Search NASA⌕ Search

SEARCH · Search NASA

Results for “load control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Structural health and prognostics management for the enhancement of offshore wind turbine operations and maintenance strategies

Offshore wind turbines are an attractive source for clean and renewable energy for reasons including their proximity to population centers and higher capacity factors. One obstacle to the more widespread installation of offshore wind turbines in the USA, however, is that recent projections of offshore operations and maintenance costs vary from two to five times the land-based costs. One way in which these costs could be reduced is through use of a structural health and prognostics management (SHPM) system as part of a condition-based maintenance paradigm with smart loads management. Our paper contributes to the development of such strategies by developing an initial roadmap for SHPM, with application to the blades. One of the key elements of the approach is a multiscale simulation approach developed to identify how the underlying physics of the system are affected by the presence of damage and how these changes manifest themselves in the operational response of a full turbine. A case study of a trailing edge disbond is analysed to demonstrate the multiscale sensitivity of damage approach and to show the potential life extension and increased energy capture that can be achieved using simple changes in the overall turbine control and loads management strategy. Finally, the integration of health monitoring information, economic considerations such as repair costs versus state of health, and a smart loads management methodology provides an initial roadmap for reducing operations and maintenance costs for offshore wind farms while increasing turbine availability and overall profit.

17 WIND ENERGY↗

Turnkey Heating, Ventilating, and Air Conditioning and Lighting Retrofit Solution Combining Energy Efficiency and Demand Response Benefits

NREL worked with the Bonneville Power Administration's Technology Innovation Office to demonstrate a turnkey, retrofit technology that combines demand response (DR) and energy efficiency (EE) benefits for HVAC and lighting in retail buildings. As a secondary benefit, we also controlled various plug loads and electric hot water heaters (EHWH). The technology demonstrated was Transformative Wave's eIQ Building Management System (BMS) automatically responding to DR signals. The BMS controlled the HVAC rooftop units (RTU) using the CATALYST retrofit solution also developed by Transformative Wave. The non-HVAC loads were controlled using both hardwired and ZigBee wireless communication. The wireless controllers, manufactured by Autani, were used when the building's electrical layout was too disorganized to leverage less expensive hardwired control. The six demonstration locations are within the Seattle metro area. Based on the assets curtailed by the BMS at each location, we projected the DR resource. We were targeting a 1.7 W/ft2 shed for the summer Day-Ahead events and a 0.7 W/ft2 shed for the winter events. While summarized in Table ES-1, only one summer DR event was conducted at Casino #2.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Drones for aerodynamic and structural testing /DAST/ - A status report

A program for providing research data on aerodynamic loads and active control systems on wings with supercritical airfoils in the transonic speed range is described. Analytical development, wind tunnel tests, and flight tests are included. A Firebee II target drone vehicle has been modified for use as a flight test facility. The program currently includes flight experiments on two aeroelastic research wings. The primary purpose of the first flight experiment is to demonstrate an active control system for flutter suppression on a transport-type wing. Design and fabrication of the wing are complete and after installing research instrumentation and the flutter suppression system, flight testing is expected to begin in early 1979. The experiment on the second research wing - a fuel-conservative transport type - is to demonstrate multiple active control systems including flutter suppression, maneuver load alleviation, gust load alleviation, and reduce static stability. Of special importance for this second experiment is the development and validation of integrated design methods which include the benefits of active controls in the structural design.

Murrow, H. N.↗

Dual-arm manipulators with adaptive control

The described and improved multi-arm invention of this application presents three strategies for adaptive control of cooperative multi-arm robots which coordinate control over a common load. In the position-position control strategy, the adaptive controllers ensure that the end-effector positions of both arms track desired trajectories in Cartesian space despite unknown time-varying interaction forces exerted through a load. In the position-hybrid control strategy, the adaptive controller of one arm controls end-effector motions in the free directions and applied forces in the constraint directions; while the adaptive controller of the other arm ensures that the end-effector tracks desired position trajectories. In the hybrid-hybrid control strategy, the adaptive controllers ensure that both end-effectors track reference position trajectories while simultaneously applying desired forces on the load. In all three control strategies, the cross-coupling effects between the arms are treated as disturbances which are compensated for by the adaptive controllers while following desired commands in a common frame of reference. The adaptive controllers do not require the complex mathematical model of the arm dynamics or any knowledge of the arm dynamic parameters or the load parameters such as mass and stiffness. Circuits in the adaptive feedback and feedforward controllers are varied by novel adaptation laws.

