Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

SU-E-T-223: Investigation of the Accuracy of Two-Dimensional Dose Distributions Measurement From High-Dose-Rate Brachytherapy Ir-192 Source Using Multiple-Diode-Array Detector (MapCheck2)

Purpose: To investigate the dosimetric accuracy of multiple-diode-array detector (Mapcheck2) for high-dose-rate brachytherapy Ir-192 source. The two-dimensional (2D) dose distributions measured with MapCheck2 were validated with EBT2 Gafchromic film measurement and AAPM task-group- 43 (TG-43) modeling. Methods: 2D-dose distributions from Ir-192 source were measured with MapCheck2 and EBT2-films. MapCheck2 response was corrected for effects: directional dependence, diode and phantom heterogeneity. Optical density growth of the film was controlled by synchronized scanning of the film exposed to Ir-192 and calibration films exposed to 6 MV linac beams. Similarly, MapCheck2 response was calibrated to dose using 6 MV beams. An empirical model was developed for the dose distributions measured with Mapcheck2 that considered directional, diode and phantom heterogeneity corrections. The dose deposited in solid-state-detectors was modeled using a cavity theory model for the diode. This model was then validated with measurements using EBT2-films and calculations with TG-43. Results: The response of MapCheck2 has been corrected for different effects including: (a) directional dependence of 0–20% over angular range 0o–90o, (b) phantom heterogeneity (3%) and (c) diode heterogeneity (9%). The corrected dose distributions measured with MapCheck2 agreed well with the measured dose distributions from EBT2-film and with calculations using TG-43 within 5% over a wide range of dose levels and rates. The advantages of MapCheck2 include less noisy, linear and stable response compared with film. The response of MapCheck2 exposed to 192Ir-source showed no energy dependence similar to its response to MV energy beam. Detection spatial-resolution of individual diodes was 0.8×0.8 mm2, however, 2DMapCheck2 resolution is limited by distance between diodes (7.07 mm). Conclusion: The dose distribution measured with MapCheck2 agreed well within 5% with that measured using EBT2-films; and calculations with TG- 43. Considering correction of artifacts, MapCheck2 provides a compact, practical and accurate dosimetric tool for measurement of 2D-dose distributions for brachytherapy Ir-192.

60 APPLIED LIFE SCIENCES↗

Parallel beamlet dose calculation via beamlet contexts in a distributed multi‐GPU framework

Purpose Dose calculation is one of the most computationally intensive, yet essential tasks in the treatment planning process. With the recent interest in automatic beam orientation and arc trajectory optimization techniques, there is a great need for more efficient model‐based dose calculation algorithms that can accommodate hundreds to thousands of beam candidates at once. Foundational work has shown the translation of dose calculation algorithms to graphical processing units ( GPU s), lending to remarkable gains in processing efficiency. But these methods provide parallelization of dose for only a single beamlet, serializing the calculation of multiple beamlets and under‐utilizing the potential of modern GPU s. In this paper, the authors propose a framework enabling parallel computation of many beamlet doses using a novel beamlet context transformation and further embed this approach in a scalable network of multi‐ GPU computational nodes. Methods The proposed context‐based transformation separates beamlet‐local density and TERMA into distinct beamlet contexts that independently provide sufficient data for beamlet dose calculation. Beamlet contexts are arranged in a composite context array with dosimetric isolation, and the context array is subjected to a GPU collapsed‐cone convolution superposition procedure, producing the set of beamlet‐specific dose distributions in a single pass. Dose from each context is converted to a sparse representation for efficient storage and retrieval during treatment plan optimization. The context radius is a new parameter permitting flexibility between the speed and fidelity of the dose calculation process. A distributed manager‐worker architecture is constructed around the context‐based GPU dose calculation approach supporting an arbitrary number of worker nodes and resident GPU s. Phantom experiments were executed to verify the accuracy of the context‐based approach compared to Monte Carlo and a reference CPU ‐ CCCS implementation for single beamlets and broad beams composed by addition of beamlets. Dose for representative 4 π beam sets was calculated in lung and prostate cases to compare its efficiency with that of an existing beamlet‐sequential GPU ‐ CCCS implementation. Code profiling was also performed to evaluate the scalability of the framework across many networked GPU s. Results The dosimetric accuracy of the context‐based method displays <1.35% and 2.35% average error from the existing serialized CPU ‐ CCCS algorithm and Monte Carlo simulation for beamlet‐specific PDD s in water and slab phantoms, respectively. The context‐based method demonstrates substantial speedup of up to two orders of magnitude over the beamlet‐sequential GPU ‐ CCCS method in the tested configurations. The context‐based framework demonstrates near linear scaling in the number of distributed compute nodes and GPU s employed, indicating that it is flexible enough to meet the performance requirements of most users by simply increasing the hardware utilization. Conclusions The context‐based approach demonstrates a new expectation of performance for beamlet‐based dose calculation methods. This approach has been successful in accelerating the dose calculation process for very large‐scale treatment planning problems ‐ such as automatic 4 π IMRT beam orientation and VMAT arc trajectory selection, with hundreds of thousands of beamlets ‐ in clinically feasible timeframes. The flexibility of this framework makes it as a strong candidate for use in a variety of other very large‐scale treatment planning tasks and clinical workflows.

