto for IMRT treatment planning demonstrates feasibility and provides motivation for continued development. Advantages of this approach over current commercial methods for treatment planning are many, including: (1) fully automated optimization that avoids human controlled iterative optimization and potentially improves overall process efficiency, (2) formulation of the problem as a true multiobjective one, which provides an optimized set of Pareto nondominated solutions refined over hundreds of generations and compiled from thousands of parameter sets explored during the run, and (3) rapid exploration of the final nondominated set accomplished by a graphical interface used to select the best treatment option for the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of the rectilinear impact pseudostate method to modeling of third-body effects on interplanetary trajectories

Interplanetary transfer trajectories, subject to the third-body gravitational attraction of the departure and arrival planets, noticeably deviate from the conic Lambert theorem solutions. The pseudostate method represents a useful improvement over conic theory by allowing the spacecraft motion about the sun and each terminal body to be superimposed, provided certain rules are followed. The new variant of the method requires iteration on time along the two planetocentric rectilinear impact trajectories. The operational equivalence of the method to the point-to-point Lambert formulation is an attractive feature, already used to advantage in the generation of mission design data

Sergeyevsky, A. B.↗

Schroedinger's radial equation - Solution by extrapolation

A high-accuracy numerical method for the solution of a 1D Schroedinger equation that is suitable for a diatomic molecule, obtained by combining a finite-difference method with iterative extrapolation to the limit, is presently shown to have several advantages over more conventional methods. Initial guesses for the term values are obviated, and implementation of the algorithm is straightforward. The method is both less sensitive to round-off error, and faster than conventional methods for equivalent accuracy. These advantages are illustrated through the solution of Schroedinger's equation for a Morse potential function suited for HCl and a numerically derived Rydberg-Klein-Rees potential function for the X 1Sigma(+) state of CO.

Goorvitch, D.↗

Mixed-Precision Spectral Deferred Correction: Preprint

Convergence of spectral deferred correction (SDC), where low-order time integration methods are used to construct higher-order methods through iterative refinement, can be accelerated in terms of computational effort by using mixed-precision methods. Using ideas from multi-level SDC (in turn based on FAS multigrid ideas), some of the SDC correction sweeps can use function values computed in reduced precision without adversely impacting the accuracy of the final solution. This is particularly beneficial for the performance of combustion solvers such as S3D [6] which require double precision accuracy but are performance limited by the cost of data motion.

97 MATHEMATICS AND COMPUTING↗

DAKOTA Design Analysis Kit for Optimization and Terascale

The DAKOTA (Design Analysis Kit for Optimization and Terascale Applications) toolkit provides a flexible and extensible interface between simulation codes (computational models) and iterative analysis methods. By employing object-oriented design to implement abstractions of the key components required for iterative systems analyses, the DAKOTA toolkit provides a flexible and extensible problem-solving environment for design and analysis of computational models on high performance computers.A user provides a set of DAKOTA commands in an input file and launches DAKOTA. DAKOTA invokes instances of the computational models, collects their results, and performs systems analyses. DAKOTA contains algorithms for optimization with gradient and nongradient-based methods; uncertainty quantification with sampling, reliability, polynomial chaos, stochastic collocation, and epistemic methods; parameter estimation with nonlinear least squares methods; and sensitivity/variance analysis with design of experiments and parameter study methods. These capabilities may be used on their own or as components within advanced strategies such as hybrid optimization, surrogate-based optimization, mixed integer nonlinear programming, or optimization under uncertainty. Services for parallel computing, simulation interfacing, approximation modeling, fault tolerance, restart, and graphics are also included.

SciDAC↗

Advanced method for high-throughput expression of mutated eukaryotic membrane proteins in Saccharomyces cerevisiae

Crystallization of eukaryotic membrane proteins is a challenging, iterative process. The protein of interest is often modified in an attempt to improve crystallization and diffraction results. To accelerate this process, we took advantage of a GFP-fusion yeast expression system that uses PCR to direct homologous recombination and gene cloning. We explored the possibility of employing more than one PCR fragment to introduce various mutations in a single step, and found that when up to five PCR fragments were co-transformed into yeast, the recombination frequency was maintained as the number of fragments was increased. All transformants expressed the model membrane protein, while the resulting plasmid from each clone contained the designed mutations only. Thus, we have demonstrated a technique allowing the expression of mutant membrane proteins within 5 days, combining a GFP-fusion expression system and yeast homologous recombination.

60 APPLIED LIFE SCIENCES↗