Seraji, Homayoun↗

Method and apparatus for adaptive force and position control of manipulators

The described and improved multi-arm invention of this application presents three strategies for adaptive control of cooperative multi-arm robots which coordinate control over a common load. In the position-position control strategy, the adaptive controllers ensure that the end-effector positions of both arms track desired trajectories in Cartesian space despite unknown time-varying interaction forces exerted through a load. In the position-hybrid control strategy, the adaptive controller of one arm controls end-effector motions in the free directions and applied forces in the constraint directions; while the adaptive controller of the other arm ensures that the end-effector tracks desired position trajectories. In the hybrid-hybrid control strategy, the adaptive controllers ensure that both end-effectors track reference position trajectories while simultaneously applying desired forces on the load. In all three control strategies, the cross-coupling effects between the arms are treated as disturbances which are compensated for by the adaptive controllers while following desired commands in a common frame of reference. The adaptive controllers do not require the complex mathematical model of the arm dynamics or any knowledge of the arm dynamic parameters or the load parameters such as mass and stiffness. Circuits in the adaptive feedback and feedforward controllers are varied by novel adaptation laws.

Seraji, Homayoun↗

VOLTTRON-Based System for Providing Ancillary Services with Residential Building Loads

Ancillary services entail controlled modulation of building equipment to maintain a stable balance of generation and load in the power system. Ancillary services include frequency regulation and contingency reserves, whose acting time ranges from several seconds to several minutes. Many pilot studies have been implemented to use industrial loads to provide ancillary services, and some have explored services from commercial building loads or electric vehicle charging loads. Residential loads, such as space conditioning and water heating, represent a largely untapped resource for providing ancillary services. The residential building sector accounts for a significant fraction of the total electricity use in the United States. Many loads in residential buildings are flexible and could potentially be curtailed or shifted at the request of the grid. However, there are many barriers that prevent residential loads being widely used for ancillary services. One of the major technical barriers is the lack of communication capabilities between end-use devices and the grid. End-use devices need to be able to receive the automatic generation control (AGC) signal from the grid operator and supply certain types of telemetry to verify response. With the advance of consumer electronics, communication-enabled, or 'connected,' residential equipment has emerged to overcome the communication barrier. However, these end-use devices have introduced a new interoperability challenge due to the existence of numerous standards and communication protocols among different end devices. In this paper, we present a VOLTTRON-based system that overcomes these technical challenges and provides ancillary services with residential loads. VOLTTRON is an open-source control and sensing platform for building energy management, facilitating interoperability solutions for end devices. We have developed drivers to communicate and control different types of end devices through standard-based interfaces, manufacturer-provided application programming interfaces, and proprietary communication interfaces. We document the ability to manage nine appliances, using four different standards or proprietary communication methods. A hardware-in-the-loop test was performed in a laboratory environment where the loads of a laboratory home and a large number of simulated homes are controlled by an aggregator. Upon receipt of an AGC signal, the VOLTTRON home energy management system (HEMS) of the laboratory home adjusts the end-device controls based on the comfort criteria set by the end users and sends telemetry to the aggregator to verify response. The aggregator then sends the AGC signal to other simulated homes in attempts to match the utility request as closely as possible. Frequency regulation is generally considered a higher value service than other ancillary services but it is also more challenging due to the constraint of short response time. A frequency regulation use case has been implemented with the regulation signals sent every 10 seconds. Experimental results indicate that the VOLTTRON-controlled residential loads are able to be controlled with sufficient fidelity to enable an aggregator to meet frequency regulation requirements. Future work is warranted, such as understanding the impact of this type of control on equipment life, and market requirements needed to open up residential loads to ancillary service aggregators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-disciplinary optimization of aeroservoelastic systems