Neph, Ryan↗

A new method for wind speed forecasting based on copula theory

Highlights: • A copula method is developed to determine the representative wind speed in wind farm. • The method proposed can determine the joint distribution without assuming the variables to be independent. • The representative wind speed obtained by the conditional distribution is more reasonably. How to determine representative wind speed is crucial in wind resource assessment. Accurate wind resource assessments are important to wind farms development. Linear regressions are usually used to obtain the representative wind speed. However, terrain flexibility of wind farm and long distance between wind speed sites often lead to low correlation. In this study, copula method is used to determine the representative year's wind speed in wind farm by interpreting the interaction of the local wind farm and the meteorological station. The result shows that the method proposed here can not only determine the relationship between the local anemometric tower and nearby meteorological station through Kendall's tau, but also determine the joint distribution without assuming the variables to be independent. Moreover, the representative wind data can be obtained by the conditional distribution much more reasonably. We hope this study could provide scientific reference for accurate wind resource assessments.

54 ENVIRONMENTAL SCIENCES↗

VMAT QA: Measurement-guided 4D dose reconstruction on a patient

Purpose: To develop and validate a volume-modulated arc therapy (VMAT) quality assurance (QA) tool that takes as input a time-resolved, low-density ({approx}10 mm) cylindrical surface dose map from a commercial helical diode array, and outputs a high density, volumetric, time-resolved dose matrix on an arbitrary patient dataset. This first validation study is limited to a homogeneous 'patient.'Methods: A VMAT treatment is delivered to a diode array phantom (ARCCHECK, Sun Nuclear Corp., Melbourne, FL). 3DVH software (Sun Nuclear) derives the high-density volumetric dose using measurement-guided dose reconstruction (MGDR). MGDR cylindrical phantom results are then used to perturb the three-dimensional (3D) treatment planning dose on the patient dataset, producing a semiempirical volumetric dose grid. Four-dimensional (4D) dose reconstruction on the patient is also possible by morphing individual sub-beam doses instead of the composite. For conventional (3D) dose comparison two methods were developed, using the four plans (Multi-Target, C-shape, Mock Prostate, and Head and Neck), including their structures and objectives, from the AAPM TG-119 report. First, 3DVH and treatment planning system (TPS) cumulative point doses were compared to ion chamber in a cube water-equivalent phantom ('patient'). The shape of the phantom is different from the ARCCHECK and furthermore the targets were placed asymmetrically. Second, coronal and sagittal absolute film dose distributions in the cube were compared with 3DVH and TPS. For time-resolved (4D) comparisons, three tests were performed. First, volumetric dose differences were calculated between the 3D MGDR and cumulative time-resolved patient (4D MGDR) dose at the end of delivery, where they ideally should be identical. Second, time-resolved (10 Hz sampling rate) ion chamber doses were compared to cumulative point dose vs time curves from 4D MGDR. Finally, accelerator output was varied to assess the linearity of the 4D MGDR with global fluence change. Results: Across four TG-119 plans, the average PTV point dose difference in the cube between 3DVH and ion chamber is 0.1 {+-} 1.0%. Average film vs TPS {gamma}-analysis passing rates are 83.0%, 91.1%, and 98.4% for 1%/2 mm, 2%/2 mm, and 3%/3 mm threshold combinations, respectively, while average film vs 3DVH {gamma}-analysis passing rates are 88.6%, 96.1%, and 99.5% for the same respective criteria. 4D MGDR was also sufficiently accurate. First, for 99.5% voxels in each case, the doses from 3D and 4D MGDR at the end of delivery agree within 0.5%local dose-error/1 mm distance. Moreover, all failing voxels are confined to the edge of the cylindrical reconstruction volume. Second, dose vs time curves track between the ion chamber and 4D MGDR within 1%. Finally, 4D MGDR dose changes linearly with the accelerator output: the difference between cumulative ion chamber and MGDR dose changed by no more than 1% (randomly) with the output variation range of 10%. Conclusions: Even for a well-commissioned TPS, comparison metrics show better agreement on average to MGDR than to TPS on the arbitrary-shaped measurable 'patient.' The method requires no more accelerator time than standard QA, while producing more clinically relevant information. Validation in a heterogeneous thoracic phantom is under way, as is the ultimate application of 4D MGDR to virtual motion studies.