The purpose of the research project was to continue the development of new methods for efficient aeroservoelastic analysis and optimization. The main targets were as follows: to complete the development of analytical tools for the investigation of flutter with large stiffness changes; to continue the work on efficient continuous gust response and sensitivity derivatives; and to advance the techniques of calculating dynamic loads with control and unsteady aerodynamic effects. An efficient and highly accurate mathematical model for time-domain analysis of flutter during which large structural changes occur was developed in cooperation with Carol D. Wieseman of NASA LaRC. The model was based on the second-year work 'Modal Coordinates for Aeroelastic Analysis with Large Local Structural Variations'. The work on continuous gust response was completed. An abstract of the paper 'Continuous Gust Response and Sensitivity Derivatives Using State-Space Models' was submitted for presentation in the 33rd Israel Annual Conference on Aviation and Astronautics, Feb. 1993. The abstract is given in Appendix A. The work extends the optimization model to deal with continuous gust objectives in a way that facilitates their inclusion in the efficient multi-disciplinary optimization scheme. Currently under development is a work designed to extend the analysis and optimization capabilities to loads and stress considerations. The work is on aircraft dynamic loads in response to impulsive and non-impulsive excitation. The work extends the formulations of the mode-displacement and summation-of-forces methods to include modes with significant local distortions, and load modes. An abstract of the paper,'Structural Dynamic Loads in Response to Impulsive Excitation' is given in appendix B. Another work performed this year under the Grant was 'Size-Reduction Techniques for the Determination of Efficient Aeroservoelastic Models' given in Appendix C.

Karpel, Mardechay↗

Advanced concept considerations for STOL short-haul systems

Design, performance, and economic tradeoffs for STOL short-haul systems are presented. The analyses showed that quiet, short-field aircraft can be economically viable and provide benefits to airport congestion and to community noise relief. The objective of the studies was to compare and evaluate propulsive-lift systems and low-wing-loading aircraft provided with ride quality control and gust load alleviation, and to determine fuel consumption and cost tradeoffs, along with recommendations for development of technology, noise criteria, and airport planning. In the low density arena, the optimum aircraft sized for less than 50 passengers have active controls for ride quality and gust alleviation; turboprop propulsion offers significant cost and fuel saving with no appreciable block time penalty for the short typical stage lengths (on the order of 150 miles). In the high density arena, high bypass-ratio fan-powered aircraft, with design cruise speed of 0.7 to 0.75M and range capability to 1500 miles, are considered to be optimum. Field performance of 3000 feet or better can be achieved by the hybrid over-the-wing/internally blown flap concept with viable economics and low fuel consumption. Mechanical flap aircraft with high bypass-ratio engines are indicated to be superior for field lengths of 3500 feet or more. Technology development of propulsive lift is required, and further definition of the best fan-powered engine for low noise and low fuel consumption is needed.

Sweet, H. S.↗

Influence on Structural Loading of a Wave Energy Converter by Controlling Variable-Geometry Components and the Power Take-Off

Oceans are harsh environments and can impose significant loads on deployed structures. A wave energy converter (WEC) should be designed to maximize the energy absorbed while ensuring the operating wave condition does not exceed the failure limits of the device itself. Therefore, the loads endured by the support structure are a design constraint for the system. Furthermore, the WEC should be adaptable to different sea states. Herethis work uses a WEC-Sim model of a variable-geometry oscillating wave energy converter (VGOSWEC) mounted on a support structure simulated under different wave scenarios. A VGOSWEC resembles a paddle pitching about a fixed hinge perpendicular to the incoming wave fronts. The geometry of the VGOSWEC is varied by opening a series of controllable flaps on the pitching paddle when the structure experiences threshold loads. It is hypothesized that opening the flaps should result in load shedding at the base of the support structure by reducing the moments about the hinge axis. This work compares the hydrodynamic coefficients, natural periods, and response amplitude operators from completely closed to completely open configurations of the controllable flaps. This work shows that the completely open configuration can reduce the pitch and surge loads on the base of the support structure by as much as 80%. Increased loads at the structure’s natural period can be mitigated by an axial power take-off damping acting as an additional design parameter to control the loads at the WEC’s support structure.