60 APPLIED LIFE SCIENCES↗

Efficient Aho-Corasick String Matching on Emerging Multicore Architectures

String matching algorithms are critical to several scientific fields. Beside text processing and databases, emerging applications such as DNA protein sequence analysis, data mining, information security software, antivirus, ma- chine learning, all exploit string matching algorithms [3]. All these applica- tions usually process large quantity of textual data, require high performance and/or predictable execution times. Among all the string matching algorithms, one of the most studied, especially for text processing and security applica- tions, is the Aho-Corasick algorithm. 1 2 Book title goes here Aho-Corasick is an exact, multi-pattern string matching algorithm which performs the search in a time linearly proportional to the length of the input text independently from pattern set size. However, depending on the imple- mentation, when the number of patterns increase, the memory occupation may raise drastically. In turn, this can lead to significant variability in the performance, due to the memory access times and the caching effects. This is a significant concern for many mission critical applications and modern high performance architectures. For example, security applications such as Network Intrusion Detection Systems (NIDS), must be able to scan network traffic against very large dictionaries in real time. Modern Ethernet links reach up to 10 Gbps, and malicious threats are already well over 1 million, and expo- nentially growing [28]. When performing the search, a NIDS should not slow down the network, or let network packets pass unchecked. Nevertheless, on the current state-of-the-art cache based processors, there may be a large per- formance variability when dealing with big dictionaries and inputs that have different frequencies of matching patterns. In particular, when few patterns are matched and they are all in the cache, the procedure is fast. Instead, when they are not in the cache, often because many patterns are matched and the caches are continuously thrashed, they should be retrieved from the system memory and the procedure is slowed down by the increased latency. Efficient implementations of string matching algorithms have been the fo- cus of several works, targeting Field Programmable Gate Arrays [4, 25, 15, 5], highly multi-threaded solutions like the Cray XMT [34], multicore proces- sors [19] or heterogeneous processors like the Cell Broadband Engine [35, 22]. Recently, several researchers have also started to investigate the use Graphic Processing Units (GPUs) for string matching algorithms in security applica- tions [20, 10, 32, 33]. Most of these approaches mainly focus on reaching high peak performance, or try to optimize the memory occupation, rather than looking at performance stability. However, hardware solutions supports only small dictionary sizes due to lack of memory and are difficult to customize, while platforms such as the Cell/B.E. are very complex to program.

Tumeo, Antonino↗

Capture Cross Section Measurements in {sup nat}Fe and {sup 181}Ta from 1 to 2000 keV Using a New C6D6 Detector Array

A new array of four C6D6 detectors has been developed at the Rensselaer Polytechnic Institute Gaerttner LINAC center for the purposes of measuring neutron capture cross sections in the keV resonance region with low sensitivity to scattered neutrons. The new detection apparatus incorporates low-mass, low cross-section materials to reduce neutron sensitivity, and uses digital data acquisition equipment to enable saving of the full waveform output of each detector module for offline analysis. Capture yields are determined by applying the total energy method and pulse height weighting technique during the analysis of the saved data. Measurements have been performed on samples of iron and tantalum using the new system, with results consistent with existing data libraries. (authors)

42 ENGINEERING↗

Scaling relations of the properties for CO resolved structures in nearby spiral galaxies

Complementing the observations on the eastern part of galaxy NGC 6946 presented in a previous work, we report high spatial resolution observations of giant molecular clouds (GMCs) in the nearby spiral galaxies M101 and NGC 628 obtained with the Combined Array for Research in Millimeter-wave Astronomy (CARMA). We observed CO(1→0) over regions with active star formation extending from 2 to 15 kpc galactocentric radius. Higher resolution observations of CO(2→1) toward the brightest regions observed in CO(1→0) have allowed us to resolve some of the largest GMCs. We have recovered short-spacing u–v components by using single dish observations from the Nobeyama 45 m and IRAM 30 m telescopes. Using the automated CPROPS algorithm we identified 112 CO complexes in the CO(1→0) maps and 144 GMCs in the CO(2→1) maps. Using a Bayesian fitting approach, we generate scaling relations for the sizes, line widths, and virial masses of the structures identified in this work. We do not find evidence for a tight power-law relation between size and line width, although the limited dynamic range in cloud size remains a clear issue in our analysis. Additionally, we use a Bayesian approach to analyze the scaling relation between the star formation and molecular gas surface density, known as the Kennicutt–Schmidt relation. When we perform our analysis using the boundaries of the structures identified by CPROPS, we find that the distribution of slopes are broadly distributed, mainly due to the limited dynamic range of our measured Σ{sub H{sub 2}}. In the case of the CO(1→0) complexes, the slope distributions are most consistent with super-linear relations, although sub-linear relations cannot be excluded for NGC 628 and NGC 6946. The GMCs from higher resolution CO(2→1) maps follow a similar behavior, but with larger scatter. As a complementary study, we use the Bayesian approach to analyze the Kennicutt–Schmidt relation for a uniform grid covering the areas surveyed, and with Σ{sub H{sub 2}} non-detections included in the analysis. The distributions of slopes is consistent with sub-linear relations for NGC 6946 and NGC 628, but is less constrained for M101. This picture is preserved after a 24 μm background component is subtracted from the Σ{sub SFR} measurements. On-arm regions tend to have higher star formation rates than inter-arm regions. Similar to what we find in our study of the eastern part of NGC 6946, in M101 we find regions where the star formation efficiency (SFE) shows marked peaks at specific galoctocentric radii. On the other hand, the distribution of SFE in NGC 628 is more contiguous. We hypothesize that differences in the distribution of SFE may be indicative of different processes driving the spiral structure.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-227: Least Restrictive Assignment of Dose-Distance Differences (LRAD) in IMRT On a Conventional Linac

Purpose: To develop a method to compare dose distributions based on the least restrictive of dose and distance differences, and to evaluate the method for IMRT QA on a conventional linac. Methods: Lrad is defined as the least restrictive of the dose difference at each point in the distributions being compared (%D), with dose normalized by the same factor, and the distance to agreement (DTA in millimeters), limited to directions parallel and perpendicular to MLC motion. If %D<%Do, Lrad=%D. Otherwise, if L=%D/DTA>Lo, Lrad=DTA, else Lrad=%D. Lrad fails at any point when Lrad>DTAo or Lrad>%Do. We compared LRAD (Lo=1%/mm, DTAo=2mm, %Do=2%) with Gamma index tool (2%/2mm pass/fail criteria) for IMRT QA with 2D detector arrays. Dose distribution measured for 6 MV and 18 MV x-rays for various field sizes and shapes, including 6 IMRT plans, were compared to measurements made with output, beam flatness, beam symmetry, MLC leaf positions, and detector array translation and rotation adjusted at up to twice published acceptable tolerance. Results: LRAD was more effective than Gamma in detecting a 2% drift in output (dose per monitor unit), 1–2 mm drifts in MLC leaf position for 1–8 leaves in the field, and beam flatness and symmetry drifts that resulted in a 3% change in the off-axis ratio. LRAD and Gamma were equally effective for larger output changes and for detector translations and rotations. For all ∼400 measurements performed, LRAD detected 78% of the error and Gamma detected 52% of the errors. By using a color scale to display dose differences and grey scale for spatial errors, the reason for failure was self evident, whether it be beam or mechanical changes. Conclusion: LRAD proved to be advantageous in its ability to detect and distinguish between realistic changes in beam and mechanical settings in comparison to the Gamma Index.