16 TIDAL AND WAVE POWER↗

Integrated ELM and divertor power flux control using RMPs with low input torque in EAST in support of the ITER research plan

Experiments have been carried out at the EAST tokamak to study ITER-relevant scenario integration issues, related to edge localized mode (ELM) control in H-mode plasmas by the application of three-dimensional (3D) resonant magnetic perturbations (RMPs), which have a large impact on the execution of the ITER research plan. The EAST experiments have successfully demonstrated ELM suppression at normalized torque inputs similar to ITER. The application of RMP fields with high toroidal mode number (n = 4) reduces the impact of ELM control on energy and particle confinement compared to those use lower n (n = 1, 2) RMPs. Injection of successive pellets is found to be effective in increasing the plasma density in ELM-suppressed H-modes and reducing the divertor power without triggering large ELMs at EAST. Access to high recycling and radiative divertor conditions while maintaining ELM suppression has been demonstrated in EAST by the use of gas fuelling and neon impurity seeding. Both approaches have been found to be effective in reducing power fluxes to the divertor strike points in near-separatrix lobes for both n = 2 and n = 4 RMPs. Furthermore, reduction of power fluxes in off-separatrix lobes is only effective for n = 4 RMP application, which is consistent with magnetic topology modelling (including plasma response) results showing a shallow penetration into the confined plasma region of field lines connected to these lobes compared to n = 2. The EAST results support the use of high n 3D fields for ELM suppression in ITER high Q DT scenarios since they provide optimum integration features regarding energy and particle confinement, pellet fuelling, radiative divertor operation while eliminating ELM transient power loads and being compatible with low torque input.

pellet fuelling↗

Final Report on CFD and Thermal-Mechanical Stress Analysis of PWR Surge Line under Transient Condition Thermal Stratification and an Evolutionary Cyclic Plasticity Based Transformative Fatigue Evaluation Approach without Using S~N Curve: Rev. 1

This report presents an evolutionary cyclic plasticity based transformative approach for fatigue evaluation of safety critical components. This approach is generic which can be used not only for the present generation light water reactor components (which is our focus) but also for advanced reactor components. The approach is based on the fundamental concept of time-evolution of progressive fatigue damage rather than the end-of-life data based conventional S~N curve approaches. Series of fatigue tests on 316 stainless steel uniaxial specimens were conducted under strain-controlled and stress-controlled cyclic loading in two different environment such as in-air at 300 °C and PWR coolant water condition at 300 °C. Material models are developed to capture the uniaxial test data and are subsequently programmed into commercially available ABAQUS code to transform the uniaxial material behavior to multiaxial loading domain. The developed evolutionary cyclic-plasticity approach is verified by both analytical and 3D-FE modeling of uniaxial fatigue test specimens. Results show that the developed material models can capture the time-dependence of material hardening and softening with great accuracy. In addition, results show that the material models not only can capture the material behavior under constant amplitude loading but also can capture the load-sequence effect under variable and random amplitude loading. The ANL developed approach is one of its kind, which shows first in the fatigue research community that fatigue evaluation of a component (in our case verified for laboratory scale fatigue test specimens with great accuracy) can be performed for its entire fatigue life, including the hardening and softening behavior, without using a conventional S~N curve based approach. Additionally results are presented related to fatigue evaluation of real reactor components such as of a pressurized water reactor (PWR) surge line (SL), under upset transient conditions. SLs of PWR experience complex thermal stratification due to the mixing of differential temperature flow from hot leg and pressurizer. A detailed parametric study of thermal stratification in SL is performed through both standalone computational fluid dynamics (CFD) analysis and fluid-structure-interaction based coupled CFD and heat transfer analysis. Results show that the mass flow rate in SL substantially affects the extent of its thermal stratification. The resulting thermal boundaries conditioned are used as inputs for thermal-mechanical stress analysis and component level fatigue evaluation. Fatigue evaluation of SL pipe under example loading conditions was performed using the above-mentioned evolutionary-plasticity based approach and ASME code (for in-air life) and NUREG-6909 (for PWR environment life) based approaches. Results show that the evolutionary plasticity based approach estimate substantially different life compared to the conventional ASME based approach. To show the entirety of the proposed evolutionary fatigue-modeling framework, this report includes the results presented in semi-annual March report (ANL/LWRS-17/01). Sections 2-5 of March report are directly included as Sections 2-5 in this report, without any significant changes. However, Sections 6-9 of this report present the work performed during March-September of 2017. Whereas, Sections 1 and 10 present the organization of this report and the summary and future work, respectively. This report (ANL/LWRS-17/03 Rev. 1) is a slightly revised version of the earlier published report (ANL/LWRS-17/03). In this revised version, some of the results and associated discussion have been corrected/updated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Selenium Nanocomposite Cathode with Long Cycle Life for Rechargeable Lithium‐Selenium Batteries