60 APPLIED LIFE SCIENCES↗

Establishing an optimized patient-specific verification program for volumetric modulated arc therapy

Quality assurance (QA) of volumetric modulated arc therapy (VMAT) increases the workload significantly. We compared the results from 4 verification methods to establish an efficient VMAT QA. Planning for VMAT treatments was carried out for 40 consecutive patients. Pretreatment verifications were carried out with ion chamber array Physikalish-Technische Werkstätten (PTW729), electronic portal dosimetry (EPID), ion chamber measurements, and independent dose calculation with Diamond program. 2D analyses were made using the gamma analysis (3 mm distance to agreement and 3% dose difference relative to maximum, 10% dose threshold). Average point dose difference calculated by Eclipse relative to ion chamber measurements and Diamond were 0.1%±0.9% and 0.6%±2.2%, respectively. Average pass rate for PTW729 was 99.2%±1.9% and 98.3%±1.3% for EPID. The total required time (linac occupancy time given in parentheses) for each QA method was: PTW729 43.5 minutes (26.5 minutes), EPID 14.5 minutes (2.5 minutes), ion chamber 34.5 minutes (26.5 minutes), and Diamond 12.0 minutes (0 minute). The results were consistent and allowed us to establish an optimized protocol, considering safety and accuracy as well as workload, consisting of 2 verification methods: EPID 2D analysis and independent dose calculation.

61 RADIATION PROTECTION AND DOSIMETRY↗

High resolution x-ray Thomson scattering measurements from cryogenic hydrogen jets using the linac coherent light source

We present the first spectrally resolved measurements of x-rays scattered from cryogenic hydrogen jets in the single photon counting limit. The 120 Hz capabilities of the LCLS, together with a novel hydrogen jet design [J. B. Kim et al., Rev. Sci. Instrum. (these proceedings)], allow for the ability to record a near background free spectrum. Such high-dynamic-range x-ray scattering measurements enable a platform to study ultra-fast, laser-driven, heating dynamics of hydrogen plasmas. This measurement has been achieved using two highly annealed pyrolytic graphite crystal spectrometers to spectrally resolve 5.5 keV x-rays elastically and inelastically scattered from cryogenic hydrogen and focused on Cornell-SLAC pixel array detectors [S. Herrmann et al., Nucl. Instrum. Methods Phys. Res., Sect. A 718, 550 (2013)].

43 PARTICLE ACCELERATORS↗

Pit rim decomposition into multiple quantum dots on surfaces of epitaxial thin films grown on pit-patterned substrates

Here, we report results of dynamical simulations according to an experimentally validated surface morphological evolution model on the formation of regular arrays of quantum dot molecules (QDMs) consisting of 1D arrays of smaller interacting quantum dots (QDs). These QD arrays form along the sides of each pit rim on the surface of a coherently strained thin film epitaxially deposited on a semiconductor substrate, the surface of which consists of a periodic pattern of inverted prismatic pits with rectangular pit openings. We find that this complex QDM pattern results from the decomposition of the pit rim from a “quantum fortress” with four elongated QDs into four 1D arrays of multiple smaller QDs arranged along each side of the pit rim. Systematic parametric analysis indicates that varying the pit opening dimensions and the pit wall inclination directly impacts the number of QDs in the resulting QDM pattern, while varying the pit depth only affects the dimensions of the QDs in the nanostructure pattern. Therefore, the number, arrangement, and sizes of QDs in the resulting pattern of QDMs on the film surface can be engineered precisely by proper tuning of the pit design parameters. Our simulation results are supported by predictions of morphological stability analysis, which explains the pit rim decomposition into multiple QDs as the outcome of a tip-splitting instability and provides a fundamental characterization of the post-instability nanostructure pattern. Our theoretical findings can play a vital role in designing optimal semiconductor surface patterns toward enabling future nanofabrication technologies.

36 MATERIALS SCIENCE↗

Implosion dynamics of a megampere wire-array Z-pinch with an inner low-density foam shell at the Angara-5-1 facility

The implosion dynamics of a pinch with a highly inhomogeneous initial axial distribution of the load mass was studied experimentally. A cascade array consisting of a double nested tungsten wire array and a coaxial inner cylindrical shell located symmetrically with respect to the high-voltage electrodes was used as a load of the Angara-5-1 high-current generator. The cylindrical foam shell was half as long as the cathode− anode gap, and its diameter was equal to the diameter of the inner wire array. It is shown experimentally that two stages are typical of the implosion dynamics of such a load: the formation of two separate pinches formed as a result of implosion of the wire array near the cathode and anode and the subsequent implosion of the central part of the load containing the cylindrical foam shell. The conditions are determined at which the implosion of the central part of the pinch with the foam cylinder is preceded by intense irradiation of the foam with the soft X-ray (SXR) emission generated by the near-electrode pinches and converting it into the plasma state. Using such a load, which models the main elements of the scheme of a dynamic hohlraum for inertial confinement fusion, it is possible to increase the efficiency of interaction between the outer accelerated plasma sheath and the inner foam shell by preionizing the foam with the SXR emission of the near-electrode pinches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

COPSS II: the molecular gas content of ten million cubic megaparsecs at redshift z ∼ 3

We present a measurement of the abundance of carbon monoxide in the early universe, utilizing the final results from the CO Power Spectrum Survey (COPSS). Between 2013 and 2015, we performed observations with the Sunyaev–Zel’dovich Array to measure aggregate CO emission from z∼3 galaxies with the intensity mapping technique. Data were collected on 19 fields, covering an area of 0.7 square degrees, over the frequency range 27--35 GHz. With these data, along with data analyzed in COPSS I, we are able to observe the CO(1–0) transition within the redshift range z=2.3--3.3 for spatial frequencies between k=0.5--10 h Mpc{sup −1}, spanning a comoving volume of 4.9×10{sup 6} h{sup −3} Mpc{sup 3}. We present estimates of contributions from continuum sources and ground illumination within our measurement. We constrain the amplitude of the CO power spectrum to P{sub CO}=3.0{sub −1.3}{sup +1.3}×10{sup 3} μK{sup 2}(h{sup −1}Mpc){sup 3}, or Δ{sub CO}{sup 2}(k=1 h Mpc{sup −1})=1.5{sub −0.7}{sup +0.7}×10{sup 3} μK{sup 2}, at 68% confidence, and P{sub CO}>0 at 98.9% confidence. These results are a factor of 10 improvement in sensitivity compared to those of COPSS I. With this measurement, we constrain on the CO(1–0) galaxy luminosity function at z∼3. Assuming that CO emission is proportional to halo mass and using theoretical estimates of the scatter in this relationship, we constrain the ratio of CO(1--0) luminosity to halo mass to A{sub CO}=6.3{sub −2.1}{sup +1.4}×10{sup −7} L{sub ⊙} M{sub ⊙}{sup −1}. Assuming a Milky Way-like linear relationship between CO luminosity and molecular gas mass, we estimate a mass fraction of molecular gas of f{sub H{sub 2}}=5.5{sub −2.2}{sup +3.4}×10{sup −2} for halos with masses of ∼10{sup 12}M{sub ⊙}. Using theoretical estimates for the scaling of molecular gas mass fraction and halo mass, we estimate the cosmic molecular gas density to be ρ{sub z∼3}(H{sub 2})=1.1{sub −0.4}{sup +0.7}×10{sup 8} M{sub ⊙} Mpc{sup −3}.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling the neutral hydrogen distribution in the post-reionization Universe: intensity mapping