Abstract Selenium (Se) is a potential cathode material for high energy density rechargeable lithium batteries. In this study, a binder‐free Se‐carbon nanotube (CNT) composite electrode has been prepared by a facile chemical method. At initial state, Se is present in the form of branched nanowires with a diameter of <150 nm and a length of 1–2 μm, interwoven with CNTs. After discharge and re‐charge, the Se nanowires are converted to nanoparticles embedded in the CNT network. This synthesis method provides a path for fabricating the Se cathodes with controllable mass loading and thickness. By studying the composite electrodes with different Se loading and thickness, we found that the electrode thickness has a critical impact on the distribution of Se during repeated cycling. Promising cycling performance was achieved in thin electrodes with high Se loading. The composite electrode with 23 μm thickness and 60 % Se loading shows a high initial capacity of 537 mAh g −1 and stable cycling performance with a capacity of 401 mAh g −1 after 500 cycles at 1 C rate. This study reports a synthesis strategy to obtain Se/CNT composite cathode with long cycle life for rechargeable Li−Se batteries.

Cui, Yi↗

The onset and evolution of fatigue-induced abnormal grain growth in nanocrystalline Ni–Fe

Conventional structural metals suffer from fatigue-crack initiation through dislocation activity which forms persistent slip bands leading to notch-like extrusions and intrusions. Ultrafine-grained and nanocrystalline metals can potentially exhibit superior fatigue-crack initiation resistance by suppressing these cumulative dislocation activities. Prior studies on these metals have confirmed improved high-cycle fatigue performance. In the case of nano-grained metals, analyses of subsurface crack initiation sites have indicated that the crack nucleation is associated with abnormally large grains. But, these post-mortem analyses have led to only speculation about when abnormal grain growth occurs (e.g., during fatigue, after crack initiation, or during crack growth). In this study, a recently developed synchrotron X-ray diffraction technique was used to detect the onset and progression of abnormal grain growth during stress-controlled fatigue loading. Our study provides the first direct evidence that the grain coarsening is cyclically induced and occurs well before final fatigue failure—our results indicate that the first half of the fatigue life was spent prior to the detectable onset of abnormal grain growth, while the second half was spent coarsening the nanocrystalline structure and cyclically deforming the abnormally large grains until crack initiation. Post-mortem fractography, coupled with cycle-dependent diffraction data, provides the first details regarding the kinetics of this abnormal grain growth process during high-cycle fatigue testing. Finally, precession electron diffraction images collected in a transmission electron microscope after the in situ fatigue experiment also confirm the X-ray evidence that the abnormally large grains contain substantial misorientation gradients and sub-grain boundaries.