We model the distribution of neutral hydrogen (HI) in the post-reionization era and investigate its detectability in 21 cm intensity mapping with future radio telescopes like the Square Kilometer array (SKA). We rely on high resolution hydrodynamical N-body simulations that have a state-of-the-art treatment of the low density photoionized gas in the inter-galactic medium (IGM). The HI is assigned a-posteriori to the gas particles following two different approaches: a halo-based method in which HI is assigned only to gas particles residing within dark matter halos; a particle-based method that assigns HI to all gas particles using a prescription based on the physical properties of the particles. The HI statistical properties are then compared to the observational properties of Damped Lyman-α Absorbers (DLAs) and of lower column density systems and reasonable good agreement is found for all the cases. Among the halo-based method, we further consider two different schemes that aim at reproducing the observed properties of DLAs by distributing HI inside halos: one of this results in a much higher bias for DLAs, in agreement with recent observations, which boosts the 21 cm power spectrum by a factor ∼ 4 with respect to the other recipe. Furthermore, we quantify the contribution of HI in the diffuse IGM to both Ω{sub HI} and the HI power spectrum finding to be subdominant in both cases. We compute the 21 cm power spectrum from the simulated HI distribution and calculate the expected signal for both SKA1-mid and SKA1-low configurations at 2.4 ≤ z ≤ 4. We find that SKA will be able to detect the 21 cm power spectrum, in the non-linear regime, up to k ∼ 1 h/Mpc for SKA1-mid and k ∼ 5 h/Mpc for SKA1-low with 100 hours of observations. We also investigate the perspective of imaging the HI distribution. Our findings indicate that SKA1-low could detect the most massive HI peaks with a signal to noise ratio (SNR) higher than 5 for an observation time of about 1000 hours at z = 4, for a synthesized beam width of 2'. Detection at redshifts z≥2.4 with SKA1-mid would instead require a much longer observation time to achieve a comparable SNR level.

79 ASTRONOMY AND ASTROPHYSICS↗

Diagnostics for Z-pinch implosion experiments on PTS

The preliminary experiments of wire array implosion were performed on PTS, a 10 MA z-pinch driver with a 70 ns rise time. A set of diagnostics have been developed and fielded on PTS to study pinch physics and implosion dynamics of wire array. Radiated power measurement for soft x-rays was performed by multichannel filtered x-ray diode array, and flat spectral responses x-ray diode detector. Total x-ray yield was measured by a calibrated, unfiltered nickel bolometer which was also used to obtain pinch power. Multiple time-gated pinhole cameras were used to produce spatial-resolved images of x-ray self-emission from plasmas. Two time-integrated pinhole cameras were used respectively with 20-μm Be filter and with multilayer mirrors to record images produced by >1-keV and 277±5 eV self-emission. An optical streak camera was used to produce radial implosion trajectories, and an x-ray streak camera paired with a horizontal slit was used to record a continuous time-history of emission with one-dimensional spatial resolution. A frequency-doubled Nd:YAG laser (532 nm) was used to produce four frame laser shadowgraph images with 6 ns time interval. We will briefly describe each of these diagnostics and present some typical results from them.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Frequency-Dependent Properties of Magnetic Nanoparticle Crystals

In the proposed research program we will investigate the time- and frequency-dependent behavior of ordered nanoparticle assemblies, or nanoparticle crystals. Magnetostatic interactions are long-range and anisotropic, and this leads to complex behavior in nanoparticle assemblies, particularly in the time- and frequency-dependent properties. We hypothesize that the high frequency performance of composite materials has been limited because of the range of relaxation times; if a composite is a dipolar ferromagnet at a particular frequency, it should have the advantages of a single phase material, but without significant eddy current power losses. Arrays of surfactant-coated monodomain magnetic nanoparticles can exhibit long-range magnetic order that is stable over time. The magnetic domain size and location of domain walls is governed not by structural grain boundaries but by the shape of the array, due to the local interaction field. Pores or gaps within an assembly pin domain walls and limit the domain size. Measurements of the magnetic order parameter as a function of temperature showed that domains can exist at high temoerature, and that there is a collective phase transition, just as in an exchange-coupled ferromagnet. Dipolar ferromagnets are not merely of fundamental interest; they provide an interesting alternative to exchange-based ferromagnets. Dipolar ferromagnets made with high moment metallic particles in an insulating matrix could have high permeability without large eddy current losses. Such nanocomposites could someday replace the ferrites now used in phase shifters, isolators, circulators, and filters in microwave communications and radar applications. We will investigate the time- and frequency-dependent behavior of nanoparticle crystals with different magnetic core sizes and different interparticle barrier resistances, and will measure the magnetic and electrical properties in the DC, low frequency (0.1 Hz - 1 kHz), moderate frequency (10 Hz - 500 MHz), and high frequency (up to 20 GHz) regimes. Our results will demonstrate whether a DC dipolar ferromagnet shows collective frequency-dependent reponse similar to that of an exchange-based ferromagnet, and will provide data for comparison of optimal nanocomposite properties with those of ferrites used in high frequency applications. Both the magnetic and electronic response of the composites will be examined in order to determine the frequency range where hopping conductivity leads to significant eddy current power losses. In the high frequency regime we will look for evidence of spin wave quantization and the resulting decrease in non-linear spin wave processes that could affect the performance of high frequency magnetic devices.

36 MATERIALS SCIENCE↗

Impacts of year-to-year weather variability and inter-panel spacing on agrivoltaic crop yields in Massachusetts

Deployment of utility-scale solar power plants could lead to agricultural land-use changes. Agrivoltaics, a dual land use combining solar and agriculture on the same land, can provide multiple environmental benefits, including improving soil quality and water use efficiency. The body of agrivoltaic field data is still growing, and crop responses to different solar configurations under different local climates are highly varied. We investigate the impact of adding spacing between adjacent solar panels in a fixed-tilt system to improve light diffusion to crops. For four crops (broccoli, peppers, kale, Swiss chard) grown across 3 years in an agrivoltaic system in Massachusetts, we found that only kale had a linearly increasing trend as the inter-panel spacing increased from 0.6 m to 1.5 m (2 ft to 5 ft). However, there were significant year-to-year differences in the yield of agrivoltaic versus control fields. Agrivoltaic and full sun fields produced equivalent yields in a hot, dry year, whereas the full-sun control beds produced more salable yield for all four crops in a warm, wet year. This demonstrates variability of agricultural outcomes and the need for more multi-year studies to ensure agrivoltaic impacts are not under- or overestimated.

14 SOLAR ENERGY↗

SU-F-T-518: Development and Characterization of a Gated Treatment System Implemented with An In-House Optical Tracking System and the Elekta Response Interface

Purpose: To report the development and characterization of the first in-house gating system implemented with an optical tracking system (OTS) and the Elekta Response™ interface. Methods: The Response™ connects a patient tracking system with a linac, enabling the tracking system to control radiation delivery. The developed system uses an in-house OTS to monitor patient breathing. The OTS consists of two infrared-based cameras, tracking markers affixed on patient. It achieves gated or breath-held (BH) treatment by calling beam ON/OFF functions in the Response™ dynamic-link library (DLL). A 4D motion phantom was used to evaluate its dosimetric and time delay characteristics. Two FF- and two FFF-IMRT beams were delivered in non-gated, BH and gated mode. The sinusoidal gating signal had a 6 sec period and 15 mm amplitude. The duty cycle included 10%, 20%, 30% and 50%. The BH signal was adapted from the sinusoidal wave by inserting 15 sec BHs. Each delivery was measured with a 2D diode array (MapCHECK™) and compared with the non-gated delivery using gamma analysis (3%). The beam ON/OFF time was captured using the service graphing utility of the linac. Results: The gated treatments were successfully delivered except the 10% duty cycle. The BH delivery had perfect agreement (100%) with non-gated delivery; the agreement of gated delivery decreased from 99% to 88% as duty cycle reduced from 50% to 20%. The beam on/off delay was on average 0.25/0.06 sec. The delivery time for the 50%, 30% and 20% duty cycle increased by 29%, 71% and 139%, respectively. No dosimetric or time delay difference was noticed between FF- and FFF-IMRT beams. Conclusion: The in-house gating system was successfully developed with dosimetric and time delay characteristics in line with published results for commercial systems. It will be an important platform for further research and clinical development of gated treatment.

43 PARTICLE ACCELERATORS↗