36 MATERIALS SCIENCE↗

Adiabatic Shear Localization and Microstructure in Ultrafine Grained Aluminum Alloy at Cryogenic Temperature

Adiabatic shear localization plays an important role in the deformation and failure of ultrafine grained 6061 aluminum alloy processed by friction stir processing. To understand the effects of temperature and strain on adiabatic shear localization in the ultrafine grained 6061 aluminum alloy, it has been investigated dynamic mechanical behavior of ultrafine grained 6061 aluminum alloy under the controlled shock loading experiments. Deformation characteristics and microstructures in the shear band were performed by optical microscopy and transmission electron microscopy. The shear band in the ultrafine grained aluminum alloy is a long and straight band distinguished from the matrix. The width of the shear band decreases with increasing nominal strain. The results show that the grains in the boundary of the shear band are highly elongated along the shear direction and form the elongated cell structures (0.2 μ in width), and the core of the shear band consists of a number of recrystallized equiaxed grains 0.2-0.3 μ in diameters and the second phases distribute in both the boundary and the inner of the equiaxed new grains. The calculated temperature in the shear band is about 692 K. Rotational dynamic recrystallization mechanism is responsible for the formation of the microstructure in the shear band.

36 MATERIALS SCIENCE↗

Numerical Study and Experimental Validation of Effect of Varying Fiber Crack Density on Stiffness Reduction in CFRP Composites

Representative volume element (RVE) has commonly been used to predict the stiffness of undamaged composite materials using finite element analysis (FEA). However, never has been an independently measured true microstructural damage quantity used in FEA to predict composite stiffness. Hence, in this work, measured fiber crack density in unidirectional fiber composite (generated using controlled fatigue loading) was used to predict reduction in stiffness using a RVE. It was found that the stiffness changes with change in depth of the volume element along the fiber direction and asymptotically reaches a constant value beyond a critical length called representative depth. It was argued that this representative depth should be more than the minimum of two characteristic length scales, twice of ineffective length and average length of broken fibers. Effective stiffness obtained from FEA of the optimum-sized RVE was in excellent agreement with the experimental results for given microstructural damage state.

36 MATERIALS SCIENCE↗

Increasing the Number of Installed Residential Heat Pump Water Heaters in the USA Through Improved Technology and Utility Programs

Heat pump water heaters (HPWHs) offer an efficient alternative to electric resistance water heaters, but they suffer from limited market penetration. This paper reviews the current state of HPWHs in the USA, focusing on technology developments and programs to increase adoption. What technological improvements are needed to make HPWHs a good fit in more homes? Additionally, what are the best ways of promoting HPWHs to consumers? Improved communication and controls will allow HPWHs to provide demand response and follow dynamic utility rates. To enable fuel-switching, HPWHs are being developed that only need a standard 120V outlet. Split HPWHs can alleviate the cooling and noise that limit the use of HPWHs in small homes, multifamily buildings, and cold climates. Additionally, new utility programs aim to train installers and provide incentives to distributors to increase the number of HPWHs installed. Some utilities offer novel incentive programs that have led to increased customer uptake. Those advances, coupled with improved controls for load shifting and new products such as split HPWHs and HPWHs that can run on 120V power, may finally move the market forward.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of dynamic fracture behavior of additively manufactured Al-10Si-Mg using high-speed synchrotron X-ray imaging

The dynamic tensile properties of additively manufactured (AM) and cast Al-10Si-Mg alloy were disccused using high-speed synchrotron X-ray imaging coupled with a modified Kolsky bar apparatus. A controlled tensile loading (strain rate &approx; 750 s -1 ) was applied using the Kolsky bar apparatus and the deformation and fracture behavior were recorded using the high-speed X-ray imaging setup. The CT and high-speed imaging results worked together to identify the location of the critical flaw and to capture the dynamics of crack propagation. In all experiments, the critical flaw was located on the surface of each specimen. The AM specimens displayed significantly higher crack propagation speed, yield strength, ultimate tensile strength, strain hardening coefficient, and yet lower ductility compared to the cast specimens under dynamic tension. Although the strength values were higher for the AM specimens, the critical mode I stress intensity factors were comparable for both specimens. The microstructures of the samples were characterized by synchrotron X-ray computed tomography (CT) and scanning electron microcopy. The correlation between the dynamic fracture behavior of the samples and the microstructure of the samples is analyzed and discussed.

36 MATERIALS SCIENCE↗